About Sump, Water-Removal, Condensate, and Submersible Pumps
More
How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
About Drum Pumps
More
Extended-Life Immersion Circulation Pumps for Water and Coolants
A sealless construction means these pumps have few moving parts that can fail and shorten service life. The intake can be completely submerged in liquid. Pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Discharge (Female) | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Flow Rate @ 10 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Electrical Connection Type | hp | Current, A | Intake Connection Type | Tube Connection Type | For Tube OD | Dia. | Ht. | Shaft Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
11 | 7 | 13 | 5 | 70 | 50° to 150° | Plug | 1/15 | 2.4 | Screened Inlet | Push to Connect | 5/8" | 5" | 13" | 8 1/8" | 0000000 | 0000000 |
11 | 7 | 13 | 5 | 70 | 50° to 150° | Plug | 1/15 | 2.4 | Screened Inlet | Push to Connect | 5/8" | 5" | 15" | 10 1/2" | 0000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
11 | 7 | 13 | 5 | 70 | 50° to 150° | Plug | 1/15 | 1.2 | Screened Inlet | Push to Connect | 5/8" | 5" | 10" | 5 1/8" | 0000000 | 000000 |
11 | 7 | 13 | 5 | 70 | 50° to 150° | Plug | 1/15 | 1.2 | Screened Inlet | Push to Connect | 5/8" | 5" | 13" | 8 1/8" | 0000000 | 000000 |
11 | 7 | 13 | 5 | 70 | 50° to 150° | Plug | 1/15 | 1.2 | Screened Inlet | Push to Connect | 5/8" | 5" | 15" | 10 1/2" | 0000000 | 000000 |
Replacement Impeller | 0000000 | Each | 0000000 |
Battery-Operated Drum Pumps with Nozzle for Oil
Quickly and cleanly transfer oil with no need for an electrical connection, air connection, or manual pumping. These drum pumps come with everything they need to operate.
Add extra stem assemblies to move a single pump head across multiple containers.
Use additional pump heads to transfer oil to multiple locations at once. Pump heads fit all stem assemblies.
To control the exact amount of oil you move, connect a meter.
Add batteries to minimize downtime—swap in a second battery while another charges.
Intake Tube | Discharge (Hose and Nozzle) | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | For Use With | Temp. Range, °F | Horsepower | For Drum Opening Size | Includes | OD | Lg. | Hose ID | Hose Lg., ft. | Nozzle Type | Batteries Included | Features | Each | |
Single Phase—With Thermal Overload Protection | ||||||||||||||||
1.5 | 5 | 2,200 | Automatic Transmission Fluid, Coolant, Gear Oil, Hydraulic Oil, Motor Oil | 32° to 100° | 1/15 hp | 2 NPT | Drum Connector | 1" | 12 3/4"-17 1/2" | 3/4" | 5 | Manual Shut-Off | Yes | Removable Pump Head | 00000000 | 0000000 |
1.5 | 16 - 55 | 2,200 | Automatic Transmission Fluid, Coolant, Gear Oil, Hydraulic Oil, Motor Oil | 32° to 100° | 1/15 hp | 2 NPT | Drum Connector | 1" | 21 1/2"-39 3/4" | 3/4" | 5 | Manual Shut-Off | Yes | Removable Pump Head | 00000000 | 000000 |
Intake Tube | ||||||||
---|---|---|---|---|---|---|---|---|
For Container Size, gal. | For Drum Opening Size | Includes | OD | Lg. | Hose Lg., ft. | Nozzle Type | Each | |
For Automatic Transmission Fluid, Coolant, Gear Oil, Hydraulic Oil, Motor Oil | ||||||||
5 | 2 NPT | Drum Connector, Hose, Intake Tube, Nozzle | 1" | 12 3/4"-17 1/2" | 5 | Manual Shut-Off | 00000000 | 0000000 |
16 - 55 | 2 NPT | Drum Connector, Hose, Intake Tube, Nozzle | 1" | 21 1/2"-39 3/4" | 5 | Manual Shut-Off | 00000000 | 000000 |
Horsepower | No. of Batteries Required | Each | |
Single Phase—With Thermal Overload Protection | |||
---|---|---|---|
1/15 hp | 1 | 00000000 | 0000000 |
Scale | Accuracy | Temp. Range, °F | Pipe Size | Thread Type | Features | Each | |
Gallons, Liters, Quarts | ±2% | 0° to 155° | 1/2 | BSPP | Nonresettable Flow Counter for Total Volume; Resettable Batch Function | 00000000 | 0000000 |
Voltage | Battery Capacity, amp-hrs. | Each | |
18V DC | 2 | 00000000 | 000000 |
Battery Charging Time, hrs. | Battery Charger Voltage | Each | |
1 | 120V AC | 00000000 | 000000 |
Submersible Pumps for Water
Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
B | Plug | 5.6 | 4.3 | 0.8 | 11.1 | 35° to 85° | 1/15 hp | 0.8 | Screened | 1/4 | NPT | Male | 6 | 4" | 3 7/8" | 5 3/8" | 0000000 | 000000 |
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
E | Plug | 20 | 12 | 4 | 15 | 35° to 85° | 1/15 hp | 1 | Screened | 3/4 | NPT | Male | 15 | 5 1/4" | 3 3/4" | 6 3/8" | 00000000 | 0000000 |
Impact-Resistant Submersible/Open-Air Pumps for Water
Protected from impact by a durable epoxy-coated aluminum housing, these pumps can be submerged or connected remotely to a pipe in your line. Use to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Features | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug | |||||||||||||||||||
B | 8.3 | 5.6 | 3.5 | 17.3 | 35° to 120° | 1/15 hp | 3.2 | 1/2 | NPT | Female | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | Removable Intake Screen | 000000 | 0000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
B | 10 | 8.6 | 6.9 | 21 | 35° to 120° | 1/15 hp | 1.4 | 1/2 | NPT | Female | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | Removable Intake Screen | 0000000 | 000000 |
Flood Coolant Dispensers with Reservoir
These dispensers have a reservoir for recirculating coolant. They provide a constant flow of coolant, so they dissipate heat more efficiently than mist and droplet dispensers, making them suitable for cooling long machine cycles. Coolant strainers prevent debris from getting into the recirculated coolant.
Maximum flow rate and shut-off height are for water-soluble oil. Shut-off height is the maximum height to which the water-soluble oil can be pumped.
Nozzle | Reservoir | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cap., gal. | Max. Flow Rate | Max. Pressure, psi | Coolant Outlet Hose Lg. | Lg. | Type | Nozzle Material | O'all Ht. | Wd. | Dp. | Reservoir Material | Shut-Off Ht., ft. | For Max. SSU Viscosity Grade | Voltage | Features | Each | ||
For Use With Coolant, Water | |||||||||||||||||
B | 5 | 500 gph @ 1 ft. of head | 7.5 | 6 ft. | 12" | Flexible | Acetal Plastic | 8 1/2" | 16 7/8" | 11 1/4" | Polyethylene Plastic | 17.3 | 300 | 120V AC | Adjustable Flow, Coolant Strainer, Baffle, On/Off Valve | 00000000 | 0000000 |
D | 10 | 500 gph @ 1 ft. of head | 7.5 | 4 ft. | 12" | Flexible | Acetal Plastic | 12" | 25" | 10" | Steel | 17.3 | 300 | 120V AC | Adjustable Flow, Coolant Strainer, Baffle, On/Off Valve | 00000000 | 000000 |