How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
About Sump, Water-Removal, Condensate, and Submersible Pumps
More
High-Flow Harsh-Environment Low-Maintenance
Plastic Circulation Pumps for Water and Coolants
A powerful motor provides twice the flow rate of other extended-life circulation pumps. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Magnets turn the impeller to eliminate seal wear and leakage for a long service life. These pumps are often used with electroplating and photographic solutions. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Impellers | ||||||||||||||||
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | @ 60 ft. of Head | Max. ft. of Head | Max. Pressure, psi | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
120/240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
53 | __ | 41 | 33 | 28 | 1 | 60 | 50 | 3/4 | 10/5 | 1 1/2 | Female | 1 | Male | 17 7/8" | 9" | 9" | 0000000 | 000000000 | 0000000 | 0000000 |
53 | 42 | 37 | 28 | 18 | __ | 58.9 | 25 | 3/4 | 11.8/5.9 | 1 1/2 | Female | 1 | Male | 17 1/4" | 8 5/8" | 8 1/2" | 00000000 | 00000000 | 000000 | 00 |
240/460V AC, Three Phase—With Thermal Overload Protection | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
53 | 42 | 37 | 28 | 18 | __ | 58.9 | 25 | 3/4 | 2.9/1.5 | 1 1/2 | Female | 1 | Male | 17 1/4" | 8 5/8" | 8 5/8" | 00000000 | 00000000 | 000000 | 00 |
Harsh-Environment Circulation Pumps for Water and Oil
The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Use these pumps to move water and lubricating oil in boiler feed systems, cooling towers, and heat exchangers. The housing rotates for vertical or horizontal discharge. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created, which allows the pump to draw liquid upward.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | |
120/208-240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
69 | 61 | 52 | 42 | 24 | 4 | 52 | 75 | 20 | 3/4 | 10/5.2- 5 | 1 1/2 | Female | 1 1/2 | Female | 15 7/8" | 8 7/8" | 9 1/2" | 0000000 | 000000000 |
208-240/460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
69 | 61 | 52 | 42 | 24 | 4 | 52 | 75 | 20 | 3/4 | 2.8- 2.7/1.35 | 1 1/2 | Female | 1 1/2 | Female | 15 3/8" | 8 7/8" | 9 1/2" | 0000000 | 00000000 |
Replacement Seal Assembly | 00000000 | Each | 000000 |
High-Efficiency Circulation Pumps for Water, Coolants, and Oil
Use less electricity to achieve the same flow rates as other circulation pumps. These pumps have a totally enclosed motor for use in dusty, dirty, and damp environments. Adjust the housing studs to make the discharge direction more vertical or horizontal. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Impellers | |||||||||||||
Max. Flow Rate, gpm | @ 30 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
208-240/460V AC, Three Phase | |||||||||||||||||
Hardwire | |||||||||||||||||
45 | 34 | 40 | 100 | 17 | 3/4 | 3.3- 3/1.5 | 1 | Female | 3/4 | Female | 14" | 8 1/2" | 7" | 0000000 | 000000000 | 0000000 | 0000000 |
High-Head Circulation Pumps for Water
Also known as booster pumps, these have a multistage impeller that propels water about two times higher and farther than standard circulation pumps. Use them in applications such as water delivery, irrigation, and pressure washing. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 60 ft. of Head | @ 70 ft. of Head | @ 80 ft. of Head | @ 90 ft. of Head | @ 100 ft. of Head | @ 110 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | |
120/240V AC, Single Phase | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
22 | 21 | 19 | 17 | 14 | 12 | 8 | 121 | 232 | 50 | 3/4 | 7.6/3.9 | 1 | Female | 1 | Female | 12" | 6 1/4" | 8 1/4" | 0000000 | 000000000 |
High-Head Circulation Pumps for Water, Coolants, and Oil
Propel liquid higher and farther than standard circulation pumps. They're commonly used with chillers, heat exchangers, and boiler feed systems. The motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Impellers | ||||||||||||||||||
Max. Flow Rate, gpm | @ 80 ft. of Head | @ 90 ft. of Head | @ 100 ft. of Head | @ 150 ft. of Head | @ 200 ft. of Head | @ 250 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
120/208-240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||||
Hardwire | ||||||||||||||||||||||
6 | 6 | 6 | 6 | 5 | 5 | 4 | 280 | 120 | 54 | 3/4 | 10.3/5.2 | 1 | Female | 1 | Female | 14 1/8" | 6 1/2" | 6 7/8" | 00000000 | 000000000 | 000000000 | 0000000 |
Maintenance Kits | 000000000 | Each | 0000000 |
High-Flow Inline Circulation Pumps for Water
A high-horsepower motor handles four times the flow and twice the pressure of other inline circulation pumps. Install these pumps directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Mount horizontally or vertically. The motor cannot face downward; it’s cooled by the water being pumped. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake | Discharge | Overall | Required Pipe Connectors | ||||||||||||||
Max. Flow Rate, gpm | @ 30 ft. of Head | @ 40 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Thread Type | Pipe Size | Thread Type | Lg. | Wd. | Ht. | Each | Pair | ||
120/208-240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Hardwire | ||||||||||||||||||
100 | 71 | 47 | 45 | 145 | 1 | 3/4 | 9.6/5.3-4.8 | 1 1/2 | NPT | 1 1/2 | NPT | 9 1/4" | 11 1/2" | 17 3/4" | 0000000 | 000000000 | 00000000 | 000000 |
208-240/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||||
Hardwire | ||||||||||||||||||
100 | 71 | 47 | 45 | 145 | 1 | 3/4 | 2.4-2.3/1.2 | 1 1/2 | NPT | 1 1/2 | NPT | 8 5/8" | 11 1/2" | 15 7/8" | 0000000 | 00000000 | 00000000 | 00000 |
Self-Priming Circulation Pumps for Water and Coolants
Drain underground tanks and process wastewater with pumps that can be installed up to 20 ft. above your liquid source. They have an open dripproof (ODP) motor for use in clean, dry, and well-ventilated environments. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Impellers | ||||||||||||||
Max. Flow Rate, gpm | @ 40 ft. of Head | @ 50 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
120/240V AC, Single Phase— With Thermal Overload Protection | ||||||||||||||||||
Hardwire | ||||||||||||||||||
82 | 49 | 34 | 65 | 75 | 1 | 3/4 | 13/7 | 1 1/4 | Female | 1 1/4 | Female | 17 1/2" | 6 7/8" | 7 1/4" | 00000000 | 0000000 | 000000000 | 000000 |
120 | 54 | 44 | 80 | 75 | 1 | 3/4 | 13/7 | 1 1/2 | Female | 1 1/2 | Female | 17 1/4" | 7 3/8" | 10" | 00000000 | 000000 | 000000 | 00 |
Harsh-Environment Self-Priming Circulation Pumps for Water and Coolants
The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Install these pumps up to 20 ft. above your liquid source to drain underground tanks and process wastewater. They are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Pumps | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
120/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
82 | __ | 49 | 36 | 58 | 75 | 1 | 3/4 | 9/5 | 1 1/4 | Female | 1 1/4 | Female | 17 7/8" | 8 7/8" | 7 1/4" | 00000000 | 0000000 | 000000000 | 000000 |
120 | 52 | 46 | __ | 70 | 75 | 1 | 3/4 | 9/5 | 1 1/2 | Female | 1 1/2 | Female | 17 1/2" | 9 1/8" | 10" | 00000000 | 000000 | 000000000 | 00000 |
240/460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
82 | __ | 49 | 36 | 58 | 75 | 1 | 3/4 | 3/2 | 1 1/4 | Female | 1 1/4 | Female | 17 3/8" | 8 7/8" | 8 5/8" | 00000000 | 000000 | 000000000 | 00000 |
120 | 52 | 46 | __ | 70 | 75 | 1 | 3/4 | 3/2 | 1 1/2 | Female | 1 1/2 | Female | 17" | 9 1/8" | 10" | 00000000 | 000000 | 000000000 | 00000 |
Immersion Circulation Pumps for Coolants
Commonly used in machine tool coolant tanks, these pumps have an intake that can be completely submerged in liquid. A universal mounting plate fits machine tools from manufacturers such as Fuji, Mitsubishi, Toshiba, Hitachi, and Yasukawa. Motor is totally enclosed with sealed bearings for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. They can run dry.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge (NPT) | Overall | Replacement Impellers | ||||||||||||||||||
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Intake Connection Type | Pipe Size | Gender | Lg. | Wd. | Ht. | Shaft Ht. | Each | Each | ||
240/460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
45 | 52 | 45 | 35 | 25 | 10 | 55 | 23 | 90 | 3/4 | 2.6/1.6 | Open Inlet | 1 | Female | 8 3/8" | 6" | 20 29/32" | 11 15/32" | 00000000 | 000000000 | 0000000 | 0000000 |
Heavy Duty Immersion Circulation Pumps for Water and Coolants
The durable motor and impeller can handle dirty coolant and machine lubricants with solids up to 1/4" diameter. These pumps have an intake that can be completely submerged in liquid. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 20 ft. of Head | Max. ft. of Head | Max. Pressure | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Intake Connection Type | Pipe Size | Gender | Thread Type | Lg. | Wd. | Ht. | Shaft Ht. | Each | ||
208-240/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||||
Hardwire | ||||||||||||||||||
3 | 67 | 40 | 32 | Not Rated | 108 | 40° to 200° | 3/4 | 3/2 | Open Inlet | 1 1/2 | Female | NPT | 10 3/4" | 9 1/4" | 19 3/4" | 9 7/8" | 0000000 | 0000000 |
4 | 67 | 40 | 32 | Not Rated | 108 | 40° to 200° | 3/4 | 3/2 | Open Inlet | 1 1/2 | Female | NPT | 10 3/4" | 9 1/4" | 25 3/4" | 15 7/8" | 0000000 | 000000 |
Remote-Mount Circulation Pumps for Water and Coolants
Use when space is limited—these pumps connect to a pipe coming from your tank so you can place the pump in another location. Mount above or below the liquid level. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Replacement Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
240/460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
43 | 35 | 25 | 10 | 55 | 23 | 90 | 3/4 | 2.6/1.6 | 1 | Female | 1 | Female | 8 5/8" | 8 1/16" | 12 1/4" | 00000000 | 000000000 | 0000000 | 0000000 |
Maintenance Kit for Pumps with 32 gpm, 43 gpm, or 48 gpm Max. Flow Rate | 00000000 | Each | 0000000 |
Stainless Steel Circulation Pumps for Chemicals
A 316 stainless steel housing sealed with fluoroelastomer resists mild chemicals and acids, such as coolant, oil, and phosphoric acid. These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Replacement Impellers | ||||||||||||||||
Max. Flow Rate, gpm | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Solids Dia. | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
120/240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
32 | 32 | 32 | 20 | 62 | 100 | 3/32" | 50 | 3/4 | 10.6/5.3 | 1 1/4 | Female | 3/4 | Female | 16" | 9" | 7 3/4" | 0000000 | 000000000 | 0000000 | 0000000 |
38 | 33 | 27 | 18 | 59 | 100 | 1/8" | 50 | 3/4 | 10.6/5.3 | 3/4 | Female | 1/2 | Female | 15" | 9" | 7 1/2" | 0000000 | 000000 | 0000000 | 000000 |
Self-Priming Stainless Steel Circulation Pumps for Chemicals
Self-priming up to 6 ft., these pumps have a stainless steel housing sealed with PTFE to resist chemicals such as ammonia and detergents as well as harsh solvents including methyl ethyl ketone (MEK). The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | ||
120/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
1 | 68 | 54 | 41 | 50 | 75 | 20 | 3/4 | 9/5 | 1 1/2 | Female | 1 1/2 | Female | 15 3/4" | 8 3/4" | 9 1/2" | 0000000 | 000000000 |
240/460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
3 | 68 | 54 | 41 | 50 | 75 | 20 | 3/4 | 3/2 | 1 1/2 | Female | 1 1/2 | Female | 15 1/4" | 8 3/4" | 9 1/2" | 0000000 | 00000000 |
Sump Pumps with Basin for Sewage Water
Convenient for applications where a sump pit is impractical, these pumps include a basin with a vent on top. They handle raw sewage water with solids up to 2" in diameter. The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump.
Max. Flow Rate, gpm | Level | Discharge | O'all | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Feet of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Cap., gal. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||||
144 | 126 | 105 | 74 | 28 | 2" | 11 1/2" | 4 1/2" | 41 | 35° to 100° | 3/4 hp | 12 | Open | 2 | NPT | Female | 24" | 29" | 25" | 0000000 | 000000000 |
Steam Condensate Pumps
Use these pumps in low-pressure steam systems to capture hot condensate and return it to your boiler or feed unit. Wire your own pump activation switch.
Max. Flow Rate, gpm | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 35 Ft. of Head | @ 50 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Temp. Range, °F | Horsepower | Current, A | Intake Pipe Connection Type | Pipe Size | Discharge Pipe Size | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||
Hardwire | ||||||||||||||
50 | 23 | 58 | 20 | 35° to 212° | 3/4 hp | 8.2 | Flanged | 2 3/4 | 1 1/2 NPT Female | 16 3/4" | 7 3/8" | 10 3/4" | 00000000 | 000000000 |