Filter by
Product Family
Thermometer Type
Maximum Temperature
Measurement Unit
Minimum Temperature
Emissivity Adjustability
Thermometer Features
DFARS Specialty Metals
Adjustability
Housing Material
Electrical Connection
Noncontact Infrared Temperature Sensors
For Nonmetal Surfaces with 3.25 ft. Long Cable
Sensor | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Measurement Range, ° F | Min. Object Size Detected | Max. Sensing Distance | Wavelength, μm | Optical Resolution | Accuracy @ Temperature | Response Time, sec. | Lg. | Dia. | Input Voltage, V DC | For Panel Cutout Dia. | Thread Size | Includes | Enclosure Rating | Each | |||
0 to 5V DC, 0 to 10V DC, Type K Thermocouple Output Signal | |||||||||||||||||
Adjustable Emissivity (0.1 to 1.1) | |||||||||||||||||
| -40 to 1,886 | 0.03" | 1.57" | 8 to 14 | 15:1 | ±3° F Below 200° F ±1.5% Above 200° F | 0.025 | 3 1/2" | 1/2" | 5 to 30 | 1/2" | M12 × 1 mm | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters), Close Focus Lens | IP65 | 3889K12 | 0000000 | ||
| -40 to 1,886 | 0.24" | 2.6 ft. | 8 to 14 | 15:1 | ±3° F Below 200° F ±1.5% Above 200° F | 0.025 | 3 1/2" | 1/2" | 5 to 30 | 1/2" | M12 × 1 mm | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters) | IP65 | 3889K41 | 000000 | ||
4 to 20 mA Output Signal | |||||||||||||||||
Adjustable Emissivity (0.1 to 1.1) | |||||||||||||||||
| -58 to 1,886 | 0.03" | 1.57" | 8 to 14 | 15:1 | ±2° F Below 200° F ±1.5% Above 200° F | 0.014 | 1 1/8" | 1/2" | 5 to 30 | 1/2" | M12 × 1 mm | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters), Close Focus Lens | IP65, NEMA 4 | 3889K13 | 000000 | ||
| -58 to 1,886 | 0.26" | 3.2 ft. | 8 to 14 | 15:1 | ±2° F Below 200° F ±1.5% Above 200° F | 0.014 | 1 1/8" | 1/2" | 5 to 30 | 1/2" | M12 × 1 mm | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters) | IP65, NEMA 4 | 3889K42 | 000000 | ||
Type J Thermocouple Output Signal | |||||||||||||||||
Fixed Emissivity (0.95) | |||||||||||||||||
| 32 to 662 | 0.17" | 4 ft. | 7 to 18 | 4:1 | ±6° F Below 241° F ±5% Between 241° F to 440° F Not Rated Above 440° F | 0.35 | 3 1/2" | 3/4" | 12 to 24 | 3/4" | 3/4"-16 | — | IP65, NEMA 4 | 3889K111 | 000000 | ||
| 86 to 932 | 0.17" | 4 ft. | 7 to 18 | 4:1 | ±10° F Below 212° F ±6° F Between 212° F to 300° F ±2% Above 300° F | 0.35 | 3 1/2" | 3/4" | 12 to 24 | 3/4" | 3/4"-16 | — | IP65, NEMA 4 | 3889K211 | 000000 | ||
For Metal Surfaces with 3.25 ft. Long Cable
Sensor | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Measurement Range, ° F | Min. Object Size Detected | Max. Sensing Distance | Wavelength, μm | Optical Resolution | Accuracy @ Temperature | Response Time, sec. | Lg. | Dia. | Input Voltage, V DC | For Panel Cutout Dia. | Thread Size | Includes | Enclosure Rating | Each | |||
4 to 20 mA Output Signal | |||||||||||||||||
Adjustable Emissivity (0.1 to 1.1) | |||||||||||||||||
| 122 to 662 | 0.2" | 15.7" | 2.3 | 22:1 | ±(0.3% of Temperature Measured + 3.6° F) | 0.02 | 1 1/4" | 1/2" | 5 to 30 | 1/2" | M12 × 1 mm | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters), Close Focus Lens | IP65, NEMA 4 | 3889K14 | 0000000 | ||
| 122 to 662 | 0.26" | 3.6 ft. | 2.3 | 22:1 | ±(0.3% of Temperature Measured + 3.6° F) | 0.02 | 1 1/4" | 1/2" | 5 to 30 | 1/2" | M12 × 1 mm | 3-ft. Lg. Micro USB Cord with 5-Pin Terminal Block (with USB-A and USB-C Adapters) | IP65, NEMA 4 | 3889K43 | 000000 | ||
Infrared Thermometers
![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
Style A | Style B | Style C | Style D | Style E | Style F |
Batteries | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Temp. Range | Resolution/Temp. Resolution | Accuracy | Max. Distance | Emissivity | Response Time, sec. | Ht. | Wd. | Dp. | Housing Material | Includes | Thermometer Features | Certification | Included | Size | No. of | Each | |||
For Dark, Light, and Shiny Surfaces | ||||||||||||||||||||
Adjustable Emissivity | ||||||||||||||||||||
| A | -58° F to 1,200° F/-50° C to 650° C | 0.1/0.1° C | ±1% | 12" | 0.1 to 1 | 1 | 6 3/8" | 1 5/8" | 3 1/4" | Plastic | Carrying Case | Automatic Shutoff, Laser Sight | CE Marked | Yes | 9V | 1 | 9254T61 | 0000000 | ||
| B | -58° F to 1,832° F/-50° C to 1,000° C | 0.1/0.1° C | ±1% | 30" | 0.1 to 1 | 1 | 5 3/4" | 1 5/8" | 4" | Plastic | Carrying Case | Automatic Shutoff, Laser Sight | CE Marked | Yes | 9V | 1 | 9254T111 | 000000 | ||
| C | -40° F to 1,022° F/-40° C to 550° C | 0.1/0.1° C | ±1% | 12" | 0.3 to 0.95 | 1 | 7" | 2" | 6 1/2" | Plastic | Carrying Case | Automatic Shutoff, Laser Sight | CE Marked | Yes | AA | 2 | 11175K91 | 000000 | ||
| D | -40° F to 1,202° F/-40° C to 650° C | 0.1/0.1° C | ±1% | 30" | 0.1 to 1 | 1 | 7" | 2" | 6 1/2" | Plastic | Carrying Case | Automatic Shutoff, Laser Sight | CE Marked | Yes | AA | 2 | 11175K93 | 000000 | ||
| D | -40° F to 1,472° F/-40° C to 800° C | 0.1/0.1° C | ±1% | 50" | 0.1 to 1 | 1 | 7" | 2" | 6 1/2" | Plastic | Carrying Case | Automatic Shutoff, Laser Sight | CE Marked | Yes | AA | 2 | 11175K94 | 000000 | ||
| E | -22° F to 932° F/-30° C to 500° C | 0.1/0.1° C | ±1.5% | 12" | 0.1 to 1 | 1 | 6 7/8" | 3" | 3 3/8" | Plastic | — | Automatic Shutoff, Laser Sight | CE Marked | Yes | AA | 1 | 3734K62 | 000000 | ||
| F | -4° F to 1,202° F/-20° C to 650° C | 0.1/0.1° C | ±1% | 12" | 0.1 to 1 | 1 | 7 7/16" | 2 3/16" | 4 5/8" | Plastic | Carrying Case | Automatic Shutoff, Laser Sight, Waterproof | CE Marked | Yes | 9V | 1 | 9254T112 | 000000 | ||
Infrared Thermometers with Calibration Certificate
![]() | ![]() | ![]() | ![]() |
Style A | Style B | Style C | Style D |
![]() | ![]() | ![]() | ![]() |
Style E | Style F | Style G | Style H |
Batteries | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Temp. Range | Resolution/Temp. Resolution | Accuracy | Max. Distance | Emissivity | Response Time, sec. | Ht. | Wd. | Dp. | Housing Material | Includes | Thermometer Features | Certification | Included | Size | No. of | Each | |||
For Dark Surfaces | ||||||||||||||||||||
Fixed Emissivity | ||||||||||||||||||||
| A | -76° F to 932° F/-60° C to 500° C | 0.1/0.1° C | ±2% | Not Rated | 0.95 | 1 | 7" | 1 1/2" | 3" | Plastic | — | Automatic Shutoff, Laser Sight | CE Marked | Yes | AAA | 2 | 9248T57 | 0000000 | ||
| B | -58° F to 1,832° F/-50° C to 1,000° C | 0.1/0.1° C | ±1.5% | Not Rated | 0.95 | 1 | 9" | 2 1/4" | 4" | Plastic | Carrying Case | Automatic Shutoff, Laser Sight | CE Marked | Yes | 9V | 1 | 40045K51 | 000000 | ||
For Dark, Light, and Shiny Surfaces | ||||||||||||||||||||
Fixed Emissivity | ||||||||||||||||||||
| B | -4° F to 630° F/-20° C to 330° C | 0.1/0.1° C | ±2% | Not Rated | 0.95 | 0.5 | 6 1/4" | 1 9/16" | 3 3/16" | Plastic | Carrying Case | Automatic Shutoff, Laser Sight | CE Marked | Yes | 9V | 1 | 9254T913 | 000000 | ||
Adjustable Emissivity | ||||||||||||||||||||
| C | -58° F to 1,200° F/-50° C to 650° C | 0.1/0.1° C | ±1% | 12" | 0.1 to 1 | 1 | 6 3/8" | 1 5/8" | 3 1/4" | Plastic | Carrying Case | Automatic Shutoff, Laser Sight | CE Marked | Yes | 9V | 1 | 9254T72 | 000000 | ||
| D | -40° F to 1,202° F/-40° C to 650° C | 0.1/0.1° C | ±1% | 30" | 0.1 to 1 | 1 | 7" | 2" | 6 1/2" | Plastic | Carrying Case | Automatic Shutoff, Laser Sight | CE Marked | Yes | AA | 2 | 11175K53 | 000000 | ||
| D | -40° F to 1,472° F/-40° C to 800° C | 0.1/0.1° C | ±1% | 50" | 0.1 to 1 | 1 | 7" | 2" | 6 1/2" | Plastic | Carrying Case | Automatic Shutoff, Laser Sight | CE Marked | Yes | AA | 2 | 11175K54 | 000000 | ||
| E | -40° F to 1,022° F/-40° C to 550° C | 0.1/0.1° C | ±1% | 12" | 0.3 to 0.95 | 1 | 7" | 2" | 6 1/2" | Plastic | Carrying Case | Automatic Shutoff, Laser Sight | CE Marked | Yes | AA | 2 | 11175K51 | 000000 | ||
| F | -4° F to 1,202° F/-20° C to 650° C | 0.1/0.1° C | ±1% | Not Rated | 0.1 to 1 | 0.5 | 7 3/8" | 2 3/16" | 4 9/16" | Plastic | Carrying Case | Laser Sight | CE Marked | Yes | 9V | 1 | 9254T912 | 000000 | ||
| G | -58° F to 1,832° F/-50° C to 1,000° C | 0.1/0.1° C | ±1% | Not Rated | 0.1 to 1 | 0.5 | 5 11/16" | 1 11/16" | 4 1/16" | Plastic | Carrying Case | Laser Sight | CE Marked | Yes | 9V | 1 | 9254T911 | 000000 | ||
| H | -58° F to 3,992° F/-50° C to 2,200° C | 0.1/0.1° C | ±1% | Not Rated | 0.1 to 1 | 0.1 | 8" | 2" | 6 1/8" | Plastic | Carrying Case | Bargraph, Laser Sight | CE Marked | Yes | 9V | 1 | 9254T915 | 000000 | ||
Digital Pocket Thermometers
Stem | Material | Batteries | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Temp. Range | Resolution/Temp. Resolution | Accuracy | Lg. | Dia. | Digit Ht. | Overall Lg. | With On/Off Switch | Housing | Stem | Includes | Included | No. of | Each | |||
| B | -40° F to 482° F/-40° C to 250° C | 0.1/0.1° C | ±2.7° F/±1.5° C | 2 7/8" | 1/8" | 1/4" | 6 1/2" | Yes | Plastic | Stainless Steel | Plastic Probe Sheath | Yes | 2 | 3312K4 | 000000 | ||
Infrared Thermometer Transmitters
![]() | ![]() | ![]() |
LED Display |
Transmitters | Brackets | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wavelength Range, μm | Temperature Range | Resolution | Accuracy | Digital Display Type | Emissivity | Response Time, sec. | Lg. | Dia. | Housing Material | Output Type | Each | Each | ||||
Bracket Mount with Scratch-Resistant Lens | ||||||||||||||||
| 0.78 to 1.06 | 932° F to 4,532° F/500° C to 2,500° C | 1° F/1° C | ±0.3% | LED | 0.1 to 1.1 | 0.002 | 8 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 4680N115 | 000000000 | 55205K13 | 000000 | ||
| 1 to 1.7 | 482° F to 2,912° F/250° C to 1,600° C | 1° F/1° C | ±0.5% | LED | 0.1 to 1.1 | 0.002 | 8 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 4680N113 | 00000000 | 55205K13 | 00000 | ||
| 8 to 14 | 32° F to 1,831° F/0° C to 1,000° C | 1° F/0.5° C | ±1% | LED | 0.1 to 1.1 | 0.1 | 7 1/2" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 4680N111 | 00000000 | 55205K13 | 00000 | ||
Bracket Mount with Scratch-Resistant Lens and Laser Sight | ||||||||||||||||
| 1 to 1.7 | 482° F to 2,912° F/250° C to 1,600° C | 1° F/1° C | ±0.5% | LED | 0.1 to 1.1 | 0.002 | 9 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 4680N114 | 00000000 | 55205K13 | 00000 | ||
| 8 to 14 | 32° F to 1,831° F/0° C to 1,000° C | 1° F/0.5° C | ±1% | LED | 0.1 to 1.1 | 0.1 | 8 1/8" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 4680N112 | 00000000 | 55205K13 | 00000 | ||
Pocket Infrared Thermometers
![]() | ![]() | ![]() | ![]() | ![]() | |
Style F (Shown in Use with Smartphone) | Style A | Style B | Style C | Style D | Style E |
Batteries | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Temp. Range | Resolution/Temp. Resolution | Accuracy | Max. Distance | Emissivity | Response Time, sec. | Ht. | Wd. | Dp. | Housing Material | Includes | Thermometer Features | Enclosure Rating | Certification | Included | Size | No. of | Each | |||
For Dark Surfaces | |||||||||||||||||||||
Fixed Emissivity | |||||||||||||||||||||
| A | -27° F to 482° F/-33° C to 250° C | 0.1/0.1° C | ±2% | Not Rated | 0.95 | 1 | 6" | 1/2" | — | Brass | Carrying Case | Automatic Shutoff | — | — | Yes | AAA | — | 4231K24 | 000000 | ||
| B | -27° F to 932° F/-33° C to 500° C | 0.1/0.1° C | ±2% | 6" | 0.95 | 1 | 6" | 1" | 1" | Plastic | — | Automatic Shutoff, Backlit Display, Laser Sight | — | CE Marked | Yes | AA | 1 | 4231K25 | 000000 | ||
| C | -13° F to 482° F/-25° C to 250° C | 0.1/0.1° C | ±2% | Not Rated | 95 | 1 | 3 1/8" | 1 1/4" | 3/4" | Plastic | Carrying Case | Min./Max. Memory | IP65 | CE Marked | Yes | CR2032 | 1 | 9212T22 | 000000 | ||
For Dark, Light, and Shiny Surfaces | |||||||||||||||||||||
Adjustable Emissivity | |||||||||||||||||||||
| D | -22° F to 572° F/-30° C to 300° C | 0.1/0.1° C | ±2% | 6" | 0.2 to 0.99 | 0.5 | 4 1/2" | 1.7" | 1" | Plastic | Carrying Case | Automatic Shutoff, Laser Sight | IP40 | CE Marked | Yes | AAA | 2 | 9212T21 | 000000 | ||
| E | 32° F to 932° F/0° C to 500° C | 1° F/1° C | ±3.6° F/±2° C | 15 ft. | 0.7 to 0.95 | 1 | 6 5/16" | 1 11/16" | 1 11/16" | Plastic | — | Automatic Shutoff, Laser Sight | IP67 | CE Marked | Yes | 9V | 1 | 6614T31 | 000000 | ||
For Dark, Dull, Light, and Shiny Surfaces | |||||||||||||||||||||
Adjustable Emissivity | |||||||||||||||||||||
| F | -22° F to 480° F/-30° C to 250° C | 0.1/0.1° C | ±2.7% | — | 0.1 to 1 | 1 | 5 1/2" | 1 3/8" | 1" | Plastic | — | Data Logging Capabilities, Laser Sight, Bluetooth, Min./Max. Memory | — | CE Marked | Yes | AAA | 3 | 4231K27 | 000000 | ||
Infrared Thermometer Transmitter Air Purges
![]() |
Material | Each | ||
|---|---|---|---|
| 303 Stainless Steel | 4680N116 | 0000000 |
Thermal Imaging Cameras
Adjustable Emissivity—For Dark, Dull, Light, Shiny Surfaces
Style | Temp. Range | Thermal Sensitivity (NETD) | Image Resolution | Accuracy | Emissivity | Ht. | Wd. | Dp. | Diag. Screen Size | Housing Material | Digital Display Type | Certification | Certificate Type | Batteries Included | Each | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A | -4° F to 752° F/-20° C to 400° C | 60 mK | 160 × 120 | ±2% | 0.1 to 1 | 9 9/16" | 3 11/16" | 5 1/2" | 3 1/2" | Plastic | LCD | CE Marked | — | Yes | 4006K7 | 000000000 | |
| A | -4° F to 1,200° F/-20° C to 650° C | <40 mK | 320 × 240 | ±2% | 0.01 to 1 | 11" | 4 5/8" | 4 3/8" | 4" | Plastic | LCD | CE Marked | — | Yes | 4006K91 | 00000000 | |
| A | -4° F to 1,200° F/-20° C to 650° C | <40 mK | 320 × 240 | ±2% | 0.01 to 1 | 11" | 4 5/8" | 4 3/8" | 4" | Plastic | LCD | CE Marked | Calibration Certificate Traceable to NIST | Yes | 4006K111 | 00000000 |
Fixed Emissivity—For Dark, Dull, Light, Shiny Surfaces
Emissivity | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Temp. Range | Thermal Sensitivity (NETD) | Image Resolution | Accuracy | For Dark Surfaces | For Dull Surfaces | For Light Surfaces | For Shiny Surfaces | Ht. | Wd. | Dp. | Housing Material | Certification | Batteries Included | Each | ||
| B | -4° F to 248° F/-20° C to 120° C | 70 mK | 80 × 60 | ±5% | 0.95 | 0.8 | 0.6 | 0.3 | 5 7/8" | 1 1/2" | 1 3/8" | Rubber | CE Marked | Yes | 4006K47 | 0000000 | |
| B | -4° F to 752° F/-20° C to 400° C | 70 mK | 160 × 120 | ±5% | 0.95 | 0.8 | 0.6 | 0.3 | 5 7/8" | 1 1/2" | 1 3/8" | Rubber | CE Marked | Yes | 4006K41 | 000000 | |
Thermometer Insulating Tubes
![]() |
Material | Each | ||
|---|---|---|---|
| Plastic | 4680N119 | 000000 |
Infrared Thermometer Transmitter Covers
![]() |
Material | Each | ||
|---|---|---|---|
| 304 Stainless Steel | 4680N118 | 0000000 |
Motion-Sensing Modules for Development Boards
Modules with Fixed Infrared Sensor
Output Data | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensing Distance, m | Field of View | Accuracy | Resolution, bit | Freq., Hz | Temp. Range, ° F | Input Voltage, V DC | I2C Address | Connection Method | No. of Qwiic Connections | Lg. | Wd. | Each | |||
I²C Communication Protocol—Qwiic Connection | |||||||||||||||
| 4 | 80° | ±0.3° C | 16 | 30 | -40 to 185 | 1.7 to 3.6 | 0x5A | Solder | 2 | 1" | 1" | 8194N12 | 000000 | ||
Infrared Thermometer Transmitter Cooling Jackets
![]() |
Material | Each | ||
|---|---|---|---|
| 304 Stainless Steel | 4680N117 | 0000000 |
Noncontact Forehead Thermometers
Batteries | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Resolution/Temp. Resolution | Accuracy | Max. Distance | Response Time, sec. | Ht. | Dp. | Housing Material | Thermometer Features | Certification | Specs. Met | Included | No. of | Cannot Be Sold To | Each | |||
| 95° F to 107° F/35° C to 42° C | 0.1° F/0.1° C | ±0.4° F/±0.2° C | 1" | 1 | 5" | 1 1/2" | Plastic | Backlit Display | FDA Class II Medical Device | ISO 13485 | Yes | 1 | Canada | 6733N1 | 000000 | ||
Hazardous Location Infrared Thermometers
Batteries | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Resolution/Temp. Resolution | Accuracy | Max. Distance, ft. | Emissivity | Response Time, sec. | Ht. | Wd. | Dp. | Housing Material | Includes | Thermometer Features | Hazardous Location Rating | Certification | Included | Size | No. of | Each | |||
For Dark, Dull, Light, and Shiny Surfaces | ||||||||||||||||||||
Adjustable Emissivity | ||||||||||||||||||||
| -40° F to 1,472° F/-40° C to 800° C | 0.1/0.1° C | ±1% | 30 | 0.1 to 1 | 0.5 | 7" | 2" | 6 1/2" | Plastic | Carrying Case | Automatic Shutoff, Laser Sight | ATEX II 2 G Ex Ia IIC T4 Gb Ex Ia IIC T4 IEC Zone 1 Groups IIC, IIB, IIA IECEx Ex Ia IIC T4 Gb NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Zone 1 Groups IIC, IIB, IIA AEx Ia IIC T4 | C-ETL Listed, CE Marked, ETL Listed | Yes | AAA | 2 | 2970N11 | 000000000 | ||
Pocket Infrared Thermometers with Calibration Certificate
Batteries | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Temp. Range | Resolution/Temp. Resolution | Accuracy | Max. Distance | Emissivity | Response Time, sec. | Ht. | Wd. | Dp. | Housing Material | Thermometer Features | Certification | Included | Size | No. of | Each | |||
For Dark Surfaces | |||||||||||||||||||
Fixed Emissivity | |||||||||||||||||||
| A | -7° F to 230° F/-22° C to 110° C | 0.1/0.1° C | ±2.7° F/±1.5° C | 1" | 0.95 | 1 | 2 1/2" | 1 1/2" | 1/2" | Plastic | Automatic Shutoff | CE Marked | Yes | CR2032 | 1 | 9203T75 | 000000 | ||
For Dark, Light, and Shiny Surfaces | |||||||||||||||||||
Fixed Emissivity | |||||||||||||||||||
| B | -27° F to 428° F/-33° C to 220° C | 0.1/0.1° C | ±1.8° F/±1.0° C | 1" | 0.95 | 1 | 3 1/4" | 2 1/2" | 3/4" | Plastic | Pocket Clip | CE Marked | Yes | — | 2 | 9233T46 | 00000 | ||
Adjustable Emissivity | |||||||||||||||||||
| C | -67° F to 482° F/-55° C to 250° C | 0.1/0.1° C | ±2° F/±1° C | 6" | 0.05 to 1 | 1 | 4" | 2" | 3/4" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | CR2032 | 1 | 9233T44 | 00000 | ||
| C | -30° F to 430° F/-33° C to 220° C | 0.5° F/0.2° C | ±4° F/±2° C | 1" | 0.05 to 1 | 1 | 1 1/2" | 2 1/2" | 1/2" | Plastic | Data Hold, Min./Max. Memory | CE Marked | Yes | — | 1 | 9233T47 | 00000 | ||
Noncontact Temperature Sensors for Tanks
For Tank | M12 Male Electrical Connection | Mounting Holes | Mounting Slots | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wall Thk. | Min. Dia., ft. | Temp. Measurement Range, ° F | Accuracy | Response Time, sec. | Ht. | Wd. | Dp. | No. of Poles | Coding | Housing Material | Operating Temp. Range, ° F | Mounting Fasteners Included | No. of | Dia. | No. of | Wd. | Enclosure Rating | Electrical Connection Gender | Each | |||
4 mA to 20 mA Output Signal | ||||||||||||||||||||||
| 1/8" | 2 | -4 to 212 | ±0.9° F | 5 | 4 3/8" | 2 5/8" | 1 5/8" | 8 | A | Nylon | 32 to 100 | Yes | 1 | 5/16" | 1 | 5/16" | IP67 | Male | 5753N11 | 0000000 | ||
Clamp-On Noncontact Temperature Sensors for Pipe
For Pipe | M12 Male Electrical Connection | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | Schedule | Temp. Measurement Range, ° F | Accuracy | Response Time, sec. | Ht. | Wd. | Dp. | No. of Poles | Coding | Housing Material | Operating Temp. Range, ° F | Enclosure Rating | Electrical Connection Gender | Each | |||
4 mA to 20 mA Output Signal | |||||||||||||||||
For Metal Pipes | |||||||||||||||||
| 1 | 40 | -4 to 212 | ±0.9° F | 5 | 2 3/8" | 2 1/2" | 2" | 8 | A | Nylon | 32 to 100 | IP67 | Male | 5780N11 | 0000000 | ||
| 2 | 40 | -4 to 212 | ±0.9° F | 5 | 2 3/8" | 2 1/2" | 2" | 8 | A | Nylon | 32 to 100 | IP67 | Male | 5780N13 | 000000 | ||
| 2 1/2 | 40 | -4 to 212 | ±0.9° F | 5 | 2 3/8" | 2 1/2" | 1 7/8" | 8 | A | Nylon | 32 to 100 | IP67 | Male | 5780N15 | 000000 | ||
| 3 | 40 | -4 to 212 | ±0.9° F | 5 | 2 3/8" | 2 1/2" | 1 7/8" | 8 | A | Nylon | 32 to 100 | IP67 | Male | 5780N16 | 000000 | ||
| 4 | 40 | -4 to 212 | ±0.9° F | 5 | 2 3/8" | 2 1/2" | 1 7/8" | 8 | A | Nylon | 32 to 100 | IP67 | Male | 5780N17 | 000000 | ||
For Plastic Pipes | |||||||||||||||||
| 1 | 40 | -4 to 212 | ±2.7° F | 30 | 2 3/8" | 2 1/2" | 2" | 8 | A | Nylon | 32 to 100 | IP67 | Male | 5780N12 | 000000 | ||
| 2 | 40 | -4 to 212 | ±2.7° F | 30 | 2 3/8" | 2 1/2" | 2" | 8 | A | Nylon | 32 to 100 | IP67 | Male | 5780N14 | 000000 | ||