McMaster-Carr logo
    Filter by
    Volume (Sound)
    Industrial Info Snippet
    Air Outlet Connection Port
    Air Outlet Thread Type
    Industrial Info Compare
    Airflow Control
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Air Outlet Gender
    Thread Type
    Industrial Info Compare
    Performance
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    19 Products

    Quiet Blowguns

    Image of Product. Front orientation. Blowguns. Quiet Blowguns , Straight with Straight Nozzle.
    Image of Product. Front orientation. Blowguns. Quiet Blowguns , Pistol with Straight Nozzle.

    Straight with Straight

    Nozzle

    Pistol with

    Straight Nozzle

    Designed to reduce noise, these blowguns are quieter than similar standard guns. They conform to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure. Volume (dB) is measured 3 ft. from the blowgun at 100 psi.
    Blowguns
    Replacement
    Blowgun Nozzles
    Air Inlet
    Nozzle
    Lg.
    Air Consumption
    @ Pressure
    Volume (Sound),
    dB
    Max. Inlet
    Pressure, psi
    Pipe
    Size
    Thread
    Type
    Gender
    Body
    Material
    Nozzle Tip
    Material
    Grip
    Style
    Specs. Met
    Each
    Each
    Straight with Straight Nozzle
     
    Lever Control
    3 5/8"19 ft³/min @ 100 psi891201/4
    NPT
    FemaleAluminumAluminum
    PlainOSHA Compliant 29 CFR 1910.24254615K36000000———0
     
    Pistol with Straight Nozzle
     
    Trigger Control
    1"21 ft³/min @ 100 psi931201/4
    NPT
    FemaleAluminumAluminum
    PlainOSHA Compliant 29 CFR 1910.24254615K350000054615K21000000
     

    Quiet Long-Reach Blowguns

    Image of Product. Front orientation. Blowguns. Quiet Long-Reach Blowguns .
    Designed to reduce noise, these blowguns are quieter than similar standard guns. Use the extra length to access hard-to-reach areas. Blowguns conform to OSHA 29 CFR 1910.242 requirements for maximum air outlet pressure. Volume (dB) is measured 3 ft. from the blowgun at 100 psi.
    Blowguns
    Replacement
    Blowgun Nozzles
    Air Inlet
    Nozzle
    Lg.
    Air Consumption
    @ Pressure
    Volume (Sound),
    dB
    Max. Inlet
    Pressure, psi
    Pipe
    Size
    Thread
    Type
    Gender
    Body
    Material
    Nozzle Tip
    Material
    Grip
    Style
    Specs. Met
    Each
    Each
    Pistol with Straight Nozzle
     
    Trigger Control
    6"29 ft³/min @ 100 psi991201/4
    NPT
    FemaleAluminumAluminum
    PlainOSHA Compliant 29 CFR 1910.2428316K310000008316K61000000
    12"29 ft³/min @ 100 psi991201/4
    NPT
    FemaleAluminumAluminum
    PlainOSHA Compliant 29 CFR 1910.2428316K32000008316K6200000
    18"29 ft³/min @ 100 psi991201/4
    NPT
    FemaleAluminumAluminum
    PlainOSHA Compliant 29 CFR 1910.2428316K33000008316K6300000
    24"29 ft³/min @ 100 psi991201/4
    NPT
    FemaleAluminumAluminum
    PlainOSHA Compliant 29 CFR 1910.2428316K34000008316K6400000
    36"29 ft³/min @ 100 psi991201/4
    NPT
    FemaleAluminumAluminum
    PlainOSHA Compliant 29 CFR 1910.2428316K35000008316K6500000
    48"29 ft³/min @ 100 psi991201/4
    NPT
    FemaleAluminumAluminum
    PlainOSHA Compliant 29 CFR 1910.2428316K36000008316K6600000
    60"29 ft³/min @ 100 psi991201/4
    NPT
    FemaleAluminumAluminum
    PlainOSHA Compliant 29 CFR 1910.2428316K37000008316K6700000
    72"29 ft³/min @ 100 psi991201/4
    NPT
    FemaleAluminumAluminum
    PlainOSHA Compliant 29 CFR 1910.2428316K38000008316K6800000
     
    back to top