High-Starting-Current Vehicle Relays


Relay Socket and
Surface Mounting


Crimp-On
Terminals
These relays handle the high starting (inrush) currents that often occur when turning on a vehicle. Also known as ISO relays, their blade terminals meet ISO 8092-1 dimensional standards to fit in road vehicles for easy maintenance and repair.
Relays for surface mounting have a tab for added security in high-vibration applications.
Relays with surge suppression coverage prevent damage to sensitive equipment by reducing the 300V to 500V spike that happens when you switch relays off. Relays with full surge suppression coverage eliminate the voltage spike.
Relays with dual output let you control two separate loads or circuits independently. For example, in a car window, these relays could control it moving up and down.
Relays | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Relay Sockets with Crimp-On Terminals | Relay Sockets with Wire Leads | ||||||||||||||
| Number of Terminals | Input Voltage | Off (Normally Open) Circuit Position | On (Normally Closed) Circuit Position | Max. Switching Voltage | Max. Starting Current, A | Control Current, mA | Surge Suppression Coverage | Relay Terminal Layout | Quick-Disconnect Tab Wd. | Features | Each | Each | Each | |||
For Relay Socket | ||||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||||||||
| 5 | 24V DC | 20 A @ 24 V DC | __ | 40V DC | 120 | 69 | __ | Type B | 0.25" | Dual Output | 9672K33 | 000000 | 8228K42 | 00000 | 8228K13 | 000000 |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||||
| 5 | 24V DC | 20 A @ 24 V DC | 10 A @ 24 V DC | 40V DC | 120 | 69 | __ | Type B | 0.25" | __ | 9672K118 | 00000 | 8228K42 | 0000 | 8228K13 | 00000 |
For Relay Socket and Surface Mounting | ||||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||||
| 5 | 24V DC | 20 A @ 24 V DC | 10 A @ 24 V DC | 40V DC | 120 | 69 | __ | Type B | 0.25" | __ | 9672K121 | 00000 | 8228K42 | 0000 | 8228K14 | 00000 |
| 5 | 24V DC | 20 A @ 24 V DC | 10 A @ 24 V DC | 40V DC | 120 | 69 | Full | Type B | 0.25" | __ | 9672K119 | 00000 | 8228K42 | 0000 | 8228K14 | 00000 |
Wireless Enclosed Relays

Send a signal to turn equipment on and off from up to 150 feet away without having to run electrical wire. These relays have an enclosure to protect the terminals from dust and accidental bumps. They can be set to transmit, receive, or both at once. You’ll need at least two relays to switch a device. They have an alarm that can be set to check for certain conditions before transmitting a signal. For example, you could set these relays to send a signal to turn on an air conditioner if all windows are closed. The repeat function extends the transmitting signal through a maximum of two receiving relays.
Relays that are set to transmit can be linked up to as many receiving relays as you need. Relays set to receive can be linked up to 30 transmitting relays. All relays connect to dry contacts on your switch, sensor, or controller. Use the wire leads to connect them to a power source.
UL and C-UL listed, all meet American and Canadian safety standards. Rated NEMA 1, they should only be used indoors.
Wire Lead | Conduit Connection | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Input Voltage | Control Current | Switching Current @ 277V AC | Maximum Switching Voltage | hp @ Switching Voltage | Ht. | Wd. | Dp. | Maximum Transmission Distance, ft. | Lg. | Number of | Gender | Trade Size | Thread Type | Environmental Rating | Each | |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||||
| 24V AC, 24V DC | 69 | 20A | 277V AC | 2 hp @ 277 V AC | 2.3" | 3.2" | 1.8" | 150 | 16" | 7 | Male | 1/2 | NPT | NEMA 1 | 3918N15 | 0000000 |