    74 Products

    Motor Starters

    Image of Product. Front orientation. Motor Starters. Motor Starters .
    Provide on/off control for a motor and protect it from overloads. These starters shut off the motor if current exceeds the full-load current rating. All have an adjustable overload relay that allows you to set the exact overload current you need.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
    Auxiliary Contact Switch Starting Position—Starters with auxiliary contacts can send a signal or connect to another device, such as an alarm or indicating light.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Ht.
    Wd.
    Mounting
    Location
    For DIN
    Rail Ht., mm
    Specs.
    Met
    Each
    Each
    Each
    Motor Starters
    20 to 100200/240Single (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"2.2"DIN Rail35IEC 609477603K17600000007603K2980000007603K299000000
     
    Motor Starters with 1 Auxiliary Contact—1 Off
    1 to 5200/240Single (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    5.6"1.8"DIN Rail35IEC 609477603K1370000007603K296000007603K29700000
    1.1 to 1.6200/240Three (1/2 hp @ 480V AC)
    Three (3/4 hp @ 480V AC)
    4.7"1.8"DIN Rail357603K1830000007603K8000007603K900000
    1.8 to 2.5200/240Three (1/2 hp @ 230V AC)
    Three (1 hp @ 480V AC)
    4.7"1.8"DIN Rail357603K1930000007603K8000007603K900000
    2.3 to 3.2200/240Single (1/4 hp @ 230V AC)
    Three (3/4 hp @ 230V AC
    Three (1 1/2 hp @ 480V AC)
    4.7"1.8"DIN Rail357603K2130000007603K8000007603K900000
    3.5 to 4.8200/240Single (1/6 hp @ 115V AC)
    Single (1/3 hp @ 230V AC)
    Three (1 hp @ 230V AC,)
    Three (3 hp @ 480V AC)
    4.7"1.8"DIN Rail357603K2230000007603K8000007603K900000
    4 to 20200/240Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    5.6"1.8"DIN Rail35IEC 609477603K1480000007603K296000007603K29700000
    5.5 to 7.5200/240Single (1/3 hp @ 115V AC)
    Single (3/4 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 480V AC)
    4.7"1.8"DIN Rail357603K2330000007603K8000007603K900000
    9 to 12.5200/240Single (1/2 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (7 1/2 hp @ 480V AC)
    4.7"1.8"DIN Rail357603K2430000007603K8000007603K900000
    9 to 45200/240Single (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    6.3"1.8"DIN Rail35IEC 609477603K1590000007603K296000007603K29700000
    11.3 to 16200/240Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (5 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    4.7"1.8"DIN Rail357603K2630000007603K8000007603K900000
     
    Motor Starters with 2 Auxiliary Contacts—1 Off, 1 On
    17.5 to 21.5200/240Single (1 1/2 hp @ 115V AC)
    Single (3 hp @ 230V AC)
    Three (7 1/2 hp @ 230V AC)
    Three (15 hp @ 480V AC)
    4.9"2.2"DIN Rail357603K2730000007603K8000007603K900000
    24.5 to 30200/240Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    4.9"2.2"DIN Rail357603K2830000007603K8000007603K900000
    24.5 to 36200/240Single (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (25 hp @ 480V AC)
    5.9"2.7"DIN Rail357603K2930000007603K8000007603K900000
    35 to 47200/240Single (7 1/2 hp @ 230V AC)
    Three (15 hp @ 230V AC)
    Three (30 hp @ 480V AC)
    5.9"2.7"DIN Rail357603K1130000007603K8000007603K900000
     
    Motor Starters with 4 Auxiliary Contacts—2 Off, 2 On
    45 to 60200/240Single (5 hp @ 115V AC)
    Single (10 hp @ 230V AC)
    Three (20 hp @ 230V AC)
    Three (40 hp @ 480V AC)
    6.7"3.7"DIN Rail357603K3030000007603K8000007603K900000
    58 to 75200/240Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    6.7"3.7"DIN Rail357603K9430000007603K8000007603K900000
     

    Low-Profile Motor Starters

    Image of Product. Front orientation. Motor Starters. Low-Profile Motor Starters.
    With a shallower depth than most other starters, these fit in narrow spaces. They provide on/off control for a motor and protect it from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Ht.
    Wd.
    Mounting
    Location
    For DIN
    Rail Ht., mm
    Each
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
    1.1 to 1.6200/240Three (1/2 hp @ 480V AC)
    Three (3/4 hp @ 480V AC)
    4.2"1.8"DIN Rail357603K13300000007603K60000007603K7000000
    1.8 to 2.5200/240Three (1/2 hp @ 230V AC)
    Three (1 hp @ 480V AC)
    4.2"1.8"DIN Rail357603K1430000007603K6000007603K700000
    2.3 to 3.2200/240Single (1/4 hp @ 230V AC)
    Three (3/4 hp @ 230V AC
    Three (1 1/2 hp @ 480V AC)
    4.2"1.8"DIN Rail357603K1530000007603K6000007603K700000
    3.5 to 4.8200/240Single (1/6 hp @ 115V AC)
    Single (1/3 hp @ 230V AC)
    Three (1 hp @ 230V AC,)
    Three (3 hp @ 480V AC)
    4.2"1.8"DIN Rail357603K1630000007603K6000007603K700000
    5.5 to 7.5200/240Single (1/3 hp @ 115V AC)
    Single (3/4 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    4.2"1.8"DIN Rail357603K1730000007603K6000007603K700000
     

    Reversing Motor Starters

    Image of Product. Front orientation. Motor Starters. Reversing Motor Starters .
    Use these starters with motors that run forward and backward, such as motors for conveyor belts. They provide on/off control and protect motors from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Ht.
    Wd.
    Mounting
    Location
    For DIN
    Rail Ht., mm
    Specs.
    Met
    Each
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 On
    1.1 to 1.6200/240Three (1/3 hp @ 230V AC)
    Three (3/4 hp @ 480V AC)
    4.7"4"DIN Rail357636K21300000007603K80000007603K9000000
    1.8 to 2.5200/240Three (1/2 hp @ 230V AC)
    Three (1 hp @ 480V AC)
    4.7"4"DIN Rail357636K2230000007603K8000007603K900000
    2.3 to 3.2200/240Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 480V AC)
    4.7"4"DIN Rail357636K2330000007603K8000007603K900000
    3.5 to 4.8200/240Three (1 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    4.7"4"DIN Rail357636K2430000007603K8000007603K900000
    5.5 to 7.5200/240Three (2 hp @ 230V AC)4.7"4"DIN Rail357636K2530000007603K8000007603K900000
    9 to 12.5200/240Three (3 hp @ 230V AC)
    Three (7 1/2 hp @ 480V AC)
    4.7"4"DIN Rail357636K2630000007603K8000007603K900000
    11.3 to 16200/240Three (5 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    4.7"4"DIN Rail357636K2830000007603K8000007603K900000
     
    Motor Starters with 2 Auxiliary Contacts—1 Off, 1 On
    17.5 to 21.5200/240Three (15 hp @ 480V AC)4.9"4.7"DIN Rail357636K2930000007603K8000007603K900000
    20 to 100200/240Single (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"4.4"DIN Rail35IEC 609477636K216000000007603K298000007603K29900000
     
    Motor Starters with 3 Auxiliary Contacts—2 Off, 1 On
    1 to 5200/240Single (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    5.6"3.6"DIN Rail35IEC 609477636K1670000007603K296000007603K29700000
    4 to 20200/240Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    5.6"3.6"DIN Rail35IEC 609477636K1780000007603K296000007603K29700000
    9 to 45200/240Single (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    6.3"3.6"DIN Rail35IEC 609477636K189000000007603K296000007603K29700000
     

    Enclosed Motor Starters

    Image of Product. Front orientation. Motor Starters. Enclosed Motor Starters.
    The NEMA 4X rated enclosure protects these starters from corrosion and washdowns. They provide on/off control for a motor and protect it from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
    1 to 5200/240Single (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K18700000007603K2960000007603K297000000
    1.1 to 1.6200/240Three (1/2 hp @ 480V AC)
    Three (3/4 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K3730000007603K8000007603K900000
    1.8 to 2.5200/240Three (1/2 hp @ 230V AC)
    Three (1 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K3930000007603K8000007603K900000
    2.3 to 3.2200/240Single (1/4 hp @ 230V AC)
    Three (3/4 hp @ 230V AC
    Three (1 1/2 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K4130000007603K8000007603K900000
    3.5 to 4.8200/240Single (1/6 hp @ 115V AC)
    Single (1/3 hp @ 230V AC)
    Three (1 hp @ 230V AC,)
    Three (3 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K4230000007603K8000007603K900000
    4 to 20200/240Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K1980000007603K296000007603K29700000
    5.5 to 7.5200/240Single (1/3 hp @ 115V AC)
    Single (3/4 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K5130000007603K8000007603K900000
    9 to 12.5200/240Single (1/2 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (7 1/2 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K5230000007603K8000007603K900000
    9 to 45200/240Single (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    9.5"6.19"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K2390000007603K296000007603K29700000
    11.3 to 16200/240Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (5 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K4630000007603K8000007603K900000
    17.5 to 21.5200/240Single (1 1/2 hp @ 115V AC)
    Single (3 hp @ 230V AC)
    Three (7 1/2 hp @ 230V AC)
    Three (15 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K4730000007603K8000007603K900000
    24.5 to 30200/240Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K4830000007603K8000007603K900000
    24.5 to 36200/240Single (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (25 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K4930000007603K8000007603K900000
    35 to 47200/240Single (7 1/2 hp @ 230V AC)
    Three (15 hp @ 230V AC)
    Three (30 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K1230000007603K8000007603K900000
    45 to 60200/240Single (5 hp @ 115V AC)
    Single (10 hp @ 230V AC)
    Three (20 hp @ 230V AC)
    Three (40 hp @ 480V AC)
    11.8"8.7"NEMA 4X, IP55
    UL Recognized Component
    7603K9330000007603K8000007603K900000
    58 to 75200/240Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    11.8"8.7"NEMA 4X, IP55
    UL Recognized Component
    7603K9630000007603K8000007603K900000
     
    Motor Starters with 2 Auxiliary Contacts—1 Off, 1 On
    20 to 100200/240Single (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    11.7"9.3"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477603K276000000007603K298000007603K29900000
     

    Compact Enclosed Motor Starters

    Image of Product. Front orientation. Motor Starters. Compact Enclosed Motor Starters.
    Sized to fit in tight spaces, these starters have a shorter height and narrower depth than most other starters. A NEMA 4X rated enclosure protects them from corrosion and washdowns. They provide on/off control for a motor and protect it from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    Each
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
    1.1 to 1.6200/240Three (1/2 hp @ 480V AC)
    Three (3/4 hp @ 480V AC)
    5.9"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K31300000007603K60000007603K7000000
    1.8 to 2.5200/240Three (1/2 hp @ 230V AC)
    Three (1 hp @ 480V AC)
    5.9"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K3230000007603K6000007603K700000
    2.3 to 3.2200/240Single (1/4 hp @ 230V AC)
    Three (3/4 hp @ 230V AC
    Three (1 1/2 hp @ 480V AC)
    5.9"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K3330000007603K6000007603K700000
    3.5 to 4.8200/240Single (1/6 hp @ 115V AC)
    Single (1/3 hp @ 230V AC)
    Three (1 hp @ 230V AC,)
    Three (3 hp @ 480V AC)
    5.9"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K3430000007603K6000007603K700000
    5.5 to 7.5200/240Single (1/3 hp @ 115V AC)
    Single (3/4 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    5.9"5.9"NEMA 4X, IP55
    UL Recognized Component
    7603K3530000007603K6000007603K700000
     

    Enclosed Reversing Motor Starters

    Image of Product. Front orientation. Motor Starters. Enclosed Reversing Motor Starters.
    Rated NEMA 4X, these enclosed starters are protected from corrosion and washdowns. Use them with motors that run forward and backward, such as motors for conveyor belts. They provide on/off control and protect motors from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 On
    1.1 to 1.6200/240Three (1/3 hp @ 230V AC)
    Three (3/4 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7636K31300000007603K80000007603K9000000
    1.8 to 2.5200/240Three (1/2 hp @ 230V AC)
    Three (1 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7636K3230000007603K8000007603K900000
    2.3 to 3.2200/240Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7636K3330000007603K8000007603K900000
    3.5 to 4.8200/240Three (1 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7636K3430000007603K8000007603K900000
    5.5 to 7.5200/240Three (2 hp @ 230V AC)8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7636K3530000007603K8000007603K900000
    9 to 12.5200/240Three (3 hp @ 230V AC)
    Three (7 1/2 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7636K3630000007603K8000007603K900000
    11.3 to 16200/240Three (5 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    8.7"5.9"NEMA 4X, IP55
    UL Recognized Component
    7636K3830000007603K8000007603K900000
     
    Motor Starters with 2 Auxiliary Contacts—1 Off, 1 On
    17.5 to 21.5200/240Three (15 hp @ 480V AC)11.8"8.7"NEMA 4X, IP55
    UL Recognized Component
    7636K3930000007603K8000007603K900000
     
    Motor Starters with 3 Auxiliary Contacts—2 Off, 1 On
    1 to 5200/240Single (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    11"7.9"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477636K2270000007603K296000007603K29700000
    4 to 20200/240Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    11"7.9"NEMA 4X, IP66
    UL Listed, CSA Certified
    IEC 609477636K2380000007603K296000007603K29700000
     
    back to top