    34 Products

    Motor Starters

    Image of Product. Front orientation. Motor Starters. Motor Starters .
    Provide on/off control for a motor and protect it from overloads. These starters shut off the motor if current exceeds the full-load current rating. All have an adjustable overload relay that allows you to set the exact overload current you need.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
    Auxiliary Contact Switch Starting Position—Starters with auxiliary contacts can send a signal or connect to another device, such as an alarm or indicating light.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase (Horsepower
    @ Switching Voltage)
    Aux. Contact Switch
    Starting Position
    Ht.
    Wd.
    Dp.
    Mounting
    Location
    For DIN
    Rail Ht., mm
    Certification
    Specs.
    Met
    Each
    Each
    Each
    1 to 5220/240Single (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    1 Off
    5.6"1.8"4.4"DIN Rail35UL Listed, CE Marked, CSA Certified
    IEC 609477603K13700000007603K2960000007603K297000000
    4 to 20220/240Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    1 Off
    5.6"1.8"4.4"DIN Rail35UL Listed, CE Marked, CSA Certified
    IEC 609477603K1480000007603K296000007603K29700000
    9 to 45220/240Single (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    1 Off
    6.3"1.8"4.4"DIN Rail35UL Listed, CE Marked, CSA Certified
    IEC 609477603K1590000007603K296000007603K29700000
    20 to 100220/240Single (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    8.3"2.2"5.3"DIN Rail35UL Listed, CE Marked, CSA Certified
    IEC 609477603K1760000007603K298000007603K29900000
     

    Heavy Duty Motor Starters

    Image of Product. Front orientation. Motor Starters. Heavy Duty Motor Starters.
    Sealed coils protect these starters against moisture, heat, dirt, and mechanical and thermal stress. They have a solid state overload relay that extends motor life in demanding applications and protects it from overloads—starters will shut the motor off if current exceeds the full-load current rating. The relay is adjustable; set it for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light. Also known as NEMA starters.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    NEMA Contact Size 0 and NEMA Contact Size 1—NEMA contact sizes 0 and 1 are universal mount and fit Cutler-Hammer, GE, and Square D installations.
    Motor Starters
    Replacement
    Coils
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase (Horsepower
    @ Switching Voltage)
    Tripping
    Accuracy
    Aux. Contact Switch
    Starting Position
    Ht.
    Wd.
    Dp.
    Certification
    Each
    Each
    NEMA Contact Size 0
    0.25 to 1220/480Three (1/6 hp @ 200V AC)
    Three (1/6 hp @ 230V AC)
    Three (1/3 hp @ 460V AC)
    Three (1/2 hp @ 575V AC)
    -1% to 1%1 Off
    7.4"4.3"3.8"UL Listed, CSA Certified
    7463K32400000007463K7140000000
    0.75 to 3.4220/480Three (1/2 hp @ 200V AC)
    Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 460V AC)
    Three (2 hp @ 575V AC)
    -1% to 1%1 Off
    7.4"4.3"3.8"UL Listed, CSA Certified
    7463K3340000007463K714000000
    3 to 12220/480Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%1 Off
    7.4"4.3"3.8"UL Listed, CSA Certified
    7463K1240000007463K714000000
    5.5 to 22220/480Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    -1% to 1%1 Off
    7.4"4.3"3.8"UL Listed, CSA Certified
    7463K1340000007463K714000000
     
    NEMA Contact Size 1
    3 to 12220/480Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%1 Off
    7.4"4.3"3.8"UL Listed, CSA Certified
    7463K1540000007463K714000000
    5.5 to 22220/480Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Three (10 hp @ 575V AC)
    -1% to 1%1 Off
    7.4"4.3"3.8"UL Listed, CSA Certified
    7463K1640000007463K714000000
    10 to 40220/480Three (7 1/2 hp @ 200V AC)
    Three (7 1/2 hp @ 230V AC)
    -1% to 1%1 Off
    7.4"4.3"3.8"UL Listed, CSA Certified
    7463K1740000007463K714000000
     
    NEMA Contact Size 2
    13 to 52220/480Three (10 hp @ 200V AC)
    Three (15 hp @ 230V AC)
    Three (25 hp @ 460V AC)
    Three (25 hp @ 575V AC)
    -1% to 1%1 Off
    8.1"4.6"4.1"UL Listed, CSA Certified
    7463K2240000007463K714000000
     

    Reversing Motor Starters

    Image of Product. Front orientation. Motor Starters. Reversing Motor Starters .
    Use these starters with motors that run forward and backward, such as motors for conveyor belts. They provide on/off control and protect motors from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase (Horsepower
    @ Switching Voltage)
    Aux. Contact Switch
    Starting Position
    Ht.
    Wd.
    Dp.
    Mounting
    Location
    For DIN
    Rail Ht., mm
    Certification
    Specs.
    Met
    Each
    Each
    Each
    1 to 5220/240Single (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    1 On, 2 Off
    5.6"3.6"4.6"DIN Rail35UL Listed, CE Marked, CSA Certified
    IEC 609477636K16700000007603K2960000007603K297000000
    4 to 20220/240Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    1 On, 2 Off
    5.6"3.6"4.6"DIN Rail35UL Listed, CE Marked, CSA Certified
    IEC 609477636K1780000007603K296000007603K29700000
    9 to 45220/240Single (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    1 On, 2 Off
    6.3"3.6"5.5"DIN Rail35UL Listed, CE Marked, CSA Certified
    IEC 609477636K189000000007603K296000007603K29700000
    20 to 100220/240Single (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    1 Off, 1 On
    8.3"4.4"5.8"DIN Rail35UL Listed, CE Marked, CSA Certified
    IEC 609477636K216000000007603K298000007603K29900000
     

    Enclosed Heavy Duty Motor Starters

    Image of Product. Front orientation. Motor Starters. Enclosed Heavy Duty Motor Starters.
    Housed in a durable steel enclosure, these starters have sealed coils for protection against moisture, heat, dirt, and mechanical and thermal stress. They have a solid state overload relay that extends motor life in demanding applications and protects it from overloads—starters will shut the motor off if current exceeds the full-load current rating. The relay is adjustable; set it for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light. Also known as NEMA starters.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    NEMA Contact Size 0 and NEMA Contact Size 1—NEMA contact sizes 0 and 1 are universal mount and fit Cutler-Hammer, GE, and Square D installations.
    Motor Starters
    Replacement
    Coils
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase (Horsepower
    @ Switching Voltage)
    Tripping
    Accuracy
    Aux. Contact Switch
    Starting Position
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Each
    NEMA Contact Size 0
    0.75 to 3.4220/480Three (1/2 hp @ 200V AC)
    Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 460V AC)
    Three (2 hp @ 575V AC)
    -1% to 1%1 Off
    11"6.4"5"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K35400000007463K7140000000
    3 to 12220/480Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%1 Off
    11"6.4"5"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4240000007463K714000000
    5.5 to 22220/480Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    -1% to 1%1 Off
    11"6.4"5"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4340000007463K714000000
     
    NEMA Contact Size 1
    3 to 12220/480Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%1 Off
    11"6.4"5"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4540000007463K714000000
    5.5 to 22220/480Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Three (10 hp @ 575V AC)
    -1% to 1%1 Off
    11"6.4"5"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4640000007463K714000000
    10 to 40220/480Three (7 1/2 hp @ 200V AC)
    Three (7 1/2 hp @ 230V AC)
    -1% to 1%1 Off
    11"6.4"5"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4740000007463K714000000
     
    NEMA Contact Size 2
    13 to 52220/480Three (10 hp @ 200V AC)
    Three (15 hp @ 230V AC)
    Three (25 hp @ 460V AC)
    Three (25 hp @ 575V AC)
    -1% to 1%1 Off
    13.5"8"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K524000000007463K714000000
     

    Enclosed Reversing Motor Starters

    Image of Product. Front orientation. Motor Starters. Enclosed Reversing Motor Starters.
    Rated NEMA 4X, these enclosed starters are protected from corrosion and washdowns. Use them with motors that run forward and backward, such as motors for conveyor belts. They provide on/off control and protect motors from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload
    Current, amp
    Input Voltage,
    V AC
    Electrical Phase (Horsepower
    @ Switching Voltage)
    Aux. Contact Switch
    Starting Position
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Each
    Each
    1 to 5220/240Single (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    1 On, 2 Off
    11"7.9"6.3"NEMA 4X, IP66
    UL Listed, CE Marked, CSA Certified
    IEC 609477636K22700000007603K2960000007603K297000000
    4 to 20220/240Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    1 On, 2 Off
    11"7.9"6.3"NEMA 4X, IP66
    UL Listed, CE Marked, CSA Certified
    IEC 609477636K2380000007603K296000007603K29700000
     

    Enclosed Motor Starters

    Image of Product. Front orientation. Motor Starters. Enclosed Motor Starters.
    The NEMA 4X rated enclosure protects these starters from corrosion and washdowns. They provide on/off control for a motor and protect it from overloads—starters will shut the motor off if current exceeds the full-load current rating. Set the adjustable overload relay for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    Add auxiliary contact blocks to signal more devices.
    Motor Starters
    Auxiliary Contact
    Blocks: 2 Off
    Auxiliary Contact
    Blocks: 1 Off, 1 On
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase (Horsepower
    @ Switching Voltage)
    Aux. Contact Switch
    Starting Position
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Each
    Each
    1 to 5220/240Single (1/4 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    Three (2 hp @ 230V AC)
    Three (3 hp @ 480V AC)
    1 Off
    9.5"6.19"6.3"NEMA 4X, IP66
    UL Listed, CE Marked, CSA Certified
    IEC 609477603K18700000007603K2960000007603K297000000
    4 to 20220/240Single (1 hp @ 115V AC)
    Single (2 hp @ 230V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 480V AC)
    1 Off
    9.5"6.19"6.3"NEMA 4X, IP66
    UL Listed, CE Marked, CSA Certified
    IEC 609477603K1980000007603K296000007603K29700000
    9 to 45220/240Single (3 hp @ 115V AC)
    Single (5 hp @ 230V AC)
    Three (10 hp @ 230V AC)
    Three (20 hp @ 480V AC)
    1 Off
    9.5"6.19"6.3"NEMA 4X, IP66
    UL Listed, CE Marked, CSA Certified
    IEC 609477603K2390000007603K296000007603K29700000
    20 to 100220/240Single (5 hp @ 115V AC)
    Single (15 hp @ 230V AC)
    Three (25 hp @ 230V AC)
    Three (50 hp @ 480V AC)
    1 Off, 1 On
    11.7"9.3"6.9"NEMA 4X, IP66
    UL Listed, CE Marked, CSA Certified
    IEC 609477603K276000000007603K298000007603K29900000
     