    1 Product

    Safety Relays

    Receive signals from safety monitoring relays or controllers to switch devices off and on because of a system failure. Also known as force-guided or mechanically linked contacts, the interlocking opposing contacts on these relays cannot be open or closed at the same time. To keep your system from receiving false switching signals, the interlocking opposing contact must remain open even if a contact welds closed.
    IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits. These relays have been tested to safety standards that can help you achieve your system's PL (performance level) and SIL (safety integrity level). Choose a relay with a PL and SIL rating to meet the needs of your system. Higher ratings indicate greater safety protection. As your system becomes more complex, you generally require a higher safety protection level. Mount them to 35mm DIN rail (also known as DIN 3 Rail).
    SIL 2, PLd Max. System Safety Rating—DIN-Rail Mount
    Image of Product. Bottom orientation. Contains Annotated. Safety Relays. Safety Relays, SIL 2, PLd Max. System Safety Rating—DIN-Rail Mount.
    Relays that meet SIL 2 are tested for applications with a probability of failure of 0.1% to 1%. They’re often used for emergency shutdowns, and fire, gas, and overpressure detection.
    No. of
    Terminals
    Input Voltage,
    V DC
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    Ht.
    Wd.
    Dp.
    Features
    Each
    Screw-Terminal Wire Connection
     
    3 Circuits Controlled with 2 Off and 1 On—3PST-2NO/1NC
    8242610 amp @ 240V AC2503.5"0.7"2.4"Interlocked Opposing Contacts, LED Indicator, Recessed Terminals6242N111000000
    Safety Relay with Screw Terminals, 3PST-2NO/1NC, 24V DC Input
    EachIn stock
     
    back to top