    32 Products

    Compact Spade-Terminal Relays

    Image of Product. 11-Terminal Relay. Front orientation. Contains Annotated. Relays. Compact Spade-Terminal Relays, 3 Circuits Controlled, 1.2" Wide, 1.6" Deep.
    Image of Product. 14-Terminal Relay. Front orientation. Contains Annotated. Relays. Compact Spade-Terminal Relays, 4 Circuits Controlled, 1.6" Deep.
    Image of Product. 11-Terminal Relay Socket. Front orientation. Relay Sockets. Compact Spade-Terminal Relays.

    11-Terminal Relay

    14-Terminal Relay

    11-Terminal

    Relay Socket

    Image of Product. 14-Terminal Relay Socket. Front orientation. Relay Sockets. Compact Spade-Terminal Relays.
    Image of Product. 8-Terminal Relay Socket. Front orientation. Relay Sockets. Compact Spade-Terminal Relays.

    14-Terminal

    Relay Socket

    8-Terminal

    Relay

    Socket

    Fit these relays where standard spade-terminal relays are too big. You can connect them three ways. Plug them into a socket (sold separately), connect them with quick-disconnect terminals, or solder wires directly to the terminals. An LED indicator shows you the status of the relay, so you know it’s connected and wired correctly.
    2 Circuits Controlled, 3 Circuits Controlled, and 4 Circuits Controlled—Relays that control 2 or more circuits have a lockable test button, so you can test their function. When you press the button, the relay switches contacts. Use this button when checking a relay for proper function before installing it, or when investigating issues with wired relays.
    Sockets with Screw Terminals—Relay sockets mount directly on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. You can also mount them to a flat surface using screws.
    Relays
    Sockets with
    Screw Terminals
    No. of
    Terminals
    Input
    Voltage
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    hp @ Switching Voltage
    Ht.
    Wd.
    Dp.
    Quick-Disconnect
    Tab Wd.
    Features
    Each
    Each
    2 Circuits Controlled with 2 Off or 2 On—DPDT
     
    Relay-Socket Mount
    824V AC5015 amp @ 120V AC
    12 amp @ 24V DC
    3001/2 hp @ 120V AC
    1 hp @ 277V AC
    1.1"0.9"1.6"0.187"LED Indicator, Lockable Test Button, Mechanical Flag Indicator69585K5700000069585K100000
    8120V AC1015 amp @ 120V AC
    12 amp @ 24V DC
    3001/2 hp @ 120V AC
    1 hp @ 277V AC
    1.1"0.9"1.6"0.187"LED Indicator, Lockable Test Button, Mechanical Flag Indicator69585K580000069585K10000
    8240V AC515 amp @ 120V AC
    12 amp @ 24V DC
    3001/2 hp @ 120V AC
    1 hp @ 277V AC
    1.1"0.9"1.6"0.187"LED Indicator, Lockable Test Button, Mechanical Flag Indicator69585K590000069585K10000
    812V DC7515 amp @ 120V AC
    12 amp @ 24V DC
    3001/2 hp @ 120V AC
    1 hp @ 277V AC
    1.1"0.9"1.6"0.187"LED Indicator, Lockable Test Button, Mechanical Flag Indicator69585K660000069585K10000
    824V DC3815 amp @ 120V AC
    12 amp @ 24V DC
    3001/2 hp @ 120V AC
    1 hp @ 277V AC
    1.1"0.9"1.6"0.187"LED Indicator, Lockable Test Button, Mechanical Flag Indicator69585K670000069585K10000
     
    3 Circuits Controlled with 3 Off or 3 On—3PDT
     
    Relay-Socket Mount
    1124V AC6315 amp @ 120V AC
    12 amp @ 24V DC
    3001/2 hp @ 120V AC
    1 hp @ 277V AC
    1.1"1.2"1.6"0.187"LED Indicator, Lockable Test Button, Mechanical Flag Indicator69585K680000069585K200000
    11120V AC1315 amp @ 120V AC
    12 amp @ 24V DC
    3001/2 hp @ 120V AC
    1 hp @ 277V AC
    1.1"1.2"1.6"0.187"LED Indicator, Lockable Test Button, Mechanical Flag Indicator69585K690000069585K200000
    11240V AC615 amp @ 120V AC
    12 amp @ 24V DC
    3001/2 hp @ 120V AC
    1 hp @ 277V AC
    1.1"1.2"1.6"0.187"LED Indicator, Lockable Test Button, Mechanical Flag Indicator69585K710000069585K200000
    1112V DC11715 amp @ 120V AC
    12 amp @ 24V DC
    3001/2 hp @ 120V AC
    1 hp @ 277V AC
    1.1"1.2"1.6"0.187"LED Indicator, Lockable Test Button, Mechanical Flag Indicator69585K720000069585K200000
    1124V DC5815 amp @ 120V AC
    12 amp @ 24V DC
    3001/2 hp @ 120V AC
    1 hp @ 277V AC
    1.1"1.2"1.6"0.187"LED Indicator, Lockable Test Button, Mechanical Flag Indicator69585K730000069585K200000
     
    4 Circuits Controlled with 4 Off or 4 On—4PDT
     
    Relay-Socket Mount
    1424V AC6315 amp @ 120V AC
    12 amp @ 24V DC
    3001/2 hp @ 120V AC
    1 hp @ 277V AC
    1.1"1.6"1.6"0.187"LED Indicator, Lockable Test Button, Mechanical Flag Indicator69585K740000069585K300000
    14120V AC1315 amp @ 120V AC
    12 amp @ 24V DC
    3001/2 hp @ 120V AC
    1 hp @ 277V AC
    1.1"1.6"1.6"0.187"LED Indicator, Lockable Test Button, Mechanical Flag Indicator69585K790000069585K300000
    1412V DC12515 amp @ 120V AC
    12 amp @ 24V DC
    3001/2 hp @ 120V AC
    1 hp @ 277V AC
    1.1"1.6"1.6"0.187"LED Indicator, Lockable Test Button, Mechanical Flag Indicator69585K550000069585K300000
    1424V DC615 amp @ 120V AC
    12 amp @ 24V DC
    3001/2 hp @ 120V AC
    1 hp @ 277V AC
    1.1"1.6"1.6"0.187"LED Indicator, Lockable Test Button, Mechanical Flag Indicator69585K960000069585K300000
     

    Hazardous Location Relays

    Image of Product. Front orientation. Contains Annotated. Relays. Hazardous Location Relays, Screw Terminals.
    Image of Product. Front orientation. Relays. Hazardous Location Relays, Spring-Clamp Terminals.

    Screw Terminals

    Spring-Clamp

    Terminals

    Image of Product. Front orientation. Contains Annotated. Relays. Hazardous Location Relays, Circular-Pin Terminals—Hermetically Sealed.
    Image of Product. Front orientation. Relay Sockets. Hazardous Location Relays.

    Circular-Pin

    Terminals—Hermetically

    Sealed

    Sockets with

    Screw Terminals

    Sealed for safety, these relays are a good choice for hazardous locations where combustible or corrosive gases may be present.
    Screw Terminals—Relays with screw terminals are considered interface relays, so they’re placed between your controller and components to isolate the input and output circuits. This means they protect your component from voltage spikes while amplifying the relay’s signal and reducing interference for reliable transmission. They are often used for switching applications, such as small motors and pilot lights. The included relay socket mounts on 35 mm DIN rail (also known as DIN 3 rail).
    Spring-Clamp Terminals—Relays with spring-clamp terminals are considered interface relays, so they’re placed between your controller and components to isolate the input and output circuits. This means they protect your component from voltage spikes while amplifying the relay’s signal and reducing interference for reliable transmission. They are often used for switching applications, such as small motors and pilot lights. The included relay socket mounts on 35 mm DIN rail (also known as DIN 3 rail). Relays with spring-clamp terminals connect and disconnect to wires without needing to turn screws. With no screws to shake loose with vibration, the terminals hold tight over time.
    Circular-Pin Terminal—Relays with circular-pin terminals or quick-disconnect terminals are hermetically sealed—completely air- and watertight—to shield internal parts from gases, moisture, and other contaminants. They plug into relay sockets (sold separately) for easy installation.
    Sockets with Screw Terminals—Relay sockets mount to 35 mm DIN rail (also known as DIN 3 rail) or flat surfaces.
    Relays
    Sockets with
    Screw Terminals
    No. of
    Terminals
    Input Voltage
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    hp @ Switching
    Voltage
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Hazardous Location Rating
    Each
    Each
    Screw Terminals
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    512V AC, 12V DC2912 amp @ 240V AC/24V DC400V AC/300V DC2.9"0.6"3.5"IP20
    NEC Class I Division 2 Groups A, B, C, D
    4190N312000000———0
     
    Spring-Clamp Terminals
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    512V AC, 12V DC2912 amp @ 240V AC/24V DC400V AC/300V DC2.9"0.6"3.7"IP20
    NEC Class I Division 2 Groups A, B, C, D
    8163N1400000———0
    524V AC, 24V DC2012 amp @ 240V AC/24V DC400V AC/300V DC2.9"0.6"3.7"IP20
    NEC Class I Division 2 Groups A, B, C, D
    8163N1500000———0
    5120V AC, 120V DC412 amp @ 240V AC/24V DC400V AC/300V DC2.9"0.6"3.7"IP20
    NEC Class I Division 2 Groups A, B, C, D
    8163N1600000———0
     
    Circular-Pin Terminals—Hermetically Sealed
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    8120V AC1012 amp @ 120V AC/24V DC300V AC1/3 hp @ 120V AC1.6"1.4"2.1"NEC Class I Division 2 Groups A, B, C, D
    7125T320000007125T4100000
    824V DC3812 amp @ 120V AC/24V DC300V AC1/3 hp @ 120V AC1.6"1.4"2.1"NEC Class I Division 2 Groups A, B, C, D
    7125T340000007125T410000
     
    3 Circuits Controlled with 3 Off or 3 On—3PDT
    11120V AC10012 amp @ 120V AC/240V AC300V AC1/3 hp @ 120V AC1.6"1.4"2.1"NEC Class I Division 2 Groups A, B, C, D
    7125T1110000007122K210000
     

    Network-Enabled Relays

    Image of Product. Front orientation. Contains Annotated. Relays. Network-Enabled Relays, 1 Circuit Controlled.

    1 Circuit

    Controlled

    With a built-in web server, these relays can be remotely controlled over any IP network, including the Internet. They connect to your network either wirelessly or with an Ethernet cable (not included). No programming or software is required to operate these relays. Instead, use your web browser to input the relay’s IP address and the website guides you through simple menus and drop-down lists to set your parameters. Alternatively, you can use these relays with a PLC or without a computer at all if you use one relay as a controller for another relay.
    Each circuit has a digital input that can be used to control the relay or a remote relay over the IP network. You could also use the digital input to monitor a separate device, such as a push-button or door alarm switch. These relays can be set to automatically restart network devices, such as computers, even when they fail to respond to relay signals. LED indicators let you know if there’s input and output voltage and if the network is connected and active. All meet at least one safety standard.
    Mount these relays on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They also mount to flat surfaces.
    Power Over Ethernet Standard—Power over Ethernet (PoE) compatible relays can receive power from PoE cables (not included).
    Digital
    Inputs
    Digital
    Outputs
    No. of
    Terminals
    Voltage
    No.
    of
    Voltage
    No.
    of
    Control Current,
    amp
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V DC
    Ht.
    Wd.
    Dp.
    Signal
    Type
    PoE Std.
    Communication
    Protocol
    Operating System Compatibility
    Features
    Each
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    86V DC
    9V DC
    12V DC
    24V DC
    15V DC11212 amp @ 30V DC303.9"1.4"3.1"DataModbus TCP/IPAndroid 6.0 or Later, iOS 9.0 or Later, Windows XP or LaterLED Indicators7059N110000000
    86V DC
    9V DC
    12V DC
    24V DC
    15V DC11212 amp @ 30V DC303.9"1.4"3.1"DataPoE Type 1Modbus TCP/IPAndroid 6.0 or Later, iOS 9.0 or Later, Windows XP or LaterLED Indicators7059N12000000
     

    Relay Sockets

    Image of Product. Front orientation. Contains Annotated. Relay Sockets. Style E.

    Style E

    Mount to 35 mm DIN rail (also known as DIN 3 rail) or flat surfaces, then plug your relay into these sockets for fast installation.
    Recessed Terminals—Recessed terminals prevent contact with live connections.
    Hold-Down Clips—Hold-down clips (sold separately) secure the socket in applications subject to vibration.
    Sockets
    Hold-Down Clips
    Style
    No. of
    Terminals
    For Quick-Disconnect
    Tab Wd.
    For Switching Current
    @ Voltage
    For Max. Switching
    Voltage, V AC
    Ht.
    Wd.
    Dp.
    Features
    Each
    Pkg.
    Qty.
    Pkg.
    Quick-Disconnect-Terminal Relay Connection
     
    Screw-Terminal Wire Connection
    E140.2"12 amp @ 240V AC2403.1"1.8"1.3"Recessed Terminals7122K2400000027122K6900000
     

    Safety Relays

    Receive signals from safety monitoring relays or controllers to switch devices off and on because of a system failure. Also known as force-guided or mechanically linked contacts, the interlocking opposing contacts on these relays cannot be open or closed at the same time. To keep your system from receiving false switching signals, the interlocking opposing contact must remain open even if a contact welds closed.
    IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits. These relays have been tested to safety standards that can help you achieve your system's PL (performance level) and SIL (safety integrity level). Choose a relay with a PL and SIL rating to meet the needs of your system. Higher ratings indicate greater safety protection. As your system becomes more complex, you generally require a higher safety protection level. Mount them to 35mm DIN rail (also known as DIN 3 Rail).
    SIL 3, PLe, CAT IV, 600V Max. System Safety Rating—DIN-Rail and Surface Mount
    Image of Product. Front orientation. Contains Annotated. Safety Relays. Safety Relays, SIL 3, PLe, CAT IV, 600V Max. System Safety Rating—DIN-Rail and Surface Mount.
    Relays that meet SIL 3 are tested for applications with a probability of failure of 0.01% to 0.1% and are used for preventing fires, explosions, or toxic releases.
    Relays that meet CAT 4 withstand circuit surges in electrical applications up to 600V.
    Mirror Auxiliary Contacts—Relays with mirror auxiliary contacts have contacts that are normally closed and cannot be open at the same time as a normally open main contact.
    Nondetachable Auxiliary Contacts—Relays with nondetachable contacts have auxiliary contacts that won’t separate from the relay if there is shock or vibration.
    Self-Monitoring Circuitry—When a failure is detected, relays with self-monitoring circuitry signal the controller to remove power and prevent restarting until the issue is resolved.
    hp @
    Switching Voltage
    No. of
    Terminals
    Input
    Voltage
    Control Current,
    mA
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V AC
    Single Phase
    Three Phase
    Aux. Contact Switch
    Starting Position
    Ht.
    Wd.
    Dp.
    Features
    Each
    Screw-Terminal Wire Connection
     
    3 Circuits Controlled with 3 Off—3PST-NO
    18120V AC212 amp @ 400V AC6001 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC
    10 hp @ 480V AC
    10 hp @ 600V AC
    2 Off and 3 On2.7"1.8"4.6"Inspection Window, Interlocked Opposing Contacts, Mirror Auxiliary Contacts, Nondetachable Auxiliary Contacts, Recessed Terminals, Self-Monitoring Circuitry6242N130000000
    1824V DC1812 amp @ 400V AC6001 hp @ 120V AC
    2 hp @ 240V AC
    3 hp @ 240V AC
    10 hp @ 480V AC
    10 hp @ 600V AC
    2 Off and 3 On2.7"1.8"4.6"Inspection Window, Interlocked Opposing Contacts, Mirror Auxiliary Contacts, Nondetachable Auxiliary Contacts, Recessed Terminals, Self-Monitoring Circuitry6242N17000000
     
    back to top