About Selecting Temperature Sensors
More
Threaded RTD Probe Transmitters for Liquids and Gases
Send temperature readings directly to programmable logic controllers (PLCs)—with a built-in transmitter, these RTDs don’t require a separate signal converter. They’re threaded, so they’re ready to install into containers, tanks, and pipes. These RTDs are made of 316 or 316L stainless steel, so they’re highly corrosion resistant. All are CE Marked as meeting European safety standards.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/646/6467t21-1581972534-p9@halfx_637175477542608964.png?ver=imagenotfound)
Probe | Probe Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Lg. | Dia. | Accuracy | Pipe Size | Thread Type | Gender | DC Voltage | Max. Pressure, psi | Output Current | Overall Lg. | Choose a Temperature Range | Each | |
316 Stainless Steel Probe with Plastic Head (IP65) | |||||||||||||
100 ohms | 2 1/2" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 5 3/4" | 000000 | 0000000 | |
100 ohms | 4" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 7 1/4" | 000000 | 000000 | |
100 ohms | 6" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 9 1/4" | 000000 | 000000 | |
100 ohms | 9" | 1/4" | ±0.5% | 1/2 | NPT | Male | 10-30 | 725 | 4-20mA | 12 1/4" | 000000 | 000000 |
Threaded RTD Probe Transmitters for Air
![](/prerenderstable/mvPRE/contents/gfx/imagecache/407/40705k35-1582032284-p9@halfx_637176074922009342.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/407/40705k81multipositive_top_positive_front_hex_1588686655_719@halfx_637242658931756579.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/407/40705k71multinegative_right_positive_front_standard15_1588686601_715@halfx_637242654373076019.png?ver=imagenotfound)
A built-in transmitter converts the probe’s air-temperature readings to a 4-20 mA signal for use with switches, controllers, and data loggers. Consider the temperature of your application when selecting a probe. Choose a temperature range that closely matches your application to save time configuring the probe. For more flexibility, choose a probe with a large range. You can reconfigure probes for multiple applications.
Replacement elements include a ¼” probe, spring, and 3” of leads.
For technical drawings and 3-D models, click on a part number.
Probes | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Probe | Probe Connection | Conduit Connection | Replacement Elements | ||||||||||||||||
RTD Type | Lg. | Dia. | Accuracy | Response Time, sec. | Connection Type | Head Material | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | DC Voltage | Overall Lg. | Choose a Temperature Range | Each | Each | ||
316 Stainless Steel Probe | |||||||||||||||||||
100 ohms | 4" | 1/4" | ±0.1% | 6 | Screw Terminal | Aluminum | 1/2 | NPT | Male | 3/4 | NPT | Female | 10, 30 | 9" | 0000000 | 0000000 | 00000000 | 0000000 | |
100 ohms | 6" | 1/4" | ±0.1% | 6 | Screw Terminal | Aluminum | 1/2 | NPT | Male | 3/4 | NPT | Female | 10, 30 | 11" | 0000000 | 000000 | 00000000 | 000000 | |
100 ohms | 9" | 1/4" | ±0.1% | 6 | Screw Terminal | Aluminum | 1/2 | NPT | Male | 3/4 | NPT | Female | 10, 30 | 14" | 0000000 | 000000 | 00000000 | 000000 | |
100 ohms | 12" | 1/4" | ±0.1% | 6 | Screw Terminal | Aluminum | 1/2 | NPT | Male | 3/4 | NPT | Female | 10, 30 | 17" | 0000000 | 000000 | 00000000 | 000000 |
Replacement Transmitter for Probes with 0° to 100° F Temperature Range | 00000000 | Each | 0000000 |
Replacement Transmitter for Probes with 0° to 200° F Temperature Range | 00000000 | Each | 000000 |
Replacement Transmitter for Probes with 0° to 400° F Temperature Range | 00000000 | Each | 000000 |
Replacement Transmitter for Probes with 0° to 300° F Temperature Range | 00000000 | Each | 000000 |
Sanitary RTD Probe Transmitters with Digital Display
Check the temperature of liquids in hygienic applications such as food or pharmaceutical lines and tanks. Certified by 3-A to meet sanitary design standards, the parts of these probes that will touch liquid are highly polished to minimize spots where bacteria could grow. They're rated IP67 and IP69K, so they'll withstand temporary submersion as well as the high-pressure, high-temperature washdowns that are common in hygienic cleaning practices. Made of stainless steel, harsh cleaners and sanitizers won't cause them to corrode. They have a flange that will connect to sanitary quick-clamp fittings (also known as tri-clamp fittings); they're easy to connect and remove from your line.
Program these probes with the touch screen, and select one of three colors as a visual alert for events in your process such as irregular or fluctuating temperatures. The head swivels 345° and the face rotates all the way around, so you can mount the sensor at any angle and still see the display. To trigger actions in your process line, connect these probes to remote displays, programmable logic controllers (PLCs), and other control equipment with the M12 plug. These probes meet DIN EN 60751, an industry standard for accuracy. They’re also CE marked, meaning they meet European Union safety standards.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/690/6904n12-1586796820-p9@halfx_637223757464034745.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/690/6904np1-display-rgb@halfx_637223761179140172.png?ver=imagenotfound)
Probe | Probe Transmitters | Cables with Socket | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Flange OD | Accuracy | Response Time, sec. | Plug Type | DC Voltage | Max. Pressure, psi | Output Current | Overall Lg. | Each | Each | ||
316L Stainless Steel Probe with 304 Stainless Steel Head (IP67, IP69K) | |||||||||||||||
For 1 1/2" Tube OD | |||||||||||||||
100 ohms | -55° to 480° | 2" | 5/16" | 1.988" | ±0.1% | 25 | 5-Pole Micro M12 | 8-35 | 580 | 4-20mA | 6 3/4" | 0000000 | 0000000 | 0000000 | 000000 |
Threaded RTD Probes with Thermowell for Liquids and Gases
![](/prerenderstable/mvPRE/contents/gfx/imagecache/658/6581t51-1582043681-p9@halfx_637176189178464488.png?ver=imagenotfound)
To protect the probe from vibration, corrosion, and shock, these RTD probes come with a thermowell.
Probe | Thermowell Connection | Conduit Connection | Material | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, ° F | Lg. | Dia. | Accuracy | Response Time, sec. | Connection Type | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Overall Lg. | Head | Probe | Each | |
304 Stainless Steel Thermowell | |||||||||||||||||
100 ohms | -55° to 400° | 5 1/2" | 1/2" | ±0.12% | 30 | Screw Terminal | 3/4 | NPT | Male | 3/4 | NPT | Female | 14 1/8" | Cast Iron | 304 Stainless Steel | 0000000 | 0000000 |
100 ohms | -55° to 400° | 8 1/2" | 1/2" | ±0.12% | 30 | Screw Terminal | 3/4 | NPT | Male | 3/4 | NPT | Female | 17 1/8" | Cast Iron | 304 Stainless Steel | 0000000 | 000000 |
100 ohms | -55° to 400° | 11 1/2" | 1/2" | ±0.12% | 30 | Screw Terminal | 3/4 | NPT | Male | 3/4 | NPT | Female | 20 1/8" | Cast Iron | 304 Stainless Steel | 0000000 | 000000 |
RTD Probes with Armored Cable for Liquids and Gases
![](/prerenderstable/mvPRE/contents/gfx/imagecache/122/1220n11p1-c02a-digital@halfx_637055483752753828.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/122/1220n12-@halfx_637526251160180704.png?ver=imagenotfound)
For long service life in harsh conditions, these RTD probes have an armored stainless steel cable to protect wiring from corrosion, abrasion, and impact.
Probes with strain relief offer extra support for moving cables. They also help avoid kinking for longer cable life.
Probe | Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range , ° F | Lg. | Dia. | Accuracy | Response Time, sec. | Cable Lg., ft. | Connection Type | Cable Material | Max. Cable Temperature, ° F | Lead Lg. | Gauge | No. of Wires | Each | |
304 Stainless Steel Probe | ||||||||||||||
Probe | ||||||||||||||
100 ohms | -55° to 400° | 6" | 1/4" | ±0.12% | 3.5 | 6 | Wire Leads | Stainless Steel Armor | 400° | 6ft. | 24 | 3 | 0000000 | 0000000 |
100 ohms | -55° to 400° | 6" | 1/4" | ±0.12% | 10 | 3 | Wire Leads | Stainless Steel Armor | 400° | 36" | 24 | 3 | 0000000 | 000000 |
100 ohms | -55° to 400° | 12" | 1/4" | ±0.12% | 10 | 10 | Wire Leads | Stainless Steel Armor | 400° | 10ft. | 24 | 3 | 0000000 | 000000 |
Probe with Strain Relief | ||||||||||||||
100 ohms | -55° to 400° | 3" | 1/4" | ±0.12% | 10 | 10 | Wire Leads | Braided Stainless Steel Armor | 400° | 10ft. | 24 | 3 | 0000000 | 00000 |
100 ohms | -55° to 400° | 6" | 1/4" | ±0.12% | 10 | 10 | Wire Leads | Braided Stainless Steel Armor | 400° | 10ft. | 24 | 3 | 0000000 | 00000 |
100 ohms | -55° to 400° | 12" | 1/4" | ±0.12% | 10 | 10 | Wire Leads | Braided Stainless Steel Armor | 400° | 10ft. | 24 | 3 | 0000000 | 00000 |
Cut-to-Length RTD Probes for Liquids and Gases
![](/prerenderstable/mvPRE/contents/gfx/imagecache/387/38705k44c1-c02a-digital-master1569965746-p9@halfx_637055490564521563.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/387/38705k118-1592326932-p9@halfx_637279057353313210.png?ver=imagenotfound)
Use a pipe cutter to trim these probes for an exact fit.
Probes with six wires are dual probes. Use them to control two output devices or to get an average temperature reading across two different areas.
Probe | Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, ° F | Lg. | Dia. | Cuttable Lg. | Accuracy | Response Time, sec. | Connection Type | Sensing Tip Lg. | Sensing Element Material | Lead Lg. | Gauge | No. of Wires | Each | |
304 Stainless Steel Probe | ||||||||||||||
100 ohms | -55° to 400° | 12" | 3/16" | 8 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 0000000 |
100 ohms | -55° to 400° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 000000 |
100 ohms | -55° to 400° | 24" | 3/16" | 20 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 400° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 000000 |
100 ohms | -55° to 400° | 48" | 1/4" | 44 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 400° | 72" | 1/4" | 68 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 96" | 1/4" | 92 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 3/16" | 8 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 000000 |
100 ohms | -55° to 900° | 24" | 3/16" | 20 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 900° | 48" | 1/4" | 44 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
RTD Probes for Air
![](/prerenderstable/mvPRE/contents/gfx/imagecache/123/1237n11p1-c02a-digital@halfx_637055491909772050.png?ver=imagenotfound)
Use these RTD probes for more stable air-temperature readings than thermocouple probes.
Probe | Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, ° F | Lg. | Dia. | Accuracy | Response Time, sec. | Cable Lg., ft. | Connection Type | Max. Cable Temperature, ° F | Lead Lg. | Gauge | Each | |
Platinum Probe | ||||||||||||
PTFE Cable | ||||||||||||
100 ohms | -55° to 400° | 5/8" | 1/8" | ±0.12% | 5 | 3 | Wire Leads | 400° | 1/2" | 24 | 0000000 | 000000 |
100 ohms | -55° to 400° | 5/8" | 1/8" | ±0.12% | 5 | 6 | Wire Leads | 400° | 1/2" | 24 | 0000000 | 00000 |
Fiberglass Cable | ||||||||||||
100 ohms | -55° to 900° | 5/8" | 1/8" | ±0.12% | 5 | 3 | Wire Leads | 900° | 1/2" | 24 | 0000000 | 00000 |
100 ohms | -55° to 900° | 5/8" | 1/8" | ±0.12% | 5 | 6 | Wire Leads | 900° | 1/2" | 24 | 0000000 | 00000 |
100 ohms | -55° to 900° | 5/8" | 1/8" | ±0.12% | 5 | 10 | Wire Leads | 900° | 1/2" | 24 | 0000000 | 00000 |
100 ohms | -55° to 900° | 5/8" | 1/8" | ±0.12% | 5 | 25 | Wire Leads | 900° | 1/2" | 24 | 0000000 | 00000 |
Sanitary RTD Probes
Designed for clean-in-place applications such as dairy processing and food-preparation areas, these 3-A certified RTDs have a sanitary quick-clamp connection for easy removal.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/385/3858k12c1-c02a-digital-master1569965743-p9@halfx_637055457235469354.png?ver=imagenotfound)
Probe | Conduit Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Flange OD | Accuracy | Response Time, sec. | Connection Type | Pipe Size | Thread Type | Gender | Overall Lg. | Each | |
316 Stainless Steel Probe with Plastic Head | |||||||||||||
For 1 1/2" Tube OD | |||||||||||||
100 ohms | -325° to 400° | 4" | 1/4" | 1.984" | ±0.1% | 5 | Screw Terminal | 3/4 | NPT | Female | 11" | 0000000 | 0000000 |
For 2" Tube OD | |||||||||||||
100 ohms | -325° to 400° | 4" | 1/4" | 2.516" | ±0.1% | 5 | Screw Terminal | 3/4 | NPT | Female | 11" | 0000000 | 000000 |
RTD Transmitters
Send temperature readings from RTD probes in containers, tanks, and pipes to switches and programmable logic controllers (PLCs).
Transmitters with IO Link let you change settings, read measurements, and receive error messages remotely when connected to a PLC via an IO Link controller (not included).
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/385/38535k43p1-c02a-digital@halfx_637055513355131416.png?ver=imagenotfound)
For Panel Cutout | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For RTD Probe Type | Temperature Range, °C | DIN Trade Size | Ht. | Wd. | Ht. | Wd. | Dp. | AC Voltage (Phase) | Output Current | Housing Material | Display | Resolution | For Max. Wire Gauge | Each | |
Screw Terminal Connection Type | |||||||||||||||
100 ohms | -50° to 850° | 1/8 | 1 3/4" | 3 5/8" | 1 7/8" | 3 7/8" | 6 1/16" | 120, 240 (Single) | 4-20mA | Aluminum | LCD | 1 | 26 | 00000000 | 0000000 |
![](/prerenderstable/mvPRE/contents/gfx/imagecache/388/38875k77p1-c02a-digital@halfx_637055567614046992.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/388/38875k91multinegative_right_positive_front_flop15_1635336904_913@halfx_637709157861685826.png?ver=imagenotfound)
with Micro
M12 Connection
For RTD Probe Type | Temperature Range, °F | Dia. | Dp. | DC Voltage | Output Current | Output Voltage | Communication Protocol | Housing Material | For Max. Wire Gauge | Environmental Rating | Each | |
Screw Terminal Connection Type | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
100 ohms | 0° to 250° | 1 11/16" | 13/16" | 12-36 | 4-20mA | __ | __ | Plastic | 26 | __ | 00000000 | 000000 |
100 ohms | 0° to 500° | 1 11/16" | 13/16" | 12-36 | 4-20mA | __ | __ | Plastic | 26 | __ | 00000000 | 00000 |
4-Pole Micro M12 Connection Type | ||||||||||||
100 ohms/1,000 ohms | -55° to 300° | 3/4" | 2" | 20-32 | 4-20mA | __ | IO Link | Plastic | __ | IP67 | 00000000 | 000000 |
100 ohms/1,000 ohms | 32° to 212° | 3/4" | 2" | 20-32 | 4-20mA | __ | IO Link | Plastic | __ | IP67 | 00000000 | 000000 |
100 ohms/1,000 ohms | 32° to 212° | 3/4" | 2" | 18-32 | __ | 0-10V DC | IO Link | Plastic | __ | IP67 | 00000000 | 000000 |
High-Temperature Panel-Mount Thermometers
![](/prerenderstable/mvPRE/contents/gfx/imagecache/406/4068k73p1-c02a-digital@halfx_637055522016427025.png?ver=imagenotfound)
Often used to remotely monitor probe readings in high-temperature applications, these thermometers have a housing designed for installation in instrument and control panels. They interpret data from a thermocouple probe or RTD probe (sold separately).
For technical drawings and 3-D models, click on a part number.
For Panel Cutout | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | For RTD Probe Type | DIN Trade Size | Ht. | Wd. | Ht. | Wd. | Dp. | Electrical Connection | Frequency, Hz | Each | |
-58° to 200° F/-50° to 199° C | 0.1 | ±0.3° F | 100 ohms | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 0000000 |
-58° to 1,562° F/-50° to 850° C | 1 | ±2.0° F | 100 ohms | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
Quick-Response Food and Beverage Panel-Mount Thermometers
![](/prerenderstable/mvPRE/contents/gfx/imagecache/386/38675k343_1f1e40c4-9918-4891-968b-0816b333672a@halfx_1676664919.png?ver=imagenotfound)
A resistance temperature detector (RTD) probe responds to temperature change faster than dial thermometers.
For technical drawings and 3-D models, click on a part number.
Probe | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | For RTD Probe Type | Cable Lg., ft. | Dia. | Lg. | Panel Cutout Dia. | AC Voltage | Electrical Connection | Response Time, sec. | Includes | Each | |
-40° to 250° F | 1 | ±2° F | 1,000 ohms | 8 | 1/4" | 2 5/8" | 2 3/32" | 120 | Plug | 1 | Bracket Assembly | 000000000 | 0000000 |
-40° to 120° C | 1 | ±2° C | 1,000 ohms | 8 | 1/4" | 2 5/8" | 2 3/32" | 120 | Plug | 1 | Bracket Assembly | 000000000 | 000000 |
Extended-Life Hand-Held Thermometers with Calibration Certificate
![](/prerenderstable/mvPRE/contents/gfx/imagecache/928/9282t22-@halfx_637401011508998721.png?ver=imagenotfound)
For a longer service life than thermocouple probes and more consistent readings over time, these thermometers have a resistance temperature detector (RTD) probe. They come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy.
Probe | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Specifications Met | Batteries Included | Each | |
For Use With Air, Gases, Liquids | |||||||||||
-148° to 572° F/-100° to 300° C | 0.01/0.01 | ±0.9° F/±0.5° C | 1 | 1 | 3 | 6" | 1/8" | CE Marked | Yes | 0000000 | 0000000 |
Extended-Life Data-Logging Thermometers
![](/prerenderstable/mvPRE/contents/gfx/imagecache/386/38655k18p1-c02a-digital@halfx_637055517220890663.png?ver=imagenotfound)
For more accurate and consistent readings than thermometers with thermocouple probes and a longer service life, this thermometer has a resistance temperature detector (RTD) probe. It logs up to 2,000 time- and date-stamped readings and uploads data to a PC through the USB port.
To conserve battery life, use the optional power adapter (sold separately).
Probe | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Length, ft. | Lg. | Dia. | Specifications Met | Batteries Included | Each | |
For Use With Air, Gases, Liquids, Solids, Surfaces | |||||||||||
-58° to 932° F/-50° to 500° C | 0.1/0.1 | ±0.1° F/±0.1° C | 1 | 10 | 5 | 4" | 3/16" | CE Marked | Yes | 00000000 | 000000000 |
Terminal Blocks for RTD Wire
![](/prerenderstable/mvPRE/contents/gfx/imagecache/387/38705k83p1-c02a-digital@halfx_637055569270925600.png?ver=imagenotfound)
Connect RTD wire leads to conduit or instrumentation.
For Max. Wire Gauge | Wire Connection Type | Each | |
14 | Screw Terminals | 00000000 | 000000 |