    57 Products
    About Proximity Sensors
    industrial info icon

    Compare sensing types, mounting styles, wiring options, and input and output requirements to choose the right proximity sensor for your application.

    DC Metallic-Object Proximity Sensors for Long Distances

    Image of Product. Projecting with Wire Leads. Front orientation. Projecting Mount. DC Metallic-Object Proximity Sensors for Long Distances, Hardwire.

    Projecting with

    Wire Leads

    Image of Product. Projecting with Plug. Front orientation. Projecting Mount. DC Metallic-Object Proximity Sensors for Long Distances, Plug In.

    Projecting with

    Plug

    Image of Specification. 4-Pole M12 Plug. Front orientation. Plug In. DC Metallic-Object Proximity Sensors for Long Distances, M12 Connection, 4 Poles.

    4-Pole

    M12

    Plug

    Sense objects from farther away than with other proximity sensors that have the same diameter. Also known as inductive proximity sensors, they remotely sense metallic objects even if they’re obscured by water, oil, dirt, or a surface finish. Sensing distance is based on the type of material being sensed. The distance listed is for mild steel. They’re often used with programmable logic controllers (PLCs) and produce PNP signal output. Some automatically sense whether PNP or NPN signal output is needed.
    Also available: If you don’t see the sensor you need, please select 1429T999 and specify manufacturer and manufacturer part number.
    Flush Mount—Flush sensors, also known as embeddable or shielded sensors, can be mounted so that the sensor face is level with the surface of any material, including metal. They’re more accurate than projecting sensors at close range and can be mounted close together without causing interference.
    Projecting Mount—Projecting sensors, also known as non-embeddable or unshielded sensors, must be mounted with the area around the sensor face free of metal. They have a longer sensing distance than flush sensors with the same diameter.
    Plug In—Sensors with a 4-pole M12 plug connect to cables with a socket (sold separately), allowing you to quickly connect and disconnect the sensor.
    Enclosure Rating—All sensors are rated IP69K for protection from high-temperature, high-pressure washdowns. Some are also rated NEMA 6P, 13, and IP67 for protection from corrosion, oil/coolant spraying, and temporary submersion.
    Sensors
    Cables with
    Sockets
    Switch Starting
    Position
    Max. Sensing
    Distance, mm
    Dia.,
    mm
    Output Digital
    Signal
    Input Voltage
    Electrical
    Connection Type
    No. of Wire
    Leads
    Lg.,
    mm
    Cable Lead
    Lg., ft.
    Temp. Range,
    ° F
    Enclosure Rating
    Each
    Each
    Stainless Steel Housing with Plastic Face
     
    Flush with Wire Lead Connection
    1 Off
    818PNP/NPN6V DC to 48V DCHardwire3666 1/2-40 to 155IP67, IP69K, NEMA 6P, NEMA 13
    1429T160000000———0
    1 Off
    1530PNP/NPN6V DC to 48V DCHardwire3716 1/2-40 to 155IP67, IP69K, NEMA 6P, NEMA 13
    1429T21000000———0
     
    Flush with 4-Pole M12 Connection
    1 Off
    412PNP/NPN6V DC to 48V DCPlug In77-40 to 155IP67, IP69K, NEMA 6P, NEMA 13
    1429T110000006897K36000000
    1 Off
    818PNP/NPN6V DC to 48V DCPlug In69-40 to 155IP67, IP69K, NEMA 6P, NEMA 13
    1429T150000006897K3600000
    1 Off
    1530PNP/NPN6V DC to 48V DCPlug In74-40 to 155IP67, IP69K, NEMA 6P, NEMA 13
    1429T190000006897K3600000
     
    Projecting with Wire Lead Connection
    1 Off
    1012PNP/NPN6V DC to 48V DCHardwire3736 1/2-40 to 155IP67, IP69K, NEMA 6P, NEMA 13
    1429T14000000———0
    1 Off
    1618PNP/NPN6V DC to 48V DCHardwire3666 1/2-40 to 155IP67, IP69K, NEMA 6P, NEMA 13
    1429T18000000———0
    1 Off
    2930PNP/NPN6V DC to 48V DCHardwire3716 1/2-40 to 155IP67, IP69K, NEMA 6P, NEMA 13
    1429T23000000———0
     
    Projecting with 4-Pole M12 Connection
    1 Off
    1012PNP/NPN6V DC to 48V DCPlug In77-40 to 155IP67, IP69K, NEMA 6P, NEMA 13
    1429T130000006897K3600000
    1 Off
    1618PNP/NPN6V DC to 48V DCPlug In69-40 to 155IP67, IP69K, NEMA 6P, NEMA 13
    1429T170000006897K3600000
    1 Off
    2930PNP/NPN6V DC to 48V DCPlug In74-40 to 155IP67, IP69K, NEMA 6P, NEMA 13
    1429T220000006897K3600000
     
    Projecting with 4-Pole M12 Connection, Computer Cord, and Software
    1 Off
    1012PNP/NPN6V DC to 48V DCPlug In77-40 to 155IP67, IP69K, NEMA 6P, NEMA 13
    1429T520000006897K3600000
     

    AC Metallic-Object Proximity Sensors for Long Distances

    Image of Product. Flush with Wire Leads. Front orientation. Stainless Steel Housing. AC Metallic-Object Proximity Sensors for Long Distances, Flush Mount, Hardwire.
    Image of Product. Flush with Plug. Front orientation. Stainless Steel Housing. AC Metallic-Object Proximity Sensors for Long Distances, Flush Mount, Plug In.

    Flush with Wire

    Leads

    Flush with Plug

    Image of Product. Projecting with Wire Leads. Front orientation. Stainless Steel Housing. AC Metallic-Object Proximity Sensors for Long Distances, Projecting Mount, Hardwire.
    Image of Product. Projecting with Plug. Front orientation. Stainless Steel Housing. AC Metallic-Object Proximity Sensors for Long Distances, Projecting Mount, Plug In.

    Projecting with

    Wire Leads

    Projecting with

    Plug

    Image of Specification. 3-Pole M12 Plug. Front orientation. 1 Off Switch Starting Position. AC Metallic-Object Proximity Sensors for Long Distances, Plug In.

    3-Pole

    M12

    Plug

    Sense objects from farther away than with other proximity sensors that have the same diameter. Also known as inductive proximity sensors, they remotely sense metallic objects even if they’re obscured by water, oil, dirt, or a surface finish. Sensing distance is based on the type of material being sensed. The distance listed is for mild steel. All are rated NEMA 6P, 13, IP67 and IP69K.
    Also available: If you don’t see the sensor you need, please select 1429T999 and specify manufacturer and manufacturer part number.
    Flush Mount—Flush sensors, also known as embeddable or shielded sensors, can be mounted so that the sensor face is level with the surface of any material, including metal. They’re more accurate than projecting sensors at close range and can be mounted close together without causing interference.
    Projecting Mount—Projecting sensors, also known as non-embeddable or unshielded sensors, must be mounted with the area around the sensor face free of metal. They have a longer sensing distance than flush sensors with the same diameter.
    Plug In—Sensors with a 3-pole M8 plug connect to cables with a socket (sold separately), allowing you to quickly connect and disconnect the sensor.
    Sensors
    Cables with
    Sockets
    Switch Starting
    Position
    Dia.,
    mm
    Max. Sensing
    Distance, mm
    Input Voltage
    Current
    Output
    Electrical
    Connection Type
    No. of Wire
    Leads
    Lg.,
    mm
    Cable Lead
    Lg., ft.
    Cable
    OD
    Temp. Range,
    ° F
    Certification
    Each
    Each
    Stainless Steel Housing with Plastic Face (IP67, IP69K, NEMA 6P, NEMA 13)
     
    Flush with Wire Lead Connection
    1 Off
    12420V AC to 132V AC200 mAHardwire2736 1/20.19"-40 to 155C-UL Listed, CE Marked, UL Listed
    1429T820000000———0
    1 Off
    18820V AC to 132V AC200 mAHardwire2666 1/20.22"-40 to 155C-UL Listed, CE Marked, UL Listed
    1429T42000000———0
    1 Off
    301520V AC to 132V AC200 mAHardwire2716 1/20.22"-40 to 155C-UL Listed, CE Marked, UL Listed
    1429T46000000———0
     
    Flush with 3-Pole M12 Connection
    1 Off
    12420V AC to 132V AC200 mAPlug In77-40 to 155C-UL Listed, CE Marked, UL Listed
    1429T81000000———0
    1 Off
    18820V AC to 132V AC200 mAPlug In69-40 to 155C-UL Listed, CE Marked, UL Listed
    1429T410000006897K86000000
    1 Off
    301520V AC to 132V AC200 mAPlug In74-40 to 155C-UL Listed, CE Marked, UL Listed
    1429T450000006897K8600000
     
    Projecting with Wire Lead Connection
    1 Off
    121020V AC to 132V AC200 mAHardwire2736 1/20.19"-40 to 155C-UL Listed, CE Marked, UL Listed
    1429T84000000———0
    1 Off
    181820V AC to 132V AC200 mAHardwire2666 1/20.22"-40 to 155C-UL Listed, CE Marked, UL Listed
    1429T44000000———0
    1 Off
    302920V AC to 132V AC200 mAHardwire2716 1/20.22"-40 to 155C-UL Listed, CE Marked, UL Listed
    1429T48000000———0
     
    Projecting with 3-Pole M12 Plug Connection
    1 Off
    121020V AC to 132V AC200 mAPlug In77-40 to 155C-UL Listed, CE Marked, UL Listed
    1429T830000006897K8600000
    1 Off
    181820V AC to 132V AC200 mAPlug In69-40 to 155C-UL Listed, CE Marked, UL Listed
    1429T430000006897K8600000
    1 Off
    302920V AC to 132V AC200 mAPlug In74-40 to 155C-UL Listed, CE Marked, UL Listed
    1429T470000006897K8600000
     

    Light Beam Finger-Touch Switches

    Image of Product. Front orientation. Finger-Touch Switches. Light Beam Finger-Touch Switches.
    An infrared light beam senses the lightest finger contact to switch a circuit on or off. The included guard prevents accidental activation. An indicator lights up to confirm that switches are actuated. They’re rated NEMA 4X, 13, and IP66 for protection from corrosion, washdowns, and oil/coolant spraying.
    M22 Connection—Switches with a 5-pole M22 connection can quickly be changed out.
    Wire
    Leads
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Switch
    Designation
    Actuator
    Color
    Switching Current
    @ Voltage
    Current
    Output, mA
    Input Voltage
    Dp. Behind
    Panel
    No.
    of
    Ga.
    Features
    Each
    Plastic Actuator with Wire Lead Connection
     
    For 30 mm (1 3/16") Diameter Panel Cutouts
    11 Off or 1 On
    Momentary
    SPDT
    Black7 amp @ 120V AC120V AC3/4"522
    Guard
    Output Indicator
    Power Indicator
    72025K910000000
    11 Off or 1 On
    Momentary
    SPDT
    Black7 amp @ 120V AC20V AC to 30V AC/20V DC to 30V DC3/4"522
    Guard
    Output Indicator
    Power Indicator
    72025K93000000
     
    Plastic Actuator with Wire Lead Connection and NPN Output Signal
     
    For 30 mm (1 3/16") Diameter Panel Cutouts
    Momentary
    Black15010V DC to 30V DC3/4"422
    Guard
    Output Indicator
    Power Indicator
    72025K94000000
     
    Plastic Actuator with 5-Pole M22 Connection
     
    For 30 mm (1 3/16") Diameter Panel Cutouts
    11 Off or 1 On
    Momentary
    SPDT
    Black7 amp @ 120V AC120V AC1 3/8"Guard
    Output Indicator
    Power Indicator
    72025K92000000
    11 Off or 1 On
    Momentary
    SPDT
    Black7 amp @ 120V AC20V AC to 30V AC/20V DC to 30V DC1 3/8"Guard
    Output Indicator
    Power Indicator
    72025K11000000
     
    Accessories and Replacements for Finger-Touch Switches

    Space-Saving Photoelectric Sensors

    With a narrow, flat body, these sensors fit in tight spaces. They detect the presence or absence of an object moving at high speeds with a light beam. Adjust the intensity of the light beam to better detect shiny or translucent objects. All are rated NEMA 4X, 13, and IP67 for protection from corrosion, oil/coolant spraying, washdowns, and temporary submersion.
    With Wire Leads
    Image of Product. Front orientation. Photoelectric Sensors. Space-Saving Photoelectric Sensors , Wire Lead Connection.
    Direct Sensing—Direct sensing sensors detect objects when light reflects back from the object. The transmitter and receiver are in the same housing, so they fit in confined spaces.
    Receiver Sensor—Receiver sensors detect objects when an object breaks the light beam between the transmitter and receiver (both included). They have a longer sensing distance than direct-sensing and reflector sensors.
    Reflector Sensor—Reflector sensors detect an object when it passes between the sensor and the reflector, interrupting the beam. They have a longer sensing distance than direct-sensing sensors.
    10V DC to 30V DC Input Voltage—Sensors with DC input voltage automatically produce either PNP or NPN signal output, based on the device they are connected to.
    Light Beam Switch Operation
    Max. Sensing
    Distance
    Input Voltage
    Current
    Output, mA
    Output Digital
    Signal
    Lg.
    Ht.
    Wd.
    Dia.,
    mm
    Includes
    Cable Lead
    Lg., ft.
    Housing
    Material
    Mounting Thread
    Size
    Reflector
    Dia.
    Temp. Range,
    ° F
    Performance
    Environment
    Certification
    Each
    Adjustable Direct Sensing Sensor with Infrared LED Light Beam (IP67, NEMA 4X, NEMA 13)
    On When Object Absent, On When Object Present15"24V AC to 240V AC1002 5/8"1 3/16"1/2"186 1/2PlasticM18 × 1 mm0 to 155Space SavingCorrosive
    Washdown
    Submersible
    Dusty
    Oily
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    CSA Certified
    9539T10000000
    On When Object Absent, On When Object Present15"10V DC to 30V DC100PNP/NPN2 1/8"1 3/16"1/2"186 1/2PlasticM18 × 1 mm0 to 155Space SavingCorrosive
    Washdown
    Submersible
    Dusty
    Oily
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    CSA Certified
    9539T7000000
     
    Adjustable Receiver Sensor with Infrared LED Light Beam (IP67, NEMA 4X, NEMA 13)
    On When Object Absent, On When Object Present100 ft.24V AC to 240V AC1002 5/8"1 3/16"1/2"186 1/2PlasticM18 × 1 mm0 to 155Space SavingCorrosive
    Washdown
    Submersible
    Dusty
    Oily
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    CSA Certified
    9539T3000000
    On When Object Absent, On When Object Present100 ft.10V DC to 30V DC100PNP/NPN2 1/8"1 3/16"1/2"186 1/2PlasticM18 × 1 mm0 to 155Space SavingCorrosive
    Washdown
    Submersible
    Dusty
    Oily
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    CSA Certified
    9539T9000000
     
    Adjustable Reflector Sensor with Visible LED Light Beam (IP67, NEMA 4X, NEMA 13)
    On When Object Absent, On When Object Present10 ft.24V AC to 240V AC1002 5/8"1 3/16"1/2"18Reflector6 1/2PlasticM18 × 1 mm3 5/16"0 to 155Space SavingCorrosive
    Washdown
    Submersible
    Dusty
    Oily
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    CSA Certified
    9539T2000000
    On When Object Absent, On When Object Present10 ft.10V DC to 30V DC100PNP/NPN2 1/8"1 3/16"1/2"18Reflector6 1/2PlasticM18 × 1 mm3 5/16"0 to 155Space SavingCorrosive
    Washdown
    Submersible
    Dusty
    Oily
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    CSA Certified
    9539T8000000
     
    With 3-Pole 1/2"-20 UNF Plug
    Image of Product. Front orientation. Photoelectric Sensors. Space-Saving Photoelectric Sensors , Plug In.
    Image of Specification. 3-Pole Plug. Front orientation. 1/2" Circular Connection. Space-Saving Photoelectric Sensors .

    3-Pole

    Plug

    Sensors with a plug connect to cables with a socket (sold separately), allowing you to quickly connect and disconnect the sensor.
    Direct Sensing—Direct sensing sensors detect objects when light reflects back from the object. The transmitter and receiver are in the same housing, so they fit in confined spaces.
    Receiver Sensor—Receiver sensors detect objects when an object breaks the light beam between the transmitter and receiver (both included). They have a longer sensing distance than direct-sensing and reflector sensors.
    Reflector Sensor—Reflector sensors detect an object when it passes between the sensor and the reflector, interrupting the beam. They have a longer sensing distance than direct-sensing sensors.
    Sensors
    Cables
    with Plugs
    Light Beam Switch Operation
    Max. Sensing
    Distance
    Input Voltage,
    V AC
    Current
    Output, mA
    Lg.
    Ht.
    Wd.
    Dia.,
    mm
    Includes
    Housing
    Material
    Mounting Thread
    Size
    Reflector
    Dia.
    Temp. Range,
    ° F
    Performance
    Environment
    Certification
    Each
    Each
    Adjustable Direct Sensing Sensor with Infrared LED Light Beam (IP67, NEMA 4X, NEMA 13)
    On When Object Absent, On When Object Present15"24 to 2401003 5/16"1 3/16"1/2"18PlasticM18 × 1 mm0 to 155Space SavingCorrosive
    Washdown
    Submersible
    Dusty
    Oily
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    CSA Certified
    9539T400000006897K86000000
     
    Adjustable Receiver Sensor with Infrared LED Light Beam (IP67, NEMA 4X, NEMA 13)
    On When Object Absent, On When Object Present100 ft.24 to 2401003 5/16"1 3/16"1/2"18PlasticM18 × 1 mm0 to 155Space SavingCorrosive
    Washdown
    Submersible
    Dusty
    Oily
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    CSA Certified
    9539T60000006897K8600000
     
    Adjustable Reflector Sensor with Visible LED Light Beam (IP67, NEMA 4X, NEMA 13)
    On When Object Absent, On When Object Present10 ft.24 to 2401003 5/16"1 3/16"1/2"18ReflectorPlasticM18 × 1 mm3 5/16"0 to 155Space SavingCorrosive
    Washdown
    Submersible
    Dusty
    Oily
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    CSA Certified
    9539T50000006897K8600000
     
    With 4-Pole M12 Plug
    Image of Product. Front orientation. Photoelectric Sensors. Space-Saving Photoelectric Sensors , Plug In.
    Image of Specification. 4-Pole M12 Plug. Front orientation. 4 Poles. Space-Saving Photoelectric Sensors .

    4-Pole

    M12

    Plug

    Sensors with a plug connect to cables with a socket (sold separately), allowing you to quickly connect and disconnect the sensor.
    Direct Sensing—Direct sensing sensors detect objects when light reflects back from the object. The transmitter and receiver are in the same housing, so they fit in confined spaces.
    Receiver Sensor—Receiver sensors detect objects when an object breaks the light beam between the transmitter and receiver (both included). They have a longer sensing distance than direct-sensing and reflector sensors.
    Reflector Sensor—Reflector sensors detect an object when it passes between the sensor and the reflector, interrupting the beam. They have a longer sensing distance than direct-sensing sensors.
    10V DC to 30V DC Input Voltage—Sensors with DC input voltage automatically produce either PNP or NPN signal output, based on the device they are connected to.
    Light Beam Switch Operation
    Max. Sensing
    Distance
    Input Voltage,
    V DC
    Current
    Output, mA
    Output Digital
    Signal
    Lg.
    Ht.
    Wd.
    Dia.,
    mm
    Includes
    Housing
    Material
    Mounting Thread
    Size
    Reflector
    Dia.
    Temp. Range,
    ° F
    Performance
    Environment
    Certification
    Each
    Adjustable Direct Sensing Sensor with Infrared LED Light Beam (IP67, NEMA 4X, NEMA 13)
    On When Object Absent, On When Object Present15"10 to 30100PNP/NPN2 7/8"1 3/16"1/2"18PlasticM18 × 1 mm0 to 155Space SavingCorrosive
    Washdown
    Submersible
    Dusty
    Oily
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    CSA Certified
    9539T110000000
     
    Adjustable Receiver Sensor with Infrared LED Light Beam (IP67, NEMA 4X, NEMA 13)
    On When Object Absent, On When Object Present100 ft.10 to 30100PNP/NPN2 7/8"1 3/16"1/2"18PlasticM18 × 1 mm0 to 155Space SavingCorrosive
    Washdown
    Submersible
    Dusty
    Oily
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    CSA Certified
    9539T14000000
     
    Adjustable Reflector Sensor with Visible LED Light Beam (IP67, NEMA 4X, NEMA 13)
    On When Object Absent, On When Object Present10 ft.10 to 30100PNP/NPN2 7/8"1 3/16"1/2"18ReflectorPlasticM18 × 1 mm3 5/16"0 to 155Space SavingCorrosive
    Washdown
    Submersible
    Dusty
    Oily
    Outdoor
    Wet
    UL Listed
    C-UL Listed
    CE Marked
    CSA Certified
    9539T12000000
     
    Cables—M12 Socket × Wire Leads

    Harsh Environment DC Universal-Object Proximity Sensors

    Image of Product. Front orientation. Proximity Sensors. Harsh Environment DC Universal-Object Proximity Sensors.
    Image of Specification. 4-Pole M12 Plug. Front orientation. Proximity Sensors. Harsh Environment DC Universal-Object Proximity Sensors.

    4-Pole

    M12

    Plug

    Rated NEMA 6P, 12, IP68 and IP69K, these sensors protect against corrosion and high-pressure, high-temperature washdowns. Also known as capacitive proximity sensors, they remotely sense both metallic and nonmetallic objects but their strength is in sensing materials such as plastic, ceramic, and clear targets. They’re often used with programmable logic controllers (PLCs) and produce PNP or NPN signal output. To determine the signal output of a sensor you are replacing, use Testers for Proximity and Photoelectric Sensors (not included). They mount flush with the surface of any material, including metal, and are also known as embeddable or shielded sensors. The 4-pole M12 plug connects to cables with sockets (sold separately), allowing you to quickly connect and disconnect the sensor.
    Also available: If you don’t see the sensor you need, please select 2146N999 and specify manufacturer and manufacturer part number.
    Switch Starting
    Position
    Dia.,
    mm
    Max. Sensing
    Distance, mm
    Output Digital
    Signal
    Input Voltage
    Current
    Output
    Electrical
    Connection Type
    Lg.,
    mm
    Circuit Protection
    Temp. Range,
    ° F
    Enclosure Rating
    Each
    Plastic Housing with Plastic Face
     
    Flush with 4-Pole M12 Plug Connection
    1 Off and 1 On
    3016PNP10V DC to 40V DC200 mAPlug In61Reverse Polarity
    Short Circuit
    -20 to 185IP68, IP69K, NEMA 6P, NEMA 12
    2146N120000000
    1 Off and 1 On
    3016NPN10V DC to 40V DC200 mAPlug In61Reverse Polarity
    Short Circuit
    -20 to 185IP68, IP69K, NEMA 6P, NEMA 12
    2146N11000000
     
    Cables

    Noncontact Level Sensor Switches for Conductive Liquids

    Measure the level of conductive liquids without drilling a hole in your tank—these switches mount to the outside of the tank and track the capacitance between them and the tank’s contents. Use them on nonconductive plastic or glass wall tanks; they’re not compatible with metal tanks. They automatically adapt to your tank’s wall thickness, making them ready to use. These switches only respond when the liquid reaches the desired level, so foam and residue on the top of the liquid won’t trigger them early. For even more challenging setups, such as those with thick, sticky fluids, or if your tank has walls as thick as 10 mm, you can teach these switches to avoid false detections. All have LED indicators to show their power and output status.
    Made of plastic, their body is chemical resistant and NEMA and IP rated, so it keeps out dust and dirt, as well as drips of oil and jets of hot water. UL listed, C-UL listed, and CE marked, they meet U.S., Canadian, and European Union safety standards.
    Mount these switches directly on your sight glass using their adhesive back or use the included mounting bracket if you’ll need to remove them frequently. They also include foam pads for mounting them using straps around the outside of your tank.
    Level Sensor Switches with M8 4-Pin Connection
    Image of Product. With M8 4-pin Connection. Front orientation. Level Sensor Switches. Noncontact Level Sensor Switches for Conductive Liquids, Level Sensor Switches with M8 4-Pin Connection.
    Image of Specification. M8 4-pin. Front orientation. M8 Connection. Noncontact Level Sensor Switches for Conductive Liquids, 4 Pins.

    With M8 4-pin Connection

    M8

    4-pin

    Switches with an M8 4-Pin connection have a standard plug that’s easy to connect.
    PNP Output Signal—PNP switches communicate with your system by sending a positive signal.
    Output Digital
    Signal
    Wd.
    Ht.
    Thk.
    Temp. Range,
    ° F
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Enclosure Rating
    Each
    10V DC to 30V DC Input Voltage
     
    Polybutylene/Polycarbonate Body
    PNP5/8"1 5/16"5/16"-10 to 1751 Off
    SPST-NO
    0.1 amp @ 30V DCNEMA 4X, NEMA 12, IP68, IP69K, IP66
    8845N140000000
    PNP5/8"1 5/16"5/16"-10 to 1751 On
    SPST-NC
    0.1 amp @ 30V DCNEMA 4X, NEMA 12, IP68, IP69K, IP66
    8845N12000000
     
    Level Sensor Switches with Wire Lead Connection
    Image of Product. With Wire Lead Connection. Front orientation. Level Sensor Switches. Noncontact Level Sensor Switches for Conductive Liquids, Level Sensor Switches with Wire Lead Connection.

    With Wire Lead Connection

    Switches with wire leads need to be hardwired, so use them in applications where you won’t move them often.
    PNP Output Signal—PNP switches communicate with your system by sending a positive signal.
    NPN Output Signal—NPN switches send a negative signal to communicate with your system.
    Output Digital
    Signal
    Wd.
    Ht.
    Thk.
    Temp. Range,
    ° F
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Wire Lead
    Lg., ft.
    Enclosure Rating
    Each
    10V DC to 30V DC Input Voltage
     
    Polybutylene/Polycarbonate Body
    PNP5/8"1 5/16"5/16"-10 to 1751 Off
    SPST-NO
    0.1 amp @ 30V DC6NEMA 4X, NEMA 12, IP68, IP69K, IP66
    8845N130000000
    PNP5/8"1 5/16"5/16"-10 to 1751 On
    SPST-NC
    0.1 amp @ 30V DC6NEMA 4X, NEMA 12, IP68, IP69K, IP66
    8845N11000000
    NPN5/8"1 5/16"5/16"-10 to 1751 Off
    SPST-NO
    0.1 amp @ 30V DC6NEMA 4X, NEMA 12, IP68, IP69K, IP66
    8845N17000000
    NPN5/8"1 5/16"5/16"-10 to 1751 On
    SPST-NC
    0.1 amp @ 30V DC6NEMA 4X, NEMA 12, IP68, IP69K, IP66
    8845N15000000
     

    Fingerprint Scanners

    Image of Product. Front orientation. Fingerprint Scanners.
    Image of Product. Front orientation. Fingerprint Scanner Covers.

    Fingerprint

    Scanner

    Covers

    Use fingerprints to confirm the identity of personnel before granting access to secure areas or equipment. Scanners light up green to indicate that they have accepted the fingerprint and are sending an output signal. The front faces of the scanners meet NEMA 12 and IP65. The rear faces of the scanners meet IP20.
    Fingerprint Scanner Covers—Covers (sold separately) have an adhesive-back hinge, so you can stick them on to your scanner. Keep the cover flipped down to protect the scanner's sensor from dust and debris.
    Fingerprint Scanners
    Fingerprint
    Scanner Covers
    Wire
    Leads
    No. of
    Users
    No. of Fingerprints
    per User
    Switch
    Action
    Actuator
    Color
    Output Digital
    Signal
    Current
    Output, mA
    Input Voltage,
    V DC
    Bulb Voltage,
    V DC
    Dp. Behind
    Panel
    No.
    of
    Ga.
    Each
    Each
    Plastic Actuator with Wire Lead Connection
     
    For 22 mm (7/8") Diameter Panel Cutouts
    2002Momentary
    BlackPNP20020 to 303.31 9/16"322
    1911N1300000001911N101000000
     
    Plastic Actuator with 3-Pole M12 Connection
     
    For 22 mm (7/8") Diameter Panel Cutouts
    2002Momentary
    BlackPNP20020 to 303.31 9/16"1911N140000001911N10100000
     