McMaster-Carr logo
    Filter by
    Drive Type
    Electrical Phase
    Number of Speeds
    Ambient Temperature
    Louver Blade Material
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    65 Products

    Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers

    These light duty fans are designed for use without duct. They come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    120V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Control
    Type
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    10"680Not RatedDirect1,56031/1210 1/2"10 1/2"13"13"8 1/8"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    000000000000000
    12"825Not RatedDirect1,56031/1212 1/2"12 1/2"15"15"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    14"1,520Not RatedDirect1,66031/814 1/2"14 1/2"17"17"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    16"2,100Not RatedDirect1,66031/816 1/2"16 1/2"19"19"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    18"2,300Not RatedDirect1,66031/818 1/2"18 1/2"21"21"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    20"2,925Not RatedDirect1,14021/420 1/2"20 1/2"23"23"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    24"3,400Not RatedDirect1,14021/424 1/2"24 1/2"27"27"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    30"3,950Not RatedDirect1,14021/430 1/2"30 1/2"33"33"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    120V AC, Single Phase—3-Blade Plug
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Control
    Type
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    10"680Not RatedDirect1,56031/1210 1/2"10 1/2"13"13"8 1/8"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    000000000000000
    12"825Not RatedDirect1,56031/1212 1/2"12 1/2"15"15"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    14"1,520Not RatedDirect1,66031/814 1/2"14 1/2"17"17"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    16"2,100Not RatedDirect1,66031/816 1/2"16 1/2"19"19"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    18"2,300Not RatedDirect1,66031/818 1/2"18 1/2"21"21"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    20"2,925Not RatedDirect1,14021/420 1/2"20 1/2"23"23"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    24"3,400Not RatedDirect1,14021/424 1/2"24 1/2"27"27"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    30"3,950Not RatedDirect1,14021/430 1/2"30 1/2"33"33"9 1/2"100Pull SwitchSteelAluminum
    No5/16"UL Recognized Component
    00000000000000
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers .
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Certification
    Each
    20"2,820Not RatedDirect1,72011/320 1/2"20 1/2"23"23"12 1/2"100SteelAluminum
    No1/4"UL Recognized Component
    000000000000000
    24"3,950Not RatedDirect1,72011/224 1/2"24 1/2"28"28"17"100SteelAluminum
    No1/4"UL Recognized Component
    00000000000000
    30"5,745Not RatedDirect85011/230 1/2"30 1/2"33"33"15 1/4"100SteelAluminum
    No1/4"UL Recognized Component
    00000000000000

    Belt-Drive Wall-Mount Exhaust Fans with Louvers

    Image of Product. Front orientation. Exhaust Fans. Belt-Drive Wall-Mount Exhaust Fans with Louvers .
    These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Fans with an open dripproof (ODP) motor enclosure are for relatively clean, dry, indoor locations.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    30"6,00055 dB @ 5 ft.Belt55011/237"37"36 1/2"36 1/2"19"152104SteelSteelSteelNo3/16"0000000000000000
    36"8,10053 dB @ 5 ft.Belt40011/243"43"42 1/2"42 1/2"19"121104SteelSteelSteelNo3/16"000000000000000
    42"11,00057 dB @ 5 ft.Belt40013/449"49"48 1/2"48 1/2"19"270104SteelSteelSteelNo3/16"000000000000000
    48"14,90057 dB @ 5 ft.Belt3501155"55"54 1/2"54 1/2"19"266104SteelSteelSteelNo3/16"000000000000000
    Replacements for Exhaust Fans
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Frame
    Material
    Blade
    Material
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    30"6,00055 dB @ 5 ft.Belt55011/237"37"36 1/2"36 1/2"25"153104SteelSteelSteelNo3/16"0000000000000000
    36"8,10053 dB @ 5 ft.Belt40011/243"43"42 1/2"42 1/2"25"225104SteelSteelSteelNo3/16"000000000000000
    42"11,00057 dB @ 5 ft.Belt40013/449"49"48 1/2"48 1/2"25"250104SteelSteelSteelNo3/16"000000000000000
    48"14,90057 dB @ 5 ft.Belt3501155"55"54 1/2"54 1/2"25"324104SteelSteelSteelNo3/16"000000000000000
    Replacements for Exhaust Fans

    Corrosion-Resistant Direct-Drive Wall-Mount Exhaust Fans with Louvers

    Rust won't be a problem with the durable plastic housing and louvers on these fans. The fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    120/230V AC, Single Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Corrosion-Resistant Direct-Drive Wall-Mount Exhaust Fans with Louvers.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Housing
    Material
    Blade
    Material
    Each
    12"1,300Not RatedDirect1,70011/317 1/2"18 1/2"21 1/4"20 3/4"20 5/8"104FiberglassPolypropylene
    00000000000000
    16"2,400Not RatedDirect1,72511/321 1/2"23"24 5/8"24 1/8"23"104FiberglassPolypropylene
    0000000000000
    20"3,100Not RatedDirect1,70011/325 3/4"25 3/4"28 1/4"28 3/4"25 1/2"104FiberglassPolypropylene
    0000000000000
    24"4,700Not RatedDirect1,70011/231 1/2"31 1/2"34 3/8"34 1/2"27 1/2"104FiberglassPolypropylene
    0000000000000

    Direct-Drive Wall-Mount Exhaust Fans with Louvers

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Wall-Mount Exhaust Fans with Louvers.
    These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have an open dripproof (ODP) motor enclosure for relatively clean, dry, indoor locations. They also have a wire mesh inlet guard to protect the fan from debris.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Each
    10"87056 dBA @ 5 ft.Direct1,55011/2017 1/4"17 1/4"19 1/2"19 1/2"20 3/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    00000000000000000
    12"1,50060 dBA @ 5 ft.Direct1,55011/817 1/4"17 1/4"19 1/2"19 1/2"20 3/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    0000000000000000
    16"2,50061 dBA @ 5 ft.Direct1,30011/221 1/4"21 1/4"23 1/2"23 1/2"25 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    0000000000000000
    18"3,80065 dBA @ 5 ft.Direct1,30013/425 1/4"25 1/4"27 1/2"27 1/2"26 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    0000000000000000
    24"6,60067 dBA @ 5 ft.Direct1,07513/431 1/4"31 1/4"33 1/2"33 1/2"30 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    0000000000000000
    Replacement Fan Motors
    208 to 230V AC/460V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Each
    24"5,20069 dBA @ 5 ft.Direct1,12511/231 1/4"31 1/4"33 1/2"33 1/2"30 1/4"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    00000000000000000
    Replacement Fan Motors
    230/460V AC, Three Phase—Hardwire
    Cannot Be Sold to California—Fans that cannot be sold to California are restricted by local energy efficiency requirements.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Cannot Be
    Sold To
    Each
    30"8,40074 dBA @ 5 ft.Direct1,1251137 1/4"37 1/4"39 1/2"39 1/2"27 1/2"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    California00000000000000000
    36"12,30074 dBA @ 5 ft.Direct85011 1/243 1/4"43 1/4"45 1/2"45 1/2"31 1/2"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    California0000000000000000
    back to top