McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    77 Products

    Compact Solenoid On/Off Valves with Push-to-Connect Fittings

    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves with Push-to-Connect Fittings.
    Insert tubing into the fittings on these valves—no heat, solder, or flux required. They operate on electricity to automatically start and stop flow.
    Valves are fail closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    For Tube
    OD
    Gender
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Manual
    Override
    Temp. Range,
    ° F
    Seal
    Material
    Valve
    Lg.
    Overall
    Ht.
    Quick-Disconnect
    Tab Wd.
    Certification
    Each
    Polycarbonate Body with Quick-Disconnect-Terminal Wire Connection
     
    Fail Closed—24V DC
    1/4"Female0.31480 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2"3"1/4"CSA Certified
    5489T4330000000
    1/4"Female0.36740 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2"3"1/4"CSA Certified
    5489T453000000
    3/8"Female15 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2 3/8"3"1/4"CSA Certified
    5489T493000000
     
    Fail Closed—120V AC
    1/4"Female0.31480 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2"3"1/4"CSA Certified
    5489T431000000
    1/4"Female0.36740 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2"3"1/4"CSA Certified
    5489T451000000
    3/8"Female15 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2 3/8"3"1/4"CSA Certified
    5489T491000000
     
    Polysulfone Body with Quick-Disconnect-Terminal Wire Connection
     
    Fail Closed—24V DC
    1/4"Female0.228120 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2"3"1/4"CSA Certified
    5489T413000000
     
    Fail Closed—120V AC
    1/4"Female0.228120 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100Buna-N
    2"3"1/4"CSA Certified
    5489T411000000
     

    Solenoid Diverting Valves for Chemicals

    Image of Product. Front orientation. Diverting Valves. Solenoid Diverting Valves for Chemicals .
    Image of Attribute. Front orientation. Contains Annotated. Diverting Valves. Solenoid Diverting Valves for Chemicals .
    Often used for chemical analysis and other laboratory testing, these valves have a PTFE seal and body to withstand aggressive and corrosive solutions. All operate on electricity to automatically divert flow between ports. They do not require a pressure drop for operation. Any port can be used as an inlet or an outlet. Valves can direct flow from the inlet port to either outlet port. They cannot shut off flow. The actuator is mounted directly to the valve body to minimize movement and reduce wear.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Mounting
    Holes
    Pipe
    Size
    Thread
    Size
    Diverting Valve
    Flow Pattern
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Min. Pressure
    Drop Req.
    Temp. Range,
    ° F
    Actuation
    Time, sec.
    Valve
    Lg.
    Overall
    Ht.
    Mounting Fasteners
    Included
    No.
    of
    Thread
    Size
    For Use With
    Seal
    Material
    Each
    PTFE Body with Wire Leads—12V DC
     
    NPSM Female × NPSM Female × NPSM Female
    1/8
    L-Pattern15.8530 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.041 3/4"2"No74-40
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N160000000
     
    UNF Female × UNF Female × UNF Female
    1/4"-28L-Pattern10.5730 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.021 1/2"1 13/16"No74-40
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N15000000
    10-32 L-Pattern2.6430 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.023/4"1 3/16"No52-56
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N14000000
     
    PTFE Body with Wire Leads—24V DC
     
    NPSM Female × NPSM Female × NPSM Female
    1/8
    L-Pattern15.8530 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.041 3/4"2"No74-40
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N13000000
     
    UNF Female × UNF Female × UNF Female
    1/4"-28L-Pattern10.5730 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.021 1/2"1 13/16"No74-40
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N12000000
    10-32 L-Pattern2.6430 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.023/4"1 3/16"No52-56
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N11000000
     

    Electrically Operated Air Directional Control Valves with Flow Control

    Create motion and control the speed of that motion with a single valve. Also known as 4-way valves, these valves create two actions, such as extending and retracting a double-acting cylinder. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion, and adjust the volume of air exiting an air cylinder (meter out) to control speed. Apply voltage to the electrical connection to actuate.
    Push-to-Connect Male Inlet x Push-to-Connect Male Outlet
    Image of Product. Single Solenoid. Front orientation. Single Solenoid. Electrically Operated Air Directional Control Valves with Flow Control.
    Image of Product. Double Solenoid. Front orientation. Double Solenoid. Electrically Operated Air Directional Control Valves with Flow Control.

    Single Solenoid

    Double Solenoid

    5/3 (Closed Center) Flow Pattern—5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
    5/3 (Pressure Center) Flow Pattern—5/3 (pressure center) valves create two actions at the same time, such as extending two single-acting cylinders at once.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Valves
    Replacement
    Solenoids
    Inlet
    Outlet
    Overall
    No. of Flow
    Ports
    For Tube
    OD
    For Tube
    ID
    For Tube
    ID
    For Tube
    OD
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Choose a
    Voltage
    Each
    Each
    5/2 Flow Pattern
     
    Single Solenoid—Spring Return
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated4 3/4"1 3/8"2 3/4"No24V DC4666A7100000004666A610000000
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated4 3/4"1 3/8"2 3/4"No120V AC4666A720000004666A62000000
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated4 3/4"1 3/8"2 3/4"No24V DC4666A210000004666A61000000
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated4 3/4"1 3/8"2 3/4"No120V AC4666A220000004666A62000000
     
    Double Solenoid—Solenoid Return
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A5000000———0
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A1000000———0
     
    5/3 (Closed Center) Flow Pattern
     
    Double Solenoid—Solenoid Return
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A8000000———0
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A3000000———0
     
    5/3 (Pressure Center) Flow Pattern
     
    Double Solenoid—Solenoid Return
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A9000000———0
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A4000000———0
     

    Solenoid On/Off Valves for Chemicals

    To stand up to aggressive and corrosive solutions in chemical-processing applications, these valves have a plastic body and a fluoroelastomer seal. They operate on electricity to automatically start and stop flow. Valves have union fittings on each end that separate into multiple pieces for easy installation and removal from your pipeline. They come with both threaded NPT fittings and unthreaded socket-connect female fittings.
    All are fail closed unless actuated. Valves don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear. Valves meet NEMA 4 for resistance to washdowns, splashing water, corrosive liquid, and dust.
    Dark Gray PVC Body with DIN A Connection
    Image of Product. Assembled View. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Chemicals.
    Image of Product. Exploded View. Front orientation. Exploded view. Solenoid On/Off Valves. Solenoid On/Off Valves for Chemicals.

    Assembled View

    Exploded View

    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Mounting
    Slots
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    No.
    of
    Lg.
    Fasteners
    Included
    Enclosure
    Rating
    Certification
    Each
    Fail Closed—120V AC
    1/2
    FemaleNPT
    2.3120 psi @ 70° FZero Pressure Drop, Solenoid35 to 1405 1/2"6 3/8"21/4"NoNEMA 4
    CSA Certified
    4744K240000000
    3/4
    FemaleNPT
    3.2120 psi @ 70° FZero Pressure Drop, Solenoid35 to 1405 1/2"6 5/8"21/4"NoNEMA 4
    CSA Certified
    4744K25000000
    1
    FemaleNPT
    3.8120 psi @ 70° FZero Pressure Drop, Solenoid35 to 1405 1/2"6 5/8"21/4"NoNEMA 4
    CSA Certified
    4744K26000000
     
    Light Gray CPVC Body with DIN A Connection
    Image of Product. Assembled View. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Chemicals.
    Image of Product. Exploded View. Front orientation. Exploded view. Solenoid On/Off Valves. Solenoid On/Off Valves for Chemicals.

    Assembled View

    Exploded View

    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Mounting
    Slots
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    No.
    of
    Lg.
    Fasteners
    Included
    Enclosure
    Rating
    Certification
    Each
    Fail Closed—120V AC
    1/2
    FemaleNPT
    2.3120 psi @ 70° FZero Pressure Drop, Solenoid35 to 1905 5/16"6 3/8"21/4"NoNEMA 4
    CSA Certified
    4865K340000000
    3/4
    FemaleNPT
    3.2120 psi @ 70° FZero Pressure Drop, Solenoid35 to 1905 1/2"6 5/8"21/4"NoNEMA 4
    CSA Certified
    4865K35000000
    1
    FemaleNPT
    3.8120 psi @ 70° FZero Pressure Drop, Solenoid35 to 1905 1/2"6 5/8"21/4"NoNEMA 4
    CSA Certified
    4865K36000000
     

    Solenoid On/Off Valves for Drinking Water

    Safe for automated on/off control in drinking-water systems, these valves meet NSF/ANSI Standard 61. They operate on electricity to automatically start and stop flow.
    All valves are fail closed unless actuated. They require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Black PPE Body with DIN BI Connection
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Drinking Water, Black PPE Body with DIN BI Connection.
    NSF/ANSI 169—NSF/ANSI Standard 169 valves are rated for use with food equipment.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Certification
    Food Industry Std.
    Each
    Fail Closed—24V DC
    1/2
    FemaleNPT
    4.5150 psi @ 180° FPressure Drop Assisted, Solenoid35 to 1804 7/8"3 5/16"CSA Certified
    NSF/ANSI 61, NSF/ANSI 169
    2492N120000000
    3/4
    FemaleNPT
    7150 psi @ 180° FPressure Drop Assisted, Solenoid35 to 1805 3/16"3 5/8"CSA Certified
    NSF/ANSI 61, NSF/ANSI 169
    2492N14000000
    1
    FemaleNPT
    13150 psi @ 125° FPressure Drop Assisted, Solenoid35 to 1806 1/2"3 7/8"CSA Certified
    NSF/ANSI 61, NSF/ANSI 169
    2492N16000000
     
    Fail Closed—120V AC
    1/2
    FemaleNPT
    4.5150 psi @ 180° FPressure Drop Assisted, Solenoid35 to 1804 7/8"3 5/16"CSA Certified
    NSF/ANSI 61, NSF/ANSI 169
    2492N11000000
    3/4
    FemaleNPT
    7150 psi @ 180° FPressure Drop Assisted, Solenoid35 to 1805 3/16"3 5/8"CSA Certified
    NSF/ANSI 61, NSF/ANSI 169
    2492N13000000
    1
    FemaleNPT
    13150 psi @ 125° FPressure Drop Assisted, Solenoid35 to 1806 1/2"3 7/8"CSA Certified
    NSF/ANSI 61, NSF/ANSI 169
    2492N15000000
     

    High-Pressure Washdown Electrically Operated Air Directional Control Valves

    IP69K, these valves withstand high-pressure, high-temperature washdowns. Their smooth design also keeps out dust, dirt, and contaminants, so they're easy to keep clean. Apply voltage to the electrical connection to actuate. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion.
    Threaded Female Inlet × Threaded Female Outlet—Threaded Exhaust
    Image of Product. Front orientation. Directional Control Valves. High-Pressure Washdown Electrically Operated Air Directional Control Valves .
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    3 Way—3-way valves create one action, such as extending a cylinder.
    4 Way—4-way valves create two actions, such as extending and then retracting a double-acting cylinder.
    5/3 (Closed Center) Flow Pattern—5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
    2 Exhaust Ports—Valves with two exhaust ports allow you to independently control the speed of two different actions. Connect a flow control valve to each exhaust port.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall,
    mm
    Air Directional
    Control Valve Type
    Air Directional Control
    Valve Flow Pattern
    No. of Flow
    Ports
    No. of Exhaust
    Ports
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Voltage,
    V DC
    Lg.
    Wd.
    Ht.
    Each
    Single Solenoid—Spring Return
    3 Way3/23125.110.711-13 to 14526.524190.534.968.582963N120000000
    4 Way5/25225.110.711-13 to 14526.524190.534.968.582963N13000000
    4 Way5/3 (Closed Center)5225.110.711-13 to 14526.524190.534.968.582963N17000000
     
    Double Solenoid—Solenoid Return
    4 Way5/25225.110.711-13 to 14526.524190.534.968.582963N15000000
     
    Push-to-Connect Female Inlet × Push-to-Connect Female Outlet—Push-to-Connect Exhaust
    Image of Product. Front orientation. Directional Control Valves. High-Pressure Washdown Electrically Operated Air Directional Control Valves .
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    3 Way—3-way valves create one action, such as extending a cylinder.
    4 Way—4-way valves create two actions, such as extending and then retracting a double-acting cylinder.
    5/3 (Closed Center) Flow Pattern—5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
    2 Exhaust Ports—Valves with two exhaust ports allow you to independently control the speed of two different actions. Connect a flow control valve to each exhaust port.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall,
    mm
    Air Directional
    Control Valve Type
    Air Directional Control
    Valve Flow Pattern
    No. of Flow
    Ports
    No. of Exhaust
    Ports
    For Inlet
    Tube OD, mm
    For Outlet
    Tube OD, mm
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Voltage,
    V DC
    Lg.
    Wd.
    Ht.
    Each
    Single Solenoid—Spring Return
    3 Way3/2318825.110.711-13 to 14526.524190.534.976.22963N110000000
    4 Way5/2528825.110.711-13 to 14526.524190.534.976.22963N14000000
    4 Way5/3 (Closed Center)528825.110.711-13 to 14526.524190.534.976.22963N18000000
     
    Double Solenoid—Solenoid Return
    4 Way5/2528825.110.711-13 to 14526.524190.534.976.22963N16000000
     

    Food Industry Solenoid On/Off Valves with Push-to-Connect Fittings

    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Food Industry Solenoid On/Off Valves with Push-to-Connect Fittings.
    Insert tubing into the fittings on these valves—no heat, solder, or flux required. Valves meet NSF/ANSI 169 for use with food equipment. They operate on electricity to automatically start and stop flow.
    All are fail closed unless actuated. Valves don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    For Tube
    OD
    Gender
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Manual
    Override
    Temp. Range,
    ° F
    Seal
    Material
    Valve
    Lg.
    Overall
    Ht.
    Quick-Disconnect
    Tab Wd.
    Certification
    Food Industry
    Std.
    Each
    Polycarbonate Body with Quick-Disconnect-Terminal Wire Connection
     
    Fail Closed—24V DC
    1/4"Female0.31480 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100EPM Rubber2"3"1/4"CSA Certified
    NSF/ANSI 169
    5489T6330000000
    1/4"Female0.36740 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100EPM Rubber2"3"1/4"CSA Certified
    NSF/ANSI 169
    5489T653000000
     
    Fail Closed—120V AC
    1/4"Female0.31480 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100EPM Rubber2"3"1/4"CSA Certified
    NSF/ANSI 169
    5489T631000000
    1/4"Female0.36740 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100EPM Rubber2"3"1/4"CSA Certified
    NSF/ANSI 169
    5489T651000000
     
    Polysulfone Body with Quick-Disconnect-Terminal Wire Connection
     
    Fail Closed—24V DC
    1/4"Female0.228120 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100EPM Rubber2"3"1/4"CSA Certified
    NSF/ANSI 169
    5489T613000000
     
    Fail Closed—120V AC
    1/4"Female0.228120 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 100EPM Rubber2"3"1/4"CSA Certified
    NSF/ANSI 169
    5489T611000000
     

    Single-Action Electrically Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style K.

    Style K

    These valves create one action, such as extending a cylinder. Apply voltage to the electrical connection to actuate. Also known as 3-way and 3/2 valves, they direct airflow from the inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air from the system, allowing equipment to reset so the action can be repeated. Valves without an exhaust connection exhaust air to the atmosphere.
    Push to Connect Female Inlet × Push to Connect Female Outlet: Fail-Closed Valve
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style K.

    Style K

    Fail-closed valves block airflow until actuated.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Manifold Mount—Manifold-mount valves plug into a manifold (sold separately) to create multiple actions from a single pressure input. Manifolds with multiple exhaust ports have one set of inlet and exhaust ports on each side, so they can be strung together in a series. When using a single manifold, cover the ports on the side you are not using with plugs (sold separately).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    For Inlet
    Tube OD
    For Outlet
    Tube OD
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Lg.
    Wd.
    Ht.
    Mount Type
    Choose a Voltage
    Each
    Single Solenoid—Spring Return
    K35/32"5/32"Push to Connect0.60.010 to 1201 3/8"5/8"1 3/4"Manifold, Screw In12V DC, 24V DC, 120V AC62095K2000000
    K35/32"5/32"Push to Connect1.10.020 to 1201 3/8"5/8"1 3/4"Manifold, Screw In12V DC, 24V DC, 120V AC62095K100000
     
    Accessories for Directional Control Valves

    Solenoid On/Off Valves with Flow Adjustment

    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves with Flow Adjustment.
    Turn the knob to adjust how much these valves will open or close when actuated. They are often used in irrigation and landscaping applications. All operate on electricity to automatically start and stop flow.
    These valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Fail-Closed Valve—Fail closed valves are closed unless actuated.
    Fail-Open Valve—Fail open valves are open unless actuated.
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Seal
    Material
    Valve
    Lg.
    Overall
    Ht.
    Each
    Nylon Body with Wire Lead Connection
     
    Fail Closed—24V AC
    1
    FemaleNPT
    Not Rated175 psi @ 70° FPressure Drop Assisted, Solenoid35 to 150EPDM
    4 1/4"5 1/2"4903K971000000
    1 1/2
    FemaleNPT
    Not Rated160 psi @ 70° FPressure Drop Assisted, Solenoid35 to 150EPDM
    5 13/16"7 1/16"4903K981000000
    2
    FemaleNPT
    Not Rated160 psi @ 70° FPressure Drop Assisted, Solenoid35 to 150EPDM
    6 1/2"8 1/2"4903K991000000
     
    Fail Closed—120V AC
    1
    FemaleNPT
    Not Rated175 psi @ 70° FPressure Drop Assisted, Solenoid35 to 150EPDM
    4 1/4"5 1/2"4903K97200000
    1 1/2
    FemaleNPT
    Not Rated160 psi @ 70° FPressure Drop Assisted, Solenoid35 to 150EPDM
    5 13/16"7 1/16"4903K982000000
    2
    FemaleNPT
    Not Rated160 psi @ 70° FPressure Drop Assisted, Solenoid35 to 150EPDM
    6 1/2"8 1/2"4903K992000000
     
    Fail Open—24V AC
    1
    FemaleNPT
    Not Rated175 psi @ 70° FPressure Drop Assisted, Solenoid35 to 150EPDM
    4 1/4"5 15/16"4903K762000000
     
    Fail Open—120V AC
    1
    FemaleNPT
    Not Rated175 psi @ 70° FPressure Drop Assisted, Solenoid35 to 150EPDM
    4 1/4"5 15/16"4903K661000000
     

    Two-Speed Two-Action Electrically Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style K.

    Style K

    Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as 4-way and 5/2 valves, they actuate when voltage is applied to the electrical connection. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion.
    Push-to-Connect Female Inlet × Push-to-Connect Female Outlet—Push-to-Connect Exhaust
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style K.

    Style K

    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    For Inlet
    Tube OD, mm
    For Outlet
    Tube OD, mm
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Voltage,
    V DC
    Each
    Single Solenoid—Spring Return
    K56617.50.3144 to 10129.523 1/8"7/16"2 1/8"Screw In244658A310000000
     
    Double Solenoid—Solenoid Return
    K56617.50.3129 to 10129.523 1/4"7/16"2 1/8"Screw In244658A32000000
     

    Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Full Shut-Off

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Full Shut-Off, Style C.

    Style C

    These valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Apply voltage to the electrical connection to actuate. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Also known as 4-way and 5/3 closed center valves.
    Push-to-Connect Female Inlet × Push-to-Connect Female Outlet—Push-to-Connect Exhaust
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Full Shut-Off, Style C.

    Style C

    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    For Inlet
    Tube OD, mm
    For Outlet
    Tube OD, mm
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Voltage,
    V DC
    Each
    Double Solenoid—Spring Return
    C56617.50.3144 to 10129.523 1/4"7/16"2 1/8"Screw In244658A330000000
     
    Directional Control Valve Station Plates

    Robot-Arm-Mounted Electrically Operated Air Directional Control Valves

    Image of System. Front orientation. Contains Annotated. Directional Control Valves. Robot-Arm-Mounted Electrically Operated Air Directional Control Valves.
    Image of Product. Front orientation. Directional Control Valves. Robot-Arm-Mounted Electrically Operated Air Directional Control Valves.
    Control air-powered robot tools, such as pick-and-place grippers. These valves have two three-way valves, also known as 3/2 valves, that you can control separately with your robot’s program. For example, you can connect two single-acting tools, such as two grippers with spring jaw returns, using one valve for each. Alternatively, use both valves for one double-acting tool, such as an air cylinder—one valve pushes the cylinder out, the other pulls it back. In both setups, air escapes through vents on the side of the manifold.
    These valves come with everything you need for quick installation. Use the hook and loop straps to mount them to your robot arm, then plug the electrical cord into the M8 connection at the end of the arm. Connect your compressed air line to the inlet. Last, run tubing from the valve to your robot tool.
    Inlet
    Outlet
    No. of Flow
    Ports
    Connection
    For Tube
    OD, mm
    Connection
    For Tube
    OD, mm
    Max. Flow Rate
    @ Pressure
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Each
    3Push to Connect6Push to Connect62 scfm @ 80 psi0.090 to 1009015N110000000

    Robot-Arm-Mounted Electrically Operated Air On/Off Valves

    Image of ProductInUse. Front orientation. Contains Annotated. Solenoid On/Off Valves. Robot-Arm-Mounted Electrically Operated Air On/Off Valves.
    Image of Product. Front orientation. Solenoid On/Off Valves. Robot-Arm-Mounted Electrically Operated Air On/Off Valves.
    Control the flow of air to robot tools from your robot's program. Often used with air-powered vacuum lifters, these electrically controlled valves open to supply air to the lifter, generating suction to pick up a part. When these valves close, the suction stops and the part drops. An integrated switch monitors the tool’s vacuum level via analog signals, so you know if a part was successfully picked. A built-in LED display shows the vacuum status and lets you change vacuum setpoints.
    These valves come with everything you need for quick installation. Use the hook and loop straps to mount them to your robot arm, then plug the electrical cord into the M8 connection at the end of the arm. Connect your compressed air line to the inlet. Last, run tubing from the valve to your robot tool.
    Rapid Part Release—Valves with rapid part release can send a burst of air to push a part off your vacuum lifter, so you don’t have to wait for it to drop. They’re often used for pick-and-place applications requiring high speed and precision.
    Inlet
    Outlet
    Overall
    Max. Pressure,
    psi
    Flow Coefficient
    (Cv)
    Max. Flow Rate @
    80 psi, scfm
    Connection
    For Tube
    OD, mm
    Connection
    For Tube
    OD, mm
    Temp. Range,
    ° F
    Lg.
    Ht.
    Each
    Valves with Vacuum Monitoring
    1000.246Push to Connect6Push to Connect635 to 1202 5/8"4 1/8"8880N130000000
     
    Valves with Rapid Part Release and Vacuum Monitoring
    1000.246Push to Connect6Push to Connect635 to 1203 1/2"4 1/8"8880N11000000
     

    Compact Solenoid On/Off Valves for Coolant

    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, Acetal Body with Wire Lead Connection.

    Acetal

    Body with

    Wire Lead

    Connection

    Reduce your pipeline footprint with these low-profile valves that are about half the size of standard valves for coolant. They operate on electricity to automatically start and stop flow.
    Valves are fail closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Mounting
    Holes
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Manual
    Override
    Temp. Range,
    ° F
    Seal Material
    Valve
    Lg.
    Overall
    Ht.
    No.
    of
    Dia.
    Fasteners
    Included
    Each
    Acetal Body with Wire Lead Connection
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.09300 psi @ 150° FZero Pressure Drop, SolenoidNo0 to 150Fluoroelastomer
    1 5/16"2 1/4"21/4"No5760T121000000
     
    back to top