    Solenoid Diverting Valves for Chemicals

    Image of Product. Front orientation. Diverting Valves. Solenoid Diverting Valves for Chemicals .
    Image of Attribute. Front orientation. Contains Annotated. Diverting Valves. Solenoid Diverting Valves for Chemicals .
    Often used for chemical analysis and other laboratory testing, these valves have a PTFE seal and body to withstand aggressive and corrosive solutions. All operate on electricity to automatically divert flow between ports. They do not require a pressure drop for operation. Any port can be used as an inlet or an outlet. Valves can direct flow from the inlet port to either outlet port. They cannot shut off flow. The actuator is mounted directly to the valve body to minimize movement and reduce wear.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Mounting
    Holes
    Pipe
    Size
    Thread
    Size
    Diverting Valve
    Flow Pattern
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Min. Pressure
    Drop Req.
    Temp. Range,
    ° F
    Actuation
    Time, sec.
    Valve
    Lg.
    Overall
    Ht.
    Mounting Fasteners
    Included
    No.
    of
    Thread
    Size
    For Use With
    Seal
    Material
    Each
    PTFE Body with Wire Leads—12V DC
     
    NPSM Female × NPSM Female × NPSM Female
    1/8
    L-Pattern15.8530 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.041 3/4"2"No74-40
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N160000000
     
    UNF Female × UNF Female × UNF Female
    1/4"-28L-Pattern10.5730 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.021 1/2"1 13/16"No74-40
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N15000000
    10-32 L-Pattern2.6430 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.023/4"1 3/16"No52-56
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N14000000
     
    PTFE Body with Wire Leads—24V DC
     
    NPSM Female × NPSM Female × NPSM Female
    1/8
    L-Pattern15.8530 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.041 3/4"2"No74-40
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N13000000
     
    UNF Female × UNF Female × UNF Female
    1/4"-28L-Pattern10.5730 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.021 1/2"1 13/16"No74-40
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N12000000
    10-32 L-Pattern2.6430 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.023/4"1 3/16"No52-56
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N11000000
     

    Solenoid On/Off Valves for Coolant and Detergent

    These valves operate on electricity to automatically start and stop flow. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Brass Body with Wire Lead Connection—Fluoroelastomer Seal
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Coolant and Detergent, Brass Body with Wire Lead Connection—Fluoroelastomer Seal.
    Fail-Closed Valve—Fail closed valves are closed unless actuated.
    Fail-Open Valve—Fail open valves are open unless actuated.
    Zero Pressure Drop Valve—Zero pressure drop valves don’t require a minimum pressure drop between the inlet and outlet for operation.
    IP65 Enclosure Rating—Valves rated IP65 and/or NEMA 4 resist washdowns, splashing water, and dust.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Enclosure Rating—Enclosure ratings only apply to the valve’s enclosure.
    Valves
    Repair Kits
    Solenoid Coils
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Certification
    Each
    Each
    Each
    Fail Closed—24V AC
    3/8
    FemaleNPT
    4.390 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K41200000002836N10000002835N5000000
    1/2
    FemaleNPT
    4.390 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K5120000002836N1000002835N500000
    3/4
    FemaleNPT
    6.790 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4 1/8"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K6120000002836N2000002835N500000
    1
    FemaleNPT
    11100 psi @ 125° FZero Pressure Drop, Solenoid0 to 2303 11/16"5 1/8"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K780000002836N50000002835N500000
    1 1/4
    FemaleNPT
    18100 psi @ 125° FZero Pressure Drop, Solenoid0 to 2304 3/8"5 3/4"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K810000002836N60000002835N500000
    1 1/2
    FemaleNPT
    23100 psi @ 125° FZero Pressure Drop, Solenoid0 to 2304 3/8"5 3/4"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K830000002836N60000002835N500000
     
    Fail Closed—24V DC
    3/8
    FemaleNPT
    4.370 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K740000002836N3000002835N600000
    1/2
    FemaleNPT
    4.370 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K750000002836N80000002835N400000
    3/4
    FemaleNPT
    6.770 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4 1/8"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K760000002836N4000002835N600000
     
    Fail Closed—120V AC
    3/8
    FemaleNPT
    4.390 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K4110000002836N1000002835N400000
    1/2
    FemaleNPT
    4.390 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K5110000002836N1000002835N400000
    3/4
    FemaleNPT
    6.790 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4 1/8"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K6110000002836N2000002835N400000
    1
    FemaleNPT
    11100 psi @ 125° FZero Pressure Drop, Solenoid0 to 2303 11/16"5 1/8"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K770000002836N50000002835N400000
    1 1/4
    FemaleNPT
    18100 psi @ 125° FZero Pressure Drop, Solenoid0 to 2304 3/8"5 3/4"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K790000002836N60000002835N400000
    1 1/2
    FemaleNPT
    23100 psi @ 125° FZero Pressure Drop, Solenoid0 to 2304 3/8"5 3/4"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K820000002836N60000002835N400000
     
    Fail Open—24V AC
    3/8
    FemaleNPT
    3.3200 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4 1/2"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K85000000———0———0
    1/2
    FemaleNPT
    4.3200 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4 1/2"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K88000000———0———0
    3/4
    FemaleNPT
    6.7200 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4 5/8"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K92000000———0———0
     
    Fail Open—24V DC
    3/8
    FemaleNPT
    3.3125 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4 1/2"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K860000002836N8000000———0
    1/2
    FemaleNPT
    4.3125 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4 1/2"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K89000000———0———0
    3/4
    FemaleNPT
    6.7125 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4 5/8"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K930000002836N11000000———0
     
    Fail Open—120V AC
    3/8
    FemaleNPT
    3.3200 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4 1/2"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K840000002836N7000000———0
    1/2
    FemaleNPT
    4.3200 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4 1/2"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K87000000———0———0
    3/4
    FemaleNPT
    6.7200 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 3/4"4 5/8"IP65, NEMA 4X
    UL Listed, CSA Certified
    48765K910000002836N9000000———0
     
    Nickel-Plated Brass Body with DIN A Connection—Fluoroelastomer Seal
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Coolant and Detergent, Nickel-Plated Brass Body with DIN A Connection—Fluoroelastomer Seal.
    Nickel-plated brass valves are more corrosion resistant than plain brass valves.
    Fail-Closed Valve—Fail closed valves are closed unless actuated.
    Pressure Drop Assisted Valve—Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
    IP65 Enclosure Rating and NEMA 4 Enclosure Rating—Valves rated IP65 and/or NEMA 4 resist washdowns, splashing water, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Enclosure Rating—Enclosure ratings only apply to the valve’s enclosure.
    Valves
    Repair Kits
    Solenoid Coils
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Each
    Each
    Each
    Fail Closed—24V DC
    1/4
    FemaleNPT
    1.4150 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2802"3 1/2"IP65, NEMA 4
    7944K3200000002875N250000002881N18000000
    3/8
    FemaleNPT
    1.8150 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2802"3 1/2"IP65, NEMA 4
    7944K340000002875N25000002881N1800000
    1/2
    FemaleNPT
    1.8150 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2802 7/8"3 1/2"IP65, NEMA 4
    7944K360000002875N25000002881N1800000
    3/4
    FemaleNPT
    9.8230 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2804 1/8"4 1/8"IP65, NEMA 4
    7944K380000002875N26000002881N1800000
    1
    FemaleNPT
    13230 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2804 1/8"4 3/8"IP65, NEMA 4
    7944K410000002875N26000002881N1800000
    1 1/4
    FemaleNPT
    28150 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2805 5/8"5 1/8"IP65, NEMA 4
    7944K470000002875N270000002881N1800000
    1 1/2
    FemaleNPT
    36150 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2805 5/8"5 1/8"IP65, NEMA 4
    7944K440000002875N270000002881N1800000
    2
    FemaleNPT
    53150 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2806 3/4"5 1/2"IP65, NEMA 4
    7944K460000002875N280000002881N1800000
     
    Fail Closed—120V AC
    1/4
    FemaleNPT
    1.4300 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2802"3 1/2"IP65, NEMA 4
    7944K2120000002875N25000002881N1100000
    3/8
    FemaleNPT
    1.8300 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2802"3 1/2"IP65, NEMA 4
    7944K2220000002875N25000002881N1100000
    1/2
    FemaleNPT
    1.8300 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2802 7/8"3 1/2"IP65, NEMA 4
    7944K2320000002875N25000002881N1100000
    3/4
    FemaleNPT
    9.8230 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2804 1/8"4 1/8"IP65, NEMA 4
    7944K2420000002875N26000002881N1100000
    1
    FemaleNPT
    13230 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2804 1/8"4 3/8"IP65, NEMA 4
    7944K2520000002875N26000002881N1100000
    1 1/4
    FemaleNPT
    28150 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2805 5/8"5 1/8"IP65, NEMA 4
    7944K2620000002875N270000002881N1100000
    1 1/2
    FemaleNPT
    36150 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2805 5/8"5 1/8"IP65, NEMA 4
    7944K2720000002875N270000002881N1100000
    2
    FemaleNPT
    53150 psi @ 70° FPressure Drop Assisted, Solenoid15 to 2806 3/4"5 1/2"IP65, NEMA 4
    7944K2820000002875N280000002881N1100000
     
    304 Stainless Steel Body with Wire Lead Connection—Glass-Filled PTFE Seal
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Coolant and Detergent, 304 Stainless Steel Body with Wire Lead Connection—Glass-Filled PTFE Seal.
    304 stainless steel valves are more corrosion resistant than nickel-plated and plain brass valves.
    Fail-Closed Valve—Fail closed valves are closed unless actuated.
    Zero Pressure Drop Valve—Zero pressure drop valves don’t require a minimum pressure drop between the inlet and outlet for operation.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valves
    Solenoid Coils
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Each
    Each
    Fail Closed—120V AC
    1/2
    FemaleNPT
    3.5110 psi @ 400° FZero Pressure Drop, Solenoid-320 to 4003 1/4"7 3/16"8117K3500000002885N130000000
    1/2
    FemaleNPT
    3.5200 psi @ 400° FZero Pressure Drop, Solenoid-320 to 4003 1/4"7 3/16"8117K360000002885N13000000
    1/2
    FemaleNPT
    3.5300 psi @ 400° FZero Pressure Drop, Solenoid-320 to 4003 1/4"8"8117K37000000002885N15000000
    3/4
    FemaleNPT
    7.5110 psi @ 400° FZero Pressure Drop, Solenoid-320 to 4003 1/2"7 5/16"8117K45000000002885N13000000
    1
    FemaleNPT
    13110 psi @ 400° FZero Pressure Drop, Solenoid-320 to 4004 1/8"8"8117K55000000002885N11000000
    1
    FemaleNPT
    13200 psi @ 400° FZero Pressure Drop, Solenoid-320 to 4004 1/8"8 7/8"8117K56000000002885N15000000
     
    316 Stainless Steel Body with Wire Lead Connection—Fluoroelastomer Seal
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Coolant and Detergent, 316 Stainless Steel Body with Wire Lead Connection—Fluoroelastomer Seal.
    316 stainless steel valves have excellent corrosion resistance.
    Fail-Closed Valve—Fail closed valves are closed unless actuated.
    Zero Pressure Drop Valve—Zero pressure drop valves don’t require a minimum pressure drop between the inlet and outlet for operation.
    IP65 Enclosure Rating—Valves rated IP65 and/or NEMA 4 resist washdowns, splashing water, and dust.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Enclosure Rating—Enclosure ratings only apply to the valve’s enclosure.
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Certification
    Each
    Fail Closed—120V AC
    3/8
    FemaleNPT
    4.390 psi @ 125° FZero Pressure Drop, Solenoid0 to 2302 13/16"3 15/16"IP65, NEMA 4X
    UL Listed, CSA Certified
    47795K150000000
     
    316 Stainless Steel Body with Wire Lead Connection—Viton® Fluoroelastomer Seal
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Coolant and Detergent, 316 Stainless Steel Body with Wire Lead Connection—Viton® Fluoroelastomer Seal.
    316 stainless steel valves have excellent corrosion resistance.
    Fail-Closed Valve—Fail closed valves are closed unless actuated.
    Zero Pressure Drop Valve—Zero pressure drop valves don’t require a minimum pressure drop between the inlet and outlet for operation.
    IP50 Enclosure Rating and NEMA 2 Enclosure Rating—Valves rated IP50 and NEMA 2 resist water and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Enclosure Rating—Enclosure ratings only apply to the valve’s enclosure.
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Certification
    Each
    Fail Closed—120V AC
    1/2
    FemaleNPT
    Not Rated150 psi @ 70° FZero Pressure Drop, Solenoid0 to 3003 1/2"4 1/8"IP50, NEMA 2
    UL Listed, CSA Certified
    47795K12000000000
    3/4
    FemaleNPT
    Not Rated150 psi @ 70° FZero Pressure Drop, Solenoid0 to 3003 1/2"4 1/8"IP50, NEMA 2
    UL Listed, CSA Certified
    47795K1300000000
    1
    FemaleNPT
    Not Rated150 psi @ 70° FZero Pressure Drop, Solenoid0 to 3003 1/2"4 7/16"IP50, NEMA 2
    UL Listed, CSA Certified
    47795K1400000000
     
    316 Stainless Steel Body with Wire Lead Connection—PTFE Seal
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Coolant and Detergent, 316 Stainless Steel Body with Wire Lead Connection—PTFE Seal.
    316 stainless steel valves have excellent corrosion resistance.
    Fail-Closed Valve—Fail closed valves are closed unless actuated.
    Pressure Drop Assisted Valve—Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Enclosure Rating—Enclosure ratings only apply to the valve’s enclosure.
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Each
    Fail Closed—120V AC
    1/2
    FemaleNPT
    31,000 psi @ 300° FPressure Drop Assisted, Solenoid-40 to 3003 1/8"5 1/4"NEMA 4X
    4665K2240000000
    1
    FemaleNPT
    61,000 psi @ 300° FPressure Drop Assisted, Solenoid-40 to 3004 3/16"6"NEMA 4X
    4665K22500000000
     

    Compact Solenoid On/Off Valves for Coolant

    Image of Product. Back orientation. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, Brass Body with DIN A Connection.
    Image of Product. Back orientation. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, Brass Body with DIN B Connection.
    Image of Product. Back orientation. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, Brass Body with DIN BI Connection.
    Image of Product. Back orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, Brass Body with DIN C Connection.

    Brass Body

    with DIN A

    Connection

    Brass Body

    with DIN B

    Connection

    Brass Body

    with DIN BI

    Connection

    Brass Body

    with DIN C

    Connection

    Image of Product. Back orientation. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, 303 Stainless Steel Body with DIN C Connection.
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, 303 Stainless Steel Body with Wire Lead Connection.
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Compact Solenoid On/Off Valves for Coolant, Acetal Body with Wire Lead Connection.

    303

    Stainless

    Steel

    Body with

    DIN C

    Connection

    303 Stainless

    Steel Body with

    Wire Lead

    Connection

    Acetal

    Body with

    Wire Lead

    Connection

    Reduce your pipeline footprint with these low-profile valves that are about half the size of standard valves for coolant. They operate on electricity to automatically start and stop flow.
    Valves are fail closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Brass Body—Brass valves are more durable than acetal valves.
    303 Stainless Steel Body—303 stainless steel valves are more durable than acetal valves. They are more corrosion resistant than brass valves.
    IP65 Enclosure Rating—IP65 valves resist low-pressure jets of water and dust.
    IP67 Enclosure Rating—IP67 valves are dust tight and protected from temporary submersion.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valve
    Mounting
    Holes
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Manual
    Override
    Temp. Range,
    ° F
    Seal Material
    Lg.
    Dia.
    Overall
    Ht.
    No.
    of
    Dia.
    Fasteners
    Included
    Enclosure
    Rating
    Certification
    Each
    Brass Body with DIN A Connection
     
    Fail Closed—24V AC
    1/4
    FemaleNPT
    0.35218 psi @ 140° FZero Pressure Drop, SolenoidNo32 to 266Fluoroelastomer
    1 11/16"3 3/8"IP67
    CE Marked
    4807T129000000
     
    Fail Closed—24V DC
    1/4
    FemaleNPT
    0.35130 psi @ 140° FZero Pressure Drop, SolenoidNo32 to 260Fluoroelastomer
    1 11/16"3 3/8"IP67
    CE Marked
    4807T13800000
     
    Brass Body with DIN B Connection
     
    Fail Closed—24V AC
    1/8
    FemaleNPT
    0.16280 psi @ 140° FZero Pressure Drop, SolenoidNo32 to 260Fluoroelastomer
    1 5/16"2 3/4"IP67
    CE Marked
    4807T11800000
     
    Brass Body with DIN BI Connection
     
    Fail Closed—24V AC
    1/8
    FemaleNPT
    0.21102 psi @ 140° FZero Pressure Drop, SolenoidNo32 to 266Fluoroelastomer
    1 5/16"2 3/4"IP67
    CE Marked
    4807T12800000
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.2172 psi @ 140° FZero Pressure Drop, SolenoidNo35 to 140Fluoroelastomer
    1 5/16"2 5/8"IP67
    CE Marked
    4807T12500000
     
    Brass Body with DIN C Connection
     
    Fail Closed—24V AC
    1/8
    FemaleNPT
    0.07170 psi @ 195° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7994K212000000
    1/8
    FemaleNPT
    0.13115 psi @ 195° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7994K222000000
     
    Fail Closed—24V DC
    1/8
    FemaleNPT
    0.01540 psi @ 195° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7994K233000000
    1/8
    FemaleNPT
    0.0785 psi @ 195° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7994K213000000
    1/8
    FemaleNPT
    0.1365 psi @ 195° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7994K223000000
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.07170 psi @ 195° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7994K211000000
    1/8
    FemaleNPT
    0.13115 psi @ 195° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7994K221000000
    1/8
    FemaleNPT
    0.1585 psi @ 195° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7994K231000000
     
    303 Stainless Steel Body with DIN C Connection
     
    Fail Closed—24V DC
    1/8
    FemaleNPT
    0.0785 psi @ 210° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7900K111000000
    1/8
    FemaleNPT
    0.1365 psi @ 210° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7900K113000000
    1/8
    FemaleNPT
    0.1540 psi @ 210° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7900K122000000
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.07175 psi @ 210° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7900K112000000
    1/8
    FemaleNPT
    0.13115 psi @ 210° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7900K121000000
    1/8
    FemaleNPT
    0.1585 psi @ 210° FZero Pressure Drop, SolenoidNo10 to 210Fluoroelastomer
    1"2 1/8"IP65
    7900K123000000
     
    303 Stainless Steel Body with Wire Lead Connection
     
    Fail Closed—24V DC
    1/8
    FemaleNPT
    0.06390 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 210Fluoroelastomer
    1"2 5/8"NEMA 4X
    UL Listed, C-UL Listed
    7900K841000000
    1/8
    FemaleNPT
    0.22130 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 210Fluoroelastomer
    1"2 5/8"NEMA 4X
    UL Listed, C-UL Listed
    7900K851000000
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.06950 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 210Fluoroelastomer
    1"2 5/8"NEMA 4X
    UL Listed, C-UL Listed
    7900K843000000
    1/8
    FemaleNPT
    0.22320 psi @ 70° FZero Pressure Drop, SolenoidNo35 to 210Fluoroelastomer
    1"2 5/8"NEMA 4X
    UL Listed, C-UL Listed
    7900K853000000
     
    Acetal Body with Wire Lead Connection
     
    Fail Closed—120V AC
    1/8
    FemaleNPT
    0.09300 psi @ 150° FZero Pressure Drop, SolenoidNo0 to 150Fluoroelastomer
    1 5/16"2 1/4"21/4"No5760T12100000
     

    Solenoid On/Off Valves for Chemicals

    To stand up to aggressive and corrosive solutions in chemical-processing applications, these valves have a plastic body and a fluoroelastomer seal. They operate on electricity to automatically start and stop flow. Valves have union fittings on each end that separate into multiple pieces for easy installation and removal from your pipeline. They come with both threaded NPT fittings and unthreaded socket-connect female fittings.
    All are fail closed unless actuated. Valves don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear. Valves meet NEMA 4 for resistance to washdowns, splashing water, corrosive liquid, and dust.
    Dark Gray PVC Body with DIN A Connection
    Image of Product. Assembled View. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Chemicals.
    Image of Product. Exploded View. Front orientation. Exploded view. Solenoid On/Off Valves. Solenoid On/Off Valves for Chemicals.

    Assembled View

    Exploded View

    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Mounting
    Slots
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    No.
    of
    Lg.
    Fasteners
    Included
    Enclosure
    Rating
    Certification
    Each
    Fail Closed—120V AC
    1/2
    FemaleNPT
    2.3120 psi @ 70° FZero Pressure Drop, Solenoid35 to 1405 1/2"6 3/8"21/4"NoNEMA 4
    CSA Certified
    4744K240000000
    3/4
    FemaleNPT
    3.2120 psi @ 70° FZero Pressure Drop, Solenoid35 to 1405 1/2"6 5/8"21/4"NoNEMA 4
    CSA Certified
    4744K25000000
    1
    FemaleNPT
    3.8120 psi @ 70° FZero Pressure Drop, Solenoid35 to 1405 1/2"6 5/8"21/4"NoNEMA 4
    CSA Certified
    4744K26000000
     

    Solenoid On/Off Valves with Exhaust Port for Coolant

    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves with Exhaust Port for Coolant.
    Often used to control single-acting, spring-return air cylinders, these valves have a third threaded port to exhaust media. They operate on electricity to automatically start and stop flow.
    These valves are fail closed and exhaust media unless actuated; when actuated, they close the exhaust port and reverse the direction of flow to send media to equipment. Valves don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear. Valves meet NEMA 4X for resistance to washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Seal Material
    Valve
    Lg.
    Overall
    Ht.
    No. of
    Ports
    Enclosure
    Rating
    Certification
    Each
    Brass Body with Wire Lead Connection and Side Exhaust Port
     
    Fail Closed—120V AC
    1/4
    FemaleNPT
    0.08125 psi @ 70° FZero Pressure Drop, Solenoid-10 to 200Fluoroelastomer
    1 11/16"3 1/2"3NEMA 4X
    UL Listed, CSA Certified
    8111K4410000000
     

    Solenoid On/Off Valves with Flow Adjustment for Coolant

    Image of Product. With Flow-Adjustment Screw. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves with Flow Adjustment for Coolant, Brass Body with Wire Lead Connection, Flow-Adjustment Screw.
    Image of Product. With Flow-Adjustment Knob. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves with Flow Adjustment for Coolant, Brass Body with Wire Lead Connection, Flow-Adjustment Knob.

    With Flow-Adjustment Screw

    With Flow-Adjustment Knob

    To change the flow rate of antifreeze and cleaning solutions, use the adjustment screw or knob to manually set how much these valves will open when actuated. They operate on electricity to automatically start and stop flow.
    All valves are fail closed unless actuated. They require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Pipe
    Size
    Gender
    Thread
    Type
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Flow Adjustment
    Mechanism
    Each
    Brass Body with Wire Lead Connection
     
    Fail Closed—24V AC
    3/4
    FemaleNPT
    200 psi @ 70° FPressure Drop Assisted, Solenoid35 to 1503 11/16"4"Screw4903K8610000000
    1
    FemaleNPT
    200 psi @ 70° FPressure Drop Assisted, Solenoid35 to 1504 3/8"5 1/4"Knob4903K871000000
    1 1/4
    FemaleNPT
    200 psi @ 70° FPressure Drop Assisted, Solenoid35 to 1504 3/4"5 3/4"Knob4903K881000000
    1 1/2
    FemaleNPT
    200 psi @ 70° FPressure Drop Assisted, Solenoid35 to 1505 5/8"7 1/4"Knob4903K891000000
    2
    FemaleNPT
    200 psi @ 70° FPressure Drop Assisted, Solenoid35 to 1505 5/8"7 1/4"Knob4903K961000000
     
    Fail Closed—120V AC
    3/4
    FemaleNPT
    200 psi @ 70° FPressure Drop Assisted, Solenoid35 to 1503 11/16"4"Screw4903K862000000
    1
    FemaleNPT
    200 psi @ 70° FPressure Drop Assisted, Solenoid35 to 1504 3/8"5 1/4"Knob4903K872000000
    1 1/4
    FemaleNPT
    200 psi @ 70° FPressure Drop Assisted, Solenoid35 to 1504 3/4"5 3/4"Knob4903K882000000
    1 1/2
    FemaleNPT
    200 psi @ 70° FPressure Drop Assisted, Solenoid35 to 1505 5/8"7 1/4"Knob4903K892000000
    2
    FemaleNPT
    200 psi @ 70° FPressure Drop Assisted, Solenoid35 to 1505 5/8"7 1/4"Knob4903K962000000
     
    back to top