    8 Products

    Solenoid Diverting Valves for Chemicals

    Image of Product. Front orientation. Diverting Valves. Solenoid Diverting Valves for Chemicals .
    Image of Attribute. Front orientation. Contains Annotated. Diverting Valves. Solenoid Diverting Valves for Chemicals .
    Often used for chemical analysis and other laboratory testing, these valves have a PTFE seal and body to withstand aggressive and corrosive solutions. All operate on electricity to automatically divert flow between ports. They do not require a pressure drop for operation. Any port can be used as an inlet or an outlet. Valves can direct flow from the inlet port to either outlet port. They cannot shut off flow. The actuator is mounted directly to the valve body to minimize movement and reduce wear.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Mounting
    Holes
    Pipe
    Size
    Thread
    Size
    Diverting Valve
    Flow Pattern
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Min. Pressure
    Drop Req.
    Temp. Range,
    ° F
    Actuation
    Time, sec.
    Valve
    Lg.
    Overall
    Ht.
    Mounting Fasteners
    Included
    No.
    of
    Thread
    Size
    For Use With
    Seal
    Material
    Each
    PTFE Body with Wire Leads—12V DC
     
    NPSM Female × NPSM Female × NPSM Female
    1/8
    L-Pattern15.8530 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.041 3/4"2"No74-40
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N160000000
     
    UNF Female × UNF Female × UNF Female
    1/4"-28L-Pattern10.5730 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.021 1/2"1 13/16"No74-40
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N15000000
    10-32 L-Pattern2.6430 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.023/4"1 3/16"No52-56
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N14000000
     
    PTFE Body with Wire Leads—24V DC
     
    NPSM Female × NPSM Female × NPSM Female
    1/8
    L-Pattern15.8530 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.041 3/4"2"No74-40
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N13000000
     
    UNF Female × UNF Female × UNF Female
    1/4"-28L-Pattern10.5730 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.021 1/2"1 13/16"No74-40
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N12000000
    10-32 L-Pattern2.6430 psi @ 70° FSolenoid, Zero Pressure DropNone35 to 1550.023/4"1 3/16"No52-56
    Acetone, Air, Ammonia, Argon, Chlorine, Citric Acid, Deionized Water, Diesel Fuel, Ethylene Glycol, Fuel Oil, Helium, Hydrochloric Acid, Krypton, Methanol (Methyl Alcohol), Neon, Nitric Acid, Oil, Oxygen, Phosphoric Acid, Salt Water, Sulfuric Acid, Water, Xenon, XylenePTFE
    2552N11000000
     

    Solenoid On/Off Valves for Fuel Oil

    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Fuel Oil.
    Supply fuel oil to boilers, furnaces, and other heating equipment. These valves operate on electricity to automatically start and stop flow.
    All are fail closed unless actuated. The actuator is directly mounted to the valve body to minimize movement and reduce wear. Valves meet NEMA 4X for resistance to washdowns, splashing water, corrosive liquid, and dust.
    Zero Pressure Drop Valve—Zero pressure drop valve does not require a minimum pressure drop between the inlet and outlet for operation.
    Pressure Drop Assisted Valve—Pressure drop assisted valve requires a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Manual
    Override
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Fasteners
    Included
    Enclosure
    Rating
    Certification
    Each
    Brass Body with Wire Lead Connection
     
    Fail Closed—120V AC
    1/4
    FemaleNPT
    0.76300 psi @ 70° FPressure Drop Assisted, SolenoidNo-10 to 1802"3 1/2"NoNEMA 4X
    UL Listed, C-UL Listed
    47545K150000000
    3/8
    FemaleNPT
    4.4230 psi @ 70° FZero Pressure Drop, SolenoidNo-10 to 1802 15/16"3 11/16"NoNEMA 4X
    UL Listed, C-UL Listed
    47545K16000000
     