McMaster-Carr logo
    Filter by
    System of Measurement
    Valve Position
    Direction of Force
    Thread Type
    Frequency
    Actuation
    Rod Return Type
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    For Valve Manufacturer
    Force @ 10% Stroke Length
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Industrial Info Compare
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    72 Products

    Solenoid On/Off Valves

    These solenoid valves operate on electricity to automatically start and stop flow. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Fail Closed—120V AC/240V AC
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves, Bronze Body with Wire Lead Connection—Viton® Fluoroelastomer Seal.

    Bronze Body with Wire

    Lead Connection—Viton®

    Fluoroelastomer Seal

    Fail closed valves are closed unless actuated.
    Pressure Drop Assisted Valve—Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
    NEMA 4X Enclosure Rating—NEMA 4X valves withstand corrosive liquid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Enclosure Rating—All IP- or NEMA-rated valves stand up to dust and washdowns.
    Pipe
    Size
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Certification
    Each
    Bronze Body with Wire Lead Connection—Viton® Fluoroelastomer Seal
     
    NPT Female
    1/4
    2.1125 psi @ 220° FPressure Drop Assisted, Solenoid-15 to 2202 3/4"4 15/16"NEMA 4X
    UL Listed
    4635K1720000000
    3/8
    2.3125 psi @ 220° FPressure Drop Assisted, Solenoid-15 to 2202 3/4"4 15/16"NEMA 4X
    UL Listed
    4635K173000000
    1/2
    3.9125 psi @ 220° FPressure Drop Assisted, Solenoid-15 to 2202 3/4"4 15/16"NEMA 4X
    UL Listed
    4635K174000000
    3/4
    5.1125 psi @ 220° FPressure Drop Assisted, Solenoid-15 to 2203 1/4"5 1/4"NEMA 4X
    UL Listed
    4635K175000000
    1
    11.6125 psi @ 220° FPressure Drop Assisted, Solenoid-15 to 2203 13/16"5 11/16"NEMA 4X
    UL Listed
    4635K176000000
    1 1/4
    12.1125 psi @ 220° FPressure Drop Assisted, Solenoid-15 to 2204 1/4"6 5/16"NEMA 4X
    UL Listed
    4635K177000000
    1 1/2
    26125 psi @ 220° FPressure Drop Assisted, Solenoid-15 to 2204 7/8"6 15/16"NEMA 4X
    UL Listed
    4635K178000000
    2
    48125 psi @ 220° FPressure Drop Assisted, Solenoid-15 to 2205 7/8"7 9/16"NEMA 4X
    UL Listed
    4635K179000000
     
    Fail Closed—240V AC
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves, Brass Body with DIN A Connection—Buna-N Seal.
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves, Brass Body with DIN A Connection—Fluoroelastomer Seal.

    Brass Body with

    DIN A

    Connection—Buna-N

    Seal

    Brass Body with DIN A

    Connection—Fluoroelastomer

    Seal

    Fail closed valves are closed unless actuated.
    Zero Pressure Drop Valve—Zero pressure drop valves don’t require a minimum pressure drop between the inlet and outlet for operation.
    Pressure Drop Assisted Valve—Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Enclosure Rating—All IP- or NEMA-rated valves stand up to dust and washdowns.
    Valves
    Repair Kits
    Solenoid Coils
    Pipe
    Size
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Certification
    Each
    Each
    Each
    Brass Body with DIN A Connection—Buna-N Seal
     
    NPT Female
    1/4
    1.4200 psi @ 70° FZero Pressure Drop, Solenoid15 to 1952 1/4"3 1/2"IP65, NEMA 4
    CE Marked
    4711K51400000002875N160000002881N14000000
    1/4
    1.4300 psi @ 70° FPressure Drop Assisted, Solenoid15 to 1952"3 5/8"IP65, NEMA 4
    CE Marked
    4738K8090000002875N18000002881N1400000
    3/8
    1.4200 psi @ 70° FZero Pressure Drop, Solenoid15 to 1952 1/4"3 1/2"IP65, NEMA 4
    CE Marked
    4711K6250000002875N16000002881N1400000
    3/8
    1.8300 psi @ 70° FPressure Drop Assisted, Solenoid15 to 1952"3 5/8"IP65, NEMA 4
    CE Marked
    4738K8210000002875N18000002881N1400000
    1/2
    1.8300 psi @ 70° FPressure Drop Assisted, Solenoid15 to 1952 13/16"3 5/8"IP65, NEMA 4
    CE Marked
    4738K8220000002875N18000002881N1400000
    1/2
    2.8200 psi @ 70° FZero Pressure Drop, Solenoid15 to 1952 3/4"4"IP65, NEMA 4
    CE Marked
    4711K7350000004738K217000002881N1400000
    3/4
    2.8200 psi @ 70° FZero Pressure Drop, Solenoid15 to 1952 3/4"4"IP65, NEMA 4
    CE Marked
    4711K8450000004738K217000002881N1400000
    3/4
    9.8230 psi @ 70° FPressure Drop Assisted, Solenoid15 to 1954 1/16"4 1/8"IP65, NEMA 4
    CE Marked
    4738K8230000002875N19000002881N1400000
    1
    8.4115 psi @ 70° FZero Pressure Drop, Solenoid15 to 1954 1/16"4 1/4"IP65, NEMA 4
    CE Marked
    4711K9560000004738K221000002881N1400000
    1
    13230 psi @ 70° FPressure Drop Assisted, Solenoid15 to 1954 1/16"4 1/2"IP65, NEMA 4
    CE Marked
    4738K8240000002875N19000002881N1400000
    1 1/4
    28150 psi @ 70° FPressure Drop Assisted, Solenoid15 to 1955 5/8"5"IP65, NEMA 4
    CE Marked
    4738K8180000002875N210000002881N1400000
    1 1/2
    36150 psi @ 70° FPressure Drop Assisted, Solenoid15 to 1955 5/8"5"IP65, NEMA 4
    CE Marked
    4738K8160000002875N210000002881N1400000
    2
    53150 psi @ 70° FPressure Drop Assisted, Solenoid15 to 1956 3/4"5 9/16"IP65, NEMA 4
    CE Marked
    4738K8170000002875N220000002881N1400000
     
    Brass Body with DIN A Connection—Fluoroelastomer Seal
     
    NPT Female
    1 1/2
    19230 psi @ 280° FZero Pressure Drop, Solenoid15 to 2805 1/16"5 1/8"IP65, NEMA 4
    CE Marked
    4711K9580000002875N110000002881N1400000
     
    Fail Open—240V AC
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves, Brass Body with DIN B Connection—Buna-N Seal.

    Brass Body with

    DIN B

    Connection—Buna-N

    Seal

    Fail open valves are open unless actuated.
    Pressure Drop Assisted Valve—Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Enclosure Rating—All IP- or NEMA-rated valves stand up to dust and washdowns.
    Pipe
    Size
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Each
    Brass Body with DIN B Connection—Buna-N Seal
     
    NPT Female
    1/2
    2.46130 psi @ 140° FPressure Drop Assisted, Solenoid15 to 1952 5/8"3 1/8"IP65
    4738K7420000000
    3/4
    5.85130 psi @ 140° FPressure Drop Assisted, Solenoid15 to 1953 1/8"3 5/8"IP65
    4738K745000000
     

    High-Force Linear Solenoids

    High-force solenoids draw more power than our other open-frame solenoids, so they can deliver higher force. They also have a laminated rod that minimizes friction during operation.
    Intermittent Duty
    Image of Product. Pull Solenoid. Front orientation. Contains Annotated, MultipleImages. Solenoids. High-Force Linear Solenoids, Pull Force Direction.

    Pull Solenoid

    Pull Force Direction—Pull solenoids exert force when the rod retracts.
    Length
    Overall
    Max. Stroke
    Lg.
    Retracted
    Extended
    Force @ 50%
    Stroke Lg., ozf
    Force @ 100%
    Stroke Lg., ozf
    Direction
    of Operation
    Power Draw,
    W
    On/Off Time
    Wd.
    Ht.
    Lg.
    Rod Diameter
    (R)
    Certification
    Voltage,
    V AC
    Each
    For AC Voltage, 60 Hz
     
    Pull Force Direction
    1"2.7"3.4"195144Linear2283 Minutes On, 27 Minutes Off1 7/8"2 1/8"3.4"0.49"UL Recognized Component
    2407723K7000000
     
    Continuous Duty
    Image of Product. Pull Solenoid. Front orientation. Contains Annotated, MultipleImages. Solenoids. High-Force Linear Solenoids, Pull Force Direction.

    Pull Solenoid

    Pull Force Direction—Pull solenoids exert force when the rod retracts.
    Length
    Overall
    Max. Stroke
    Lg.
    Retracted
    Extended
    Force @ 50%
    Stroke Lg., ozf
    Force @ 100%
    Stroke Lg., ozf
    Direction
    of Operation
    Power Draw,
    W
    Wd.
    Ht.
    Lg.
    Rod Diameter
    (R)
    Certification
    Voltage,
    V AC
    Each
    For AC Voltage, 60 Hz
     
    Pull Force Direction
    1"2.7"3.4"10560Linear491 7/8"2 1/8"3.4"0.49"UL Recognized Component
    2407723K8000000
     

    Solenoid Coils for Flow-Control Valves

    Image of Product. Front orientation. Solenoid Coils. Solenoid Coils for Flow-Control Valves, For ASCO Valves.

    For ASCO Valves

    Image of Product. Front orientation. Solenoid Coils. Solenoid Coils for Flow-Control Valves, For Granzow Valves.

    For Granzow Valves

    Image of Product. Front orientation. Solenoid Coils. Solenoid Coils for Flow-Control Valves, For Parker Valves.

    For Parker Valves

    Coils are original manufacturer replacements for Parker, GC, ASCO, Granzow, Magnatrol and Fairchild valves. Match your valve’s part number to the compatible solenoid coil.
    For Valve Mfr. Model No.
    Coil
    Material
    Each
    ASCO 8040 Series
     
    240V AC
    8040C004-240V-AC, 8040C005-240V-ACCopper2835N1030000000
     
    ASCO 8210 Series
     
    240V AC
    8210G001-240V-AC, 8210G002-240V-AC, 8210G004-240V-AC, 8210G009-240V-ACCopper2863N6000000
    8210G054-240V-AC, 8210G056-240V-ACCopper2863N5000000
    8210G093-240V-AC, 8210G094-240V-AC, 8210G095-240V-ACCopper2863N4000000
     
    Granzow E, H, W
     
    240V AC
    E2B59-000, E3B59-000, E4B59-000, H2B59-00Y, H3B59-00Y, H4B59-00Y, H5B59-00Y, H6B59-00Y, H8B59-00V, W5B59-000, W6B59-000, W7B59-000, W8B59-000, W9B59-000Copper2881N1400000
     
    Parker Gold Ring Series
     
    240V AC
    06F22C2140AAF4C15Brass2894N1700000
    06F23C2140ACF4C15Brass2894N1300000
     

    Two-Speed Two-Action Electrically Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style C.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style J.

    Style C

    Style J

    Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as 4-way and 5/2 valves, they actuate when voltage is applied to the electrical connection. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion.
    Threaded Female Inlet × Threaded Female Outlet—Threaded Exhaust
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style C.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style J.

    Style C

    Style J

    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Valves
    Replacement
    Solenoids
    Overall
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Voltage,
    V AC
    Each
    Each
    Single Solenoid—Spring Return
    C51/4 NPT1/4 NPT56140 to 120Not Rated4 3/8"1 7/8"3 3/8"Screw In2406196K23100000006196K1000000
     
    Double Solenoid—Solenoid Return
    J51/4 NPT1/4 NPT56140 to 120Not Rated5 7/8"1 7/8"3 3/8"Screw In2406196K24000000———0
     

    Premium Solenoid On/Off Valves

    Image of Product. Front orientation. Solenoid On/Off Valves. Premium Solenoid On/Off Valves.
    Image of Specification. Front orientation. Contains Annotated. Premium Solenoid On/Off Valves.
    These top-of-the-line valves are comparable to Asco Red Hat 8210G Series and Parker Gold Ring 23C Series. They operate on electricity to automatically start and stop flow. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Fail-Closed Valve—Fail closed valves are closed unless actuated.
    Zero Pressure Drop Valve—Zero pressure drop valves don’t require a minimum pressure drop between the inlet and outlet for operation.
    Pressure Drop Assisted Valve—Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valves
    Repair Kits
    Solenoid Coils
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Manual
    Override
    Temp. Range,
    ° F
    Seal
    Material
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Certification
    Each
    Each
    Each
    Brass Body with Wire Lead Connection
     
    Fail Closed—240V AC
    3/8
    FemaleNPT
    3150 psi @ 180° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    2 3/4"3 13/16"NEMA 4X
    UL Listed, CSA Certified
    2660K1300000002660K40100000002863N40000000
    3/8
    FemaleNPT
    3150 psi @ 180° FPressure Drop Assisted, SolenoidNo35 to 180Buna-N
    2 3/4"3 3/8"NEMA 4X
    UL Listed, CSA Certified
    2663K130000002663K5770000002863N6000000
    1/2
    FemaleNPT
    4150 psi @ 180° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    2 3/4"3 13/16"NEMA 4X
    UL Listed, CSA Certified
    2660K230000002660K4010000002863N4000000
    1/2
    FemaleNPT
    4150 psi @ 180° FPressure Drop Assisted, SolenoidNo35 to 180Buna-N
    2 3/4"3 3/8"NEMA 4X
    UL Listed, CSA Certified
    2663K230000002663K5770000002863N6000000
    3/4
    FemaleNPT
    5150 psi @ 180° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    2 13/16"4 1/8"NEMA 4X
    UL Listed, CSA Certified
    2660K330000002660K5750000002863N4000000
    3/4
    FemaleNPT
    5125 psi @ 180° FPressure Drop Assisted, SolenoidNo35 to 180Buna-N
    2 13/16"3 11/16"NEMA 4X
    UL Listed, CSA Certified
    2663K330000002663K6720000002863N6000000
    1
    FemaleNPT
    13150 psi @ 180° FPressure Drop Assisted, SolenoidNo35 to 180Buna-N
    3 3/4"5 5/8"NEMA 4X
    UL Listed, CSA Certified
    2663K430000002663K6780000002863N6000000
    1
    FemaleNPT
    13125 psi @ 180° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    3 3/4"5 1/8"CSA Certified
    2660K380000002660K5930000002863N5000000
    1 1/2
    FemaleNPT
    22.5125 psi @ 180° FZero Pressure Drop, SolenoidNo35 to 180Buna-N
    4 5/8"5 7/8"CSA Certified
    2660K390000002660K5960000002863N5000000
    2
    FemaleNPT
    43125 psi @ 180° FPressure Drop Assisted, SolenoidNo35 to 180Buna-N
    5 1/16"7 5/16"CSA Certified
    2660K410000002660K60000002863N6000000
     

    Solenoid On/Off Valves for Natural Gas, Propane, and Butane

    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Natural Gas, Propane, and Butane.
    Install these valves in gas pipelines to control the flow of natural gas, propane, and butane to equipment. They operate on electricity to automatically start and stop flow.
    Valves are fail closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Valves
    Repair Kits
    Solenoid Coils
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Seal
    Material
    Valve
    Lg.
    Overall
    Ht.
    Fasteners
    Included
    Enclosure
    Rating
    Certification
    Each
    Each
    Each
    Aluminum Body with Wire Lead Connection
     
    Fail Closed—240V AC
    1/2
    FemaleNPT
    5.42 psi @ 125° FZero Pressure Drop, Solenoid-40 to 125Buna-N
    2 3/4"4"NoNEMA 4X
    UL Listed, CSA Certified, FM Approved
    4689K84400000002660K11200000002863N40000000
    1
    FemaleNPT
    16.80.5 psi @ 125° FZero Pressure Drop, Solenoid-40 to 125Buna-N
    5"6 13/16"NoNEMA 4X
    UL Listed, CSA Certified
    4689K8460000002660K1110000002835N103000000
     

    Timer-Actuated Compressed Air Drain Valves

    Image of Product. Front orientation. Drain Valves. Timer-Actuated Compressed Air Drain Valves, Brass Housing—NEMA 4X Enclosure Rating.

    Brass Housing—NEMA 4X

    Enclosure Rating

    Set the electronic timer on these drain valves to open automatically at your specified time interval. They’re excellent for compressed air systems with high oil content because they resist clogging when water, oil, and sediment combine to form sludge. Install drain valves after separators, dryers, filters, and aftercoolers to collect and remove water from your air line.
    NEMA 4X Enclosure Rating—Drain valves that meet NEMA 4X are rated for protection from dirt, washdowns, and corrosion.
    Inlet
    Outlet
    Overall
    Pipe
    Size
    Thread
    Type
    Gender
    Connection
    Pipe
    Size
    Thread
    Type
    Gender
    Discharge
    Cap., gpm
    Max. Pressure,
    psi
    Ht.
    Wd.
    Dp.
    Cycle Interval
    Time, min.
    Drain Time,
    sec.
    Max. Temp.,
    ° F
    Includes
    Each
    Brass Housing—NEMA 4X Enclosure Rating
     
    Electric, 240V AC—Hardwire
    1/4
    NPT
    FemaleThreaded1/4
    NPT
    Female2.92004 1/8"6"3 3/4"0 to 501 to 15180Strainer9831K220000000
     
    Replacement Filter Mesh

    Single-Action Electrically Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style G.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style H.

    Style G

    Style H

    These valves create one action, such as extending a cylinder. Apply voltage to the electrical connection to actuate. Also known as 3-way and 3/2 valves, they direct airflow from the inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air from the system, allowing equipment to reset so the action can be repeated. Valves without an exhaust connection exhaust air to the atmosphere.
    Threaded Female Inlet × Threaded Female Outlet: Fail-Closed Valve
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style G.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style H.

    Style G

    Style H

    Fail-closed valves block airflow until actuated.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Voltage,
    V AC
    Each
    Single Solenoid—Spring Return
    G31/8 NPT1/8 NPT1.970.0350 to 1201 7/8"1 1/4"2 3/8"Screw In24061245K830000000
    H31/8 NPT1/8 NPTThreaded1.970.0350 to 1201 7/8"1 1/4"2 3/4"Screw In24061245K85000000
     

    Solenoid On/Off Valves with Easy-Access Strainer for Detergent

    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves with Easy-Access Strainer for Detergent.
    A built-in strainer traps debris and allows you to replace the screen without disconnecting your pipeline. These valves operate on electricity to automatically start and stop flow.
    All valves are fail closed unless actuated. They require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Valve Type
    Manual
    Override
    Temp. Range,
    ° F
    Seal
    Material
    Valve
    Lg.
    Overall
    Ht.
    Mesh
    Size
    Quick-Disconnect
    Tab Wd.
    Each
    Brass Body with Quick-Disconnect-Terminal Wire Connection
     
    Fail Closed—240V AC
    1/4
    FemaleNPT
    1125 psi @ 180° FPressure Drop Assisted, SolenoidNo35 to 180EPDM
    2 3/8"3 3/4"60 × 60
    1/4"4590K16000000
    3/8
    FemaleNPT
    1125 psi @ 180° FPressure Drop Assisted, SolenoidNo35 to 180EPDM
    2 3/8"3 3/4"60 × 60
    1/4"4590K2600000
     
    back to top