Steam Condensate Pumps with Tank
Designed for use in low-pressure steam systems, these pumps capture steam in the attached tank and return hot condensate to your boiler or feed unit. They are activated by a float switch, turning on and off when condensate level reaches a certain depth.
Pumps with cast iron tank are for continuous use and have a longer service life than carbon steel.
Maintenance kit for pump with cast iron tank includes a shaft, a bushing, a thrust washer, a spring washer, an oil seal, and snap rings.
Max. Flow Rate, gpm | Level | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | Tank Cap., gal. | @ 1 Ft. of Head | @ 10 Ft. of Head | @ 35 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Pipe Size | Discharge Pipe Size | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Hardwire | 8 | 44 | 41 | 26 | 46 | 20 | 7" | 4 1/2" | 35° to 250° | 1/3 hp | 5.6 | 2 NPT Female | 3/4 NPT Female | 12 1/2" | 12 1/2" | 21 1/2" | 00000000 | 000000000 |
Hardwire | 15 | 44 | 41 | 26 | 46 | 20 | 9" | 4 1/2" | 35° to 250° | 1/3 hp | 5.6 | 2 NPT Female | 3/4 NPT Female | 14 3/8" | 17" | 23 1/4" | 00000000 | 00000000 |
Max. Flow Rate, gpm | Level | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | Tank Cap., gal. | @ 35 Ft. of Head | @ 50 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Pipe Size | Discharge Pipe Size | Ht. | Wd. | Dp. | Each | |
120V AC/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | 8 | 6.5 | 5.8 | 69 | 30 | 7 1/4" | 5 1/4" | 160° to 200° | 1/4 hp | 2.5/5 | 2 NPT Female | 1 NPT Female | 26" | 17" | 17" | 0000000 | 000000000 |
Hardwire | 8 | 13 | __ | 46 | 20 | 7 1/4" | 5 1/4" | 160° to 200° | 1/3 hp | 3.2/6 | 2 NPT Female | 1 NPT Female | 26" | 17" | 17" | 0000000 | 00000000 |
Maintenance Kit | 0000000 | Each | 0000000 |
Corrosion-Resistant Steam Condensate Pump with Tank
The stainless steel tank has excellent corrosion resistance. Designed for use in low-pressure steam systems, these pumps capture steam in the attached tank and return hot condensate to your boiler or feed unit. They are activated by a float switch, turning on and off when condensate level reaches a certain depth.
Max. Flow Rate, gpm | Level | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Tank Cap., gal. | @ 1 Ft. of Head | @ 10 Ft. of Head | @ 35 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Pipe Size | Discharge Pipe Size | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
8 | 44 | 41 | 26 | 46 | 20 | 7" | 4 1/2" | 35° to 250° | 1/3 hp | 5.6 | 2 NPT Female | 3/4 NPT Female | 12 1/2" | 12 1/2" | 21 1/2" | 00000000 | 000000000 |
15 | 44 | 41 | 26 | 46 | 20 | 9" | 4 1/2" | 35° to 250° | 1/3 hp | 5.6 | 2 NPT Female | 3/4 NPT Female | 14 3/8" | 17" | 23 1/4" | 00000000 | 00000000 |
Extended-Life Steam Condensate Pumps with Tank
To handle high condensate volume, the workload is distributed between two pumps for a longer service life than standard steam condensate pumps. The second pump provides redundancy so one pump can operate while you work on the other. Use in low-pressure steam systems to capture hot condensate and return it to your boiler or feed unit. Pumps turn on and off when condensate level reaches a certain depth.
Maintenance kit includes a shaft, a bushing, a thrust washer, a spring washer, an oil seal, and snap rings. Purchase two kits to repair this pump.
Max. Flow Rate, gpm | Level | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Tank Cap., gal. | @ 35 Ft. of Head | @ 50 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Pipe Size | Discharge Pipe Size | Ht. | Wd. | Dp. | Each | |
120V AC/240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
15 | 13 | 12 | 46 | 20 | 6 1/2", 7 1/2" | 4 1/4", 5 1/4" | 160° to 200° | 1/3 hp | 3.2/6 | 2 NPT Female | 1 NPT Female | 24" | 22 1/2" | 22 1/2" | 0000000 | 000000000 |
Maintenance Kit | 0000000 | Each | 0000000 |
Extended-Life High-Flow Steam Condensate Pumps with Tank
To handle high condensate volume, the workload is distributed between two pumps for a longer service life than standard high-flow steam condensate pumps. The second pump provides redundancy so one pump can operate while you work on the other. These pumps move a higher volume of condensate than standard steam condensate pumps. Use them in low-pressure steam systems to capture hot condensate and return it to your boiler or feed unit. Pumps turn on when the tank is 2/3 full and turn off when condensate drops to 6" deep.
Max. Flow Rate, gpm | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Tank Cap., gal. | @ 35 Ft. of Head | @ 50 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn-Off Level | Temp. Range, °F | Horsepower | Current, A | Intake Pipe Size | Discharge Pipe Size | Ht. | Wd. | Dp. | Each | |
120V AC/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||
Hardwire | |||||||||||||||
15 | 35 | 25 | 71 | 25 | 6" | 35° to 210° | 1/3 hp | 4.4/8.8 | 2 NPT Female | 1 NPT Female | 20" | 18" | 27" | 0000000 | 000000000 |
20 | 35 | 25 | 71 | 25 | 6" | 35° to 210° | 1/3 hp | 4.4/8.8 | 2 NPT Female | 1 NPT Female | 21" | 25" | 25" | 0000000 | 00000000 |
High-Flow Steam Condensate Pumps with Tank
Move a higher volume of condensate than standard steam condensate pumps. Use these pumps in low-pressure steam systems to capture hot condensate and return it to your boiler or feed unit. They turn on when the tank is 2/3 full and turn off when condensate drops to 6" deep.
Max. Flow Rate, gpm | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Tank Cap., gal. | @ 35 Ft. of Head | @ 50 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn-Off Level | Temp. Range, °F | Horsepower | Current, A | Intake Pipe Size | Discharge Pipe Size | Ht. | Wd. | Dp. | Each | |
120V AC/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||
Hardwire | |||||||||||||||
6 | 35 | 25 | 71 | 25 | 6" | 30° to 210° | 1/3 hp | 4.4/8.8 | 2 NPT Female | 1 NPT Female | 13" | 15" | 26" | 0000000 | 000000000 |
15 | 35 | 25 | 71 | 25 | 6" | 30° to 210° | 1/3 hp | 4.4/8.8 | 2 NPT Female | 1 NPT Female | 20" | 18" | 27" | 0000000 | 00000000 |
20 | 35 | 25 | 71 | 25 | 6" | 30° to 210° | 1/3 hp | 4.4/8.8 | 2 NPT Female | 1 NPT Female | 19" | 25" | 25" | 0000000 | 00000000 |
Maintenance Seal Kit | 0000000 | Each | 0000000 |
Replacement Float Switch for Pumps with 15 gal. and 20 gal. Tank Cap. | 0000000 | Each | 000000 |
Replacement Impeller | 0000000 | Each | 000000 |
Replacement Tank Gasket | 0000000 | Each | 00000 |
Replacement Pump and Motor Assembly Kit | 0000000 | Each | 00000000 |
Replacement Vent Pipe Assembly | 0000000 | Each | 00000 |
Replacement Float Switch for Pumps with 6 gal. Tank Cap. | 0000000 | Each | 000000 |
Steam Condensate Pumps
Use these pumps in low-pressure steam systems to capture hot condensate and return it to your boiler or feed unit. Wire your own pump activation switch.
Max. Flow Rate, gpm | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 35 Ft. of Head | @ 50 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Temp. Range, °F | Horsepower | Current, A | Intake Pipe Connection Type | Pipe Size | Discharge Pipe Size | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||
Hardwire | ||||||||||||||
38 | 3 | 50 | 20 | 35° to 212° | 1/2 hp | 8.2 | Flanged | 2 3/4 | 1 1/2 NPT Female | 16" | 7 3/8" | 10 3/4" | 00000000 | 000000000 |
50 | 23 | 58 | 20 | 35° to 212° | 3/4 hp | 8.2 | Flanged | 2 3/4 | 1 1/2 NPT Female | 16 3/4" | 7 3/8" | 10 3/4" | 00000000 | 00000000 |
Boiler Feed Pumps
Keep the water in your boiler at the proper level by pumping in condensate. Wire one of these pumps to the boiler’s controller and the float switch activates the pump to fill when water level gets too low. A safety valve connects to your facility’s water line to ensure the pump won’t run dry.
Max. Flow Rate, gpm | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Tank Cap., gal. | @ 1 Ft. of Head | @ 10 Ft. of Head | @ 35 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Temp. Range, °F | Horsepower | Current, A | Intake Pipe Size | Discharge Pipe Size | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||
Hardwire | |||||||||||||||
15 | 44 | 41 | 26 | 46 | 20 | 35° to 250° | 1/3 hp | 5.6 | 2 1/2 NPT Female | 3/4 NPT Female | 18 3/8" | 22" | 28" | 00000000 | 000000000 |
30 | 44 | 41 | 26 | 46 | 20 | 35° to 250° | 1/3 hp | 5.6 | 2 1/2 NPT Female | 3/4 NPT Female | 18 3/8" | 22" | 28" | 00000000 | 00000000 |
Condensate Pumps with Tank
Equipped with a built-in container for condensate, these pumps work alongside your system to remove condensate from air conditioners, refrigerators, dehumidifiers, and other equipment. They are not submersible. A safety switch turns off your equipment in case of pump failure. Pumps turn on and off automatically.
Hardwire pumps must be wired to a power source.
Style A pumps have a two-piece body so you can install them up to 3 ft. away from the condensate reservoir.
Style B pumps have a low profile for use in areas with limited clearance.
Style C pumps are often used with medium tonnage air conditioning and refrigerating units.
Style D pumps withstand higher temperatures than the other styles.
Style E pumps handle heavy condensate accumulation.
Style F pumps move condensate to greater heights than the other styles.
Max. Flow Rate, gpm | Level | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Electrical Connection Type | Tank Capacity, oz. | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Discharge Pipe Size | Ht. | Wd. | Dp. | Each | |
120V AC/240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
A | Hardwire | 0.7 | 0.04 | 0.03 | 0.03 | 33 | 26 | 9/16" | 0.38" | 35° to 140° | Not Rated | 0.1/0.2 | 1/4 NPT Male | 2 3/8" | 1 7/8" | 4 1/8" | 0000000 | 0000000 |
Max. Flow Rate, gpm | Level | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Electrical Connection Type | Tank Capacity, gal. | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Tube Connection Type | For Tube ID | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
B | Plug | 0.3 | 1.3 | 1.1 | 0.8 | 20 | 9 | 1" | 1/2" | 35° to 120° | 1/30 hp | 1.5 | Barbed | 3/8" | 5" | 5" | 12" | 00000000 | 0000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
B | Hardwire | 0.3 | 1.3 | 1.1 | 0.8 | 14 | 7 | 1" | 1/2" | 35° to 120° | 1/30 hp | 0.5 | Barbed | 3/8" | 5" | 5" | 12" | 00000000 | 000000 |
Max. Flow Rate, gpm | Level | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Electrical Connection Type | Tank Capacity, gal. | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Tube Connection Type | For Tube ID | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
C | Plug | 0.5 | 1.3 | 1.1 | 0.8 | 20 | 9 | 2 1/4" | 1 1/4" | 35° to 120° | 1/30 hp | 1.5 | Barbed | 3/8" | 7" | 5" | 11" | 00000000 | 0000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
C | Hardwire | 0.5 | 1.3 | 1.1 | 0.8 | 17 | 7 | 2 1/4" | 1 1/4" | 35° to 120° | 1/30 hp | 0.5 | Barbed | 3/8" | 7" | 5" | 11" | 00000000 | 000000 |
Max. Flow Rate, gpm | Level | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Electrical Connection Type | Tank Capacity, gal. | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Tube Connection Type | For Tube OD | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
D | Hardwire | 1 | 1.8 | 1.6 | 1.4 | 25 | 11 | 3 3/16" | 7/8" | 35° to 190° | 1/20 hp | 1.3 | Compression | 3/8" | 10 1/8" | 6" | 12" | 0000000 | 0000000 |
D | Hardwire | 1 | 7.9 | 7.3 | 6.6 | 50 | 22 | 3 3/16" | 7/8" | 35° to 210° | 1/4 hp | 4 | Compression | 1/2" | 10 1/8" | 6" | 12" | 0000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
D | Hardwire | 1 | 1.8 | 1.6 | 1.4 | 25 | 11 | 3 3/16" | 7/8" | 35° to 190° | 1/20 hp | 0.9 | Compression | 3/8" | 10 1/8" | 6" | 12" | 0000000 | 000000 |
D | Hardwire | 1 | 8.1 | 7.5 | 6.8 | 50 | 22 | 3 3/16" | 7/8" | 35° to 210° | 1/5 hp | 1 | Compression | 1/2" | 10 1/8" | 6" | 12" | 0000000 | 000000 |
Max. Flow Rate, gpm | Level | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Electrical Connection Type | Tank Capacity, gal. | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Tube Connection Type | For Tube ID | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
E | Plug | 1 | 4.5 | 4.1 | 3.5 | 24 | 10 | 3 1/2" | 2" | 35° to 120° | 1/18 hp | 2.5 | Barbed | 3/8" | 10 5/8" | 6" | 12" | 00000000 | 0000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
E | Hardwire | 1 | 4.5 | 4.1 | 3.5 | 24 | 10 | 3 1/2" | 2" | 35° to 120° | 1/18 hp | 1.2 | Barbed | 3/8" | 10 1/2" | 6" | 12" | 00000000 | 000000 |
Max. Flow Rate, gpm | Level | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Electrical Connection Type | Tank Capacity, gal. | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Tube Connection Type | For Tube OD | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
F | Plug | 1 | 7.5 | 7.3 | 6.8 | 45 | 20 | 3 1/2" | 2" | 35° to 120° | 1/5 hp | 3.5 | Compression | 3/8" | 10 1/2" | 6" | 12" | 00000000 | 0000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
F | Hardwire | 1 | 7.5 | 7.3 | 6.8 | 45 | 20 | 3 1/2" | 2" | 35° to 120° | 1/5 hp | 1 | Compression | 3/8" | 10 1/2" | 6" | 12" | 00000000 | 000000 |
Condensate Pumps
Fully submersible, these pumps are designed for installation inside your condensate collection tank or drain pan. Use them to collect and remove condensate from air conditioners, refrigerators, dehumidifiers, and other equipment. They turn on and off automatically.
Max. Flow Rate, gpm | Level | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Discharge Pipe Size | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||
Plug | |||||||||||||||
3.4 | 2.4 | 10 | 4 | 1 3/4" | 1 1/4" | 35° to 120° | 1/150 hp | 1.1 | Screened | 1/4 NPT Male | 4 3/8" | 6 3/8" | 6 1/8" | 0000000 | 0000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||
Hardwire | |||||||||||||||
3.4 | 2.4 | 10 | 4 | 1 3/4" | 1 1/4" | 35° to 120° | 1/150 hp | 0.5 | Screened | 1/4 NPT Male | 4 3/8" | 6 3/8" | 6 1/8" | 0000000 | 000000 |