    About Actuated On/Off Valves
    industrial info icon

    Choose the right automatic on/off valve based on power source, pressure, and flow rate.

    Solenoid On/Off Valves for Steam

    These valves are designed to withstand the high temperatures and pressures in steam service applications. They operate on electricity to automatically start and stop flow. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
    Brass Body with Wire Lead Connection—EPDM Seal
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Steam, Brass Body with Wire Lead Connection—EPDM Seal.
    Fail-Closed Valve—Fail closed valves are closed unless actuated.
    Pressure Drop Assisted Valve—Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Steam Pressure
    @ Temp.
    Valve Type
    Temp.,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Certification
    Each
    Fail Closed—24V AC
    1 1/2
    FemaleNPT
    2350 psi @ 300° FPressure Drop Assisted, Solenoid35 to 2104 3/8"6 5/16"NEMA 3S, NEMA 4X
    UL Listed, CSA Certified
    47905K830000000
    2
    FemaleNPT
    4350 psi @ 300° FPressure Drop Assisted, Solenoid35 to 2105 1/16"7 1/2"NEMA 3S, NEMA 4X
    UL Listed, CSA Certified
    47905K8400000000
     
    Fail Closed—120V AC
    1 1/2
    FemaleNPT
    2350 psi @ 300° FPressure Drop Assisted, Solenoid35 to 2104 3/8"6 5/16"NEMA 3S, NEMA 4X
    UL Listed, CSA Certified
    47905K76000000
    2
    FemaleNPT
    4350 psi @ 300° FPressure Drop Assisted, Solenoid35 to 2105 1/16"7 1/2"NEMA 3S, NEMA 4X
    UL Listed, CSA Certified
    47905K7700000000
     
    Brass Body with Wire Lead Connection—PTFE Seal
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Steam, Brass Body with Wire Lead Connection—PTFE Seal.
    Fail-Closed Valve—Fail closed valves are closed unless actuated.
    Fail-Open Valve—Fail open valves are open unless actuated.
    Zero Pressure Drop Valve—Zero pressure drop valves don’t require a minimum pressure drop between the inlet and outlet for operation.
    Pressure Drop Assisted Valve—Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valves
    Repair Kits
    Solenoid Coils
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Steam Pressure
    @ Temp.
    Valve Type
    Temp.,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Certification
    Flammability
    Rating
    Each
    Each
    Each
    Fail Closed—24V AC
    3/8
    FemaleNPT
    3125 psi @ 350° FPressure Drop Assisted, Solenoid35 to 3502 17/32"3 13/16"NEMA 4X
    UL Listed, CSA Certified
    47905K6200000002895N220000002894N220000000
    3/8
    FemaleNPT
    450 psi @ 300° FZero Pressure Drop, Solenoid35 to 2102 7/8"4 1/8"NEMA 3S, NEMA 4X
    UL Listed, CSA Certified
    47905K78000000———0———0
    1/2
    FemaleNPT
    4125 psi @ 350° FPressure Drop Assisted, Solenoid35 to 3502 17/32"3 13/16"NEMA 4X
    UL Listed, CSA Certified
    47905K640000002895N270000002894N22000000
    1/2
    FemaleNPT
    550 psi @ 300° FZero Pressure Drop, Solenoid35 to 2102 7/8"4 1/8"NEMA 3S, NEMA 4X
    UL Listed, CSA Certified
    47905K79000000———0———0
    3/4
    FemaleNPT
    7125 psi @ 350° FPressure Drop Assisted, Solenoid35 to 3503 1/8"4 1/8"NEMA 4X
    UL Listed, CSA Certified
    47905K660000002895N330000002894N22000000
    3/4
    FemaleNPT
    950 psi @ 300° FZero Pressure Drop, Solenoid35 to 2102 7/8"4 3/16"NEMA 3S, NEMA 4X
    UL Listed, CSA Certified
    47905K81000000———0———0
    1
    FemaleNPT
    1250 psi @ 300° FPressure Drop Assisted, Solenoid35 to 2103 3/4"5 13/16"NEMA 3S, NEMA 4X
    UL Listed, CSA Certified
    47905K82000000———0———0
    1
    FemaleNPT
    12125 psi @ 350° FPressure Drop Assisted, Solenoid35 to 3504 7/16"4 5/8"NEMA 4X
    UL Listed, CSA Certified
    47905K680000002895N360000002894N22000000
    1
    FemaleNPT
    13150 psi @ 365° FPressure Drop Assisted, Solenoid35 to 3655 3/8"4 15/16"NEMA 4X
    UL Listed, CSA Certified
    UL 94 HB
    49225K71000000———04868K1800000
     
    Fail Closed—120V AC
    3/8
    FemaleNPT
    3125 psi @ 350° FPressure Drop Assisted, Solenoid35 to 3502 17/32"3 13/16"NEMA 4X
    UL Listed, CSA Certified
    47905K610000002895N210000002894N21000000
    3/8
    FemaleNPT
    450 psi @ 300° FZero Pressure Drop, Solenoid35 to 2102 7/8"4 1/8"NEMA 3S, NEMA 4X
    UL Listed, CSA Certified
    47905K72000000———0———0
    1/2
    FemaleNPT
    4125 psi @ 350° FPressure Drop Assisted, Solenoid35 to 3502 17/32"3 13/16"NEMA 4X
    UL Listed, CSA Certified
    47905K630000002895N270000002894N21000000
    1/2
    FemaleNPT
    550 psi @ 300° FZero Pressure Drop, Solenoid35 to 2102 7/8"4 1/8"NEMA 3S, NEMA 4X
    UL Listed, CSA Certified
    47905K73000000———0———0
    3/4
    FemaleNPT
    7125 psi @ 350° FPressure Drop Assisted, Solenoid35 to 3503 1/8"4 1/8"NEMA 4X
    UL Listed, CSA Certified
    47905K650000002895N330000002894N21000000
    3/4
    FemaleNPT
    950 psi @ 300° FZero Pressure Drop, Solenoid35 to 2102 7/8"4 3/16"NEMA 3S, NEMA 4X
    UL Listed, CSA Certified
    47905K74000000———0———0
    1
    FemaleNPT
    1250 psi @ 300° FPressure Drop Assisted, Solenoid35 to 2103 3/4"5 13/16"NEMA 3S, NEMA 4X
    UL Listed, CSA Certified
    47905K71000000———0———0
    1
    FemaleNPT
    12125 psi @ 350° FPressure Drop Assisted, Solenoid35 to 3504 7/16"4 5/8"NEMA 4X
    UL Listed, CSA Certified
    47905K670000002895N370000002894N21000000
    1
    FemaleNPT
    13150 psi @ 365° FPressure Drop Assisted, Solenoid35 to 3655 3/8"4 15/16"NEMA 4X
    UL Listed, CSA Certified
    UL 94 HB
    49225K76000000———04868K1700000
     
    Fail Open—24V AC
    3/4
    FemaleNPT
    7150 psi @ 365° FPressure Drop Assisted, Solenoid35 to 3653 13/16"4 5/8"NEMA 4X
    UL Listed, CSA Certified
    UL 94 HB
    49225K74000000———04868K1700000
     
    Fail Open—120V AC
    3/4
    FemaleNPT
    6150 psi @ 365° FPressure Drop Assisted, Solenoid35 to 3653 13/16"4 1/2"NEMA 4X
    UL Listed, CSA Certified
    UL 94 HB
    49225K83000000———0———0
     
    Bronze Body with Wire Lead Connection—Glass-Filled PTFE Seal
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Steam, Bronze Body with Wire Lead Connection—Glass-Filled PTFE Seal.
    Fail-Closed Valve—Fail closed valves are closed unless actuated.
    Zero Pressure Drop Valve—Zero pressure drop valves don’t require a minimum pressure drop between the inlet and outlet for operation.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Valves
    Repair Kits
    Solenoid Coils
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Steam Pressure
    @ Temp.
    Valve Type
    Temp., ° F
    Valve
    Lg.
    Overall
    Ht.
    Each
    Each
    Each
    Fail Closed—120V AC
    1/2
    FemaleNPT
    490 psi @ 400° FZero Pressure Drop, Solenoid-350 to 4003 1/4"7"7841K3500000002890N2600000002885N130000000
    1/2
    FemaleNPT
    4140 psi @ 400° FZero Pressure Drop, Solenoid-350 to 4003 1/4"7"7841K370000002890N130000002885N11000000
    1/2
    FemaleNPT
    4180 psi @ 400° FZero Pressure Drop, Solenoid-350 to 4003 1/4"8"7841K110000002890N190000002885N12000000
    3/4
    FemaleNPT
    850 psi @ 400° FZero Pressure Drop, Solenoid-350 to 4003 1/2"7 3/8"7841K420000002890N270000002885N13000000
    3/4
    FemaleNPT
    8110 psi @ 400° FZero Pressure Drop, Solenoid-350 to 4003 1/2"7 3/8"7841K460000002890N140000002885N11000000
    3/4
    FemaleNPT
    8180 psi @ 400° FZero Pressure Drop, Solenoid-350 to 4003 1/2"8 1/4"7841K120000002890N20000002885N12000000
    1
    FemaleNPT
    1350 psi @ 400° FZero Pressure Drop, Solenoid-350 to 4004 1/8"8"7841K520000002890N150000002885N11000000
    1
    FemaleNPT
    1390 psi @ 400° FZero Pressure Drop, Solenoid-350 to 4004 1/8"8"7841K550000002890N160000002885N11000000
    1
    FemaleNPT
    13180 psi @ 400° FZero Pressure Drop, Solenoid-350 to 4004 1/8"9"7841K130000002890N210000002885N12000000
    1 1/4
    FemaleNPT
    17140 psi @ 400° FZero Pressure Drop, Solenoid-350 to 4004 7/16"9 7/16"7841K140000002890N220000002885N12000000
    1 1/2
    FemaleNPT
    2590 psi @ 400° FZero Pressure Drop, Solenoid-350 to 4004 7/8"10"7841K75000000002890N230000002885N12000000
    1 1/2
    FemaleNPT
    25180 psi @ 400° FZero Pressure Drop, Solenoid-350 to 4004 7/8"11"7841K78000000002890N240000002885N14000000
    2
    FemaleNPT
    48115 psi @ 400° FZero Pressure Drop, Solenoid-350 to 4006"12 1/16"7841K86000000002890N480000002885N14000000
    2
    FemaleNPT
    48180 psi @ 400° FZero Pressure Drop, Solenoid-350 to 4006"12 1/16"7841K88000000002890N250000002885N14000000
     
    Bronze Body with Wire Lead Connection—PTFE Seal
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Steam, Bronze Body with Wire Lead Connection—PTFE Seal.
    Fail-Closed Valve—Fail closed valves are closed unless actuated.
    Pressure Drop Assisted Valve—Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Steam Pressure
    @ Temp.
    Valve Type
    Temp.,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Certification
    Each
    Fail Closed—120V AC
    1/4
    FemaleNPT
    2125 psi @ 355° FPressure Drop Assisted, Solenoid-40 to 3552 3/4"4 15/16"NEMA 4X
    UL Listed
    9766K910000000
    3/8
    FemaleNPT
    2125 psi @ 355° FPressure Drop Assisted, Solenoid-40 to 3552 3/4"4 15/16"NEMA 4X
    UL Listed
    9766K92000000
    1/2
    FemaleNPT
    4125 psi @ 355° FPressure Drop Assisted, Solenoid-40 to 3552 3/4"4 15/16"NEMA 4X
    UL Listed
    9766K93000000
    3/4
    FemaleNPT
    5125 psi @ 355° FPressure Drop Assisted, Solenoid-40 to 3553 1/4"5 5/16"NEMA 4X
    UL Listed
    9766K94000000
    1
    FemaleNPT
    12125 psi @ 355° FPressure Drop Assisted, Solenoid-40 to 3553 13/16"5 11/16"NEMA 4X
    UL Listed
    9766K95000000
    1 1/4
    FemaleNPT
    12125 psi @ 355° FPressure Drop Assisted, Solenoid-40 to 3554 1/4"6 5/16"NEMA 4X
    UL Listed
    9766K96000000
    1 1/2
    FemaleNPT
    26125 psi @ 355° FPressure Drop Assisted, Solenoid-40 to 3554 7/8"6 15/16"NEMA 4X
    UL Listed
    9766K97000000
    2
    FemaleNPT
    48150 psi @ 365° FPressure Drop Assisted, Solenoid-40 to 3655 7/8"7 9/16"NEMA 4X
    UL Listed
    9766K13200000000
     
    316 Stainless Steel Body with Wire Lead Connection—PTFE Seal
    Image of Product. Front orientation. Contains Annotated. Solenoid On/Off Valves. Solenoid On/Off Valves for Steam, 316 Stainless Steel Body with Wire Lead Connection—PTFE Seal.
    316 stainless steel valves are more corrosion resistant than brass and bronze valves.
    Fail-Closed Valve—Fail closed valves are closed unless actuated.
    Pressure Drop Assisted Valve—Pressure drop assisted valves require a minimum pressure drop between the inlet and the outlet for operation; the upstream pressure must be greater than the downstream pressure.
    NEMA 4X Enclosure Rating—NEMA 4X valves resist washdowns, splashing water, corrosive liquid, and dust.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    Gender
    Thread
    Type
    Flow Coefficient
    (Cv)
    Max. Steam Pressure
    @ Temp.
    Valve Type
    Temp.,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Enclosure
    Rating
    Certification
    Flammability
    Rating
    Each
    Fail Closed—120V AC
    1 1/4
    FemaleNPT
    22150 psi @ 365° FPressure Drop Assisted, Solenoid35 to 3656 1/4"5 13/16"NEMA 4X
    UL Listed, CSA Certified
    UL 94 HB
    49225K770000000
    1 1/2
    FemaleNPT
    28150 psi @ 365° FPressure Drop Assisted, Solenoid35 to 3656 1/4"5 13/16"NEMA 4X
    UL Listed, CSA Certified
    UL 94 HB
    49225K78000000
    2
    FemaleNPT
    29150 psi @ 365° FPressure Drop Assisted, Solenoid35 to 3656 5/16"6 9/16"NEMA 4X
    UL Listed, CSA Certified
    UL 94 HB
    49225K79000000
     