McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    18 Products

    Submersible Liquid-Level Transmitters

    Image of Product. Front orientation. Liquid-Level Transmitters. Submersible Liquid-Level Transmitters, For Liquids.
    Image of Product. Top orientation. Liquid-Level Transmitters. Submersible Liquid-Level Transmitters, For Liquids with Solids.

    For Liquids

    For

    Liquids

    with

    Solids

    Best for measuring liquid levels in applications where traditional mounting is difficult, these transmitters sit at the bottom of your tank. They sense liquid levels by measuring the pressure from the weight of the liquid above them. These transmitters continuously send measurements, so you can monitor the status and manage components in your system. Also known as level loggers, level sensors, and pressure transducers.
    For Liquids with Solids—Transmitters for liquids with solids have sink weights that keep the transmitter in place in applications with moving solids or agitated liquids.
    Overall
    For Pressure
    Accuracy
    Max. Pressure
    @ Temp.
    Dia.
    Lg.
    Temp. Range,
    ° F
    Cable Lg.,
    ft.
    Input Voltage,
    V DC
    For Container Type
    Electrical
    Connection
    Enclosure
    Rating
    Each
    4 mA to 20 mA Output Current
     
    For Liquids
    0 to 5 psi / 0 to 11.5 ft. H₂O±0.5%7 psi @ 70° F1"5 5/8"32 to 1404012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N110000000
    0 to 10 psi / 0 to 23 ft. H₂O±0.5%15 psi @ 70° F1"5 5/8"32 to 1404012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N12000000
    0 to 15 psi / 0 to 34 ft. H₂O±0.5%22 psi @ 70° F1"5 5/8"32 to 1406012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N13000000
    0 to 20 psi / 0 to 46 ft. H₂O±0.5%30 psi @ 70° F1"5 5/8"32 to 1406012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N14000000
     
    For Liquids with Solids
    0 to 5 psi / 0 to 11.5 ft. H₂O±0.5%7 psi @ 70° F3 1/4"5 1/4"32 to 1404012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N15000000
    0 to 10 psi / 0 to 23 ft. H₂O±0.5%15 psi @ 70° F3 1/4"5 1/4"32 to 1404012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N16000000
    0 to 15 psi / 0 to 34 ft. H₂O±0.5%22 psi @ 70° F3 1/4"5 1/4"32 to 1406012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N17000000
    0 to 20 psi / 0 to 46 ft. H₂O±0.5%30 psi @ 70° F3 1/4"5 1/4"32 to 1406012 to 36Closed Tank, Open TankWire LeadsIP68
    3962N18000000
     

    Hazardous-Location Submersible Liquid-Level Transmitters

    Image of Product. Front orientation. Liquid-Level Transmitters. Hazardous-Location Submersible Liquid-Level Transmitters, For Liquids.
    Image of Product. Front orientation. Liquid-Level Transmitters. Hazardous-Location Submersible Liquid-Level Transmitters, For Liquids with Solids.

    For Liquids

    For Liquids with Solids

    FM and C-FM approved, these transmitters safely measure liquid levels where explosive gas or dust may be present. Set them at the bottom of your tank in applications that make traditional mounting difficult. They sense liquid levels by measuring the pressure from the weight of the liquid above them. All continuously send measurements, so you can monitor status and manage components in your system. Also known as level loggers, level sensors, and pressure transducers.
    For Liquids with Solids—Transmitters for liquids with solids have an unobstructed sensing element that resists clogging and sludge buildup in water with particulate and sewage.
    Overall
    For Pressure
    Accuracy
    Max. Pressure
    @ Temp.
    Dia.
    Lg.
    Temp. Range,
    ° F
    Cable Lg.,
    ft.
    Input Voltage,
    V DC
    For Container
    Type
    Electrical
    Connection
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    4 mA to 20 mA Output Current
     
    For Liquids
    0 psi to 1 psi / 0 to 3 ft. H₂O±0.25%10 psi @ 70° F1"6 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K510000000
    0 to 2 psi / 0 to 5 ft. H₂O±0.25%20 psi @ 70° F1"6 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K53000000
    0 to 4 psi / 0 to 10 ft. H₂O±0.25%40 psi @ 70° F1"6 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K55000000
    0 to 6 psi / 0 to 15 ft. H₂O±0.25%60 psi @ 70° F1"6 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K57000000
    0 to 13 psi / 0 to 30 ft. H₂O±0.25%125 psi @ 70° F1"6 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K59000000
     
    For Liquids with Solids
    0 psi to 1 psi / 0 to 3 ft. H₂O±0.25%10 psi @ 70° F1"5 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K3100000000
    0 to 2 psi / 0 to 5 ft. H₂O±0.25%20 psi @ 70° F1"5 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K3300000000
    0 to 4 psi / 0 to 10 ft. H₂O±0.25%40 psi @ 70° F1"5 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K3500000000
    0 to 6 psi / 0 to 15 ft. H₂O±0.25%60 psi @ 70° F1"5 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K3700000000
    0 to 13 psi / 0 to 30 ft. H₂O±0.25%125 psi @ 70° F1"5 3/4"-10 to 1754010 to 35Open TankWire LeadsNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEMA 6P
    3450K3900000000
     
    back to top