    64 Products

    Vacuum Cleaners for Wet Pickup

    Image of Product. Front orientation. Vacuum Cleaners. Vacuum Cleaners for Wet Pickup.
    Useful for flood applications, these vacuum cleaners pick up large amounts of water quickly. They automatically pump out water, so you don't have to empty the tank. The stainless steel tank resists corrosion from standing water and harsh cleaning chemicals. A built-in GFCI protects against electrical shock when operating around water. The liquid overflow shut-off valve prevents water from reaching the motor if the tank fills beyond capacity. Included extension wands and a squeegee nozzle help you reach under equipment and direct water across flat surfaces.
    Suction
    Hose
    Discharge
    Hose
    Cap.,
    gal.
    Ht.
    Wd.
    Dp.
    Power,
    hp
    Current,
    amp
    Voltage,
    V AC
    Cord Lg.,
    ft.
    Suction
    Rate, gpm
    Dia.
    Lg.,
    ft.
    Discharge
    Rate, gpm
    Dia.
    Lg.,
    ft.
    Features
    Includes
    Each
    Stainless Steel Tank
    1938"23"24"1.61212025531 1/2"13801 1/2"25Ground Fault Circuit Interrupter (GFCI)
    Liquid Overflow Shut-Off Valve
    (2) 20" Lg. Extension Wands
    One 15" Lg. Curved Extension Wand
    Squeegee Nozzle
    71065T68000000000
     
    Vacuum Cleaner Hose

    Pump-Out Drum-Top Vacuum Cleaners for Wet Pickup

    Image of ProductInUse. Front orientation. Vacuum Cleaners. Pump-Out Drum-Top Vacuum Cleaners for Wet Pickup.
    Use to empty or fill sumps and other liquid reservoirs—these continuous-use vacuum cleaners pump in and out (turn the knob to switch from pumping in to pumping out). Unlike other drum-top vacuums, they work only with closed-head drums that have two openings (not included). These vacuum cleaners remove coolant, sludge, slurries, and metal chips.
    Hose
    Air Inlet
    For Drum
    Cap., gal.
    For Drum
    Style
    For Min.
    Drum Ga.
    Airflow @ Pressure
    Dia.
    Ht.
    Dia.
    Lg.,
    ft.
    Connection
    Thread
    Type
    Gender
    Pipe
    Size
    Suction
    Rate, gpm
    Discharge
    Rate, gpm
    Features
    Includes
    Each
    Stainless Steel Housing
    30Closed Head1619 ft³/min @ 80 psi3"11 1/2"1 1/2"10ThreadedNPT
    Male1/4
    3030Liquid Overflow Shut-Off Valve18" Lg. Extension Wand
    90° Quick-Disconnect Elbow
    9798T110000000
    55Closed Head1619 ft³/min @ 80 psi3"11 1/2"1 1/2"10ThreadedNPT
    Male1/4
    3030Liquid Overflow Shut-Off Valve18" Lg. Extension Wand
    90° Quick-Disconnect Elbow
    9798T56000000
    110Closed Head1619 ft³/min @ 80 psi3"11 1/2"1 1/2"10ThreadedNPT
    Male1/4
    3030Liquid Overflow Shut-Off Valve18" Lg. Extension Wand
    90° Quick-Disconnect Elbow
    9798T12000000
     
    Vacuum Cleaner Hose

    Drum-Top Vacuum Cleaners for Wet Pickup

    Image of Product. Front orientation. Vacuum Cleaners. Drum-Top Vacuum Cleaners for Wet Pickup.
    Remove coolant, sludge, slurries, and metal chips from sumps and other liquid reservoirs with these continuous-use vacuum cleaners.
    Hose
    Air Inlet
    For Drum
    Cap., gal.
    For Drum
    Style
    For Min.
    Drum Ga.
    Airflow @ Pressure
    Dia.
    Ht.
    Dia.
    Lg.,
    ft.
    Connection
    Thread
    Type
    Gender
    Pipe
    Size
    Suction
    Rate, gpm
    Features
    Includes
    Each
    Steel Housing
    55Open Head1680 ft³/min @ 120 psi24"6 1/2"1 1/2"16ThreadedNPT
    Male1/2
    70Liquid Overflow Shut-Off Valve20-ft. Oil-Resistant Rubber Air Hose
    Crevice Tool
    Flexible Nozzle
    Utility Nozzle
    7290T12000000000
     
    Replacements for Vacuum Cleaners

    Miniature Drum-Top Vacuum Cleaners for Wet Pickup

    Image of Product. Front orientation. Vacuum Cleaners. Miniature Drum-Top Vacuum Cleaners for Wet Pickup.
    Clean up minor liquid spills in tight spaces where full-size units won't fit. Our smallest drum-top vacuums run continuously and are pneumatically powered, so they require no electricity. That makes them safe to operate around liquids and in environments where electric motors pose a spark hazard. Steel housing stands up to industrial use. A liquid overflow shut-off valve stops airflow before liquid reaches the motor, protecting the vacuum from damage. A crevice tool and round suction nozzle are included for versatile cleanup.
    Hose
    Air Inlet
    For Drum
    Cap., gal.
    For Drum
    Style
    Airflow @ Pressure
    Dia.
    Ht.
    Dia.
    Lg.,
    ft.
    Connection
    Thread
    Type
    Gender
    Pipe
    Size
    Features
    Includes
    Each
    Steel Housing
    5Open Head12.7 ft³/min @ 85 psi12"15"1 1/4"6 1/2ThreadedNPT
    Female3/8
    Liquid Overflow Shut-Off ValveCrevice Tool
    Round Suction Nozzle
    63605T270000000
     
    Accessories and Replacements for Vacuum Cleaners

    Cut-to-Size Suction Strainers with Backflow-Prevention Valve

    A convenient replacement part to keep on hand, this strainer has NPT male threads for a variety of pipe sizes. Use a hacksaw to remove the pipe sizes that are smaller than you need. Also known as a foot valve, this strainer stops particles from entering your line while preventing backward flow. It is commonly used with reservoirs and tanks. It has an acetal connection, which is corrosion resistant and lightweight.
    With Male Threaded Pipe Fitting Connections
    Image of Product. Front orientation. Strainers. Cut-to-Size Suction Strainers with Backflow-Prevention Valve.
    Temp.
    Range, ° F
    Connection
    Pipe Size
    Thread
    Type
    Min.
    Max.
    Ht.
    Dia.
    Gasket
    Material
    Material
    Color
    Screen
    Material
    Screen Opening
    Size
    Each
    For Use With Water
     
    With Perforated Screen
    3/4, 1, 1 1/4, 1 1/2
    NPT
    321807"1 15/16"Neoprene
    AcetalWhiteAcetal3/32"4492K121000000
     

    Suction Strainers with Backflow-Prevention Valve

    Also known as foot valves, these strainers stop particles from entering your line while preventing backward flow. They are commonly used with reservoirs and tanks.
    With Bronze Female Threaded Pipe Fitting Connections
    Image of Product. Front orientation. Strainers. Suction Strainers with Backflow-Prevention Valve, With Bronze Female Threaded Pipe Fitting Connections.
    Strainers with bronze or PVC connection have better corrosion resistance than strainers with an iron connection; bronze strainers are often used in water-delivery applications.
    Pipe
    Size
    Thread
    Type
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Ht.
    Dia.
    Gasket
    Material
    Screen Material
    Screen Opening
    Size
    Each
    For Use With Water
    3/4
    NPT
    40032 to 1903 3/4"1 3/8"Buna-N
    430 Stainless Steel7/64"4856K111000000
    1
    NPT
    40032 to 1904 3/4"1 3/4"Buna-N
    430 Stainless Steel7/64"4856K12100000
    1 1/4
    NPT
    40032 to 1905"2 1/16"Buna-N
    430 Stainless Steel7/64"4856K13100000
    1 1/2
    NPT
    40032 to 1906 5/16"2 5/8"Buna-N
    430 Stainless Steel7/64"4856K14100000
    2
    NPT
    40032 to 1907 3/16"3 1/2"Buna-N
    430 Stainless Steel7/64"4856K151000000
    3
    NPT
    40032 to 1909 1/2"4 5/8"Buna-N
    430 Stainless Steel7/64"4856K171000000
     
    With Bronze Male and Female Threaded Pipe Fitting Connections
    Image of Product. Front orientation. Strainers. Suction Strainers with Backflow-Prevention Valve, With Bronze Male and Female Threaded Pipe Fitting Connections.
    Strainers with male and female threaded pipe connection have threads on the outside and inside of the fitting for connecting to either male or female threaded pipe.
    Strainers with bronze or PVC connection have better corrosion resistance than strainers with an iron connection; bronze strainers are often used in water-delivery applications.
    Female Threaded
    Pipe Connection
    Male Threaded
    Pipe Connection
    Pipe
    Size
    Thread
    Type
    Pipe
    Size
    Thread
    Type
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Ht.
    Dia.
    Gasket
    Material
    Screen Material
    Screen Opening
    Size
    Each
    For Use With Water
    3/4
    NPT
    1
    NPT
    40032 to 1903 3/4"1 5/16"Buna-N
    430 Stainless Steel7/64"4856K211000000
    1
    NPT
    1 1/4
    NPT
    40032 to 1905"1 5/8"Buna-N
    430 Stainless Steel7/64"4856K22100000
    1 1/4
    NPT
    1 1/2
    NPT
    40032 to 1905"1 15/16"Buna-N
    430 Stainless Steel7/64"4856K23100000
     
    With Iron Female Threaded Pipe Fitting Connections
    Image of Product. Front orientation. Strainers. Suction Strainers with Backflow-Prevention Valve, With Iron Female Threaded Pipe Fitting Connections.
    Strainers
    Replacement
    Flappers
    Pipe
    Size
    Thread
    Type
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Ht.
    Dia.
    Flapper
    Material
    Screen
    Material
    Screen Opening
    Size
    Each
    Each
    For Use With Water and Oil
    1 1/2
    NPT
    1032 to 1504 1/8"4 5/8"LeatherIron5/16"5436K33100000005436K61000000
    2
    NPT
    1032 to 1505 1/4"5 3/8"LeatherIron5/16"5436K3410000005436K6200000
    3
    NPT
    1032 to 1507 3/16"7 5/8"LeatherIron5/16"5436K3610000005436K6300000
    4
    NPT
    1032 to 1508 7/8"9 1/16"LeatherIron5/16"5436K3710000005436K6400000
    6
    NPT
    1032 to 15012"11 7/16"LeatherIron5/16"5436K3910000005436K66000000
     
    With PVC Female Threaded Pipe Fitting Connections
    Image of Product. Front orientation. Strainers. Suction Strainers with Backflow-Prevention Valve, With PVC Female Threaded Pipe Fitting Connections.
    Strainers with bronze or PVC connection have better corrosion resistance than strainers with an iron connection; bronze strainers are often used in water-delivery applications.
    Two Union End Connections—Strainers with two union end connections allow for easy access to your line; they come with either two threaded pipe connections or one socket-connect pipe connection and one threaded pipe connection.
    Strainers
    Replacement
    Screens
    Pipe
    Size
    Thread
    Type
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Ht.
    Dia.
    Gasket
    Material
    Screen
    Material
    Screen
    OD
    Screen
    Lg.
    Features
    Screen Opening
    Size
    Each
    Each
    For Use With Water, Oil, and Diesel Fuel
    3
    NPT
    15040 to 14011 1/4"6 9/16"Fluoroelastomer
    PVC6 35/64"2 1/2"Two Union End Connections3/16"4441K56100000004441K360000000
    4
    NPT
    15040 to 14014 5/8"8 9/16"Fluoroelastomer
    PVC8 35/64"4 1/4"Two Union End Connections3/16"4441K591000000004441K37000000
     
    With PVC Female Threaded and Cement-Socket-Connect Pipe Fitting Connections
    Image of Product. Front orientation. Strainers. Suction Strainers with Backflow-Prevention Valve, With PVC Female Threaded and Cement-Socket-Connect Pipe Fitting Connections.
    Strainers with bronze or PVC connection have better corrosion resistance than strainers with an iron connection; bronze strainers are often used in water-delivery applications.
    Strainers with socket-connect pipe fitting connections attach to unthreaded pipe with cement for a permanent, leak-tight connection.
    Two Union End Connections—Strainers with two union end connections allow for easy access to your line; they come with either two threaded pipe connections or one socket-connect pipe connection and one threaded pipe connection.
    Strainers
    Replacement
    Screens
    Threaded Pipe
    Connection
    Pipe
    Size
    Thread
    Type
    Cement-Socket-Connect Pipe
    Connections Pipe Size
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Ht.
    Dia.
    Gasket
    Material
    Screen
    Material
    Screen
    OD
    Screen
    Lg.
    Features
    Screen Opening
    Size
    Each
    Each
    For Use With Water, Oil, and Diesel Fuel
    1/2
    NPT
    1/2
    15040 to 1404 7/8"2 1/4"Fluoroelastomer
    PVC2 1/4"2 5/16"Two Union End Connections3/16"4441K51100000004441K31000000
    3/4
    NPT
    3/4
    15040 to 1405"2 5/8"Fluoroelastomer
    PVC2 5/8"2 19/32"Two Union End Connections3/16"4441K5210000004441K3200000
    1
    NPT
    1
    15040 to 1405 7/8"3"Fluoroelastomer
    PVC3"2 7/8"Two Union End Connections3/16"4441K5310000004441K3300000
    1 1/4
    NPT
    1 1/4
    15040 to 1406 15/16"4"Fluoroelastomer
    PVC4"3 3/4"Two Union End Connections3/16"4441K5710000004441K34000000
    1 1/2
    NPT
    1 1/2
    15040 to 1407 1/16"4"Fluoroelastomer
    PVC4"3 3/4"Two Union End Connections3/16"4441K5410000004441K34000000
    2
    NPT
    2
    15040 to 1408 9/16"4 3/4"Fluoroelastomer
    PVC4 3/4"4 1/2"Two Union End Connections3/16"4441K5510000004441K35000000
     

    Sump Pump Backflow-Prevention Valves with Clamps

    Image of Product. Front orientation. Sump Pump Backflow-Prevention Valves. Sump Pump Backflow-Prevention Valves with Clamps.
    Prevent dirty water from flowing back to your pump. Valves have flexible couplers with hose clamps to slip over PVC tubing for easy installation. At least 2 psi is required to open valves. Install for horizontal or upward flow.
    Pipe Size
    Max. Pressure
    @ Temp.
    Max. Flow Rate @
    10 ft. of Head, gpm
    Temp. Range,
    ° F
    Body
    Material
    Color
    Seal Material
    End-to-End
    Lg.
    Each
    1 1/4, 1 1/2
    25 psi @ 70° F4.335 to 130ABS
    BlackEPDM/Stainless Steel
    4 13/16"7744K11000000
    2
    25 psi @ 70° F4.335 to 130ABS
    GreenEPDM/Stainless Steel
    6"7744K1200000

    Suction Strainers

    Image of Product. Style A. Front orientation. Strainers. Suction Strainers, For Use With Water, Oil, and Paint, Style A.
    Image of Product. Style B. Front orientation. Strainers. Suction Strainers, For Use With Water, Oil, and Paint, Style B.
    Image of Product. Style F. Bottom orientation. Strainers. Suction Strainers, For Use With Water and Oil, Style F.

    Style A

    Style B

    Style F

    Commonly used with reservoirs and tanks, these strainers filter particles before they enter your system.
    Nylon Connection—Strainers with nylon connection have better corrosion resistance than strainers with aluminum or steel connections.
    Temp.
    Range
    Style
    Pipe
    Size
    Thread
    Type
    Gender
    Min.
    Max.,
    ° F
    Ht.
    Dia.
    Screen Material
    Choose a Screen
    Mesh Size
    Each
    For Use With Water, Oil, and Paint
     
    Nylon Connection
    A1/8
    NPT
    FemaleNot Rated2254 5/16"2 1/4"Nylon30 × 30
    9812K31000000
    A1/4
    NPT
    FemaleNot Rated2254 5/16"2 1/4"Nylon30 × 30
    9812K3200000
    A3/8
    NPT
    FemaleNot Rated2254 5/16"2 1/4"Nylon30 × 30
    9812K3300000
    A1/2
    NPT
    FemaleNot Rated2254 5/16"2 1/4"Nylon30 × 30
    9812K3400000
    A3/4
    NPT
    FemaleNot Rated2254 5/16"2 1/4"Nylon30 × 30
    9812K3500000
    B3/8
    NPT
    MaleNot Rated2255 5/16"2 1/4"Nylon30 × 30
    9812K4100000
    B1/2
    NPT
    MaleNot Rated2255 5/16"2 1/4"Nylon30 × 30
    9812K4200000
    B3/4
    NPT
    MaleNot Rated2255 5/16"2 1/4"Nylon30 × 30
    9812K4300000
     
    For Use With Water and Oil
     
    304 Stainless Steel Connection
    F3/4
    NPT
    FemaleNot Rated2703 1/16"3 1/16"304 Stainless Steel60 × 60, 100 × 1004455K4200000
    F1
    NPT
    FemaleNot Rated2705 9/16"3 3/16"304 Stainless Steel60 × 60, 100 × 1004455K4300000
    F1 1/4
    NPT
    FemaleNot Rated2707 1/8"3 3/16"304 Stainless Steel60 × 60, 100 × 1004455K44000000
    F1 1/2
    NPT
    FemaleNot Rated2709 5/8"4 3/16"304 Stainless Steel60 × 60, 100 × 1004455K45000000
    F2
    NPT
    FemaleNot Rated2709 5/8"4 3/16"304 Stainless Steel60 × 60, 100 × 1004455K46000000
    F3
    NPT
    FemaleNot Rated27012 5/8"5 3/16"304 Stainless Steel60 × 60, 100 × 1004455K48000000
     
    back to top