McMaster-Carr logo
    Filter by
    Mounting Location
    Electrical Phase
    Number of Speeds
    Blade Material
    Drive Type
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    67 Products

    Ceiling Fans

    Mount these fans on flat ceilings. They include a support cable or downrods to mount them into joists. All have optional speed control.
    Fans
    Image of Product. Front orientation. Fans. Ceiling Fans.
    Image of Product. Front orientation. Fan Installation Kits. Ceiling Fans.

    Installation Kits

    Installation Kits—Installation kits (sold separately) allow fans to mount between joists.
    Fans
    Installation
    Kits
    Blade
    Dia.
    Material
    Rotation
    Color
    Airflow
    No. of
    Speeds
    Current
    For Min. Ceiling
    Ht., ft.
    Mounting Fasteners
    Included
    Certification
    Includes
    Each
    Each
    120V AC, Single Phase—Hardwire
     
    Non-Oscillating Fan
    36"Painted SteelReversibleWhite2,126 ft³/min10.3 amp10YesC-UL Listed, UL Listed
    24" Downrod, Support Cable000000000000000000000000000
    48"Painted SteelReversibleWhite3,861 ft³/min10.4 amp10YesC-UL Listed, UL Listed
    24" Downrod, Support Cable0000000000000000000000000
    56"Painted SteelNonreversibleWhite8,959 ft³/min10.9 amp10YesC-UL Listed, UL Listed
    24" Downrod, Support Cable0000000000000000000000000
    60"Painted SteelNonreversibleWhite6,090 ft³/min10.6 amp10YesC-UL Listed, UL Listed
    24" Downrod, Support Cable0000000000000000000000000
     
    Fans with LED
    Image of Product. Front orientation. Fans. Ceiling Fans, Fans with LED, Plastic Blade.
    Image of Product. Front orientation. Fans. Ceiling Fans, Fans with LED, Powder-Coated Aluminum Blade.

    Plastic Blade

    Powder-Coated Aluminum Blade

    Cannot Be Sold to Canada—Fans that cannot be sold to the listed regions do not meet energy efficiency regulations.
    Blade
    Dia.
    Material
    Rotation
    Color
    Airflow
    No. of
    Speeds
    Current
    Brightness,
    lm
    For Min. Ceiling
    Ht., ft.
    Mounting Fasteners
    Included
    Certification
    Specs.
    Met
    Cannot Be
    Sold To
    Includes
    Each
    120V AC, Single Phase—Hardwire
     
    Non-Oscillating Fan
    60"PlasticReversibleWhite6,600 ft³/min60.7 amp1,5209YesETL Listed
    2" Downrod, 9" Downrod, Remote Control00000000000000
    60"Powder-Coated AluminumReversibleBlack13,000 ft³/min80.5 amp2,60011YesETL Listed
    UL 50711" Downrod, Remote Control000000000000000
    72"Powder-Coated AluminumReversibleBlack17,900 ft³/min80.6 amp2,60011YesETL Listed
    UL 50711" Downrod, Remote Control000000000000000
    84"Powder-Coated AluminumReversibleBlack22,100 ft³/min80.5 amp2,60011YesETL Listed
    UL 50711" Downrod, Remote Control000000000000000
    96"Powder-Coated AluminumReversibleBlack22,000 ft³/min81.1 amp2,60011YesETL Listed
    UL 507Canada11" Downrod, Remote Control000000000000000
     

    Corrosion-Resistant Direct-Drive Ceiling-Mount Fans

    With a polyethylene housing, these fans are durable and resist rust. They’re direct-drive fans, so they have fewer moving parts than belt-drive fans for less maintenance.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Shown Mounted with Chains (Not Included). Front orientation. Fans. Corrosion-Resistant Direct-Drive Ceiling-Mount Fans.

    Shown Mounted with Chains (Not

    Included)

    Blade
    Overall
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.
    Wd.
    Dp.
    Cord Lg.,
    ft.
    Drive
    Type
    Housing
    Material
    Guard Material
    Certification
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan
    30"Aluminum4,400 ft³/min77 dB @ 15 ft.1,05021/42.7 amp31 5/8"30 3/8"13 3/4"12DirectPolyethylenePowder-Coated SteelC-ETL Listed, ETL Listed
    00000000000000
    36"Aluminum6,500 ft³/min79 dB @ 15 ft.1,05021/35.5 amp37 5/8"36 5/8"13 3/4"12DirectPolyethylenePowder-Coated SteelC-ETL Listed, ETL Listed
    0000000000000
    42"Aluminum9,000 ft³/min77 dB @ 15 ft.82511/27.9 amp43 5/8"43"13 3/4"12DirectPolyethylenePowder-Coated SteelC-ETL Listed, ETL Listed
    0000000000000
     

    Destratification Fans for Areas with High Ceilings

    Continuously mix and circulate air to balance room temperature in spaces where there is a large difference in temperature between the floor and ceiling. They prevent you from over cooling or heating a space to maintain your desired temperature. All have a polyethylene plastic housing that is durable and resists rust.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Fans. Destratification Fans for Areas with High Ceilings.
    Image of Attribute. Front orientation. Contains Annotated. Destratification Fans for Areas with High Ceilings.
    IP66 Enclosure Rating—The motor is rated IP66 for protection against dust and washdowns.
    Blade
    Mounting
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Cord Lg.,
    ft.
    Drive
    Type
    Housing
    Material
    Guard Material
    For Min. Ceiling
    Ht., ft.
    Fasteners
    Included
    Hole
    Dia.
    Enclosure
    Rating
    Each
    120V AC 240V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan
    18"Plastic1,700 ft³/minNot Rated1,00011/33.9 amp 1.9 amp8DirectPolyethylenePowder-Coated Steel7No1/4"IP66
    00000000000000
     

    Economy Beam-Mount Fans

    Image of ProductInUse. Front orientation. Fans. Economy Beam-Mount Fans.
    Attach these fans to beams to direct air where it’s needed. They have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty and dusty environments.
    Fans with Totally Enclosed Motor Enclosure
    Fans
    Replacement
    Fan Motors
    Blade
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Cord Lg.,
    ft.
    Drive
    Type
    Guard Material
    For Beam
    Wd.
    Mounting Fasteners
    Included
    Certification
    Each
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan
    18"Steel3,100 ft³/min57 dBA @ 15 ft.1,50031/61.5 amp9DirectPowder-Coated Steel4" to 14"YesETL Listed
    000000000000000000000000000
    20"Steel3,600 ft³/min52 dBA @ 15 ft.1,50031/61.6 amp9DirectPowder-Coated Steel4" to 14"YesETL Listed
    0000000000000000000000000
    24"Steel5,100 ft³/min62 dBA @ 15 ft.1,05031/42.4 amp10DirectPowder-Coated Steel4" to 14"YesETL Listed
    00000000000000000000000000
    30"Steel7,400 ft³/min65 dBA @ 15 ft.1,02531/42.4 amp10DirectPowder-Coated Steel4" to 14"YesETL Listed
    00000000000000000000000000
     
    Oscillating Fan
    30"Steel7,400 ft³/min65 dBA @ 15 ft.1,02531/42.4 amp10DirectPowder-Coated Steel4" to 14"YesETL Listed
    00000000000000000000000000
     

    Economy Ceiling-Mount Fans

    Hanging from the ceiling, these fans direct air where it's needed. A direct-drive motor means these fans have fewer moving parts than fans with belt-drive motors for less maintenance. A totally enclosed motor enclosure means these fans can be used in dirty and dusty environments. Threaded extension pipe for mounting is not included.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Shown With Extension Pipe (Not Included). Front orientation. Fans. Economy Ceiling-Mount Fans.

    Shown With Extension Pipe

    (Not Included)

    Cannot Be Sold to California—These fans cannot be sold to California due to local energy efficiency requirements.
    Fans
    Replacement
    Fan Motors
    Blade
    Mounting
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Cord Lg.,
    ft.
    Drive
    Type
    Guard Material
    Fasteners
    Included
    Hole
    Dia.
    Req. Pipe
    Size
    Certification
    Cannot Be
    Sold To
    Includes
    Each
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan
    18"Steel3,100 ft³/min57 dBA @ 15 ft.1,50031/61.5 amp9DirectPowder-Coated SteelNo3/8"1 1/2
    ETL Listed
    CaliforniaMounting Bracket000000000000000000000000000
    20"Steel3,600 ft³/min52 dBA @ 15 ft.1,50031/61.6 amp9DirectPowder-Coated SteelNo3/8"1 1/2
    ETL Listed
    CaliforniaMounting Bracket0000000000000000000000000
    30"Steel7,400 ft³/min65 dBA @ 15 ft.1,02531/42.4 amp10DirectPowder-Coated SteelNo3/8"1 1/2
    ETL Listed
    CaliforniaMounting Bracket00000000000000000000000000
     

    Hazardous Location Beam-Mount Fans

    These fans have a motor that is UL listed for Class I, Group D; Class II, Groups E, F, and G hazardous environments. They are often used in welding shops and oil refineries. Fans have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Fans. Hazardous Location Beam-Mount Fans.
    Blade
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Drive
    Type
    Hazardous Location Rating
    Guard Material
    For Beam
    Wd.
    Mounting Fasteners
    Included
    Certification
    Each
    120/230V AC, Single Phase—Hardwire
     
    Non-Oscillating Fan
    24"Aluminum5,700 ft³/min67 dB @ 5 ft.1,12511/46.9 amp/3.5 ampDirectNEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups E, F, G
    Chrome-Plated Steel2" to 15"YesUL Listed
    0000000000000000
    30"Aluminum8,700 ft³/min72 dB @ 5 ft.1,12511/46.9 amp/3.5 ampDirectNEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups E, F, G
    Chrome-Plated Steel2" to 15"YesUL Listed
    000000000000000
     

    High-Output Beam-Mount Fans

    Generate at least 25% greater airflow than economy and premium fans. All of these fans have a long-lasting direct-drive motor with ball bearings, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty and dusty environments.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Fans. High-Output Beam-Mount Fans.
    Blade
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Cord Lg.,
    ft.
    Drive
    Type
    Guard Material
    For Beam
    Wd.
    Mounting Fasteners
    Included
    Each
    208-230/460V AC, Three Phase—Hardwire
     
    Non-Oscillating Fan
    30"Steel12,400 ft³/min71 dB @ 15 ft.1,125114.0 amp 2.0 ampDirectChrome-Plated Steel4" to 14"Yes0000000000000000
     
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan
    24"Aluminum7,400 ft³/min77 dB @ 15 ft.1,10021/25.0 amp15DirectChrome-Plated Steel4" to 14"Yes0000000000000
    30"Aluminum9,700 ft³/min79 dB @ 15 ft.1,10021/25.0 amp15DirectChrome-Plated Steel4" to 14"Yes0000000000000
     

    High-Output Ceiling-Mount Fans

    Generate at least 25% greater airflow than economy and premium fans. All of these fans have a long-lasting direct-drive motor with ball bearings, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty and dusty environments. Threaded extension pipe for mounting is not included.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Shown With Extension Pipe (Not Included). Front orientation. Fans. High-Output Ceiling-Mount Fans.

    Shown With

    Extension Pipe

    (Not Included)

    Blade
    Mounting
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Cord Lg.,
    ft.
    Drive
    Type
    Guard Material
    Fasteners
    Included
    Hole
    Dia.
    Req. Pipe
    Size
    Includes
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan
    24"Aluminum7,400 ft³/min77 dB @ 5 ft.1,10021/25.0 amp15DirectChrome-Plated SteelNo3/8"1
    Mounting Bracket00000000000000
    30"Aluminum9,700 ft³/min79 dB @ 5 ft.1,10021/25.0 amp15DirectChrome-Plated SteelNo3/8"1
    Mounting Bracket0000000000000
     

    Low-Profile Direct-Drive Ceiling-Mount Fans

    Ideal for low-clearance applications where you need headroom, these direct-drive fans are compact and have fewer moving parts than belt-drive fans for less maintenance. The louvers adjust so you can direct airflow in two directions at the same time. They have a polyethylene housing, so they’re durable and resist corrosion.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Fans. Low-Profile Direct-Drive Ceiling-Mount Fans.
    Blade
    Overall
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.
    Wd.
    Dp.
    Drive
    Type
    Housing
    Material
    Enclosure
    Rating
    Includes
    Each
    208V AC to 240V AC, Single Phase—Hardwire
     
    Non-Oscillating Fan
    58"Plastic40,400 ft³/minNot Rated600139.9 amp to 11.3 amp65 1/4"65 1/4"31"DirectPolyethyleneIP65
    Mounting Chain Kit0000000000000000
     
    190/208/240V AC, Three Phase—Hardwire
     
    Non-Oscillating Fan
    58"Plastic40,100 ft³/minNot Rated6001310.9 amp
    11.7 amp
    10.1 amp
    65 1/4"65 1/4"31"DirectPolyethyleneIP65
    Mounting Chain Kit000000000000000
     
    380/460V AC, Three Phase—Hardwire
     
    Non-Oscillating Fan
    58"Plastic41,000 ft³/minNot Rated600136.2 amp
    5.2 amp
    65 1/4"65 1/4"31"DirectPolyethyleneIP65
    Mounting Chain Kit000000000000000
     

    Panel Fans

    Image of ProductInUse. Shown Mounted with Chains (Not Included). Front orientation. Fans. Panel Fans.

    Shown Mounted with

    Chains (Not Included)

    Mount these fans to a wide range of surfaces, such as posts, columns, and ceilings. They’re direct-drive fans, so they have fewer moving parts than belt-drive fans and require less maintenance. To suspend them, use the mounting chain kit (sold separately). Use mounting brackets (sold separately) to mount them to posts and columns.
    Fans with Totally Enclosed Motor Enclosure
    Blade
    Overall
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.
    Wd.
    Dp.
    Drive
    Type
    Frame Material
    Enclosure
    Rating
    Each
    190V AC to 208V AC/208V AC to 240V AC, Three Phase—Hardwire
     
    Non-Oscillating Fan
    55"Plastic37,500 ft³/minNot Rated60012 15/1610.9 amp to 11.7 amp
    10.1 amp to 11.7 amp
    59"59"17 3/4"DirectGalvanized SteelIP65
    0000000000000000
    60"Plastic40,300 ft³/minNot Rated60012 15/1610.9 amp to 11.7 amp
    10.1 amp to 11.7 amp
    66"66"17 3/4"DirectGalvanized SteelIP65
    000000000000000
     
    208V AC to 240V AC, Single Phase—Hardwire
     
    Non-Oscillating Fan
    50"Plastic30,800 ft³/minNot Rated60012 15/169.9 amp to 11.3 amp54"54"17 3/4"DirectGalvanized SteelIP65
    000000000000000
    55"Plastic37,400 ft³/minNot Rated60012 15/169.9 amp to 11.3 amp59"59"17 3/4"DirectGalvanized SteelIP65
    000000000000000
    60"Plastic40,800 ft³/minNot Rated60012 15/169.9 amp to 11.3 amp66"66"17 3/4"DirectGalvanized SteelIP65
    000000000000000
     
    380V AC to 460V AC, Three Phase—Hardwire
     
    Non-Oscillating Fan
    50"Plastic29,600 ft³/minNot Rated60012 15/165.2 amp to 6.2 amp54"54"17 3/4"DirectGalvanized SteelIP65
    000000000000000
     
    Accessories for Fans

    Premium Beam-Mount Fans

    With a ball-bearing motor and cupped fan blades, these fans last longer and focus airflow better than economy fans. All have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty and dusty environments.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Fans. Premium Beam-Mount Fans.
    Blade
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Cord Lg.,
    ft.
    Drive
    Type
    Guard Material
    For Beam
    Wd.
    Mounting Fasteners
    Included
    Certification
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan
    24"Aluminum5,500 ft³/min61 dB @ 5 ft.1,05031/32.5 amp15DirectChrome-Plated Steel4" to 14"YesUL Listed
    00000000000000
    30"Aluminum8,400 ft³/min65 dB @ 5 ft.1,02531/32.7 amp15DirectChrome-Plated Steel4" to 14"YesUL Listed
    0000000000000
     
    Oscillating Fan
    24"Aluminum5,300 ft³/min61 dB @ 5 ft.1,05031/32.5 amp15DirectChrome-Plated Steel4" to 14"YesUL Listed
    0000000000000
    30"Aluminum7,900 ft³/min65 dB @ 5 ft.1,02531/32.9 amp15DirectChrome-Plated Steel4" to 14"YesUL Listed
    0000000000000
     
    Replacement Power Cords

    Premium Ceiling-Mount Fans

    With a ball-bearing motor and cupped fan blades, these fans last longer and focus airflow better than economy fans. All have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. They also have a totally enclosed motor enclosure, which can be used in dirty and dusty environments. Threaded extension pipe for mounting is not included.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Shown With Extension Pipe (Not Included). Front orientation. Fans. Premium Ceiling-Mount Fans.

    Shown With

    Extension Pipe

    (Not Included)

    Blade
    Mounting
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Cord Lg.,
    ft.
    Drive
    Type
    Guard Material
    Fasteners
    Included
    Hole
    Dia.
    Req. Pipe
    Size
    Certification
    Includes
    Each
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan
    24"Aluminum5,500 ft³/min61 dB @ 5 ft.1,05031/32.5 amp15DirectChrome-Plated SteelNo3/8"1
    UL Listed
    Mounting Bracket00000000000000
    30"Aluminum8,400 ft³/min65 dB @ 5 ft.1,02531/32.7 amp15DirectChrome-Plated SteelNo3/8"1
    UL Listed
    Mounting Bracket0000000000000
     
    Replacement Power Cords

    Ultra-Quiet Low-Profile Ceiling-Mount Fans

    Great for meeting areas, these fans circulate air without drowning out voices. Their low profile maximizes headroom in areas with low clearance.
    Fans with Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Fans. Ultra-Quiet Low-Profile Ceiling-Mount Fans.
    Blade
    Mounting
    Dia.
    Material
    Airflow
    Volume
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Cord Lg.,
    ft.
    Drive
    Type
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    277V AC, Single Phase—Hardwire
     
    Non-Oscillating Fan
    6"Steel2,400 ft³/min57 dB @ 5 ft.1,72511/22.5 ampDirectPolypropyleneYes5/8"00000000000000
     
    208-230/460V AC, Three Phase—Hardwire
     
    Non-Oscillating Fan
    6"Steel2,400 ft³/min57 dB @ 5 ft.1,72511/21.8 amp
    0.9 amp
    DirectPolypropyleneYes5/8"000000000000000
     
    120V AC, Single Phase—Three Blade Plug
     
    Non-Oscillating Fan
    6"Steel2,400 ft³/min57 dB @ 5 ft.1,72511/25.7 amp12DirectPolypropyleneYes5/8"0000000000000
     

    Corrosion-Resistant Belt-Drive Ceiling-Mount Fans

    Image of ProductInUse. Shown Mounted with Chains (Not Included). Front orientation. Fans. Corrosion-Resistant Belt-Drive Ceiling-Mount Fans.

    Shown Mounted with Chains (Not

    Included)

    For rust resistance and durability, these fans have a polyethylene housing. They’re belt-drive fans, so they’re quieter and will last longer than direct-drive fans because their parts can be replaced if worn or damaged.
    Open Dripproof (ODP) Motor Enclosure—Fans with an open-dripproof (ODP) motor enclosure are for indoor locations that are relatively clean and dry.
    Totally Enclosed Motor Enclosure—Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and wet environments.
    Blade
    Overall
    Voltage
    Current
    Dia.
    Material
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Guard
    Material
    Certification
    Each
    Open Dripproof (ODP) Motor Enclosure—Polyethylene Housing
     
    Three Phase—Hardwire
    240V AC
    460V AC
    2.3 amp
    1.1 amp
    34"Aluminum6,90069 dB @ 15 ft.50021/237 5/8"36 1/4"17 5/8"SteelC-ETL Listed, ETL Listed
    0000000000000000
    240V AC
    460V AC
    3.3 amp
    1.5 amp
    40"Aluminum10,60070 dB @ 15 ft.42513/443 5/8"42 1/4"20 5/8"SteelC-ETL Listed, ETL Listed
    000000000000000
    240V AC
    460V AC
    3.8 amp
    1.9 amp
    46"Aluminum14,40069 dB @ 15 ft.3751149 5/8"48 1/4"20 5/8"SteelC-ETL Listed, ETL Listed
    000000000000000
     
    Single Phase—Three Blade Plug
    120V AC8.0 amp34"Aluminum6,90069 dB @ 15 ft.50021/237 3/8"36 1/8"17 5/8"SteelC-ETL Listed, ETL Listed
    000000000000000
    120V AC11.0 amp40"Steel10,60070 dB @ 15 ft.42513/443 3/8"42 1/8"18 3/8"SteelC-ETL Listed, ETL Listed
    000000000000000
    120V AC15.0 amp46"Steel14,40069 dB @ 15 ft.3751149 3/8"48 1/8"20 5/8"SteelC-ETL Listed, ETL Listed
    000000000000000
     
    Totally Enclosed Motor Enclosure—Polyethylene Housing
     
    Single Phase—Hardwire
    120V AC
    240V AC
    7.8 amp
    3.9 amp
    34"Aluminum6,90067 dB @ 15 ft.50021/237 5/8"36 1/4"23"SteelC-ETL Listed, ETL Listed
    000000000000000
    120V AC
    240V AC
    10.8 amp
    5.4 amp
    40"Aluminum10,60070 dB @ 15 ft.42513/443 5/8"42 1/4"23"SteelC-ETL Listed, ETL Listed
    000000000000000
    120V AC
    240V AC
    13.2 amp
    6.6 amp
    46"Aluminum14,40073 dB @ 15 ft.3751149 5/8"48 1/4"23"SteelC-ETL Listed, ETL Listed
    000000000000000
     
    back to top