A rubber seal protects these switches from splashing water.
Prevent accidental actuation—these toggle switches must be pulled up before they can switch a circuit.
The built-in contact block in these switches extends behind the panel half the depth of most other 22 mm switches, saving valuable space.
More durable than standard metal switches, these can handle tough, repetitive use.
The face of these switches mounts flush against a panel, so they're easy to clean and hard to damage.
Immediately cut power with a single push.
These aluminum switches are rated NEMA 4, NEMA 13, and IP66 for protection from washdowns and oil/coolant spraying.
Switches are rated NEMA 4, 13, and IP66.
Rated NEMA 4, 13, and IP66, these metal switches are protected from washdowns and oil/coolant spraying. Install them in 30 mm dia. cutouts.
Install in 16 mm dia. cutouts.
Choose an actuator and contact block to make your own 30 mm switch.
Choose an actuator and contact block to make your own 22 mm metal switch.
Choose an actuator and contact block to make your own 16 mm switch.
With a slim shape, these switches fit comfortably in your hand.
Operate equipment from up to 330 feet away—these switches include a transmitter and a receiver that connects to equipment.
Operate these switches hands-free when working in damp or humid environments.
When the pedal is pressed, the built-in potentiometer adjusts the resistance to vary the speed for motor drives.
Rated NEMA 4, these switches are protected from washdowns.
These 16 mm switches require a key to turn circuits on or off, limiting access to sensitive equipment.
Pull the hanging rope in any direction to actuate these switches.
Immediately cut power by pulling the cable.
Rated NEMA 4 , these enclosed switches have a sealed actuator for protection from washdowns.
Stack these slim switches together, or fit them into tight spaces. They're rated IP67 for protection from temporary submersion.
Sealed actuators prevent these switches from jamming, even when exposed to sand, mud, or dirt. They're rated IP67 for protection from temporary submersion.
Shorter and thinner than other safety limit switches, these are sized to fit tight spaces.
Protect machinery and ensure the safety of personnel—these switches will open the circuit when actuated even if a spring fails or the contacts stick.
Often used with machine guards, these switches mount to a door frame.
Often used as position indicators, pump level controls, and machine limit switches, these switches actuate when tilted to a certain angle.
Assemble your own motor starter by combining a switch and a thermal overload element.
Rated NEMA 4, these controls are protected from washdowns.
Set to actuate at a specific temperature, these switches are easy to setup and prevent changes to the setpoint. They have a threaded probe, so they install directly into tanks, pipelines, and other process components to turn equipment on and off at a set temperature.
With a round body that’s at least one-third thinner than traditional pressure switches, these fit in tight, cramped spaces.
The traditional pressure switch. These power equipment, activate controls or alarms, or kick-off other actions when they reach a set pressure.
Prevent changes to the set pressure that activates equipment—these switches come ready to use at your preferred setpoint.
Built with an explosionproof enclosure to meet NEMA 7 and 9 standards for hazardous locations, these switches were tested and verified by UL and CSA for use where explosive liquids, dust, and gas are present.
Cleaned to ASTM G93 requirements and then bagged, these switches meet the strict cleaning standards required for oxygen service lines.
Often built into pumps and hydraulic systems with limited space, these compact switches power equipment, activate controls, and signal alarms when they reach a set vacuum.
Prevent changes to the set vacuum that powers equipment, activates controls, or signals alarms. The setpoint on these switches isn't adjustable.
Detect the difference in pressure between two points. For instance, these switches can indicate a filter is clogged in a pump or cooling system.
Control one- and two-speed heaters and air conditioners.
For use in locations with flammable gases and combustible dust, this switch is UL listed and CSA certified for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G.
These switches are CSA certified for hazardous locations.
Designed for use in areas where flammable substances are present, these switches are CSA certified for hazardous locations.
UL listed for use where flammable gases or combustible dusts may be present, these flow switches activate or deactivate equipment when your flow rate reaches a set point.
Safe to use where flammable gases and combustible dust may be present, these switches activate or deactivate when your flow reaches a factory-set level. All are UL listed for hazardous environments.
Safely activate and deactivate equipment in environments with flammable gases and combustible dust when your flow rate reaches a set point. These switches save you from disassembling your pipeline because you insert them into pipe tees or pipe outlets instead of mounting them inline.
Get NEMA 4 and IP66 protection from dirt and water. If vibration or shock exceeds a set activation point, the contacts actuate to either shut down your machine or activate an alarm.
Build out human-machine interfaces by installing buttons, switches, gauges, and other components to monitor and control machinery.
Direct flow with an electronic signal.