    37 Products

    Hazardous Location Enclosed Motor Switches

    Image of Product. Front orientation. Motor Switches. Hazardous Location Enclosed Motor Switches.
    Safely turn motors on and off near ignitable gases and dust—the housing on these switches seals in anything that could ignite flammable material. Made from aluminum, the housing is lightweight and durable. It guards against water, oil, and other materials that could cause damage. Even in harsh conditions, there’s no need to mount these switches inside an electrical panel.
    You need to grip and twist the lever to actuate these switches, so they won’t accidentally turn on or off if something bumps into them. In addition to starting and stopping motors, they work with other circuits, such as lighting and electric heat circuits. They don’t provide overload protection.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Housing
    Material
    Ht.
    Wd.
    Wire
    Connection
    Environment
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Each
    Maintained
     
    Lever Actuator
    2Single (3 hp @ 240V AC)2 Off
    DPST-NO
    30600Painted Aluminum6.5"3"Screw TerminalHazardousNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7, NEMA 9
    UL Listed, C-UL Listed, CSA Certified
    7657K320000000
    3Three (7 1/2 hp @ 240V AC)3 Off
    3PST-NO
    30600Painted Aluminum6.5"3"Screw TerminalHazardousNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7, NEMA 9
    UL Listed, C-UL Listed, CSA Certified
    7657K22000000
     

    Hazardous Location Enclosed Push-Button Switches

    Image of Product. Front orientation. Push-Button Switches. Hazardous Location Enclosed Push-Button Switches, 1 Flush Push Button and 1 Projecting Push Button.

    1 Flush Push

    Button and 1

    Projecting Push

    Button

    Use these switches where ignitable gas and dust may be present. They're rated for use in hazardous locations.
    Mounting
    Message (Actuator Color)
    No. of Circuits
    Controlled per Button
    Switch Starting
    Position
    Switch
    Action
    No. of Terminals
    per Button
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage,
    V AC
    Conduit
    Trade Size
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Enclosure Rating
    Each
    Aluminum Housing with Screw-Terminal Wire Connection
     
    1 Flush Push Button and 1 Projecting Push Button
    Start (Green), Stop (Red),21 Off and 1 On
    Momentary
    2DPST-1NO/1NC
    10 amp @ 120V AC6003/4
    No29/32"NEMA 3, NEMA 7, NEMA 9
    6883K550000000
     

    Speed-Monitoring Switches

    Image of System. Front orientation. Contains Annotated. Speed-Monitoring Switches. Speed-Monitoring Switches.
    Image of Product. Front orientation. Contains Annotated. Speed-Monitoring Switches. Speed-Monitoring Switches.
    Detect unwanted slowdowns in a rotary shaft that could cause machine damage and downtime. These switches are often used on drivetrains, conveyors, and other power-driven components. They come with a pulser disc, which you’ll need to attach to the shaft by drilling and tapping a hole. Once mounted, the disc rotates with the shaft and creates magnetic signals that the switch senses. When the speed falls below a set point, the switch will trigger an alarm or turn off the system.
    Switches are UL listed and rated NEC Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. They have an explosion-proof housing and are also rated NEMA 4X for washdown and corrosion protection.
    Switching
    Input
    Conduit
    Mounting
    Slot
    Activation
    Point Range, rpm
    Current,
    amp
    Voltage,
    V AC
    Voltage,
    V AC
    Freq.,
    Hz
    No. of
    Terminals
    Trade
    Size
    Thread
    Type
    Gender
    Lg.
    Wd.
    No.
    of
    Lg.
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Housing
    Material
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    1 Off (Normally Open), 1 On (Normally Closed) Starting Switch Position
     
    SPDT
    5 to 10051201206051
    NPT
    Female1 1/4"0.32"24.4"3.7"4.8"YesAluminum
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 4X
    6177K110000000
     

    Hazardous Location Vibration Switches

    Image of Product. Front orientation. Contains Annotated. Vibration Switches. Hazardous Location Vibration Switches.
    Get NEMA 4 and IP66 protection from dirt and water. These switches are rated for hazardous locations for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. If vibration or shock exceeds a set activation point, the contacts actuate to either shut down your machine or activate an alarm. Reset the switch with the push of a button. The activation point is adjustable between 0 to 5 gravity units (g) at 0 to 60 Hz.
    Activation
    Point
    Switching
    Housing
    Conduit
    Mounting
    Slot
    Range,
    g
    Freq. Range,
    Hz
    Current,
    amp
    Voltage, V AC
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Trade
    Size
    Thread
    Type
    Gender
    Mounting Fasteners
    Included
    No. of Mounting
    Holes
    Lg.
    Wd.
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Each
    1 Off or 1 On Switch Starting Position
     
    SPDT
    0 to 50 to 6015125
    480
    4.2"4 3/4"6"-40 to 1553/4
    NPT
    FemaleNo43/4"3/8"NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    IP66
    NEMA 4
    UL Listed, C-UL Listed, CSA-US Certified, CSA Certified, CE Marked
    1188T310000000
     

    Hazardous Location Differential Pressure Switches for Air

    Image of Product. Front orientation. Differential Pressure Switches.
    With an explosion-proof enclosure that meets NEMA 7 and 9 standards for hazardous locations, these switches were tested and verified by UL for use where explosive gas or dust may be present. Often used with ovens, dryers, and HVAC systems, they can indicate a filter is clogged or help maintain a certain air pressure. These switches turn equipment on and off, activate automated controls, or signal alarms when the differential pressure reaches your setpoint. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on or from on to off.
    In addition to being UL listed, these switches are CE marked and FM approved, so they also meet European safety standards. They also are IP and NEMA rated for use outdoors and protect against dust and splashing water.
    When measuring pressure in ductwork, pair them with a static pressure probe.
    Pressure Set Point Range
    Approx. Difference Between Set
    Point and Reset Point
    Max. Input
    Pressure
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use
    With
    Enclosure Rating
    Hazardous Location Rating
    Each
    Screw-Terminal Wire Connection
     
    1/8 NPT Female Pipe Connection
    0.07 in. H₂O to 0.15 in. H₂O0.13 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N110000000
    0.15 in. H₂O to 0.5 in. H₂O0.05 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N12000000
    0.4 in. H₂O to 1.6 in. H₂O0.18 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N13000000
    1.4 in. H₂O to 5.5 in. H₂O0.35 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N14000000
    3 in. H₂O to 11 in. H₂O0.45 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N15000000
    4 in. H₂O to 20 in. H₂O0.5 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N16000000
    0.5 psi to 2 psi0.3 psi35 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N17000000
    1.5 psi to 8 psi1 psi35 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    0 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N18000000
    3 psi to 15 psi0.9 psi35 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    0 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N19000000
    4 psi to 25 psi0.7 psi35 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    0 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N21000000
    15 psi to 50 psi1.25 psi70 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    0 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N22000000
     

    Paddle Level Switches for Dry Materials

    Image of Product. Front orientation. Contains Annotated. Paddle Level Switches. Horizontal Mount.
    Image of Product. Front orientation. Contains Annotated. Paddle Level Switches. Vertical Mount.

    Horizontal Mount

    Vertical Mount

    Monitor the level of dry material in surge bins, tanks, and silos to avoid overspills and outages. With a long paddle, these switches extend farther into large storage containers to detect material levels where other types of switches can’t reach. You can even adjust the paddle's sensitivity to materials of different sizes and shapes, such as powders, plastic pellets, and wood chips. Install multiple switches on the same container to monitor levels at various points. They are rated NEMA 4X and IP66 for protection from corrosion and washdowns.
    Horizontal Mount—Commonly installed near the bottom of containers to indicate low levels as material flows out. These switches start to rotate when material falls low enough to uncover the paddle, triggering a conveyor, pump, or other piece of equipment to prevent the container from emptying.
    Vertical Mount—Mount to the roof of containers to indicate high levels when loading material. For domed roofs, you can extend these switches farther down by connecting the paddle to your desired length of 1/8 NPT Schedule 40 pipe. The paddle rotates freely until material rises to its level and stops it, triggering a conveyor, pump, or other piece of equipment to prevent overfilling.
    With Alarm—Switches with an alarm alert you to potential malfunctions before they occur. They continuously perform self-diagnostics to detect everything from motor failure to seized bearings. When they detect an error, an LED light flashes in a corresponding code, so maintenance workers will immediately know which problem they need to fix.
    Paddle
    Switch
    Insertion
    Dp.
    Material Wt. Cap.
    Range, lb/ft³
    Max. Pressure
    @ Temp.
    Speed,
    rpm
    Lg.
    Wd.
    Material
    Starting
    Position
    Designation
    Current @
    Voltage
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Horizontal Mount
     
    Without Alarm
    6 5/8"3.4 to 3030 psi @ 70° F17"2"316 Stainless Steel
    1 Off or 1 On
    SPDT
    20 amp @ 120V ACIP66
    NEMA 4X
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    UL Listed
    C-UL Listed
    49005K510000000
     
    With Alarm
    6 5/8"3.4 to 3030 psi @ 70° F17"2"316 Stainless Steel
    1 Off or 1 On
    SPDT
    8 amp @ 120V ACIP66
    NEMA 4X
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    UL Listed
    C-UL Listed
    49005K26000000
     
    Vertical Mount
     
    Without Alarm
    12"30 to 7030 psi @ 70° F15"1 1/2"316 Stainless Steel
    1 Off or 1 On
    SPDT
    20 amp @ 120V ACIP66
    NEMA 4X
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    UL Listed
    C-UL Listed
    49005K52000000
     
    With Alarm
    12"30 to 7030 psi @ 70° F15"1 1/2"316 Stainless Steel
    1 Off or 1 On
    SPDT
    8 amp @ 120V ACIP66
    NEMA 4X
    NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    UL Listed
    C-UL Listed
    49005K36000000
     
    Replacements for Paddle Level Switches

    Vertical-Mount Hazardous Location Float Switches for Fuels and Oils

    Image of Product. Front orientation. Contains Annotated. Float Switches. Vertical-Mount Hazardous Location Float Switches for Fuels and Oils.
    For use in locations with flammable gases and combustible dust, these switches are UL listed and CSA certified for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. Mount them vertically through the top of your tank. They're rated NEMA 4 for protection from washdowns.
    Pipe
    Float
    Conduit
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Mounting
    Location
    Lg.
    Dia.
    Electrical
    Connection
    Trade
    Size
    Thread
    Type
    Gender
    Certification
    Each
    120V AC/240V AC Input Voltage
     
    316 Stainless Steel Body and Float
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2759 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    4914K97000000000
     

    Hazardous-Location Insertion-Mount Flow Switches

    Image of Product. Front orientation. Contains Annotated. Flow Switches. Hazardous-Location Insertion-Mount Flow Switches.
    Safely activate and deactivate equipment in environments with flammable gases and combustible dust when your flow rate reaches a set point. They are UL listed and CSA certified for use in hazardous locations. These switches save you from disassembling your pipeline because you insert them into pipe tees or pipe outlets instead of mounting them inline. They actuate when your system’s liquid pushes the paddle into a set position. To change your set point, the paddle has multiple layers that you can remove. For the lowest set point, use the largest paddle that will fit your pipe. To increase your set point, loosen the locking washers and remove paddles. You can trim the paddles to fine-tune your set point. The smaller the paddle, the higher the setpoint.
    They should be mounted vertically into a horizontal pipeline, so liquid pushes the paddle.
    These switches are calibrated with water and air. They can also be used with other liquids and gases but may not measure accurately if their viscosity is significantly different.
    SPDT—SPDT (singe pole, double throw) switches can turn one device from off to on (normally open) or from on to off (normally closed).
    DPDT—DPDT (double pole, double throw) switches can either turn two devices from off to on (normally open) or on to off (normally closed).
    Flow Set Point Range
    Max. Flow Rate
    Conduit
    Pipe
    Size
    Thread
    Type
    Gender
    For Pipe
    Size
    For Water and Oil
    For Air and Inert Gas
    For Water
    and Oil
    For Air and
    Inert Gas
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current
    @ Voltage
    Trade
    Size
    Thread
    Type
    Gender
    Body
    Ht.
    Each
    SPDT
     
    Brass Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated1,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K530000000
     
    316 Stainless Steel Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated2,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K5500000000
     
    DPDT
     
    Brass Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated1,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K54000000
     
    316 Stainless Steel Body
    1 1/2
    NPT
    Male1 1/2
    2
    4
    12
    20
    3 gpm to 7 gpm
    4 gpm to 15 gpm
    12 gpm to 95 gpm
    140 gpm to 900 gpm
    400 gpm to 2,400 gpm
    17 scfm to 32 scfm
    13 scfm to 65 scfm
    50 scfm to 400 scfm
    800 scfm to 3,450 scfm
    2,850 scfm to 10,000 scfm
    55 gpm
    97 gpm
    391 gpm
    3,525 gpm
    9,792 gpm
    Not Rated2,000 psi @ 70° F-4 to 2755 amp @ 125V AC
    5 amp @ 250V AC
    3/4
    NPT
    Female8"48005K5600000000
     

    Hazardous Location Float Switches for Water

    Image of Product. Front orientation. Contains Annotated. Float Switches. Hazardous Location Float Switches for Water.
    For use in locations with flammable gases and combustible dust, these switch are UL listed and CSA certified for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G. Mount them vertically through the top of your tank. They're rated NEMA 4 for protection from washdowns.
    Pipe
    Float
    Conduit
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Mounting
    Location
    Lg.
    Dia.
    Electrical
    Connection
    Trade
    Size
    Thread
    Type
    Gender
    Certification
    Each
    120V AC/240V AC Input Voltage
     
    Brass Body and 316 Stainless Steel Float
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2755 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    5363N130000000
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2757 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    5363N16000000
    1 1/2
    NPT
    Male0.7100 psi @ 70° F35 to 2759 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    4914K96000000
    2
    NPT
    Male0.7100 psi @ 70° F35 to 2759 1/4"1 Off or 1 On
    SPDT
    10 amp @ 120V ACTop4 1/2"1 5/8"Wire Leads3/4
    NPT
    FemaleUL Listed, CSA Certified, FM Approved
    5363N11000000
     

    Hazardous Location Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Hazardous Location Line-Voltage Thermostats.
    Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present.
    Hazardous Location Rating—Thermostats are rated Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G.
    Cannot Be Sold To—Energy efficiency requirements restrict sales to the listed jurisdictions/areas.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Display
    Type
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Cannot Be
    Sold To
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    24 to 2772250 to 90SPDT
    Hardwire5 3/4"6 3/8"5 5/8"NoNo1/4"AnalogNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7
    CSA Certified, UL Listed
    Colorado1877K230000000
    24 to 2772250 to 90DPDT
    Hardwire5 3/4"6 3/8"5 5/8"NoNo1/4"AnalogNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7
    CSA Certified, UL Listed
    Colorado1877K25000000
     

    Hazardous Location Float Switches for Chemicals

    Image of Product. Style B. Front orientation. Float Switches. Hazardous Location Float Switches for Chemicals, 316 Stainless Steel Body and Float, Style B.
    Image of Attribute. Front orientation. Contains Annotated. Hazardous Location Float Switches for Chemicals.

    Style B

    Designed for use in areas where flammable substances are present, these switches are CSA certified for hazardous locations. Mount them through a tank wall.
    Style B—Style B meet Class I, Divisions 1 and 2, Groups C and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2.
    Pipe
    Conduit
    Style
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Electrical
    Connection
    Trade
    Size
    Thread
    Type
    Gender
    Certification
    Each
    120V AC/240V AC Input Voltage
     
    316 Stainless Steel Body and Float
    B1 1/2
    NPT
    Male0.41,500 psi @ 70° F0 to 3003 1/4"1 Off/1 On
    SPST-NO
    SPST-NC
    0.83 amp @ 120V ACWire Leads1/2
    NPT
    MaleCSA Certified, FM Approved
    5300K550000000
    B2
    NPT
    Male0.41,500 psi @ 70° F0 to 3003 1/4"1 Off/1 On
    SPST-NO
    SPST-NC
    0.83 amp @ 120V ACWire Leads1/2
    NPT
    MaleCSA Certified, FM Approved
    5300K58000000
     

    Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils

    Image of Product. Style C. Front orientation. Style C. Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils.
    Image of Attribute. Front orientation. Contains Annotated. Horizontal-Mount Hazardous Location Float Switches for Fuels and Oils.

    Style C

    Designed for use in areas where flammable substances are present, these switches are CSA certified for hazardous locations. Mount them through a tank wall. All are rated NEMA 4 for protection from washdowns. All are single pole, double throw (SPDT) and can be installed to turn one circuit from “off” to “on” or from “on” to “off”.
    Switches with a stainless steel body are more corrosion resistant than switches with a brass body.
    Pipe
    Conduit
    Style
    Size
    Thread
    Type
    Gender
    Min. Specific
    Gravity
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Current @
    Voltage
    Float Material
    Trade
    Size
    Thread
    Type
    Gender
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    120V AC/240V AC Input Voltage
     
    Brass Body
    C1 1/2
    NPT
    Male0.7100 psi @ 70° F0 to 27513 3/16"10 amp @ 120V AC316 Stainless Steel
    3/4
    NPT
    FemaleNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    IP56
    NEMA 4
    4914K860000000
     
    316 Stainless Steel Body
    C1 1/2
    NPT
    Male0.7100 psi @ 70° F0 to 27513 3/16"10 amp @ 120V AC316 Stainless Steel
    3/4
    NPT
    FemaleNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    IP56
    NEMA 4
    4914K8700000000
     