Actuator Style Actuator Style |
---|
![]() | ![]() |
Push Button | Toggle |
![]() | ![]() |
Rocker | Key |
Illumination Illumination |
---|
|
Wire Connection Type Wire Connection Type |
---|
![]() | ![]() |
Screw Terminals | Wire Leads |
Mounting Location Mounting Location | Show |
---|
|
Mounting Location Mounting Location | Hide |
---|
Switch Action Switch Action |
---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Reset Type Reset Type |
---|
|
Push-Button Style Push-Button Style |
---|
![]() | Mushroom |
Switch Starting Position Switch Starting Position |
---|
System of Measurement System of Measurement |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
Choosing an Electrical Switch
More
Outlet-Box-Mount Push-Button Switches


Also known as palm-button switches, these have a large button that makes them easy to use even while wearing gloves. They're rated NEMA 13 and IP65 for protection from oil/coolant spraying and washdowns.
Switches with positive force contacts will open a circuit when actuated even if a spring fails or the contacts stick.
Ring guards (sold separately) protect the actuator and reduce the chance of accidental actuation.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Cover Color | Switching Current @ Voltage | Max. Voltage | Dia. | Environmental Rating | Each | |
Metal Actuator with Screw Terminals and Positive Force Contacts | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Chrome | Black | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 0000000 |
Plastic Actuator with Screw Terminals | ||||||||||||
2 | 2 Off (Normally Open) | Springs Back (Momentary) | 4 | DPST-NO | Black | Black | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
2 | 2 Off (Normally Open) | Springs Back (Momentary) | 4 | DPST-NO | Red | Black | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
2 | 2 Off (Normally Open) | Springs Back (Momentary) | 4 | DPST-NO | Yellow | Black | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
Plastic Actuator with Screw Terminals and Positive Force Contacts | ||||||||||||
1 | 1 On (Normally Closed) | Springs Back (Momentary) | 2 | SPST-NC | Red | Yellow | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
1 | 1 On (Normally Closed) | Springs Back (Momentary) | 2 | SPST-NC | Yellow | Black | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Black | Black | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Green | Black | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Red | Yellow | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | Yellow | Black | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
2 | 2 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-NC | Red | Yellow | 6 A @ 120 V AC, 2.2 A @ 120 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | 0000000 | 000000 |
Emergency Stop Outlet-Box-Mount Push-Button Switches

Immediately cut power with a single push. The large palm-sized buttons on these switches provide an easy target, so they're easy to use even while wearing gloves. When the button is depressed, the switch latches and can be locked in that position using a lockout or padlock with a 9/32” shackle diameter (not included). All have positive force contacts that will open the circuit when actuated even if a spring fails or the contacts stick. They're rated NEMA 13 and IP65 for protection from oil/coolant spraying and washdowns.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Cover Color | Switching Current @ Voltage | Max. Voltage | Dia. | Environmental Rating | Specifications Met | Each | |
Plastic Actuator with Screw Terminals | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | Red | Yellow | 6 A @ 120 V AC, 2.2 A @ 125 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | UL Listed, CSA Certified, CSA-US Certified, CE Marked, UL 508, EN 60947-5-5, IEC 60947-5-5 | 00000000 | 0000000 |
Outlet-Box-Mount Key Switches

Reset fire panels, or open electromagnetic locks, electric strikes, and automatic door openers. These switches require a key to turn circuits on or off, limiting access and preventing accidental activation. The lock is not included; use a 1 1/4" long mortise lock with a standard cam.
Switches with a delayed start timer allow personnel to reach a door before it opens.
For technical drawings and 3-D models, click on a part number.
Wire Leads | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | No. of | Lg. | Includes | Each | |
2 Position | ||||||||||||
With Wire Leads | ||||||||||||
2 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | 3 | SPDT | 3 A @ 125 V AC, 1 A @ 250 V AC | 250V AC | 1 3/16" | 3 | 5" | Screwdriver, Tamper-Resistant Screws | 00000000 | 0000000 |
2 | 1 Off (Normally Open) or 1 On (Normally Closed) | Stays Switched (Maintained) | 3 | SPDT | 3 A @ 125 V AC, 1 A @ 250 V AC | 250V AC | 1 3/16" | 3 | 5" | Screwdriver, Tamper-Resistant Screws | 00000000 | 000000 |
2 Position with Delayed Start Timer | ||||||||||||
With Wire Leads | ||||||||||||
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | 10 A @ 125 V AC/250 V AC | 250V AC | 1 3/16" | 4 | 5" | Screwdriver, Tamper-Resistant Screws | 00000000 | 000000 |
High-Amp Outlet-Box-Mount Key Switches

Able to withstand high currents, these switches can be used with motors and pumps. They require a key to turn circuits on or off, limiting access to sensitive equipment. All are keyed alike, so they open with the same key.
For technical drawings and 3-D models, click on a part number.
Key | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Horsepower @ Switching Voltage | Dia. | No. of Keys Included | Keying | Removal Position | Each | |
2 Position with Metal Base | |||||||||||||
Keyed Alike with Screw Terminals | |||||||||||||
2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | 20 A @ 120 V AC | 277V AC | 1 hp @ 120 V AC | 7/8" | 2 | Keyed Alike | Center | 000000 | 0000000 |
Toggle Light Switches
Use these toggle switches to control lighting. They also work with AC motor loads up to 80% of the current rating. All fit standard wall plates (not included).
Wall switch lockouts (sold separately) mount over switches to secure them in the on or off position.
For technical drawings and 3-D models, click on a part number.

No. of Circuits Controlled | No. of Terminals | Switch Action | Switching Current @ Voltage | Wire Connection Type | Terminal Location | Choose a Color | Each | |
Not Illuminated | ||||||||
---|---|---|---|---|---|---|---|---|
1 | 2 | Stays Switched (Maintained) | 15 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 000000 | |
1 | 2 | Stays Switched (Maintained) | 20 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 00000 | |
1 | 2 | Stays Switched (Maintained) | 30 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 00000 | |
2 | 4 | Stays Switched (Maintained) | 15 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 00000 | |
2 | 4 | Stays Switched (Maintained) | 20 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 00000 | |
2 | 4 | Stays Switched (Maintained) | 30 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 00000 | |
Illuminated | ||||||||
1 | 2 | Stays Switched (Maintained) | 15 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | Ivory | 0000000 | 00000 |
1 | 2 | Stays Switched (Maintained) | 15 A @ 120 V AC | Screw Terminals | Back, Side | Clear | 0000000 | 00000 |
1 | 2 | Stays Switched (Maintained) | 20 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | Ivory | 0000000 | 00000 |
1 | 2 | Stays Switched (Maintained) | 20 A @ 120 V AC | Screw Terminals | Back, Side | Clear | 0000000 | 00000 |

Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Lg. | Wd. | Dp. | Color | Language | Message | Each | |
1 | 9/32" | 4 3/4" | 1 3/4" | 1" | Red | English/Spanish, English/French | Danger—Locked Out Do Not Remove, Peligro—Cerrado No Lo Quite, Danger—Locked Out Do Not Remove, Danger—Verrouille Ne Pas Enlever | 00000000 | 000000 |
Multi-Way Toggle Light Switches
Often used in large, open workspaces, these switches can be wired on opposite ends of the room to control lights on the same circuit. These switches fit standard wall plates (not included).
Three-way switches work in pairs to control lights from two different locations.
Use a four-way switch with two three-way switches to control lights from three different locations.
Wall switch lockouts (sold separately) mount over switches to secure them in the on or off position.
For technical drawings and 3-D models, click on a part number.

No. of Circuits Controlled | No. of Terminals | Switch Action | Switching Current @ Voltage | Wire Connection Type | Terminal Location | Choose a Color | Each | |
3 Way | ||||||||
---|---|---|---|---|---|---|---|---|
1 | 3 | Stays Switched (Maintained) | 15 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 000000 | |
1 | 3 | Stays Switched (Maintained) | 20 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 00000 | |
1 | 3 | Stays Switched (Maintained) | 30 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 00000 | |
4 Way | ||||||||
1 | 4 | Stays Switched (Maintained) | 20 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 00000 |

Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Lg. | Wd. | Dp. | Color | Language | Message | Each | |
1 | 9/32" | 4 3/4" | 1 3/4" | 1" | Red | English/Spanish, English/French | Danger—Locked Out Do Not Remove, Peligro—Cerrado No Lo Quite, Danger—Locked Out Do Not Remove, Danger—Verrouille Ne Pas Enlever | 00000000 | 000000 |
Rocker Light Switches
Use these rocker switches to control lighting. They also work with AC motor loads up to 80% of the current rating. All fit standard wall plates (not included).
Wall switch lockouts (sold separately) mount over switches to secure them in the on or off position.
For technical drawings and 3-D models, click on a part number.

No. of Circuits Controlled | No. of Terminals | Switch Action | Switching Current @ Voltage | Wire Connection Type | Terminal Location | Choose a Color | Each | |
1 | 2 | Stays Switched (Maintained) | 15 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 000000 | |
1 | 2 | Stays Switched (Maintained) | 20 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 00000 |
Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Lg. | Wd. | Dp. | Color | Language | Message | Each | |
1 | 9/32" | 4 3/4" | 1 3/4" | 1" | Red | English/Spanish, English/French | Danger—Locked Out Do Not Remove, Peligro—Cerrado No Lo Quite, Danger—Locked Out Do Not Remove, Danger—Verrouille Ne Pas Enlever | 00000000 | 000000 |
Multi-Way Rocker Light Switches
Also known as three-way switches, these are often used in large, open workspaces and can be wired on opposite ends of the room to control lights on the same circuit. They work in pairs to control lights from two different locations. All fit standard wall plates (not included).
Wall switch lockouts (sold separately) mount over switches to secure them in the on or off position.
For technical drawings and 3-D models, click on a part number.

No. of Circuits Controlled | No. of Terminals | Switch Action | Switching Current @ Voltage | Wire Connection Type | Terminal Location | Choose a Color | Each | |
3 Way | ||||||||
---|---|---|---|---|---|---|---|---|
1 | 3 | Stays Switched (Maintained) | 15 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 000000 | |
1 | 3 | Stays Switched (Maintained) | 20 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 00000 |
Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Lg. | Wd. | Dp. | Color | Language | Message | Each | |
1 | 9/32" | 4 3/4" | 1 3/4" | 1" | Red | English/Spanish, English/French | Danger—Locked Out Do Not Remove, Peligro—Cerrado No Lo Quite, Danger—Locked Out Do Not Remove, Danger—Verrouille Ne Pas Enlever | 00000000 | 000000 |
Key-Actuated Light Switches

Prevent accidental activation—these switches require a key to turn lights on and off. They’re keyed alike, so all switches actuate with the same key. They also work with AC motor loads up to 80% of the current rating. All fit standard wall plates (not included).
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Color | Key Removal Position | No. of Keys Included | No. of Terminals | Switch Action | Switching Current @ Voltage | Wire Connection Type | Terminal Location | Each | |
1 | Gray | Off, On | 1 | 2 | Stays Switched (Maintained) | 15 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 000000 |
1 | Gray | Off, On | 1 | 2 | Stays Switched (Maintained) | 20 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 00000 |
Replacement Key | 0000000 | Each | 00000 |
Multi-Way Key-Actuated Light Switches

Also known as three-way switches, these are often used in large, open workspaces and can be wired on opposite ends of the room to control lights on the same circuit. They work in pairs to control lights from two different locations. To prevent accidental activation, they require a key to turn lights on and off. They’re keyed alike, so all switches actuate with the same key. They also work with AC motor loads up to 80% of the current rating. All fit standard wall plates (not included).
For technical drawings and 3-D models, click on a part number.
Multi-Way Switch Type | No. of Circuits Controlled | Color | Key Removal Position | No. of Keys Included | No. of Terminals | Switch Action | Switching Current @ Voltage | Wire Connection Type | Terminal Location | Each | |
3 Way | 1 | Gray | Off, On | 1 | 3 | Stays Switched (Maintained) | 20 A @ 120 V AC/277 V AC | Screw Terminals | Back, Side | 0000000 | 000000 |
Replacement Key | 0000000 | Each | 00000 |
High-Security Key-Actuated Light Switches

Secure sensitive lighting equipment; these switches have a round key that is difficult to duplicate. The key is required to turn lights on and off. They’re keyed alike, so all switches actuate with the same key. They also work with AC motor loads up to 80% of the current rating.
Light-Sensing Light Controls
Automatically turn outdoor lights on after dark and off at daybreak, conserving energy when lights are not needed. A time delay prevents false switches due to light flashes.
Outlet-box- and panel-mount controls are flush when mounted.

No. of Circuits Controlled | Input Voltage | Wattage | Includes | Housing Material | Ht. | Wd. | Dp. | Wire Lead Lg. | Specifications Met | Each | |
1 | 120V AC | 2,000W | Aluminum Wall Plate | Plastic | 2" | 1" | 1 1/2" | 6" | UL Listed, CSA Certified | 0000000 | 000000 |
Humidistats

Turn the dial to control humidity equipment.
Humidistats for humidifiers and dehumidifiers mount to a surface-mount outlet box.
Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current | Relative Humidity | Switch Type | Color | Ht. | Wd. | Dp. | Mounting Location | Mounting Fasteners Included | Each | |
For Humidifiers and Dehumidifiers | |||||||||||
120V AC/208V AC/240V AC | 6A/3.5A/3A | 0-70% | SPDT | Beige | 4 3/4" | 3" | 3" | Outlet Box | Yes | 0000000 | 0000000 |
Remote Test Stations for Smoke Detectors for HVAC Systems

Check that your HVAC smoke detector is working properly. Wire these test stations to your smoke detector controller to test difficult to access smoke detectors from a convenient location. Indicator lights show if your smoke detector is powered on, if it senses smoke, and if its sensors are too dirty to detect smoke and need cleaning. These test stations activate with the turn of a key so you don’t turn them on by accident.
Actuator Style | Switch Starting Position | No. of Terminals | Industry Designation | Voltage | Temp. Range, °F | Wire Connection Type | Wd. | Ht. | Mounting Hardware Included | Specifications Met | Each | |
Key | 1 Off (Normally Open) | 5 | SPST-NO | 24V AC, 24V DC, 120V AC, 230V AC | 32° to 130° | Screw Terminals | 3" | 4 3/4" | Yes | C-UL Listed, FM Approved, UL Listed | 0000000 | 000000 |