    Mil. Spec. Washdown Toggle Switches

    Image of Product. Front orientation. Toggle Switches. Mil. Spec. Washdown Toggle Switches .
    These switches meet MIL-S-3950. A rubber seal protects them from washdowns.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Dp. Behind
    Panel
    Mounting Hardware
    Included
    Wire
    Connection
    Each
    2 Positions
     
    For 1/2" Diameter Panel Cutouts
    44 Off
    Maintained
    84PST
    On-Off
    15 amp @ 125V AC, 12 amp @ 28V DC28V DC
    125V AC
    1.35"YesScrew Terminal8002K134000000
     

    Panel-Mount Compact Disconnect Switches

    Install these switches in a panel cutout. Small enough to fit in tight spaces, they handle comparable electrical loads to standard sized switches. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Panel-Mount Compact Disconnect Switches.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP65 Enclosure Rating—They’re rated IP65 for protection from washdowns.
    Switching Current @ Voltage
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Gray Plastic Housing with Black Actuator
     
    4 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC4PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K107000000
    16 amp @ 600V AC, 20 amp @ 24V DC4PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10800000
    20 amp @ 600V AC, 25 amp @ 24V DC4PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10900000
    25 amp @ 600V AC, 32 amp @ 24V DC4PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K111000000
    50 amp @ 600V AC, 50 amp @ 24V DC4PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K112000000
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K113000000
     
    Yellow Plastic Housing with Red Actuator
     
    4 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC4PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4100000
    16 amp @ 600V AC, 20 amp @ 24V DC4PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4200000
    20 amp @ 600V AC, 25 amp @ 24V DC4PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4300000
    25 amp @ 600V AC, 32 amp @ 24V DC4PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K44000000
    50 amp @ 600V AC, 50 amp @ 24V DC4PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K45000000
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K46000000
     

    Enclosed Compact Disconnect Switches

    Small yet mighty, these switches are about as tall and wide as an index card yet durable enough to mount directly to a wall. Don’t be fooled by their size—these switches can handle electrical loads comparable to a standard sized switch.
    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Enclosed Compact Disconnect Switches.
    Plastic Housing—Their plastic housing protects the switch and resists denting, chipping, and cracking.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP65 Enclosure Rating—Rated IP65, the housing also seals out water even in frequently washed down areas.
    Switching Current @ Voltage
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Enclosure
    Rating
    Certification
    Each
    Yellow Plastic Housing with Red Actuator
     
    4 Circuits Controlled with Lockout
    12 amp @ 600V AC, 16 amp @ 24V DC4PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K340000000
    16 amp @ 600V AC, 20 amp @ 24V DC4PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K35000000
    20 amp @ 600V AC, 25 amp @ 24V DC4PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K36000000
    25 amp @ 600V AC, 32 amp @ 24V DC4PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K37000000
    50 amp @ 600V AC, 50 amp @ 24V DC4PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K38000000
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K39000000
     

    DIN-Rail Mount Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. DIN-Rail Mount Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. DIN-Rail Mount Disconnect Switches.
    Image of Product. Front orientation. Disconnect Switches. DIN-Rail Mount Disconnect Switches.

    Power Pole

    Neutral Pole

    Often used in electrical enclosures, these switches mount directly to DIN rails. They cut power and keep it isolated to stop equipment from starting up during inspection and maintenance. For an extra level of security, add a padlock (not included) to lock out the actuator lever in the Off position.
    Use additional switch power poles to control additional circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Maintained SwitchAbout Maintained Switch
    Switching
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    For DIN
    Rail Ht., mm
    Wire
    Connection
    Certification
    Specs.
    Met
    Each
    Gray Plastic Housing with Black Actuator
     
    4 Circuits Controlled with Lockout
    256004PST
    Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    3"1 3/4"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N17000000
    326004PST
    Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    3"1 3/4"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N1800000
    506004PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    3 3/8"2 1/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N1900000
    636004PST
    Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (10 hp @ 240V AC)
    3 3/8"2 1/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N21000000
    806004PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    3 3/4"2 7/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N22000000
    1006004PST
    Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (25 hp @ 240V AC)
    3 3/4"2 7/8"5/16"35Screw TerminalUL Listed, C-UL Listed, CE Marked
    UL 5087815N23000000
     
    Accessories for Disconnect Switches

    Harsh Environment Panel-Mount Disconnect Switches

    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style B. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style A. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style C. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.

    Style B

    Style A

    Style C

    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP69K Enclosure Rating—Rated IP69K, these switches withstand high-pressure, high-temperature washdowns.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Dia.
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Yellow Stainless Steel Housing with Red Actuator
     
    4 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    A203004PST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 15/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K1150000000
     
    Gray Stainless Steel Housing with Gray Actuator
     
    4 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    C203004PST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 1/8"2 3/4"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K116000000
     
    Labels

    Outdoor High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outdoor High-Current Time and Day Activated Switches.
    Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. They control equipment with high currents, such as landscape lighting, pumps, and heaters. Program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    Trippers—Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
    Switches
    Trippers
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage,
    V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, hr.
    Tripper
    Type
    No. of
    Trippers
    Housing
    Material
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    Each
    No. of Trippers
    Included
    Pkg.
    7-Day Timing Cycle
    440 amp @ 240V AC12033.5Removable14Steel4PST
    12 1/2"8 1/4"4"Screw Terminal79915K6800000007 Pair79915K71000000
     
    back to top