    Mil. Spec. Washdown Toggle Switches

    Image of Product. Front orientation. Toggle Switches. Mil. Spec. Washdown Toggle Switches .
    These switches meet MIL-S-3950. A rubber seal protects them from washdowns.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Dp. Behind
    Panel
    Mounting Hardware
    Included
    Wire
    Connection
    Each
    2 Positions
     
    For 1/2" Diameter Panel Cutouts
    22 Off
    Momentary
    4DPST
    Off-(On)
    8 amp @ 125V AC, 10 amp @ 28V DC28V DC
    125V AC
    1.35"YesScrew Terminal8002K129000000
     

    Enclosed Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Enclosed Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Enclosed Disconnect Switches.

    Power Pole

    Neutral Pole

    Cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. These switches are housed in a protective enclosure that resists denting, chipping, and cracking. Mount them to the wall when you run out of space in an electrical panel.
    Use additional switch power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Two-Circuit Switch with Lockout. Front orientation. Disconnect Switches. Enclosed Disconnect Switches, Plastic Housing, 2 Circuits Controlled, Lockout.

    Two-Circuit

    Switch with

    Lockout

    Lockout—Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
    Photovoltaic—Photovoltaic switches can be used with photovoltaic cells which convert sunlight into electricity.
    Switching
    Current,
    amp
    Voltage,
    V DC
    Switch
    Designation
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure Rating
    Certification
    Each
    Yellow Plastic Housing with Red Actuator
     
    2 Circuits Controlled with Lockout/Photovoltaic
    20800DPST
    9 13/16"6 5/16"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K720000000
    32800DPST
    11"7 1/2"5/16"Screw TerminalIP66
    IP67
    NEMA 3S
    NEMA 6P
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    6759K73000000
    50800DPST
    12 5/8"8 11/16"5/16"Screw TerminalIP65
    NEMA 3R
    UL Listed, C-UL Listed, CE Marked
    6759K74000000
    63650DPST
    12 5/8"8 11/16"5/16"Screw TerminalIP65
    NEMA 3R
    UL Listed, C-UL Listed, CE Marked
    6759K71000000
     
    Labels

    Durable Disconnect Switches

    Protected by a steel enclosure, these switches withstand tougher conditions than switches in a plastic housing. Also known as safety switches, they have quick-make/quick-break action to eliminate arcing and prolong switch life. They have a lockout to secure in the off position using a padlock (not included).
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Durable Disconnect Switches.
    Fuse Holder—Switches with a fuse holder are used where overload protection is needed. When the current exceeds the fuse’s rating, the fuse will blow, interrupting the circuit to prevent the switch from overheating, breaking, or causing a fire. These switches require rejection-style fuse clips when used with UL Class RK1, RK5, or T fuses. Note: Horsepower ratings are based on time-delay fuses installed.
    Safety Interlock—Switches with safety interlock keep the door closed when the switch is on and prevent the switch from turning on when the door is open.
    Switches
    Rejection-Style Fuse Clips for
    RK1 and RK5 Fuse Class
    Switching
    Current,
    amp
    Voltage
    Switch
    Designation
    Electrical Phase (hp)
    For No.
    of Wires
    For Fuse UL Class
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Each
    Gray Powder-Coated Steel Housing with Red Actuator
     
    2 Circuits Controlled with Lockout, Safety Interlock, and Fuse Holder
    30240V AC/250V DCDPST
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    3RK1, RK5, K5, H14 1/4"6 5/8"5/16"TabNEMA 1
    UL Listed
    7524K2100000007524K414000000
    100240V AC/250V DCDPST
    Single (15 hp @ 240V AC)3RK1, RK5, K5, T, H17 1/2"11 3/16"5/16"TabNEMA 1
    UL Listed
    7524K230000007524K41300000
     
    2 Circuits Controlled with Lockout and Fuse Holder
    60240V AC/250V DCDPST
    Single (10 hp @ 240V AC)3RK1, RK5, K5, H10 1/16"6 7/16"5/16"TabNEMA 1
    UL Listed
    7524K220000007524K41200000
     
    Fuse Holders

    Outdoor Durable Disconnect Switches

    All switches have quick-make/quick-break action to eliminate arcing and prolong switch life.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Outdoor Durable Disconnect Switches.
    Powder-Coated Steel Housing—The enclosure is steel, so it withstands tougher conditions than plastic enclosures.
    Fuse Holder—Use switches with a fuse holder where overload protection is needed. When the current exceeds the rating of the fuse, it blows. This interrupts the circuit and prevents overheating, damage, and fire. When used with UL Class RK1, RK5, or T fuses, they require rejection-style fuse clips. Note: Horsepower ratings are based on time-delay fuses installed.
    Lockout—They have a lockout to secure in the off position using a padlock (not included).
    Safety Interlock—Switches with safety interlock keep the door closed when the switch is on and prevent the switch from turning on when the door is open.
    NEMA 3R Enclosure Rating—A raintight NEMA 3R rated enclosure protects these switches from falling liquids and light splashing.
    Switches
    Rejection-Style Fuse Clips for
    RK1 and RK5 Fuse Class
    Switching
    Current,
    amp
    Voltage
    Switch
    Designation
    Electrical Phase (hp)
    For No.
    of Wires
    For Fuse UL Class
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Each
    Gray Powder-Coated Steel Housing with Red Actuator
     
    2 Circuits Controlled with Lockout, Safety Interlock, and Fuse Holder
    100240V AC/250V DCDPST
    Single (15 hp @ 240V AC)3RK1, RK5, K5, T, H17 1/2"11 3/16"5/16"TabNEMA 3R
    UL Listed
    7524K2600000007524K413000000
     
    2 Circuits Controlled with Lockout and Fuse Holder
    30240V AC/250V DCDPST
    Single (3 hp @ 240V AC)3RK1, RK5, K5, H8 9/16"5 7/16"5/16"TabNEMA 3R
    UL Listed
    7524K24000007524K411000000
    60240V AC/250V DCDPST
    Single (10 hp @ 240V AC)3RK1, RK5, K5, H10 1/16"6 7/16"5/16"TabNEMA 3R
    UL Listed
    7524K250000007524K41200000
     
    Fuse Holders

    Harsh Environment Panel-Mount Disconnect Switches

    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style B. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style A. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style C. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.

    Style B

    Style A

    Style C

    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP69K Enclosure Rating—Rated IP69K, these switches withstand high-pressure, high-temperature washdowns.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Dia.
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Yellow Stainless Steel Housing with Red Actuator
     
    2 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    A20300DPST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 15/16"2 15/16"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K1120000000
     
    Gray Stainless Steel Housing with Gray Actuator
     
    2 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    C20300DPST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 1/8"2 3/4"2 15/16"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K113000000
     
    Labels

    Wall-Mount Temperature Switches

    Turn heating equipment on or off at a specified temperature. Switches have a probe on a cable for remote temperature readings. Set the actuation point with the adjustment dial.
    Switches
    Image of Product. DPST (Double Pole, Single Throw) Switch with Open Housing. Front orientation. Temperature Switches. Wall-Mount Temperature Switches, DPST—2 Circuits Controlled, Open Housing.
    Image of Product. DPST (Double Pole, Single Throw) Switch with Enclosed Housing. Front orientation. Temperature Switches. Wall-Mount Temperature Switches, DPST—2 Circuits Controlled, Enclosed Housing.

    DPST (Double

    Pole, Single

    Throw) Switch

    with Open Housing

    DPST

    (Double

    Pole,

    Single

    Throw)

    Switch with

    Enclosed

    Housing

    2 Circuits Controlled—Switches that control two circuits are double pole, single throw (DPST). They turn two circuits from on to off (normally closed).
    Open Housing—Switches with an open housing are often added to existing enclosures or custom installations.
    Probe
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Material
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Enclosure
    Rating
    Each
    DPST—2 Circuits Controlled
     
    Open Housing
    60 to 25030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    1/4"5 5/32"Copper4 1/16"2 5/8"3 1/16"No3626K470000000
    200 to 55030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    5/16"4 1/2"Copper4 1/16"2 5/8"3 1/16"No3626K44000000
     
    Enclosed Housing
    0 to 10030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    3/8"4 3/16"Copper5 3/4"3"3 1/8"NoNEMA 1
    3626K11000000
    60 to 25030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    1/4"5 5/32"Copper5 3/4"3"3 1/8"NoNEMA 1
    3626K17000000
    200 to 55030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    5/16"4 7/8"Copper5 3/4"3"3 1/8"NoNEMA 1
    3626K23000000
    300 to 70030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    3/16"13"Nickel5 3/4"3"3 1/8"NoNEMA 1
    3626K19000000
     
    Switch Mounts
    Switches with Pilot Light
    Image of Product. DPST (Double Pole, Single Throw) Switch with Open Housing. Front orientation. Temperature Switches. Wall-Mount Temperature Switches, DPST—2 Circuits Controlled, Open Housing.
    Image of Product. DPST (Double Pole, Single Throw) Switch with Enclosed Housing. Front orientation. Temperature Switches. Wall-Mount Temperature Switches, DPST—2 Circuits Controlled, Enclosed Housing.

    DPST (Double

    Pole, Single

    Throw) Switch

    with Open Housing

    DPST

    (Double

    Pole,

    Single

    Throw)

    Switch with

    Enclosed

    Housing

    Switches with a pilot light indicate when the switch is on.
    2 Circuits Controlled—Switches that control two circuits are double pole, single throw (DPST). They turn two circuits from on to off (normally closed).
    Open Housing—Switches with an open housing are often added to existing enclosures or custom installations.
    Probe
    Temp. Range,
    ° F
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Material
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Enclosure
    Rating
    Each
    DPST—2 Circuits Controlled
     
    Open Housing
    60 to 25030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    1/4"5 5/32"Copper4 1/16"2 5/8"3 1/16"No3626K870000000
    200 to 55030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    5/16"4 1/2"Copper4 1/16"2 5/8"3 1/16"No3626K84000000
     
    Enclosed Housing
    0 to 10030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    3/8"4 3/16"Copper5 3/4"3"3 1/8"NoNEMA 1
    3626K61000000
    60 to 25030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    1/4"5 5/32"Copper5 3/4"3"3 1/8"NoNEMA 1
    3626K67000000
    200 to 55030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    5/16"4 7/8"Copper5 3/4"3"3 1/8"NoNEMA 1
    3626K73000000
    300 to 70030 amp @ 120V AC (Single)
    30 amp @ 277V AC (Three)
    3/16"13"Nickel5 3/4"3"3 1/8"NoNEMA 1
    3626K66000000
     
    Switch Mounts

    Set-to-the-Minute High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Set-to-the-Minute High-Current Time and Day Activated Switches.
    For precise control of high-current equipment such as landscape lighting, pumps, and heaters, these switches schedule on/off times to the exact minute. A backup battery or capacitor maintains the program during a power outage.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week. They have a day skipper that can suspend operation for one to six days.
    2 Circuits Controlled—Two-circuit switches can apply a different program to each circuit.
    Mounting
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage, V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    Housing
    Material
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Hole
    Dia.
    Knockout
    Trade Size
    Wire
    Connection
    Environment
    Certification
    Each
    7 day—With Battery Backup, Lockout, Day Skipper
    230 amp @ 240V AC120/208/240/277281Push ButtonSteelSPST, DPST
    7 3/4"5"3"No0.16"1/2, 3/4
    Screw TerminalIndoor OnlyUL Listed, CSA Certified
    7459K890000000
     
    24-Hr. Timing Cycle—With Capacitor Backup, Lockout
    230 amp @ 240V AC120/208/240/277481Push ButtonSteelSPST, DPST
    7 7/8"5 1/8"3 7/16"No3/16"1/2, 3/4
    Screw TerminalIndoor OnlyUL Listed, CSA Certified
    7459K82000000
     

    Washdown Wall-Mount Temperature Switches

    To protect these switches from splashing water, corrosive liquid, and dust, the housing meets NEMA 4X for washdown conditions. Switches turn heating equipment on or off at a specified temperature. All have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
    DPST—DPST (Double pole, single throw) switch turns two circuits from on to off (normally closed).
    Probe
    Temp. Range
    Temperature
    Accuracy
    No. of Actuation
    Points
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Wire
    Connection
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    DPST—2 Circuits Controlled
     
    Unthreaded PFA-Coated Copper Probe
    70° F to 245° F/20° C to 120° C±4° F/±2.5° C125 amp @ 120V AC (Single)
    25 amp @ 240V AC (Single)
    5/16"6 1/2"Screw Terminal5 7/8"3 1/8"5"NEMA 4X
    35055K710000000
     
    Switch Mounts

    High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. High-Current Time and Day Activated Switches.
    Control equipment with high currents such as landscape lighting, pumps, and heaters. Program these switches to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    Day Skipper—Switches with a day skipper can be programmed to skip operation for one to six days.
    Trippers—Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
    Switches
    Trippers
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage, V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, hr.
    Tripper
    Type
    No. of
    Trippers
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    Environment
    Each
    No. of Trippers
    Included
    Pkg.
    24-Hr. Timing Cycle
    240 amp @ 240V AC120121Removable2DPST
    7 3/4"5"3"Screw TerminalIndoor Only7037K130000001 Pair7037K3200000
    240 amp @ 240V AC208/240/277121Removable2DPST
    7 3/4"5"3"Screw TerminalIndoor Only7037K140000001 Pair7037K320000
     
    24-Hr. Timing Cycle with Day Skipper and Three Skip Screws
    240 amp @ 240V AC120101Removable2DPST
    7 3/4"5"3"Screw TerminalIndoor Only7037K190000001 Pair7037K420000
    240 amp @ 240V AC208/240/277101Removable2DPST
    7 3/4"5"3"Screw TerminalIndoor Only7037K210000001 Pair7037K420000
     
    Screws

    Line-Voltage Thermostats

    Image of Product. For Heaters. Front orientation. 120V AC to 277V AC. Line-Voltage Thermostats.

    For Heaters

    Regulate line-voltage HVAC systems.
    For Heaters—Thermostats for heaters mount to a surface-mount outlet box.
    Cannot Be Sold To—Energy efficiency requirements restrict sales to the listed jurisdictions/areas.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Display
    Type
    Certification
    Cannot Be
    Sold To
    Each
    For Heaters
     
    Dial Control
    120 to 2772250 to 90DPST
    Hardwire4 1/2"2 3/4"1 1/2"NoNoAnalogETL Listed
    Colorado17395K95000000
     

    Programmable Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Programmable Line-Voltage Thermostats.
    Set these thermostats to adjust the temperature at certain times each day. They regulate heaters that use direct electrical power, such as baseboard and wall heaters.
    For
    System
    Overall
    Type
    Efficiency
    Program
    Function
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Display
    Type
    Each
    For Heaters
     
    Push-Button Control
    ElectricSingle StageDaily2401540 to 86DPST
    Hardwire4 7/8"2 3/4"7/8"NoYesDigital5294N130000000
     

    Tamper-Resistant Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Tamper-Resistant Line-Voltage Thermostats.
    Image of Product. Thermostat with Tamper-Resistant Guard Removed. Front orientation. Thermostats. Tamper-Resistant Line-Voltage Thermostats, For Heaters, Dial Control.

    Thermostat with

    Tamper-Resistant

    Guard Removed

    A built-in guard prevents accidental changes and other tampering and protects these thermostats from damage. These thermostats regulate the temperature in HVAC systems that use direct electrical power. They’re often used with baseboard and wall heaters.
    DPST—DPST (double pole, single throw) thermostats control two circuits, so they have an “off” setting that cuts power to the thermostat. As a result, they’re more energy efficient and slightly safer than SPST (single pole, single throw) thermostats, which stay at a low setting instead of turning off completely.
    Cannot Be Sold To—Energy efficiency requirements restrict sales to the listed jurisdictions/areas.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Features
    Display
    Type
    Certification
    Cannot Be
    Sold To
    Each
    For Heaters
     
    Dial Control
    120 to 2772250 to 90DPST
    Hardwire4 9/16"2 13/16"1 3/4"NoNoTamper-Resistant GuardAnalogETL Listed
    Colorado5474N12000000
     

    Outdoor Set-to-the-Minute High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outdoor Set-to-the-Minute High-Current Time and Day Activated Switches.
    Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. They control equipment with high currents, such as landscape lighting, pumps, and heaters. A backup battery maintains the program during a power outage.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    7-Day Timing Cycle—Seven-day switches can perform a different program each day of the week.
    Day Skipper—Switches with a day skipper can be programmed to skip operation for one to six days.
    Mounting
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage, V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, min.
    Timing Adjustment
    Style
    Housing
    Material
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Fasteners
    Included
    Hole
    Dia.
    Knockout
    Trade Size
    Wire
    Connection
    Environment
    Certification
    Each
    24-Hr. Timing Cycle—With Battery Backup, Lockout
    230 amp @ 240V AC120/208/240/277201Push ButtonPolycarbonate
    DPST
    8 3/8"5"3 1/8"No0.26"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed
    7459K670000000
     
    7 day—With Battery Backup, Lockout, Day Skipper
    230 amp @ 240V AC120/208/240/277201Push ButtonPolycarbonate
    DPST
    8 3/8"5"3 1/8"No0.26"1/2, 3/4
    Screw TerminalOutdoor, WetUL Listed
    7459K86000000
     

    Outdoor High-Current Time and Day Activated Switches

    Image of Product. Front orientation. Timer Switches. Outdoor High-Current Time and Day Activated Switches.
    Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. They control equipment with high currents, such as landscape lighting, pumps, and heaters. Program them to turn a device on and off at a set time and day. Position trippers around the clock dial to set on and off times.
    24-Hr. Timing Cycle—24-hr. switches repeat the same program daily.
    Day Skipper—Switches with a day skipper can be programmed to skip operation for one to six days.
    Trippers—Additional trippers (sold separately) are sold in pairs that include one “on” tripper and one “off” tripper.
    Switches
    Trippers
    No. of Circuits
    Controlled
    Switching Current
    @ Voltage
    Input Voltage, V AC
    Max. On/Off
    Cycles, per day
    Min. Set
    Time, hr.
    Tripper
    Type
    No. of
    Trippers
    Housing
    Material
    Switch
    Designation
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    Each
    No. of Trippers
    Included
    Pkg.
    24-Hr. Timing Cycle
    240 amp @ 240V AC120121Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal7037K8300000001 Pair7037K3200000
    240 amp @ 240V AC208/240/277121Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal7037K840000001 Pair7037K320000
     
    24-Hr. Timing Cycle with Day Skipper and Three Skip Screws
    240 amp @ 240V AC120101Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal7037K890000001 Pair7037K420000
    240 amp @ 240V AC208/240/277101Removable2SteelDPST
    9 3/8"5 1/2"3 5/8"Screw Terminal7037K910000001 Pair7037K420000
     
    Screws