McMaster-Carr logo
    Filter by
    System of Measurement
    Actuator Style
    Number of Circuits Controlled
    Number of Terminals
    Wire Connection
    Electrical Phase
    Switch Designation
    Industrial Info Compare
    Switching Current with Heat Sink
    Actuator Height
    Electrical Connection
    Mounting Hole Diameter
    Switch Action
    Switch Starting Position
    Industrial Info Compare
    Housing Material
    Operation Type
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    33 Products

    Light-Touch Subminiature Snap-Acting Switches

    Image of Product. Front orientation. Contains Annotated. Snap-Acting Switches. Light-Touch Subminiature Snap-Acting Switches, Plunger Actuator Style.

    Plunger Actuator Style

    Actuate these switches with a fraction of the force of other subminiature switches for increased responsiveness. They’re a good choice if you need reliable actuation even from a light touch. Among the smallest snap-acting switches we offer, they fit into the tiniest of spaces. To minimize arcing and prevent contacts from sticking, they open and close circuits quickly. They’re often used as door-open indicators on enclosures or as internal components in limit, pressure, and temperature switches.
    Plunger Actuator Style—Switches with a plunger actuator require a push to actuate.
    Housing
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage,
    V AC
    Operating Temp.
    Range, ° F
    Actuator
    Ht.
    No. of
    Terminals
    Lg.
    Ht.
    Dp.
    Certification
    Each
    Plunger Actuator Style
     
    With Quick-Disconnect Terminals
    11 Off or 1 On
    Momentary
    SPDT
    11 amp @ 125V AC
    11 amp @ 250V AC
    250-65 to 2500.1"30.78"0.36"0.25"UL Recognized Component, CSA Certified, CE Marked
    7193K106000000
     
    With Solder Pin Terminals
    11 Off or 1 On
    Momentary
    SPDT
    11 amp @ 125V AC
    11 amp @ 250V AC
    250-65 to 2500.1"30.78"0.36"0.25"UL Recognized Component, CSA Certified, CE Marked
    7193K10700000
     
    Tab
    11 Off or 1 On
    Momentary
    SPDT
    11 amp @ 125V AC
    11 amp @ 250V AC
    250-65 to 2500.1"30.78"0.36"0.25"UL Recognized Component, CSA Certified, CE Marked
    7193K10500000
     

    Solid State Screw Terminal Relays

    Image of Product. 1-Circuit Relay with Covered Terminals and LED Indicator. Front orientation. Relays. Solid State Screw Terminal Relays, 1 Circuit Controlled.
    Image of Product. 1-Circuit Relay with LED Indicator. Front orientation. Relays. Solid State Screw Terminal Relays, 1 Circuit Controlled.
    Image of Product. 1-Circuit Relay with Covered Terminals. Front orientation. Relays. Solid State Screw Terminal Relays, 1 Circuit Controlled.

    1-Circuit

    Relay with

    Covered

    Terminals and

    LED Indicator

    1-Circuit

    Relay with

    LED Indicator

    1-Circuit

    Relay with

    Covered

    Terminals

    Image of Product. 1-Circuit Relay. Front orientation. Relays. Solid State Screw Terminal Relays, 1 Circuit Controlled.
    Image of Product. Front orientation. Electrical Component Heat Sinks. Solid State Screw Terminal Relays.

    1-Circuit

    Relay

    Heat Sinks

    With no moving parts, these solid-state relays are fast switching and require less maintenance, last longer, and are quieter than mechanical switches.
    Relays with High-Starting-Current Protection—Relays with high-starting-current protection are designed with integrated circuits that prevent damage from the large burst of electricity when a device, such as a motor or pump, turns on.
    LED Indicator—Relays with LED indicator let you quickly spot whether a relay is on or off.
    Heat Sinks—Heat sinks disperse heat to increase the relay’s current rating. Mount them to 35 mm DIN rail (also known as DIN 3 rail) for fast installation. They also mount to flat surfaces. Before mounting one-circuit relays, silicone compound or a thermal pad should be placed between the heat sink and relay. Silicone compound is sold separately for heat sinks that do not include it but require it. Two-circuit relays don’t require silicone for mounting.
    Relays
    Heat Sinks
    Silicone
    Compounds
    Switching
    Current @ Voltage
    No. of
    Terminals
    Input Voltage
    Without Heat
    Sink
    With Heat
    Sink, amp
    Max. Switching
    Voltage, V AC
    Ht.
    Wd.
    Dp.
    Each
    Each
    Each
    1 Circuit Controlled with 1 Off—SPST-NO
     
    Relays with High-Starting-Current Protection
    485V AC, 120V AC, 240V AC, 280V AC11 amp @ 240V AC452802.3"1.8"1"7456K240000007456K22200000010405K79000000
    43V DC, 6V DC, 12V DC, 24V DC, 30V DC11 amp @ 120V AC451402.3"1.8"1"7456K22000007456K2220000010405K7900000
    43V DC, 6V DC, 12V DC, 24V DC, 30V DC11 amp @ 240V AC452802.3"1.8"1"7456K26000007456K2220000010405K7900000
    43V DC, 6V DC, 12V DC, 24V DC, 30V DC11 amp @ 380V AC454202.3"1.8"1"7456K1330000007456K2220000010405K7900000
     
    Relays with High-Starting-Current Protection and LED Indicator
    43V DC, 6V DC, 12V DC, 24V DC, 30V DC11 amp @ 240V AC452802.3"1.8"1"7456K1310000007456K2220000010405K7900000
     

    DIN-Rail Mount Touch-Safe Screw Terminal Relays

    Image of Product. Front orientation. Contains Annotated. Relays. DIN-Rail Mount Touch-Safe Screw Terminal Relays.
    Quickly and safely mount these relays on 35 mm DIN rail (also known as DIN 3). IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits.
    3 Circuits Controlled and 4 Circuits Controlled—Relays that control 3 and 4 circuits are built to IEC dimensional standards and are often called IEC contactors.
    12 Terminals—Relays with 12 terminals let you attach the control circuit onto the side that works best for your setup, which reduces the amount of wire you need.
    hp @
    Switching Voltage
    No. of
    Terminals
    Input
    Voltage
    Control
    Power
    Switching Current @
    Voltage (Load Type)
    Max. Switching
    Voltage, V AC
    Single Phase
    Three Phase
    Ht.
    Wd.
    Dp.
    Each
    3 Circuits Controlled with 3 Off—3PST-NO
     
    With 1 Auxiliary Contact—1 Off
    1224V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K321000000
    12120V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K32200000
    12240V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K32300000
    1224V DC5.4 W11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.9"70255K42000000
     
    With 1 Auxiliary Contact—1 On
    1224V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K35100000
    12120V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K35200000
    12240V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K35300000
    1224V DC5.4 W11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.9"70255K45000000
     
    4 Circuits Controlled with 4 Off—4PST-NO
    1224V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K391000000
    12120V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K392000000
    12240V AC6.5 VA11 amp @ 600V AC (Full)
    28 amp @ 600V AC (Resistive)
    6001 hp @ 120V AC
    2 hp @ 240V AC
    5 hp @ 240V AC
    7 1/2 hp @ 480V AC
    10 hp @ 600V AC
    3.2"1.8"3.2"70255K393000000
     
    Accessories and Replacements for Relays
    back to top