Choosing an Electrical Switch
More
Panel-Mount Compact Disconnect Switches
Install these switches in a panel cutout. Small enough to fit in tight spaces, they handle comparable electrical loads to standard sized switches. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All have a lockout so you can secure them in the off position with a padlock (not included). They’re rated IP65 for protection from washdowns.
Switching Current @ Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Dp. Behind Panel | Specifications Met | Each | |
Gray Plastic Housing with Black Actuator | ||||||||
---|---|---|---|---|---|---|---|---|
Stays Switched (Maintained) | ||||||||
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
50 A @ 600 V AC, 50 A @ 24 V DC | 3PST | Single (3 hp @ 120 V AC) Three (7 1/2 hp @ 120 V AC) Three (15 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 000000000 | 0000000 |
4 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
50 A @ 600 V AC, 50 A @ 24 V DC | 4PST | Single (3 hp @ 120 V AC) Three (7 1/2 hp @ 120 V AC) Three (15 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 000000000 | 000000 |
Yellow Plastic Housing with Red Actuator | ||||||||
Stays Switched (Maintained) | ||||||||
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
50 A @ 600 V AC, 50 A @ 24 V DC | 3PST | Single (3 hp @ 120 V AC) Three (7 1/2 hp @ 120 V AC) Three (15 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 00000000 | 000000 |
4 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
50 A @ 600 V AC, 50 A @ 24 V DC | 4PST | Single (3 hp @ 120 V AC) Three (7 1/2 hp @ 120 V AC) Three (15 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 00000000 | 000000 |
Enclosed Compact Disconnect Switches
Small yet mighty, these switches are about as tall and wide as an index card yet durable enough to mount directly to a wall. Their polycarbonate housing protects the switch and resists denting, chipping, and cracking. Rated IP65, the housing also seals out water even in frequently washed down areas. Don’t be fooled by their size—these switches can handle electrical loads comparable to a standard sized switch.
These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All have a lockout, so you can secure them in the off position with a padlock (not included).
For technical drawings and 3-D models, click on a part number.
Yellow Plastic Housing with Red Actuator | ||||||||
---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Environmental Rating | Specifications Met | Each | |
Stays Switched (Maintained) | ||||||||
3 Circuits with Lockout | ||||||||
50 A @ 600 V AC, 50 A @ 24 V DC | 3PST | Single (3 hp @ 120 V AC) Three (15 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) | 5 5/16" | 6 11/16" | IP65 | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 0000000 |
4 Circuits with Lockout | ||||||||
50 A @ 600 V AC, 50 A @ 24 V DC | 4PST | Single (3 hp @ 120 V AC) Three (15 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) | 5 5/16" | 6 11/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
Panel-Mount Disconnect Switches
Install these switches in a panel cutout. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All are UL listed, C-UL listed, and CE marked—they meet American, Canadian, and European safety standards.
Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
Terminal covers prevent contact with live terminals.
For technical drawings and 3-D models, click on a part number.
Switching | |||||||||
---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Dp. Behind Panel | Environmental Rating | Each | |
Yellow Plastic Housing with Red Actuator | |||||||||
Stays Switched (Maintained) | |||||||||
3 Circuits—For 3/8" Panel Cutout Dia. | |||||||||
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 2 13/16" | 2 13/16" | 2 3/8" | IP40 | 00000000 | 000000 |
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | |||||||||
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2 3/8" | IP40 | 00000000 | 00000 |
Gray Plastic Housing with Gray Actuator | |||||||||
Stays Switched (Maintained) | |||||||||
3 Circuits—For 3/8" Panel Cutout Dia. | |||||||||
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 2 13/16" | 2 13/16" | 2 3/8" | IP40 | 00000000 | 00000 |
3 Circuits with Lockout—For 3/8" Panel Cutout Dia. | |||||||||
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 2 3/8" | IP40 | 00000000 | 00000 |
"Main Switch" Label with Adhesive Back—13/16" Ht. × 3 3/16" Wd. | 0000000 | Each | 000000 |
Switching Current, A | Each | |
10 | 0000000 | 000000 |
Switching Current, A | Specifications Met | Each | |
50 | UL Listed, CE Marked | 00000000 | 000000 |
Switching Current, A | Specifications Met | Each | |
50 | UL Listed, CE Marked | 00000000 | 000000 |
For Current, A | Specifications Met | Each | |
50/63 | UL Listed, CE Marked | 00000000 | 000000 |
Enclosed Disconnect Switches
Cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. These switches are housed in a protective enclosure.
Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
For technical drawings and 3-D models, click on a part number.
Switching | ||||||||
---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Environmental Rating | Each | |
Plastic Housing with Red Actuator | ||||||||
Stays Switched (Maintained) | ||||||||
3 Circuits | ||||||||
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 0000000 |
3 Circuits with Lockout | ||||||||
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
2 Circuits with Lockout | ||||||||
50 | 800V DC | DPST | __ | 12 5/8" | 8 11/16" | IP65, NEMA 3R | 0000000 | 000000 |
Plastic Housing with Gray Actuator | ||||||||
Stays Switched (Maintained) | ||||||||
3 Circuits | ||||||||
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
3 Circuits with Lockout | ||||||||
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
"Main Switch" Label with Adhesive Back—13/16" Ht. × 3 3/16" Wd. | 0000000 | Each | 000000 |
Plastic Housing with Red Actuator | |||||
---|---|---|---|---|---|
For Switching Current | Ht. | Wd. | Dp. | Each | |
25A, 32A, 50A, 63A | 2 9/16" | 2 9/16" | 1 5/16" | 0000000 | 000000 |
Switching Current, A | Each | |
10 | 0000000 | 000000 |
Switching Current, A | Specifications Met | Each | |
50 | UL Listed, CE Marked | 00000000 | 000000 |
Switching Current, A | Specifications Met | Each | |
50 | UL Listed, CE Marked | 00000000 | 000000 |
For Current, A | Specifications Met | Each | |
50/63 | UL Listed, CE Marked | 00000000 | 000000 |
Enclosure Disconnect Switches
Install these switches inside an enclosure to prevent it from opening when power is on—turn the switch to disconnect power and release the door. Cut the shaft to fit the enclosure. Use a padlock (not included) to lock switches in the off position. Mount to DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail. UL listed, C-UL listed, and CE marked, these switches meet American, Canadian, and European safety standards.
Use optional sealing gaskets in washdown environments; they create an IP65 rated seal around the actuator.
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
Add junction blocks to connect a ground wire.
Terminal covers prevent contact with live terminals.
Switching | |||||||||
---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Electrical Phase (hp) | Ht. | Wd. | For DIN Rail Ht., mm | Mounting Dp. | Environmental Rating | Each | |
Yellow Plastic Housing with Red Actuator | |||||||||
3 Circuits with Lockout—For 1 3/16" Panel Cutout Dia. | |||||||||
50 | 600V AC | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 000000 |
4 Circuits with Lockout—For 1 3/16" Panel Cutout Dia. | |||||||||
50 | 600V AC | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 000000 |
Gray Plastic Housing with Gray Actuator | |||||||||
3 Circuits with Lockout—For 1 3/16" Panel Cutout Dia. | |||||||||
50 | 600V AC | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 00000 |
For Switching Voltage, A | Each | |
25-63 | 0000000 | 00000 |
Switching Current, A | Specifications Met | Each | |
50 | UL Listed, CE Marked | 00000000 | 000000 |
Switching Current, A | Specifications Met | Each | |
50 | UL Listed, CE Marked | 00000000 | 000000 |
For Current, A | Specifications Met | Each | |
50/63 | UL Listed, CE Marked | 00000000 | 000000 |
Touch-Safe DIN-Rail Mount Infrequent-Cycle Relays
Operate equipment that cycles on and off from your control cabinet. Often called definite-purpose contactors, these relays meet UL 508 for use with air conditioning and heating. They mount directly to 35 mm DIN rail (also known as DIN 3 rail) for fast installation. These relays have recessed terminals that prevent fingers and other objects from touching live circuits.
Auxiliary contacts (sold separately) allow you to add a signaling device or control another relay.
For technical drawings and 3-D models, click on a part number.
Switching Current @ 600V AC | hp @ Switching Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Power | Full Load | Resistive Load | Max. Switching Voltage | Single Phase | Three Phase | Ht. | Wd. | Dp. | Each | |
Relays | ||||||||||||
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | ||||||||||||
10 | 24V AC | 6.5VA | 40A | 50A | 600V AC | 3 hp @ 120 V AC 7 1/2 hp @ 240 V AC | 10 hp @ 240 V AC 30 hp @ 480 V AC 40 hp @ 600 V AC | 3.5" | 1.8" | 3.5" | 00000000 | 0000000 |
10 | 24V AC | 6.5VA | 50A | 55A | 600V AC | 3 hp @ 120 V AC 10 hp @ 240 V AC | 15 hp @ 240 V AC 30 hp @ 480 V AC 40 hp @ 600 V AC | 3.5" | 1.8" | 3.5" | 00000000 | 000000 |
10 | 120V AC | 6.5VA | 40A | 50A | 600V AC | 3 hp @ 120 V AC 7 1/2 hp @ 240 V AC | 10 hp @ 240 V AC 30 hp @ 480 V AC 40 hp @ 600 V AC | 3.5" | 1.8" | 3.5" | 00000000 | 000000 |
10 | 120V AC | 6.5VA | 50A | 55A | 600V AC | 3 hp @ 120 V AC 10 hp @ 240 V AC | 15 hp @ 240 V AC 30 hp @ 480 V AC 40 hp @ 600 V AC | 3.5" | 1.8" | 3.5" | 00000000 | 000000 |
10 | 240V AC | 6.5VA | 40A | 50A | 600V AC | 3 hp @ 120 V AC 7 1/2 hp @ 240 V AC | 10 hp @ 240 V AC 30 hp @ 480 V AC 40 hp @ 600 V AC | 3.5" | 1.8" | 3.5" | 00000000 | 000000 |
10 | 240V AC | 6.5VA | 50A | 55A | 600V AC | 3 hp @ 120 V AC 10 hp @ 240 V AC | 15 hp @ 240 V AC 30 hp @ 480 V AC 40 hp @ 600 V AC | 3.5" | 1.8" | 3.5" | 00000000 | 000000 |
10 | 24V DC | 5.4W | 40A | 50A | 600V AC | 3 hp @ 120 V AC 7 1/2 hp @ 240 V AC | 10 hp @ 240 V AC 30 hp @ 480 V AC 40 hp @ 600 V AC | 3.5" | 1.8" | 4.2" | 0000000 | 000000 |
10 | 24V DC | 5.4W | 50A | 55A | 600V AC | 3 hp @ 120 V AC 10 hp @ 240 V AC | 15 hp @ 240 V AC 30 hp @ 480 V AC 40 hp @ 600 V AC | 3.5" | 1.8" | 4.2" | 0000000 | 000000 |
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | ||||||||||||
12 | 24V AC | 6.5VA | 40A | 50A | 600V AC | 3 hp @ 120 V AC 7 1/2 hp @ 240 V AC | 10 hp @ 240 V AC 30 hp @ 480 V AC 40 hp @ 600 V AC | 3.5" | 2.4" | 3.5" | 00000000 | 000000 |
12 | 120V AC | 6.5VA | 40A | 50A | 600V AC | 3 hp @ 120 V AC 7 1/2 hp @ 240 V AC | 10 hp @ 240 V AC 30 hp @ 480 V AC 40 hp @ 600 V AC | 3.5" | 2.4" | 3.5" | 00000000 | 000000 |
12 | 240V AC | 6.5VA | 40A | 50A | 600V AC | 3 hp @ 120 V AC 7 1/2 hp @ 240 V AC | 10 hp @ 240 V AC 30 hp @ 480 V AC 40 hp @ 600 V AC | 3.5" | 2.4" | 3.5" | 00000000 | 000000 |
Circuit Board Relays
Smaller than relays with electrical wiring, these relays fit in compact devices. Mount them through holes on circuit boards with their solder pin terminals. Use them to control heaters, fans, and other high-power components from a low-power circuit.
For technical drawings and 3-D models, click on a part number.
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | Mechanical Life Cycles | Ht. | Wd. | Dp. | Pin Lg. | Each | |
Mechanical | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | |||||||||||
6 | 12V DC | 141 | 50 A @ 400 V AC | 400V AC | 1,000,000 | 2" | 1.3" | 2.3" | 0.18" | 0000000 | 000000 |
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | |||||||||||
8 | 12V DC | 224 | 50 A @ 400 V AC | 400V AC | 1,000,000 | 2" | 1.3" | 2.3" | 0.18" | 0000000 | 00000 |
8 | 24V DC | 71 | 50 A @ 400 V AC | 400V AC | 1,000,000 | 2" | 1.3" | 2.3" | 0.18" | 0000000 | 00000 |
Infrequent-Cycle Relays
For use with equipment that cycles on and off, these relays meet UL 508 for air conditioning and heating. Connections are accessible from the front, so you can mount relays side-by-side. Also known as definite-purpose contactors.
Enclosures (sold separately) are NEMA 1 rated to protect contacts from corrosion.
Also Available: Auxiliary contacts for 3.8"-7.2" Ht. relays. They allow you to add a signaling device or control another relay. Please select 6564K99, then select the McMaster-Carr part number of your relay and whether you want to switch one circuit on (1 Normally Open) or off (1 Normally Closed).
For technical drawings and 3-D models, click on a part number.
Switching Current @ 600V AC | hp @ Switching Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Power | Full Load | Resistive Load | Single Phase | Three Phase | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | |
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||||
With Quick-Disconnect and Screw Terminals | ||||||||||||
2 | 24V AC | 6VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 000000 |
2 | 120V AC | 6VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
2 | 208V AC, 240V AC | 6VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 00000 |
2 Circuits Controlled with 2 Off (Normally Open)—DPST-NO | ||||||||||||
With Quick-Disconnect and Screw Terminals | ||||||||||||
4 | 24V AC | 6.5VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 000000 |
4 | 24V AC | 10VA | 50A | 65A | 3 hp @ 115 V AC 10 hp @ 230 V AC | 15 hp @ 230 V AC 30 hp @ 460 V AC 30 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 | 120V AC | 6.5VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 000000 |
4 | 120V AC | 10VA | 50A | 65A | 3 hp @ 115 V AC 10 hp @ 230 V AC | 15 hp @ 230 V AC 30 hp @ 460 V AC 30 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 | 24V DC | 3.1W | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | __ | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 | 24V DC | 3.1W | 50A | 65A | 3 hp @ 115 V AC 10 hp @ 230 V AC | 15 hp @ 230 V AC 30 hp @ 460 V AC 30 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 | 208V AC, 240V AC | 6.5VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | __ | 3.2" | 2" | 2.3" | 0.25" | 00000000 | 000000 |
4 | 208V AC, 240V AC | 10VA | 50A | 65A | 3 hp @ 115 V AC 10 hp @ 230 V AC | 15 hp @ 230 V AC 30 hp @ 460 V AC 30 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | ||||||||||||
With Quick-Disconnect and Screw Terminals | ||||||||||||
6 | 24V AC | 7VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | 10 hp @ 230 V AC 20 hp @ 460 V AC 20 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
6 | 24V AC | 10VA | 50A | 65A | 3 hp @ 115 V AC 10 hp @ 230 V AC | 15 hp @ 230 V AC 30 hp @ 460 V AC 30 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
6 | 120V AC | 7VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | 10 hp @ 230 V AC 20 hp @ 460 V AC 20 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
6 | 120V AC | 10VA | 50A | 65A | 3 hp @ 115 V AC 10 hp @ 230 V AC | 15 hp @ 230 V AC 30 hp @ 460 V AC 30 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
6 | 24V DC | 3.1W | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | 10 hp @ 230 V AC 20 hp @ 460 V AC 20 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
6 | 24V DC | 3.1W | 50A | 65A | 3 hp @ 115 V AC 10 hp @ 230 V AC | 15 hp @ 230 V AC 30 hp @ 460 V AC 30 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
6 | 208V AC, 240V AC | 7VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | 10 hp @ 230 V AC 20 hp @ 460 V AC 20 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
6 | 208V AC, 240V AC | 10VA | 50A | 65A | 3 hp @ 115 V AC 10 hp @ 230 V AC | 15 hp @ 230 V AC 30 hp @ 460 V AC 30 hp @ 575 V AC | 3.8" | 2.4" | 3.4" | 0.25" | 00000000 | 000000 |
4 Circuits Controlled with 4 Off (Normally Open)—4PST-NO | ||||||||||||
With Quick-Disconnect and Screw Terminals | ||||||||||||
8 | 24V AC | 50.4VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | 10 hp @ 230 V AC 20 hp @ 460 V AC 20 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | 00000000 | 000000 |
8 | 120V AC | 50.4VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | 10 hp @ 230 V AC 20 hp @ 460 V AC 20 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | 00000000 | 000000 |
8 | 24V DC | 5.1W | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | 10 hp @ 230 V AC 20 hp @ 460 V AC 20 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | 00000000 | 000000 |
8 | 208V AC, 240V AC | 50.4VA | 40A | 50A | 3 hp @ 115 V AC 7 1/2 hp @ 230 V AC | 10 hp @ 230 V AC 20 hp @ 460 V AC 20 hp @ 575 V AC | 3.8" | 2.7" | 3.4" | 0.25" | 00000000 | 000000 |
Enclosures for 60A 3PST-NO Relays and 4PST-NO Relays | 00000000 | Each | 0000000 |
Stud-Terminal Relays
These relays are suitable for DC-powered equipment such as forklifts, floor scrubbers, and trucks. They are rated for continuous operation for cycles that run longer than 30 seconds.
4- and 6-terminal relays allow different input and switching voltages.
For technical drawings and 3-D models, click on a part number.
High-Starting-Current Vehicle Relays
Relay Socket and
Surface Mounting
Also known as automotive relays, these relays can handle high starting (inrush) currents.
Relays for surface mounting have a tab for added security in high-vibration applications.
Relays | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Relay Sockets with Crimp-On Terminals | Relay Sockets with Wire Leads | |||||||||||||
Number of Terminals | Input Voltage | Off (Normally Open) Circuit Position | Max. Switching Voltage | Max. Starting Current, A | Control Current, mA | Ht. | Wd. | Dp. | Quick-Disconnect Tab Wd. | Each | Each | Each | |||
For Relay Socket and Surface Mounting | |||||||||||||||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||||||
4 | 12V DC | 50 A @ 12 V DC | 18V DC | 150 | 138 | 1.2" | 1" | 1" | 0.25" and 0.375" | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 000000 |