Hazardous Location Recessed Wall Lights

Mount lights in recessed spaces so the lens is flush with the wall. These fixtures are ETL and C-ETL listed for Class I, Division 2, Groups A, B, C, and D; and Class II, Division 2, Groups F and G for use where ignitable concentrations of hazardous material occur infrequently, such as in the case of an accidental spill or failure of a ventilation system. They withstand acetylene, hydrogen, ethylene, propane, carbonaceous dusts, and nonconductive dusts. These lights are often used in freestanding buildings, such as paint spray booths, so the back opens like a door for changing light bulbs from the outside. They can be hardwired to operate on any of the voltages listed. They work with tubular fluorescent bulbs (sold separately).
Lights | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Holes | Bulbs | ||||||||||||||
Lg. | Wd. | Ht. | Voltage | Bulbs Included | No. of Bulbs Required | Max. Wattage per Bulb | Housing Material | Mounting Hardware Included | No. of | Dia. | Specifications Met | Each | Pkg. Qty. | Pkg. | ||
For Tubular T8 Fluorescent Bulbs | ||||||||||||||||
53 1/4" | 21 3/4" | 5 3/4" | 120V AC, 277V AC | No | 4 | 32W | Steel | Yes | 12 | 5/16" | ETL Listed, C-ETL Listed | 00000000 | 0000000 | 6 | 0000000 | 000000 |
Plug-In Tubular Portable Lights
Hang these lights above your workspace—they shine through long tubes to distribute even light with minimal glare and shadows. Carry them where you need them and suspend them from pipes, beams, and other overhead surfaces. A plastic lens keeps drops and dings from breaking the lights.
Style A and C hang from included hooks at each end.
Style B are our brightest tubular portable lights, shining from four light tubes encased together. They mount with the included straps, or you can stand them on end for a freestanding light.
Style D hang vertically from an included hook at one end.
Lights with an SJO cord resist oil. Lights with an SJOW cord resist oil and weather. Lights with an SJOOW cord resist oil better than lights with an SJO or SJOW cord, and they also resist weather.
Lights with an outlet included can be daisy chained together to avoid running separate extension cords. Connect up to 20 lights.
Lights that cannot be sold to the listed areas are restricted by local regulatory limits on mercury content.




Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Lg. | Dia. | Wd. | Dp. | Brightness, lumens | Light Appearance | Cord Lg., ft. | Electrical Connection Type | Cord Type | Outlet Included | Max. Outlet Current | Wire Gauge | Mount Type | Cannot Be Sold To | Each | |
For Replaceable LED Bulbs | ||||||||||||||||
A | 31" | 2" | __ | __ | 1,200 | Cool (5000K) | 25 | Three-Prong Plug | SJOOW | Yes | 14A | 14 | Hook | __ | 00000000 | 0000000 |
A | 31" | 2" | __ | __ | 1,200 | Cool (5000K) | 25 | Three-Prong Plug | SJOW | No | __ | 18 | Hook | __ | 0000000 | 000000 |
A | 53" | 2" | __ | __ | 2,160 | Cool (5000K) | 25 | Three-Prong Plug | SJOOW | Yes | 14A | 14 | Hook | __ | 00000000 | 000000 |
B | 27 5/8" | __ | 7 3/8" | 6 1/8" | 5,000 | Cool (5000K) | 10 | Three-Prong Plug | SJOW | Yes | 14A | 14 | Suspension | __ | 00000000 | 000000 |
B | 51 3/4" | __ | 7 3/8" | 6 1/8" | 7,200 | Cool (5000K) | 10 | Three-Prong Plug | SJOW | Yes | 14A | 14 | Suspension | __ | 00000000 | 000000 |
C | 55" | 2" | __ | __ | 2,100 | Cool (5000K) | 25 | Three-Prong Plug | SJO | No | __ | 18 | Hook | __ | 0000000 | 000000 |
For Replaceable Fluorescent Bulbs | ||||||||||||||||
D | 26 1/2" | 2" | __ | __ | 825 | Cool (4100K) | 25 | Three-Prong Plug | SJT | No | __ | 18 | Hook | Canada, CA, CO, OR, RI | 0000000 | 00000 |

Overall Lg. | Equiv. Fluorescent Bulb Wattage | Brightness, lumens | CRI | Light Setting | Cannot Be Sold To | Pkg. Qty. | Pkg. | |
T8 Bulb (1" Dia.) | ||||||||
---|---|---|---|---|---|---|---|---|
18" | 15W | 870 | 59 | Dimmable | Canada, CA, CO, OR, RI | 2 | 0000000 | 000000 |
Sockets for Tubular Light Bulbs
Replace worn sockets in light fixtures. These sockets work with tubular fluorescent bulbs, and some also work with LED bulbs.
Sockets for rapid and preheat ballasts are also known as non-shunted.
Sockets for instant-start ballasts are also known as shunted.


For Max. | For Wire | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Ballast Start Type | Bulb Wattage | Voltage | Mount Type | Ht. | Wd. | Dp. | Material | Color | Gauge | Construction | Specifications Met | Pair | |
For Bi-Pin Base | |||||||||||||
Instant | 660W | 600V AC | Slide On | 1 3/4" | 1 1/4" | 3/4" | Plastic | White | 18 | Solid, Stranded | CSA Certified, UL Listed | 0000000 | 000000 |
For Single Pin Base | |||||||||||||
Instant | 660W | 600V AC | Slide On | 1 7/8" | 1 3/8" | 1 7/8" | Plastic | White | 18 | Solid, Stranded | CSA Certified, UL Listed | 0000000 | 0000 |


For Max. | For Wire | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Ballast Start Type | Bulb Wattage | Voltage | Mount Type | Ht. | Wd. | Dp. | Material | Color | Gauge | Construction | Specifications Met | Pair | |
For Bi-Pin Base | |||||||||||||
Rapid, Preheat | 660W | 600V AC | Slide On | 1 3/4" | 1 1/4" | 3/4" | Plastic | White | 18 | Solid, Stranded | CSA Certified, UL Listed | 0000000 | 00000 |
Rapid, Preheat | 660W | 600V AC | Slide On | 2 1/8" | 1 1/4" | 3/4" | Plastic | White | 18 | Solid, Stranded | CSA Certified, UL Listed | 0000000 | 0000 |
For Recessed Double-Contact Base | |||||||||||||
Rapid, Preheat | 660W | 600V AC | Slide On | 2 3/8" | 1 1/2" | 2" | Plastic | White | 18 | Solid, Stranded | CSA Certified, UL Listed | 0000000 | 00000 |
Tight-Hold Sockets for Tubular Light Bulbs

Lock bulbs in place to prevent vibration from shaking them loose. They replace worn sockets in light fixtures. These sockets work with tubular fluorescent or LED bulbs.
Sockets for rapid and preheat ballasts are also known as non-shunted.
Sockets for instant-start ballasts are also known as shunted.
For Max. | For Wire | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Ballast Start Type | Bulb Wattage | Voltage | Mount Type | Ht. | Wd. | Dp. | Material | Color | Gauge | Construction | Specifications Met | Pair | |
For T8 Bulbs—Fluorescent | |||||||||||||
For Bi-Pin Base | |||||||||||||
Rapid, Programmed | 600W | 600V AC | Slide On | 1 3/8" | 1 1/8" | 3/4" | Plastic | White | 18 | Solid, Stranded | CSA Certified, UL Listed | 0000000 | 00000 |
For T8 Bulbs—Fluorescent and LED | |||||||||||||
For Bi-Pin Base | |||||||||||||
Instant | 660W | 600V AC | Slide On | 1 3/8" | 1 1/8" | 3/4" | Plastic | White | 18 | Solid, Stranded | CSA Certified, UL Listed | 0000000 | 00000 |
For T8 and T12 Bulbs—Fluorescent and LED | |||||||||||||
For Bi-Pin Base | |||||||||||||
Rapid, Preheat | 660W | 600V AC | Slide On | 1 3/8" | 1" | 3/8" | Plastic | White | 18 | Solid, Stranded | CSA Certified, UL Listed | 0000000 | 0000 |
Light Socket Locking Clips


Stop vibration from shaking tubular fluorescent and LED bulbs loose.
For Bulb | ||||||
---|---|---|---|---|---|---|
Base Type | Shape | Shape No. | Material | Specifications Met | Each | |
For Fluorescent and LED Bulbs | ||||||
Bi-Pin | Tubular | T8, T12 | Plastic | CSA Certified, UL Listed | 0000000 | 00000 |
Blacklight Blue Light Bulbs


Detect UV-reflective materials that are invisible to the naked eye with these bulbs. They contain a blue filter that absorbs the visible light they produce while allowing long wave ultraviolet (UV-A) light to pass through. They appear black when turned off. These bulbs are not for use in bug zappers. A bulb’s estimated yearly cost is based on 3 hours of usage per day at $0.11 per kWh.
Bulbs cannot be sold to the listed areas because they exceed local regulatory limits on mercury.
For technical drawings and 3-D models, click on a part number.
Electronic Ballasts for Tubular Fluorescent Light Bulbs

In addition to being more energy-efficient than magnetic ballasts, these electronic ballasts are lighter and quieter. Ballasts that can operate multiple bulbs may have more wires than you need. Cover unused wires with a wire nut.
Instant-start ballasts turn on immediately. They are the most energy-efficient, but shorten the bulb's life.
Programmed-start ballasts provide the longest bulb life, but they take longer than instant- and rapid-start ballasts to turn on. They are often used with motion-sensing light controls.
For Bulb Trade No. | For No. of Bulbs | For Bulb Wattage | Voltage | No. of Wire Leads | Light Setting | Lg. | Wd. | Dp. | Min. Start Temp., °F | Specifications Met | Each | |
Instant Start | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tubular T8 Bulbs | ||||||||||||
F17T8, F25T8, F32T8 | 1 | 17W, 25W, 32W | 120V AC/277V AC | 4 | Not Dimmable | 9 1/2" | 1 1/8" | 1 1/8" | 0° | UL Listed | 0000000 | 000000 |
F17T8, F25T8, F32T8 | 3, 4 | 17W, 25W, 32W | 120V AC/277V AC | 8 | Not Dimmable | 9 1/2" | 1 3/8" | 1" | 0° | UL Listed | 0000000 | 00000 |
F17T8, F25T8, F32T8, F40T8 | 1, 2 | 17W, 25W, 32W, 40W | 120V AC/277V AC | 5 | Not Dimmable | 9 1/2" | 1 3/8" | 1" | 0° | UL Listed | 0000000 | 00000 |
F25T8, F32T8 | 2, 3 | 25W, 32W | 120V AC/277V AC | 6 | Not Dimmable | 9 1/2" | 1 3/8" | 1" | 0° | UL Listed | 0000000 | 00000 |
F96T8 | 2 | 59W | 120V AC/277V AC | 5 | Not Dimmable | 9 1/2" | 1 1/4" | 1" | 32° | UL Listed | 0000000 | 00000 |
For U-Shaped T8 Bulbs | ||||||||||||
F17, F25, F32, FBO16, FBO24, FBO29/SS, FBO31, FBO32, FO17, FO25/WW, FO28/SS, FO30/SS | 1, 2 | 25W, 28W, 29W, 30W, 32W | 120V AC/120V DC/277V AC/277V DC | 5 | Not Dimmable | 9 1/2" | 1 3/16" | 1" | 0° | UL Listed | 0000000 | 00000 |
Programmed Start | ||||||||||||
For Tubular T8 Bulbs | ||||||||||||
F17T8, F25T8, F32T8 | 1 | 17W, 25W, 32W | 120V AC/277V AC | 6 | Not Dimmable | 9 1/2" | 1 3/8" | 1" | 0° | UL Listed | 0000000 | 00000 |
F17T8, F25T8, F32T8 | 2 | 17W, 25W, 32W | 120V AC/277V AC | 8 | Not Dimmable | 9 1/2" | 1 3/8" | 1" | 0° | UL Listed | 0000000 | 00000 |
FBO31, FBO32, FO32 | 1 | 32W | 120V AC/120V DC/277V AC/277V DC | 8 | Dimmable | 9 1/2" | 1 3/4" | 1" | 50° | UL Listed | 0000000 | 000000 |
FBO31, FBO32, FO32 | 2 | 32W | 120V AC/120V DC/277V AC/277V DC | 11 | Dimmable | 9 1/2" | 1 3/4" | 1" | 50° | UL Listed | 0000000 | 000000 |
FBO31, FBO32, FO32 | 4 | 32W | 120V AC/120V DC/277V AC/277V DC | 17 | Dimmable | 16 3/4" | 1 3/4" | 1" | 50° | UL Listed | 0000000 | 000000 |
For Tubular T8/HO Bulbs | ||||||||||||
F96T8/HO | 1, 2 | 86W | 120V AC/277V AC | 8 | Not Dimmable | 9 1/2" | 1 3/4" | 1 1/4" | -20° | UL Listed | 0000000 | 00000 |
Magnetic Ballasts for Tubular Fluorescent Light Bulbs

These ballasts are often found in older installations. Ballasts that can operate multiple bulbs may have more wires than you need. Cover unused wires with a wire nut. Ballasts take several seconds to turn on and require a starter.