Adjustable-Power Temperature Controllers for Plug-In Heaters
Plug | Socket | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Output Voltage Range, V AC | Current, amp | Input Voltage, V AC | Electrical Connection | No. of Blades | NEMA Type | End Shape | NEMA Type | End Shape | Cord Lg., ft. | Ht. | Wd. | Dp. | Enclosure Rating | Each | ||
| 36 to 120 | 10 | 120 | Straight Blade | 3 | 5-15 | Straight | 5-15 | Straight | 6 | 4 5/8" | 2 11/16" | 2" | NEMA 4X, NEMA 7 | 4550T5 | 000000 | |
Remote-Sensing Hazardous Location Line-Voltage Thermostats
Overall | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage, V AC | Current, amp | Temp. Setting, ° F | Switch Designation | Electrical Connection Type | Ht. | Wd. | Dp. | Sensor Cord Lg., ft. | For Use Outdoors | Mounting Fasteners Included | Mounting Hole Dia. | Display Type | Hazardous Location Rating | Enclosure Rating | Certification | Each | |||
For Air Conditioners and Heaters | |||||||||||||||||||
Dial Control | |||||||||||||||||||
| 120 to 277 | 22 | 20 to 80 | SPDT | Hardwire | 5 7/8" | 3" | 3 1/4" | 6 | No | No | 3/8" | Analog | NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 7, NEMA 9 | CSA Certified, UL Listed | 1877K24 | 0000000 | ||
Hazardous Location Threaded Temperature Switches
Probe | SPDT | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, ° F | Temp. Accuracy | No. of Actuation Points | Actuation Tolerance | No. of Circuits Controlled | Max. Switching Current @ Voltage (Electrical Phase) | Dia. | Lg. | Max. Pressure, psi | Ht. | Wd. | Dp. | Enclosure Rating | Hazardous Location Rating | Certification | Each | |||
Threaded Brass Probe—1/2 NPT Male | ||||||||||||||||||
Adjustable Actuation Point | ||||||||||||||||||
| 0 to 225 | ±2° F | 1 | -1% to 1% | 1 | 15 amp @ 125V AC (Single) 15 amp @ 250V AC (Single) 15 amp @ 480V AC (Single) | 9/16" | 1 7/8" | 1,897 | 10" | 5 1/8" | 5 3/16" | IP66, NEMA 4X, NEMA 7, NEMA 9 | ATEX II 2 D Ex Tb IIIC T85° C Db ATEX II 2 G Ex Db IIC T6 Gb IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IECEx Ex D IIC T6 Gb IECEx Ex Tb IIIC T85° C Db NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA | UL Listed, C-UL Listed, CE Marked | 5032K67 | 0000000 | ||
| 0 to 225 | ±2° F | 2 | -1% to 1% | 2 | 15 amp @ 125V AC (Single) 15 amp @ 250V AC (Single) 15 amp @ 480V AC (Single) | 9/16" | 1 7/8" | 1,784 | 10" | 5 1/8" | 5 3/16" | IP66, NEMA 4X, NEMA 7, NEMA 9 | ATEX II 2 D Ex Tb IIIC T85° C Db ATEX II 2 G Ex Db IIC T6 Gb IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IECEx Ex D IIC T6 Gb IECEx Ex Tb IIIC T85° C Db NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA | UL Listed, C-UL Listed, CE Marked | 5032K87 | 00000000 | ||
Hazardous Location Wall-Mount Temperature Switches
Probe | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Temp. Accuracy | No. of Actuation Points | Max. Switching Current @ Voltage (Electrical Phase) | Dia. | Lg. | Ht. | Wd. | Dp. | Enclosure Rating | Hazardous Location Rating | Includes | Each | |||
SPDT—1 Circuit Controlled | |||||||||||||||
Threaded Stainless Steel Probe—1/2 NPT Male | |||||||||||||||
| 30° F to 250° F | ±5° F | 1 | 15 amp @ 125V AC (Single) 15 amp @ 250V AC (Single) 15 amp @ 480V AC (Single) | 3/8" | 2 5/8" | 9 5/16" | 5 1/8" | 5 3/16" | IP66, NEMA 4X, NEMA 7, NEMA 9 | ATEX II 2 D Ex Tb IIIC T85° C Db ATEX II 2 G Ex Db IIC T6 Gb IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IECEx Ex D IIC T6 Gb IECEx Ex Tb IIIC T85° C Db NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA | 1/2 × 3/4 NPT Adapter Bushing | 5032K66 | 000000000 | ||
SPDT—2 Circuits Controlled | |||||||||||||||
Unthreaded Stainless Steel Probe | |||||||||||||||
| 30° F to 250° F | ±5° F | 2 | 15 amp @ 125V AC (Single) 15 amp @ 250V AC (Single) 15 amp @ 480V AC (Single) | 3/8" | 2 5/8" | 9 5/16" | 5 1/8" | 5 3/16" | IP66, NEMA 4X, NEMA 7, NEMA 9 | ATEX II 2 D Ex Tb IIIC T85° C Db ATEX II 2 G Ex Db IIC T6 Gb IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IECEx Ex D IIC T6 Gb IECEx Ex Tb IIIC T85° C Db NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA | — | 5032K86 | 00000000 | ||
Hazardous Location Line-Voltage Thermostats
Overall | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage, V AC | Current, amp | Temp. Setting, ° F | Switch Designation | Electrical Connection Type | Ht. | Wd. | Dp. | For Use Outdoors | Mounting Fasteners Included | Mounting Hole Dia. | Display Type | Hazardous Location Rating | Enclosure Rating | Certification | Cannot Be Sold To | Each | |||
For Air Conditioners and Heaters | |||||||||||||||||||
Dial Control | |||||||||||||||||||
| 24 to 277 | 22 | 50 to 90 | SPDT | Hardwire | 5 3/4" | 6 3/8" | 5 5/8" | No | No | 1/4" | Analog | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 7 | CSA Certified, UL Listed | Colorado | 1877K23 | 0000000 | ||
| 24 to 277 | 22 | 50 to 90 | DPDT | Hardwire | 5 3/4" | 6 3/8" | 5 5/8" | No | No | 1/4" | Analog | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 7 | CSA Certified, UL Listed | Colorado | 1877K25 | 000000 | ||