McMaster-Carr logo
    Filter by
    Thermocouple Probe Type
    Probe Type
    For DIN Panel Cutout Size
    System of Measurement
    Output Voltage
    Industrial Info Snippet
    Measurement Unit
    Total Number of Outputs
    Number of Outputs
    Mounting Location
    Wire Connection
    Thermocouple Probe Connection
    Maximum Temperature for Type K Probe
    Display Type
    Electrical Phase
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    62 Products

    Autotuning Temperature Controllers

    Ideal in systems with rapid, unpredictable, or complex temperature changes, these controllers turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. They work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. You can also manually select the PID variables. These controllers read temperature with a highly sensitive thermocouple or RTD probe (both not included) in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. All fit into instrument panels with DIN cutouts. Use the keypad to adjust the actuation point, reset point, other settings.
    All meet American, Canadian, and European safety standards.
    Mechanical Relay Output
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN Panel

    Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 3/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 3/16 DIN Panel

    Cutout Size

    For 1/4 DIN Panel

    Cutout Size

    Mechanical relay outputs actuate circuits directly. All are single pole, single throw (SPST) relays and turn one circuit from off to on (normally open).
    For Alarming—Alarm outputs can also be configured to actuate simple devices.
    IP20 Enclosure Rating and IP50 Enclosure Rating—IP20 rated controllers prevent objects about the size of a finger from coming into contact with a live circuit. IP50 rated controllers protect against dust.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 25015/16"1 7/8"3 5/8"IP20, IP50
    38615K1710000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"15/16"3 13/16"IP20, IP50
    38615K75000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K181000000
    B, E, J, K, L, N, R, S, T2Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K78000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K182000000
    B, E, J, K, L, N, R, S, T4Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K183000000
     
    For 1/8 DIN Panel Cutout Size–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K191000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K86000000
     
    For 1/8 DIN Panel Cutout Size–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K194000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K83000000
     
    For 3/16 DIN Panel Cutout Size–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 27/32"2 27/32"2 3/8"IP20, IP50
    38615K271000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 9/16"2 7/8"2 3/8"IP20, IP50
    38615K89000000
     
    For 1/4 DIN Panel Cutout Size–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K281000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K93000000
    B, E, J, K, L, N, R, S, T4Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K282000000
     
    Accessories for Temperature Controllers
    Solid State Relay Output
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN Panel

    Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 3/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 3/16 DIN Panel

    Cutout Size

    For 1/4 DIN Panel

    Cutout Size

    Solid state relay outputs send a pulse signal to directly control an external solid state relay (not included). They have a longer service life than mechanical and signal relays. Use them for more precise and rapid control switching than mechanical relays.
    For Alarming—Alarm outputs can also be configured to actuate simple devices.
    IP20 Enclosure Rating and IP50 Enclosure Rating—IP20 rated controllers prevent objects about the size of a finger from coming into contact with a live circuit. IP50 rated controllers protect against dust.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 25015/16"1 7/8"3 5/8"IP20, IP50
    38615K1720000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"15/16"3 13/16"IP20, IP50
    38615K76000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K184000000
    B, E, J, K, L, N, R, S, T2Heating—1 5V DC Solid State Relay
    Cooling—1 5V DC Solid State Relay
    Thermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K185000000
    B, E, J, K, L, N, R, S, T2Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    SPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K79000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K81000000
     
    For 1/8 DIN Panel Cutout Size–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K192000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K87000000
     
    For 1/8 DIN Panel Cutout Size–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K195000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K84000000
     
    For 3/16 DIN Panel Cutout Size–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2502 27/32"2 27/32"2 3/8"IP20, IP50
    38615K272000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 9/16"2 7/8"2 3/8"IP20, IP50
    38615K91000000
     
    For 1/4 DIN Panel Cutout Size–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K283000000
    B, E, J, K, L, N, R, S, T2Heating—1 5V DC Solid State Relay
    Cooling—1 5V DC Solid State Relay
    Thermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K284000000
    B, E, J, K, L, N, R, S, T3Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K94000000
    B, E, J, K, L, N, R, S, T4Heating—1 14V DC Solid State Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K96000000
     
    Accessories for Temperature Controllers
    Analog Signal Output
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN Panel

    Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 3/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 3/16 DIN Panel

    Cutout Size

    For 1/4 DIN Panel

    Cutout Size

    Analog signal outputs are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
    For Alarming—Alarm outputs can also be configured to actuate simple devices.
    IP20 Enclosure Rating and IP50 Enclosure Rating—IP20 rated controllers prevent objects about the size of a finger from coming into contact with a live circuit. IP50 rated controllers protect against dust.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 25015/16"1 7/8"3 5/8"IP20, IP50
    38615K1730000000
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"15/16"3 13/16"IP20, IP50
    38615K77000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K186000000
    B, E, J, K, L, N, R, S, T2Heating—1 4 mA to 20 mA Analog Signal
    Cooling—1 4 mA to 20 mA Analog Signal
    Thermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K187000000
    B, E, J, K, L, N, R, S, T2Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    SPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"1 7/8"2 3/8"IP20, IP50
    38615K82000000
     
    For 1/8 DIN Panel Cutout Size–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K193000000
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2501 7/8"3 3/4"2 3/8"IP20, IP50
    38615K88000000
     
    For 1/8 DIN Panel Cutout Size–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K196000000
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 3/4"1 7/8"2 3/8"IP20, IP50
    38615K85000000
     
    For 3/16 DIN Panel Cutout Size–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2502 27/32"2 27/32"2 3/8"IP20, IP50
    38615K273000000
    B, E, J, K, L, N, R, S, T3Heating—1 4 mA to 20 mA Analog Signal
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2502 9/16"2 7/8"2 3/8"IP20, IP50
    38615K92000000
     
    For 1/4 DIN Panel Cutout Size–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K285000000
    B, E, J, K, L, N, R, S, T2Heating—1 4 mA to 20 mA Analog Signal
    Cooling—1 4 mA to 20 mA Analog Signal
    Thermocouple, RTDAutomatic90 to 2503 3/4"3 3/4"2 3/8"IP20, IP50
    38615K286000000
     
    Accessories for Temperature Controllers

    Bench-Top Autotuning Temperature Controllers

    Built into an enclosure, these temperature controllers are protected when sitting on your workbench. Ideal in systems with rapid, unpredictable, or complex temperature changes, they turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. All work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting it. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. These controllers read temperature with a highly sensitive thermocouple probe in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. Use the keypad to adjust the actuation point, reset point, and other settings.
    The controllers have mechanical relay outputs that actuate circuits directly. All are single pole, single throw (SPST-NO) relays and turn one circuit from off to on (normally open).
    Controllers with 1 Control Zone
    Image of Product. Front orientation. Temperature Controllers. Bench-Top Autotuning Temperature Controllers, Controllers with 1 Control Zone.
    Image of Specification. Front orientation. NEMA 5-20. Bench-Top Autotuning Temperature Controllers, Controllers with 1 Control Zone.

    NEMA

    5-20

    Image of Specification. Front orientation. NEMA 6-20. Bench-Top Autotuning Temperature Controllers.

    NEMA

    6-20

    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset
    Type
    Input Voltage,
    V AC
    NEMA
    Type
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    J
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 120V ACAutomatic1205-20
    55"5"11"IP50
    1797N110000000
    J
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 240V ACAutomatic2406-20
    55"5"11"IP50
    1797N12000000
    K
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 120V ACAutomatic1205-20
    55"5"11"IP50
    1797N101000000
    K
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 240V ACAutomatic2406-20
    55"5"11"IP50
    1797N102000000
    Controllers with 1 Control Zone and High-Limit Control
    Image of Product. Front orientation. Temperature Controllers. Bench-Top Autotuning Temperature Controllers, Controllers with 1 Control Zone and High-Limit Control.
    Controllers with high-limit control let you attach a second thermocouple probe to take the temperature of your heating equipment. If your equipment reaches the high limit, these controllers shut down your heating equipment and won't let it turn back on until you manually reset it, improving the safety of your system.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset Type
    Input Voltage,
    V AC
    NEMA
    Type
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    J—Heating
    K—High-Limit Control
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 120V ACAutomatic, Manual1205-20
    55"8 1/2"11"IP50
    1797N105000000000
    K—Heating
    K—High-Limit Control
    1Heating—1 Mechanical RelaySPST-NO
    16 amp @ 120V ACAutomatic, Manual1205-20
    55"8 1/2"11"IP50
    1797N10600000000
    Controllers with 2 Control Zones
    Image of Product. Front orientation. Temperature Controllers. Bench-Top Autotuning Temperature Controllers, Controllers with 2 Control Zones.
    Controllers with two control zones let you independently turn heating equipment on and off in two separate areas, each with their own thermocouple input and heating control output.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset
    Type
    Input Voltage,
    V AC
    NEMA
    Type
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    J
    2Heating—2 Mechanical RelaysSPST-NO
    8 amp @ 120V ACAutomatic1205-20
    55"8 1/2"11"IP50
    1797N103000000000
    K
    2Heating—2 Mechanical RelaysSPST-NO
    8 amp @ 120V ACAutomatic1205-20
    55"8 1/2"11"IP50
    1797N10400000000

    High-Limit Temperature Controllers

    To protect equipment and personnel, these controllers shut down your machine when it gets too hot. Reset them manually to turn your machine on again. They're often used as a fail-safe system and for triggering alarms.
    Set the actuation point and adjust other settings with the keypad. To read the temperature, these controllers use a highly sensitive thermocouple probe (sold separately). They have one or two mechanical relays that actuate circuits directly. Mount them into instrumentation panels with DIN cutouts.
    Mechanical Relay Output
    Image of Product. Front orientation. Temperature Controllers. High-Limit Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. High-Limit Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 1/16 DIN Panel

    Cutout Size

    For 1/4 DIN Panel

    Cutout Size

    SPDT—Controllers that are SPDT (single pole, double throw) can turn one circuit from off to on (normally open) or on to off (normally closed).
    SPST-NO—Controllers that are SPST-NO (single pole, single throw) can turn one circuit from off to on (normally open).
    Remote Reset—Remote-reset controllers are best for hard-to-reach locations. To operate, you’ll need to wire the remote reset input terminals, and the sensor must be below the set temperature.
    Mechanical Relay
    For Thermocouple Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe
    Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Features
    Each
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    B, C, E, J, K, L, N, PL-II, R, S, T1Heating—1 Mechanical RelaySPDT
    2 amp @ 240V ACThermocoupleManual90 to 2641 7/8"1 7/8"3 3/4"IP20, IP30
    Indicator Icons, Remote Reset5916N110000000
    B, C, E, J, K, L, N, PL-II, R, S, T2Heating—1 Mechanical Relay
    Heating—1 Mechanical Relay
    SPDT
    SPST-NO
    2 amp @ 240V ACThermocoupleManual90 to 2641 7/8"1 7/8"3 3/4"IP20, IP30
    5916N13000000
     
    For 1/4 DIN Panel Cutout Size–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout
    B, C, E, J, K, L, N, PL-II, R, S, T2Heating—1 Mechanical Relay
    Heating—1 Mechanical Relay
    SPDT2 amp @ 240V ACThermocoupleManual90 to 2503 3/4"3 3/4"2 9/16"IP20, IP30
    Remote Reset5916N12000000
     
    Accessories for Temperature Controllers

    DIN-Rail-Mount Autotuning Temperature Controllers

    Image of ProductInUse. Front orientation. Temperature Controllers. DIN-Rail-Mount Autotuning Temperature Controllers.
    Mount these temperature controllers directly onto DIN rail for controlling systems with rapid, unpredictable, or complex temperature changes. They turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. All work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. These controllers read temperature with a highly sensitive thermocouple or RTD probe (both not included) in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. Use the keypad to adjust the actuation point, reset point, and other settings.
    All meet American, Canadian, and European safety standards.
    Mechanical Relay Output
    Mechanical relay outputs actuate circuits directly. All are single pole, single throw (SPST) relays and turn one circuit from off to on (normally open).
    For Alarming and For Cooling—Those with cooling/alarm outputs can also be used to turn cooling equipment on or off at a specified temperature.
    For Alarming—Alarm outputs can be configured to actuate alarms or other simple devices.
    Mechanical Relay
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    B, E, J, K, L, N, R, S, T1Heating—1 Mechanical RelaySPST-NO
    2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 25/32"7/8"3 1/8"NEMA 1
    5705N110000000
    B, E, J, K, L, N, R, S, T3Heating—1 Mechanical Relay
    Cooling/Alarming—1 Mechanical Relay
    Alarming—1 Mechanical Relay
    SPST-NO2 amp @ 240V ACThermocouple, RTDAutomatic90 to 2503 25/32"7/8"3 1/8"NEMA 1
    5705N12000000
     
    Solid State Relay Output
    Solid state relay outputs send a pulse signal to directly control an external solid state relay (not included). They last longer than mechanical and analog signal relays. Use them for more precise and rapid control switching than mechanical relays.
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    B, E, J, K, L, N, R, S, T1Heating—1 14V DC Solid State RelayThermocouple, RTDAutomatic90 to 2503 25/32"7/8"3 1/8"NEMA 1
    5705N130000000
     
    Analog Signal Output
    Analog signal outputs are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    For Probe Type
    Reset
    Type
    Input Voltage
    Range, V AC
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    B, E, J, K, L, N, R, S, T1Heating—1 4 mA to 20 mA Analog SignalThermocouple, RTDAutomatic90 to 2503 25/32"7/8"3 1/8"NEMA 1
    5705N140000000
     
    back to top