About Safety Ratings for Electrical Testing
More
Data-Logging Hand-Held Thermometers
Measure and store temperature readings and upload the data to a PC.
Thermometers with a USB output transfer data through your PC’s USB port.
For easy upload, thermometers with an SD memory card store readings in Excel format.
Thermometers | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Probe | Replacement Probes | |||||||||||||
No. of Probe Inputs | Temperature Range | Resolution | Accuracy | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Features | Specifications Met | Batteries Included | Each | Each | ||
For Use With Air, Gases, Surfaces | ||||||||||||||
Thermometers | ||||||||||||||
1 | -22° to 158° F/ -30° to 70° C | 0.1/ 0.1 | ±1° F/ ±0.5° C | 30 | 3 | 3/4" | 3/16" | USB Output, Min./Max. Memory, LED Status Light | CE Marked | Yes | 0000000 | 0000000 | 0000000 | 000000 |
2 | -22° to 572° F/ -30° to 300° C | 0.1/ 0.1 | ±1.75° F/ ±0.90° C | 1.5 | 3 | 1/8" | 3/16" | Auto Power Off, Backlit Display, Built-In Stand, Min./Max. Memory, Real-Time Clock | CE Marked | Yes | 0000000 | 000000 | 0000000 | 00000 |
Thermometers with SD Memory Card | ||||||||||||||
3 | -40° to 482° F/ -40° to 250° C | 0.1/ 0.1 | ±12.86° F/ ±7° C | 1 | 3 | 1/8" | 3/16" | Backlit Display, Built-In Stand, Real-Time Clock | CE Marked | Yes | 0000000 | 000000 | 0000000 | 00000 |
4 | -40° to 482° F/ -40° to 250° C | 0.1/ 0.1 | ±5.8° F/ ±4.4° C | 1 | 3 | 1/8" | 3/16" | Auto Power Off, Backlit Display, Built-In Stand, Min./Max. Memory, Real-Time Clock | CE Marked | Yes | 0000000 | 000000 | 0000000 | 00000 |
12 | -40° to 482° F/ -40° to 250° C | 0.1/ 0.1 | ±1.8° F/ ±1° C | 1 | 3 | 1/8" | 3/16" | Auto Power Off, Backlit Display, Data Logging Capabilities | CE Marked | Yes | 0000000 | 00000000 | 0000000 | 00000 |
Fluke High-Accuracy Data-Logging Thermometers
Store up to 500 readings on these thermometers and determine temperature within ±0.75° F accuracy.
Thermometers with NIST certificate include a calibration certificate traceable to NIST that states the thermometer has passed a test for accuracy.
The optional type K probe (sold separately) connects to your thermometer to measure temperatures up to 537° C or 1000° F.
Probe | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Probe Inputs | Temperature Range | Resolution | Accuracy | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Manufacturer Part No. | Specifications Met | Batteries Included | Each | |
Thermometers | ||||||||||||
For Use With Air, Gases, Solids, Surfaces | ||||||||||||
1 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.4° C | 2 | 3.25 | 3/16" | 1/16" | 53-2B | CE Marked, CSA Certified | Yes | 00000000 | 0000000 |
2 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.4° C | 2 | 3.25 | 3/16" | 1/16" | 54-2B | CE Marked, CSA Certified | Yes | 00000000 | 000000 |
Thermometers with NIST Certificate | ||||||||||||
For Use With Air, Gases, Solids, Surfaces | ||||||||||||
1 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.4° C | 2 | 3.25 | 3/16" | 1/16" | 53-2B | CE Marked, CSA Certified | Yes | 00000000 | 000000 |
2 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.4° C | 2 | 3.25 | 3/16" | 1/16" | 54-2B | CE Marked, CSA Certified | Yes | 00000000 | 00000000 |
Optional Type K Probe (8 3/8" Lg.) | 00000000 | Each | 0000000 |
Extended-Life Data-Logging Thermometers
For more accurate and consistent readings than thermometers with thermocouple probes and a longer service life, this thermometer has a resistance temperature detector (RTD) probe. It logs up to 2,000 time- and date-stamped readings and uploads data to a PC through the USB port.
To conserve battery life, use the optional power adapter (sold separately).
Probe | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Length, ft. | Lg. | Dia. | Specifications Met | Batteries Included | Each | |
For Use With Air, Gases, Liquids, Solids, Surfaces | |||||||||||
-58° to 932° F/-50° to 500° C | 0.1/0.1 | ±0.1° F/±0.1° C | 1 | 10 | 5 | 4" | 3/16" | CE Marked | Yes | 00000000 | 000000000 |
Fluke High-Accuracy Hand-Held Thermometers
Designed for laboratory applications, these thermometers determine temperature within ±0.75° F accuracy.
Thermometers with NIST certificate include a calibration certificate traceable to NIST that states the thermometer has passed a test for accuracy.
The optional type K probe (sold separately) connects to your thermometer to measure temperatures up to 537° C or 1000° F.
Probe | Thermometers with NIST Certificate | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Probe Inputs | Temperature Range | Resolution | Accuracy | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Manufacturer Part No. | Specifications Met | Batteries Included | Each | |
For Use With Air, Gases, Solids, Surfaces | ||||||||||||
1 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.45° C | 2 | 3.25 | 3/16" | 1/16" | 51-2 | CE Marked, CSA Certified | Yes | 00000000 | 0000000 |
2 | -40° to 500° F/-40° to 260° C/233 to 533 K | 0.1/0.1/0.1 | ±0.75° F/±0.45° C | 2 | 3.25 | 3/16" | 1/16" | 52-2 | CE Marked, CSA Certified | Yes | 00000000 | 000000 |
Optional Type K Probe (8 3/8" Lg.) | 00000000 | Each | 0000000 |
Quick-Export Temperature and Humidity Data Recorders
No cords or software required—these data recorders store readings on an included SD card in Excel format for easy transfer to a PC.
Data recorders with a NIST certificate of calibration include a calibration certificate traceable to NIST that states the recorder has passed a test for accuracy.
Recording Interval | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Display | Digit Ht. | Temp. Range | Temp. Accuracy | Relative Humidity Range | Relative Humidity Accuracy | Min. | Max. | Ht. | Wd. | Dp. | Batteries Included | Each | |
Temperature and Humidity Data Recorders | |||||||||||||
LCD | 1/2" | 32° to 122° F/0° to 50° C | ±1.5° F/±0.8° C | 10 to 90% | ±4% | Once per Five Seconds | Once per 600 Seconds | 5 3/16" | 3 1/16" | 1 5/16" | Yes | 000000 | 0000000 |
Temperature and Humidity Data Recorders with NIST Certificate | |||||||||||||
LCD | 1/2" | 32° to 122° F/0° to 50° C | ±1.5° F/±0.8° C | 10 to 90% | ±4% | Once per Five Seconds | Once per 600 Seconds | 5 3/16" | 3 1/16" | 1 5/16" | Yes | 000000 | 000000 |
Remote-Reading Temperature and Pressure Data Recorders
Monitor temperature and pressure in hard-to-access system components with this data recorder that has remote sensors that track and store readings for upload to a PC. It requires software and a USB cord (not included).
Recording Interval | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Temp. Accuracy | Pressure Range | Pressure Accuracy | Min. | Max. | Ht. | Wd. | Dp. | Battery Size | No. of Batteries Required | Batteries Included | Each | |
-40° to 150°F/-40° to 65°C | ±1º F/±0.5° C | 0 to 500 psi | ±3 psi | Once per Second | Once per 18 Hours | 2 1/2" | 3" | 1 3/32" | 9V | 1 | No | 0000000 | 0000000 |
Software and USB Cord | 0000000 | Each | 000000 |
Charts for Temperature and Humidity Chart Recorders
Chart Dia. | Temp. Range, °F | Temp. Range, °C | Recording Time | Pkg. Qty. | Pkg. | |
8" | -50° to 50° | -50° to 50° | 24 hrs. | 60 | 000000000 | 000000 |
8" | -50° to 50° | -50° to 50° | 7 days | 60 | 000000000 | 00000 |
8" | 0° to 250° | 0° to 250° | 24 hrs. | 60 | 000000000 | 00000 |
8" | 0° to 250° | 0° to 250° | 7 days | 60 | 000000000 | 00000 |
8" | 0° to 500° | 0° to 500° | 24 hrs. | 60 | 000000000 | 00000 |
8" | 0° to 500° | 0° to 500° | 7 days | 60 | 000000000 | 00000 |
Compact Temperature Chart Recorders
About half the size of standard temperature chart recorders, these are often used to monitor temperature inside refrigerators, incubators, storage compartments, and other small spaces. They have a built-in sensor, so no probe is needed. Charts (not included) are required.
Chart Dia. | Temp. Range, ° F | Recording Time, days | Pkg. Qty. | Pkg. | |
Fahrenheit | |||||
---|---|---|---|---|---|
4" | -22° to 122° | 7 | 60 | 000000000 | 000000 |
Remote-Reading Temperature Chart Recorders with High/Low Alarm
To alert you of temperature fluctuations, these recorders sound an alarm and flash the display when temperature rises above or falls below the programmable temperature range. They have a thermocouple type-K probe on a 4-ft. cable for taking readings in hard-to-access areas. Charts (not included) are required; select a recording time and temperature range from the available chart options.
Note: Thermocouple probes are not interchangeable with RTD probes.
Probe extension cable extends the probe's reach by 10 feet.
Chart Dia. | Temp. Range, ° F | Temp. Range, °C | Recording Time | Pkg. Qty. | Pkg. | |
Fahrenheit/Celsius | ||||||
---|---|---|---|---|---|---|
8" | -50° to 50° | -50° to 50° | 24 hrs. | 60 | 000000000 | 000000 |
8" | -50° to 50° | -50° to 50° | 7 days | 60 | 000000000 | 00000 |
8" | 0° to 100° | 0° to 100° | 24 hrs. | 60 | 000000000 | 00000 |
8" | 0° to 100° | 0° to 100° | 7 days | 60 | 000000000 | 00000 |
8" | 0° to 250° | 0° to 250° | 24 hrs. | 60 | 000000000 | 00000 |
8" | 0° to 250° | 0° to 250° | 7 days | 60 | 000000000 | 00000 |
8" | 0° to 500° | 0° to 500° | 24 hrs. | 60 | 000000000 | 00000 |
8" | 0° to 500° | 0° to 500° | 7 days | 60 | 000000000 | 00000 |
Temperature and Humidity Chart Recorders with Calibration Certificate
Track ambient temperature and humidity over time with this recorder that includes a calibration certificate traceable to NIST that states it has passed a test for accuracy. Recorders come with a replaceable sensor, so no probe is needed. Charts (not included) are required; select a recording time and temperature range from the available chart options.
For Chart Dia. | For Recording Time | Temp. Accuracy | Relative Humidity Range | Relative Humidity Accuracy | Ht. | Wd. | Dp. | Features | Batteries Included | Fasteners Included | Each | |
8" | 24 hrs., 7 days | ±1.8° F/±1° C | 0 to 95% | ±2% | 10 1/8" | 9 3/8" | 2 3/4" | Audible High/Low Alarm, Min./Max. Display, Visual High/Low Alarm | Yes | No | 00000000 | 0000000 |
Remote-Reading Temperature, Humidity, and
Dew Point Chart Recorders with High/Low Alarm
Remotely record temperature, humidity, and dew point up to 10 feet from the display and set the alarm to sound and flash the display if temperature readings rise above or fall below a set range. This recorder has a remote probe on a 10-ft. cable and a display that can be set to show current temperature, minimum/maximum temperature, or relative humidity and calculated dew point. Charts (not included) are required; select a recording time and temperature range from the available chart options.
For Chart Dia. | For Recording Time | Temp. Accuracy | Relative Humidity Range | Relative Humidity Accuracy | Dew Point Range | Dew Point Accuracy | AC Voltage | Ht. | Wd. | Dp. | Batteries Included | Fasteners Included | Each | |
8" | 24 hrs., 7 days | ±1.8° F/±1° C | 0 to 95% | ±2% | 32° to 120° F/0° to 50° C | ±3.6° F/±2° C | 120 | 10 1/8" | 9 3/8" | 2 3/4" | Yes | No | 00000000 | 0000000 |
Replacement Blue Pen | 00000000 | Each | 000000 |
Remote-Reading Temperature Chart Recorders
Record temperature in hard-to-access areas. These recorders have a remote thermocouple type-J probe on a 15-ft. cable. They include 60 assorted charts with a variety of recording times and temperature ranges.
Note: Thermocouple probes are not interchangeable with RTD probes.
Scale | For Chart Dia. | For Recording Time | Includes | AC Voltage | Ht. | Wd. | Dp. | Specifications Met | Battery Size | No. of Batteries Required | Batteries Included | Mounting Hole Dia. (No. of) | Fasteners Included | Each | |
Fahrenheit | 6" | 6 hrs., 24 hrs., 7 days | 2 Black Pens, 60 6" Charts | 120 | 9 1/4" | 7 1/4" | 2 3/4" | CE Marked | AA | 8 | No | 1/2" (2) | No | 00000000 | 0000000 |
Celsius | 6" | 6 hrs., 24 hrs., 7 days | 2 Black Pens, 60 6" Charts | 120 | 9 1/4" | 7 1/4" | 2 3/4" | CE Marked | AA | 8 | No | 1/2" (2) | No | 00000000 | 000000 |
Replacement Black Pen | 0000000 | Each | 000000 |
Fluke Data-Logging Multimeters
Record measurements from electrical tests over time to identify intermittent issues such as voltage spikes and temporary power flow problems. Review data captured by these high-quality and durable Fluke multimeters in real-time or save it for future analysis.
To download and analyze data on a computer, software is required (not included).
These true RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. These 50,000-count multimeters show numbers up to 49,999.
Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Manufacturer Model Number | Data Log Capacity | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Max. DC Current, A | Hardware Features | Display Count | Includes | Each | |
Multimeters | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||
287 | 10,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 0000000 |
289 | 15,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Low Impedance, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 000000 |
Multimeters with Calibration Certificate | |||||||||||||
True RMS AC Calculation | |||||||||||||
287 | 10,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 000000 |
289 | 15,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Low Impedance, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | Overload Protection | 50,000 | Alligator Clips, Test Leads | 0000000 | 00000000 |
Download and analyze data from a Fluke data-logging multimeter. Connect your multimeter to a computer with the included USB cord.
Manufacturer Model Number | For Fluke Model Number | For Operating System | Each | |
FVF-SC2 | 287, 289 | Windows 7 and earlier | 0000000 | 0000000 |
Data-Logging Multimeters
Identify intermittent issues such as voltage spikes and temporary power flow problems—this meter records measurements from electrical tests over time. Review data in real time or save it for future analysis.
This true RMS multimeter takes accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display count is an industry designation and not an actual value. This 10,000-count multimeter shows numbers up to 9,999.
Data Log Capacity | Safety Rating | Measures | Max. AC Voltage | Max. DC Voltage | DC Voltage Accuracy | Max. AC Current, A | Max. DC Current, A | Display Count | Includes | Each | |
True RMS AC Calculation | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
50,000 | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 0.025% | 10 | 10 | 10,000 | Alligator Clips, Test Leads | 0000000 | 0000000 |
Pressure Data Recorders with Digital Display
Also known as data loggers, these recorders track and store up to 64,000 data samples that you can upload to your computer using a USB connection or a flash drive. Recorders are rated IP68 for protection against water submersion. The LCD shows pressure for local readings. Software (sold separately) is compatible with Windows 98 or better and must be used with a PC that has a USB port. It can be used with more than one recorder.
Pressure Range, psi | Resolution, psi | Sampling Interval | Response Time, sec. | No. of Data Samples | Temp. Range, °F | Pipe Size | Thread Type | Gender | Connection Material | Dia. | Dp. | Digit Ht. | Batteries Included | For Use With | Environmental Rating | Each | |
Polycarbonate Plastic Housing—Polycarbonate Plastic Lens | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0-100 | 0.1 | 1 sec.-24 hrs. | 45 | 64,000 | 0° to 155° | 1/4 | NPT | Male | 316 Stainless Steel | 3 3/8" | 2 13/16" | 9/16" | Yes | Air, Water | IP68 | 0000000 | 0000000 |
0-300 | 0.1 | 1 sec.-24 hrs. | 45 | 64,000 | 0° to 155° | 1/4 | NPT | Male | 316 Stainless Steel | 3 3/8" | 2 13/16" | 9/16" | Yes | Air, Water | IP68 | 0000000 | 000000 |
0-500 | 0.1 | 1 sec.-24 hrs. | 45 | 64,000 | 0° to 155° | 1/4 | NPT | Male | 316 Stainless Steel | 3 3/8" | 2 13/16" | 9/16" | Yes | Air, Water | IP68 | 0000000 | 000000 |
Software and USB Cord | 0000000 | Each | 000000 |
Pressure Chart Recorders
Measure and record pressure on a paper chart to troubleshoot system problems and track important process parameters. Recorders are rated NEMA 4X for protection from dirt, washdowns, and corrosion. Charts are sold separately.
Pressure Range, psi | Response Time, sec. | Accuracy | Temp. Range, °F | Pipe Size | Thread Type | Gender | Connection Material | Ht. | Wd. | Dp. | Batteries Included | Includes | For Use With | Environmental Rating | Each | |
4" Chart Dia. | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For 24 hr. and 7 day Recording | ||||||||||||||||
0-100 | 1 | ±2% | -20° to 120° | 1/4 | NPT | Male | Brass | 6 1/4" | 6" | 2 7/8" | Yes | Red Pen | Air, Argon, Hydraulic Fluid, Nitrogen, Water | IP66, NEMA 4X | 0000000 | 0000000 |
0-200 | 1 | ±2% | -20° to 120° | 1/4 | NPT | Male | Brass | 6 1/4" | 6" | 2 7/8" | Yes | Red Pen | Air, Argon, Hydraulic Fluid, Nitrogen, Water | IP66, NEMA 4X | 0000000 | 000000 |
0-300 | 1 | ±2% | -20° to 120° | 1/4 | NPT | Male | Brass | 6 1/4" | 6" | 2 7/8" | Yes | Red Pen | Air, Argon, Hydraulic Fluid, Nitrogen, Water | IP66, NEMA 4X | 0000000 | 000000 |
0-500 | 1 | ±2% | -20° to 120° | 1/4 | NPT | Male | Brass | 6 1/4" | 6" | 2 7/8" | Yes | Red Pen | Air, Argon, Hydraulic Fluid, Nitrogen, Water | IP66, NEMA 4X | 0000000 | 000000 |
8" Chart Dia. | ||||||||||||||||
For 24 hr. Recording | ||||||||||||||||
0-200 | 5 | ±2% | -20° to 120° | 1/4 | NPT | Male | Brass | 10 5/16" | 9 1/2" | 3 19/32" | Yes | Red Pen | Air, Argon, Hydraulic Fluid, Nitrogen, Water | IP66, NEMA 4X | 000000000 | 000000 |
0-1,000 | 5 | ±2% | -20° to 120° | 1/4 | NPT | Male | Brass | 10 5/16" | 9 1/2" | 3 19/32" | Yes | Red Pen | Air, Argon, Hydraulic Fluid, Nitrogen, Water | IP66, NEMA 4X | 0000000 | 00000000 |
For 7 day Recording | ||||||||||||||||
0-200 | 5 | ±2% | -20° to 120° | 1/4 | NPT | Male | Brass | 10 5/16" | 9 1/2" | 3 19/32" | Yes | Red Pen | Air, Argon, Hydraulic Fluid, Nitrogen, Water | IP66, NEMA 4X | 000000000 | 000000 |
For 24 hr. Recording | For 7 day Recording | |||||
---|---|---|---|---|---|---|
For Pressure Range, psi | Pkg. Qty. | Pkg. | Pkg. Qty. | Pkg. | ||
4" Dia. | ||||||
0-100 | 60 | 00000000 | 000000 | 60 | 00000000 | 000000 |
0-200 | 60 | 00000000 | 00000 | 60 | 00000000 | 00000 |
0-300 | 60 | 00000000 | 00000 | 60 | 00000000 | 00000 |
0-500 | 60 | 00000000 | 00000 | 60 | 00000000 | 00000 |
8" Dia. | ||||||
0-200 | 60 | 000000000 | 00000 | 60 | 000000000 | 00000 |
0-1,000 | 60 | 000000000 | 00000 | __ | 000000 | 00 |
Color | Each | |
Red | 0000000 | 000000 |