High-Temperature Panel-Mount Thermometers
Often used to remotely monitor probe readings in high-temperature applications, these thermometers have a housing designed for installation in instrument and control panels. They interpret data from a thermocouple probe or RTD probe (sold separately).
For technical drawings and 3-D models, click on a part number.
For Panel Cutout | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | For Thermocouple Probe Type | For RTD Probe Type | DIN Trade Size | Ht. | Wd. | Ht. | Wd. | Dp. | Electrical Connection | Frequency, Hz | Each | |
-2° to 752° F | 1 | ±3.3° F | K | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 0000000 |
0° to 1,000° F | 1 | ±5.0° F | J | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
0° to 1,999° F | 1 | ±10.0° F | K | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
32° to 428° F | 1 | ±2.8° F | J | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
-346° to 1,400° F/-210° to 760° C | 1 | ±3.7° F | J | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
-157° to 752° F/-105° to 400° C | 1 | ±3.7° F | T | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
-157° to 1,999° F/-105° to 1,372° C | 1 | ±3.7° F | K | __ | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
-58° to 200° F/-50° to 199° C | 0.1 | ±0.3° F | __ | 100 ohms | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
-58° to 1,562° F/-50° to 850° C | 1 | ±2.0° F | __ | 100 ohms | 1/8 | 1 25/32" | 3 5/8" | 1 7/8" | 3 3/4" | 4 5/8" | Screw Terminals | 60 | 0000000 | 000000 |
Miniature Remote-Reading Panel-Mount Thermometers
Install the small display in tight spaces and crowded instrument panels up to 10 feet from the probe.
Probe | Mtg. Holes | For Panel Cutout | Material | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | Lg. | Dia. | No. of | Dia. | Fasteners Included | Ht. | Wd. | Ht. | Wd. | Dp. | Housing | Probe | Batteries Included | Each | |
-40° to 300° F/ -40° to 150° C | 0.1/0.1 | ±1.8° F | 7/8" | 3/16" | 2 | 5/32" | No | 1 1/2" | 2 3/4" | 1 5/8" | 2 15/16" | 1" | Plastic | Stainless Steel | Yes | 0000000 | 000000 |
14° to 230° F/ -10° to 110° C | 0.1/0.1 | ±1° F | 20" | 3/16" | 2 | 3/8" | No | 3 3/4" | 4 3/4" | 3 5/16" | 4 3/4" | 1 1/4" | Plastic | Stainless Steel | Yes | 0000000 | 000000 |
Remote-Reading Panel-Mount Thermometers
Monitor the temperature of difficult-to-access system components from a distance. The probe is connected to a cable, so the dial can be mounted away from your system.
Thermometers that meet NSF/ANSI standards are for use in food processing and preparation areas.
Probe | Mtg. Holes | Material | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dial Dia. | Cable Lg., ft. | Lg. | Dia. | Panel Cutout Dia. | Flange OD | Bolt Circle Dia. | No. of | Dia. | Housing | Probe | Temperature Range | Specifications Met | Each | |
Front Flange Mount | ||||||||||||||
2" | 4 | 2 1/2" | 0.312" | 3" | 3" | 2 5/8" | 3 | 5/32" | Stainless Steel | Tin-Plated Copper | -40° to 60° F/-40° to 15° C | NSF/ANSI 2 | 00000000 | 000000 |
2" | 4 | 2 1/2" | 3/8" | 2 1/16" | 2 15/16" | 2 9/16" | 3 | 5/32" | Stainless Steel | Nickel Plated Copper | 40° to 240° F/0° to 115° C | NSF/ANSI 2 | 00000000 | 00000 |
2" | 20 | 4" | 3/8" | 3" | 3" | 2 5/8" | 3 | 5/32" | Stainless Steel | Tin-Plated Copper | -40° to 60° F/-40° to 15° C | __ | 00000000 | 00000 |
2 1/2" | 4 | 2 1/2" | 0.312" | 3 1/2" | 3 1/2" | 2 5/8" | 3 | 5/32" | Stainless Steel | Tin-Plated Copper | -40° to 60° F/-40° to 15° C | NSF/ANSI 2 | 00000000 | 00000 |
2 1/2" | 4 | 2 1/2" | 3/8" | 2 5/8" | 3 1/2" | 3 3/16" | 3 | 5/32" | Stainless Steel | Nickel Plated Copper | -40° to 110° F/-40° to 43° C | __ | 00000000 | 00000 |
2 1/2" | 4 | 2 1/2" | 3/8" | 2 5/8" | 3 1/2" | 3 3/16" | 3 | 5/32" | Stainless Steel | Nickel Plated Copper | 40° to 240° F/0° to 115° C | NSF/ANSI 2 | 00000000 | 00000 |
Back Flange Mount | ||||||||||||||
2" | 4 | 2 1/2" | 0.314" | 3 1/2" | 3" | 2 5/8" | 3 | 5/32" | Stainless Steel | Tin-Plated Copper | -40° to 60° F/-40° to 15° C | NSF/ANSI 2 | 00000000 | 00000 |
2" | 4 | 2 1/2" | 3/8" | 2 1/16" | 2 15/16" | 2 9/16" | 3 | 9/64" | Stainless Steel | Nickel Plated Copper | -40° to 110° F/-40° to 43° C | NSF/ANSI 2 | 00000000 | 00000 |
2" | 4 | 2 1/2" | 3/8" | 2 1/16" | 3 1/2" | 3 3/16" | 3 | 5/32" | Stainless Steel | Nickel Plated Copper | 40° to 240° F/0° to 115° C | NSF/ANSI 2 | 00000000 | 00000 |
2 1/2" | 4 | 2 1/2" | 3/8" | 2 5/8" | 3 1/2" | 3 3/16" | 3 | 11/64" | Stainless Steel | Nickel Plated Copper | -40° to 110° F/-40° to 43° C | __ | 00000000 | 00000 |
4 1/2" | 4 | 3 1/2" | 3/8" | 4 5/8" | 5 7/8" | 5 3/8" | 3 | 7/32" | Stainless Steel | Nickel Plated Copper | -40° to 110° F/-40° to 43° C | __ | 00000000 | 000000 |
4 1/2" | 4 | 3 1/2" | 3/8" | 4 5/8" | 5 7/8" | 5 3/8" | 3 | 7/32" | Stainless Steel | Nickel Plated Copper | 40° to 240° F/0° to 115° C | __ | 00000000 | 000000 |
Bracket Mount | ||||||||||||||
2 1/2" | 4 | 2 1/2" | 3/8" | __ | __ | __ | 1 | 11/64" | Stainless Steel | Nickel Plated Copper | -40° to 60° F/-40° to 15° C | NSF/ANSI 2 | 00000000 | 00000 |
Remote-Reading Panel-Mount Freezer Thermometers with Audible Alarm
Protect temperature-sensitive materials in refrigerators and freezers with one of these thermometers that sound an alarm and flash the display when temperature rises above your activation point. Alarm requires a power supply (sold separately).
Probe | Mtg. Holes | For Panel Cutout | Input Voltage | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Actuation Point Temperature Range | Resolution | Accuracy | Cable Lg., ft. | Dia. | Lg. | No. of | Dia. | Fasteners Included | Ht. | Wd. | Ht. | Wd. | AC | DC | Electrical Connection | Frequency, Hz | Each | |
-25° F to 99° F/-32° C to 38° C | -15° F to 50° F/-26° C to 10° C | 1/1 | ±3° F | 6 | 3/8" | 7/8" | 2 | 7/32" | No | 3 7/8" | 2 7/8" | 5" | 3 1/8" | 10.5 to 28 | 12 to 28 | Wire Leads | 60 | 000000 | 0000000 |
12V AC Output/120V AC Input Power Supply | 0000000 | Each | 000000 |
High-Accuracy Panel-Mount Thermometers with Calibration Certificate
Obtain the most accurate readings possible with these thermometers that include a calibration certificate traceable to NIST that states they’ve passed a test to fall within ±0.5° F accuracy. The thermometer probe is connected to a cable, so the display can be mounted away from your system for remote viewing.
For technical drawings and 3-D models, click on a part number.
Probe | Mtg. Holes | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cable Lg., ft. | Temperature Range, ° F | Resolution | Accuracy | Dial Dia. | Lg. | Dia. | Pipe Size | Thread Type | Gender | Flange OD | Bolt Circle Dia. | No. of | Dia. | Fasteners Included | Probe Material | Batteries Included | Each | |
Back Flange Mount | ||||||||||||||||||
5 | -75° to 750° | 0.1 | ±0.5° F | 4 1/2" | 4" | 1/4" | 1/2 | NPT | Male | 4 1/2" | 5 3/8" | 3 | 1/4" | No | Stainless Steel | Yes | 0000000 | 0000000 |
10 | -75° to 750° | 0.1 | ±0.5° F | 4 1/2" | 4" | 1/4" | 1/2 | NPT | Male | 4 1/2" | 5 3/8" | 3 | 1/4" | No | Stainless Steel | Yes | 0000000 | 000000 |
15 | -75° to 750° | 0.1 | ±0.5° F | 4 1/2" | 4" | 1/4" | 1/2 | NPT | Male | 4 1/2" | 5 3/8" | 3 | 1/4" | No | Stainless Steel | Yes | 0000000 | 000000 |
20 | -75° to 750° | 0.1 | ±0.5° F | 4 1/2" | 4" | 1/4" | 1/2 | NPT | Male | 4 1/2" | 5 3/8" | 3 | 1/4" | No | Stainless Steel | Yes | 0000000 | 000000 |
25 | -75° to 750° | 0.1 | ±0.5° F | 4 1/2" | 4" | 1/4" | 1/2 | NPT | Male | 4 1/2" | 5 3/8" | 3 | 1/4" | No | Stainless Steel | Yes | 0000000 | 000000 |
Panel-Mount Thermometers
For mounting on instrument and control panels, these thermometers have a back flange.
Stem | Mtg. Holes | Material | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Graduation Marks , °F | Accuracy | Lg. | Dia. | Dial Dia. | Flange OD | Bolt Circle Dia. | No. of | Dia. | Fasteners Included | Housing | Stem | Each | |
Back Flange Mount | ||||||||||||||
-40° to 160° F -40° to 70° C | 2° | ±4° F | 6" | 1/4" | 3" | 3 5/16" | 2 1/2" | 3 | 5/32" | No | Stainless Steel | Stainless Steel | 0000000 | 000000 |
-40° to 160° F | 2° | ±4° F | 9" | 1/4" | 2 1/2" | 3 5/16" | 3" | 3 | 5/32" | No | Stainless Steel | Stainless Steel | 0000000 | 00000 |
0° to 200° F -15° to 93° C | 2° | ±4° F | 4" | 1/4" | 3" | 3 5/16" | 2 1/2" | 3 | 5/32" | No | Stainless Steel | Stainless Steel | 0000000 | 00000 |
0° to 200° F | 2° | ±4° F | 6" | 1/4" | 2 1/2" | 3 5/16" | 3" | 3 | 5/32" | No | Stainless Steel | Stainless Steel | 0000000 | 00000 |
0° to 200° F | 2° | ±4° F | 9" | 1/4" | 2 1/2" | 3 5/16" | 3" | 3 | 5/32" | No | Stainless Steel | Stainless Steel | 0000000 | 00000 |
Quick-Response Food and Beverage Panel-Mount Thermometers
A resistance temperature detector (RTD) probe responds to temperature change faster than dial thermometers.
For technical drawings and 3-D models, click on a part number.
Probe | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | For RTD Probe Type | Cable Lg., ft. | Dia. | Lg. | Panel Cutout Dia. | AC Voltage | Electrical Connection | Response Time, sec. | Includes | Each | |
-40° to 250° F | 1 | ±2° F | 1,000 ohms | 8 | 1/4" | 2 5/8" | 2 3/32" | 120 | Plug | 1 | Bracket Assembly | 000000000 | 0000000 |
-40° to 120° C | 1 | ±2° C | 1,000 ohms | 8 | 1/4" | 2 5/8" | 2 3/32" | 120 | Plug | 1 | Bracket Assembly | 000000000 | 000000 |
Through-Wall Humidity and Temperature Meters
Monitor relative humidity, temperature, and dew point inside sealed containers. These meters are rated IP67, so they won't expose contents to dust and water. The housing is aluminum, which is lightweight and resists corrosion.
For technical drawings and 3-D models, click on a part number.
Relative Humidity | Temperature | Dew Point | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range | Accuracy | Indoor Range | Accuracy | Range | Accuracy | Dp. | Dia. | For Hole Dia. | For Max. Wall Thick. | Batteries Included | Fasteners Included | Environmental Rating | Each | |
5 to 80% | ±3% | -4° to 140° F/-20° to 60° C | ±1° F/±0.5° C | -22° to 68° F/-30° to 20° C | ±3.6° F/±2° C | 1 1/4" | 2 1/2" | 1 27/64" | 11/32" | Yes | Yes | IP67 | 0000000 | 0000000 |
High-Limit Temperature Controllers
To protect equipment and personnel, these controllers shut down your machine when it gets too hot. Reset them manually to turn your machine on again. They're often used as a fail-safe system and for triggering alarms.
Set the actuation point and adjust other settings with the keypad. To read the temperature, these controllers use a highly sensitive thermocouple probe (sold separately). They have one or two mechanical relays that actuate circuits directly. Mount them into instrumentation panels with DIN cutouts.
Controllers that are SPDT (single pole, double throw) can turn one circuit from off to on (normally open) or on to off (normally closed).
Controllers that are SPST-NO (single pole, single throw) can turn one circuit from off to on (normally open).
Remote-reset controllers are best for hard-to-reach locations. To operate, you’ll need to wire the remote reset input terminals, and the sensor must be below the set temperature.
To mount 1/16 DIN controllers to a surface or DIN rail, add DIN-rail/surface-mount adapters. To convert larger cutouts to fit 1/16 DIN controllers, add DIN cutout adapters.
Mechanical Relay | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Features | Each | |
1/16 DIN—For 1 3/4" Ht. x 1 3/4" Wd. Panel Cutout | ||||||||||
1 | Heating—One Mechanical Relay | SPDT | 2 A @ 240 V AC | Thermocouple | Manual | 90V AC to 264V AC | IP20, IP30 | Remote Reset | 0000000 | 0000000 |
2 | Heating—Two Mechanical Relays | SPST-NO SPDT | 2 A @ 240 V AC | Thermocouple | Manual | 90V AC to 264V AC | IP20, IP30 | __ | 0000000 | 000000 |
1/4 DIN—For 3 5/8" Ht. x 3 5/8" Wd. Panel Cutout | ||||||||||
2 | Heating—Two Mechanical Relays | SPDT | 2 A @ 240 V AC | Thermocouple | Manual | 90V AC to 250V AC | IP20, IP30 | Remote Reset | 0000000 | 000000 |
Mounting | ||||
---|---|---|---|---|
Fasteners Included | Screw Size | Number of Holes | Each | |
No | No. 6 | 2 | 000000000 | 000000 |
Proportional Temperature Controllers
Cycle heaters on and off intermittently to maintain a set temperature in your system. These proportional controllers keep your heater on when your system is below the set temperature, and they turn it off in short cycles when your system nears the set temperature. The short cycles make them more precise and allow less temperature fluctuation than on/off controllers. Use them on electric heaters only—they don't work with valves or solenoids.
Turn the dial on these controllers to choose your set temperature. They use a highly sensitive thermocouple probe (not included) to read temperature. Their mechanical relay actuates circuits directly. All are SPDT (single pole, double throw) and can turn one circuit from off to on (normally open) or on to off (normally closed). Install these controllers into instrument panels with DIN cutouts.
All controllers meet American, Canadian, and European safety standards.
To mount 1/16 DIN controllers to a surface or DIN rail, add DIN-rail/surface-mount adapters. To convert larger cutouts to fit 1/16 DIN controllers, add DIN cutout adapters.
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Temperature Control Range, °F | For Thermocouple Probe Type | Total No. of Outputs | Output Type | Industry Designation | Maximum Switching Current @ Voltage | Reset Type | Input Voltage | Each | |
1/16 DIN—For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
50° to 850° | J | 1 | Heating—One Mechanical Relay | SPDT | 5 A @ 240 V AC | Automatic | 200V AC to 240V AC | 0000000 | 0000000 |
1/4 DIN—For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout | |||||||||
50° to 850° | J | 1 | Heating—One Mechanical Relay | SPDT | 5 A @ 240 V AC | Automatic | 90V AC to 264V AC | 0000000 | 000000 |
Mounting | ||||
---|---|---|---|---|
Fasteners Included | Screw Size | Number of Holes | Each | |
No | No. 6 | 2 | 000000000 | 000000 |
Washdown Autotuning Temperature Controllers
The faceplate on these controllers is sealed to meet NEMA 4X and IP66 for protection in washdown environments with splashing water, corrosive liquid, and dust. The rear case meets IP20, which prevents objects about the size of a finger from coming into contact with a live circuit.
Because they have proportional-integral-derivative (PID) software, these controllers are ideal for turning heating equipment on and off in systems with rapid, unpredictable, and complex temperature changes. They help you achieve precise and stable temperature control with fuzzy logic that learns system behavior and automatically compensates for changes. Use the autotuning function to cycle and identify the ideal PID variables for your system to achieve the most precise control. These controllers read temperature with a highly sensitive thermocouple probe (sold separately) in critical process applications. All fit into instrument panels with DIN cutouts. Use the keypad to adjust the actuation point, reset point, and other settings.
Controllers with automatic reset switch off and on again automatically as the temperature fluctuates. Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
Mechanical relay outputs actuate circuits directly. Single pole, single throw (SPST) relays turn one circuit from off to on (normally open). Single pole, double throw (SPDT) relays can be set to turn the circuit from off to on (normally open) or from on to off (normally closed).
Solid state relay outputs send a pulse signal to directly control an external solid-state relay (not included). They have a longer service life than mechanical and signal relays. Use them for more precise and rapid control switching than mechanical relays.
Analog signal outputs send 4-20 mA current to actuate equipment on a current loop. They are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
DIN-rail/surface-mount adapters (sold separately) mount 1/16 DIN controllers to a surface.
DIN cutout adapters (sold separately) convert larger cutouts to fit 1/16 DIN controllers.
For technical drawings and 3-D models, click on a part number.
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/32 DIN—For 7/8" × 1 3/4" Panel Cutout | |||||||||
1 | Heating—One Mechanical Relay | Heating—SPST-NO | Heating—3 A @ 220 V AC | Thermocouple | Automatic | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 0000000 |
1/16 DIN—For 1 3/4" × 1 3/4" Panel Cutout | |||||||||
3 | Heating—One Mechanical Relay Alarm—Two Mechanical Relays | Heating—SPST-NO Alarm—SPST-NO | Heating—3 A @ 250 V AC Alarm—1 A @ 250 V AC | RTD, Thermocouple | Automatic, Manual | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 000000 |
1/8 DIN—For 3 3/4" × 1 3/4" Panel Cutout | |||||||||
3 | Heating—One Mechanical Relay Alarm—Two Mechanical Relays | Heating—SPDT Alarm—SPST-NO | Heating—5 A @ 250 V AC Alarm—1 A @ 250 V AC | RTD, Thermocouple | Automatic, Manual | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 000000 |
1/4 DIN—For 3 3/4" × 3 3/4" Panel Cutout | |||||||||
3 | Heating—One Mechanical Relay Alarm—Two Mechanical Relays | Heating—SPDT Alarm—SPST-NO | Heating—3 A @ 250 V AC Alarm—1 A @ 250 V AC | RTD, Thermocouple | Automatic, Manual | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 000000 |
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/32 DIN—For 7/8" × 1 3/4" Panel Cutout | |||||||||
1 | Heating—One 15V DC Solid State Relay Drive | __ | __ | Thermocouple | Automatic | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 0000000 |
1/16 DIN—For 1 3/4" × 1 3/4" Panel Cutout | |||||||||
3 | Heating—One 12V DC Solid State Relay Drive Alarm—Two Mechanical Relays | SPST-NO | 1 A @ 250 V AC | RTD, Thermocouple | Automatic, Manual | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 000000 |
1/8 DIN—For 3 3/4" × 1 3/4" Panel Cutout | |||||||||
3 | Heating—One 12V DC Solid State Relay Drive Alarm—Two Mechanical Relays | SPST-NO | 1 A @ 250 V AC | RTD, Thermocouple | Automatic, Manual | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 000000 |
1/4 DIN—For 3 3/4" × 3 3/4" Panel Cutout | |||||||||
3 | Heating—One 12V DC Solid State Relay Drive Alarm—Two Mechanical Relays | SPST-NO | 1 A @ 250 V AC | RTD, Thermocouple | Automatic, Manual | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 000000 |
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/16 DIN—For 1 3/4" × 1 3/4" Panel Cutout | |||||||||
3 | Heating—One 4-20 mA Analog Signal Alarm—Two Mechanical Relays | SPST-NO | 1 A @ 250 V AC | RTD, Thermocouple | Automatic, Manual | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 0000000 |
1/8 DIN—For 3 3/4" × 1 3/4" Panel Cutout | |||||||||
3 | Heating—One 4-20 mA Analog Signal Alarm—Two Mechanical Relays | SPST-NO | 1 A @ 250 V AC | RTD, Thermocouple | Automatic, Manual | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 000000 |
1/4 DIN—For 3 3/4" × 3 3/4" Panel Cutout | |||||||||
3 | Heating—One 4-20 mA Analog Signal Alarm—Two Mechanical Relays | SPST-NO | 1 A @ 250 V AC | RTD, Thermocouple | Automatic, Manual | 100V AC to 240V AC | IP20, IP66, NEMA 4X | 0000000 | 000000 |
Mounting | ||||
---|---|---|---|---|
Fasteners Included | Screw Size | No. of Holes | Each | |
No | No. 6 | 2 | 000000000 | 000000 |
Washdown On/Off Temperature Controllers
Rated IP65 and NEMA 4X to seal out water and dust, these temperature controllers turn your equipment on and off in areas with frequent washdowns. They're the simplest type of temperature controller, so they switch your heater or other device fully on or off without a middle state when they reach a given temperature. These controllers work great as alarms and in systems that can't handle rapid switching or have slow temperature changes. However, you shouldn't use them in processes that require precise control over temperatures.
To read temperature, these controllers use a highly sensitive thermocouple or RTD probe (not included). Their mechanical relay actuates circuits directly. All are SPDT (single pole, double throw) and can turn one circuit from off to on (normally open) or on to off (normally closed). Since these controllers reset automatically, they turn off and on again as the temperature fluctuates. Use the keypad to set the actuation point, reset point, and other settings. Mount them into instrument panel cutouts.
These controllers have UL recognized components and are CSA certified and CE marked, so they meet American, Canadian, and European safety standards.
Mechanical Relay | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Temperature Control Range | For Thermocouple Probe Type | Total No. of Outputs | Output Type | Industry Designation | Maximum Switching Current @ Voltage | Reset Type | Input Voltage | Environmental Rating | Each | |
For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout | ||||||||||
32° to 390° F 0° to 200° C | J | 1 | Heating—One Mechanical Relay | SPDT | 8 A @ 30 V DC 8 A @ 240 V AC | Automatic | 120V AC | IP65, NEMA 4X | 000000 | 0000000 |
32° to 2,190° F 0° to 1,200° C | K | 1 | Heating—One Mechanical Relay | SPDT | 8 A @ 30 V DC 8 A @ 240 V AC | Automatic | 120V AC | IP65, NEMA 4X | 000000 | 000000 |
Mechanical Relay | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Temperature Control Range | For RTD Probe Type | Total No. of Outputs | Output Type | Industry Designation | Maximum Switching Current @ Voltage | Reset Type | Input Voltage | Environmental Rating | Each | |
For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout | ||||||||||
32° to 1,470° F 0° to 800° C | 100 ohms | 1 | Heating—One Mechanical Relay | SPDT | 8 A @ 30 V DC 8 A @ 240 V AC | Automatic | 120V AC | IP65, NEMA 4X | 000000 | 0000000 |
Autotuning Temperature Controllers
Ideal in systems with rapid, unpredictable, or complex temperature changes, these controllers turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. They work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. You can also manually select the PID variables. These controllers read temperature with a highly sensitive thermocouple or RTD probe (both not included) in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. All fit into instrument panels with DIN cutouts. Use the keypad to adjust the actuation point, reset point, other settings.
All meet American, Canadian, and European safety standards.
Mechanical relay outputs actuate circuits directly. All are single pole, single throw (SPST) relays and turn one circuit from off to on (normally open). Solid state relay drive outputs send a pulse signal to directly control an external solid state relay (not included). They have a longer service life than mechanical and signal relays. Use them for more precise and rapid control switching than mechanical relays. Analog signal outputs are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
Alarm outputs can also be configured to actuate simple devices.
IP20 rated controllers prevent objects about the size of a finger from coming into contact with a live circuit. IP50 rated controllers protect against dust.
DIN-rail/surface-mount adapters (sold separately) mount 1/16 DIN controllers to a DIN rail or surface.
DIN cutout adapters (sold separately) convert larger cutouts to fit 1/16 DIN controllers.
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/32 DIN–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
3 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 0000000 |
1/16 DIN–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
2 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
3 | Heating/Cooling—One Mechanical Relay Alarm—Two Mechanical Relays | SPST-NO | 5 A @ 110 V AC | RTD, Thermocouple | Automatic | 90V AC to 264V AC | __ | 00000000 | 000000 |
1/8 DIN–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout | |||||||||
3 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/8 DIN–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
3 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
3/16 DIN–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout | |||||||||
3 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/4 DIN–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout | |||||||||
3 | Heating—One Mechanical Relay Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
4 | Heating/Cooling—Two Mechanical Relays Alarm—Two Mechanical Relays | SPST-NO | 5 A @ 110 V AC | RTD, Thermocouple | Automatic | 90V AC to 264V AC | __ | 00000000 | 000000 |
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/32 DIN–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
3 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 0000000 |
1/16 DIN–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
2 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
3 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/8 DIN–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout | |||||||||
3 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/8 DIN–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
3 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
3/16 DIN–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout | |||||||||
3 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/4 DIN–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout | |||||||||
3 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
4 | Heating—One 14V DC Solid State Relay Drive Cooling/Alarm—One Mechanical Relay Alarm—Two Mechanical Relays | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
Mechanical Relay | |||||||||
---|---|---|---|---|---|---|---|---|---|
Total No. of Outputs | Output Type | Industry Designation | Max. Switching Current @ Voltage | For Probe Type | Reset Type | Input Voltage Range | Environmental Rating | Each | |
1/32 DIN–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
3 | Heating—One 4-20 mA Analog Signal Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 0000000 |
1/16 DIN–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
2 | Heating—One 4-20 mA Analog Signal Cooling/Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/8 DIN–For 1 3/4" Ht. × 3 5/8" Wd. Panel Cutout | |||||||||
3 | Heating—One 4-20 mA Analog Signal Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/8 DIN–For 3 5/8" Ht. × 1 3/4" Wd. Panel Cutout | |||||||||
3 | Heating—One 4-20 mA Analog Signal Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
3/16 DIN–For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout | |||||||||
3 | Heating—One 4-20 mA Analog Signal Cooling/Alarm—One Mechanical Relay Alarm—One Mechanical Relay | SPST-NO | 2 A @ 240 V AC | RTD, Thermocouple | Automatic | 90V AC to 250V AC | IP20, IP50 | 00000000 | 000000 |
1/4 DIN–For 3 5/8" Ht. × 3 5/8" Wd. Panel Cutout | |||||||||
3 | Heating/Cooling—One 4-20 mA Analog Signal Alarm—Two Mechanical Relays | SPST-NO | 5 A @ 110 V AC | RTD, Thermocouple | Automatic | 90V AC to 264V AC | __ | 00000000 | 000000 |
Mounting | ||||
---|---|---|---|---|
Fasteners Included | Screw Size | No. of Holes | Each | |
No | No. 6 | 2 | 000000000 | 000000 |