McMaster-Carr logo
    Filter by
    System of Measurement
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Output Data Frequency
    Maximum Pressure
    Connection Location
    Control Communication Protocol
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Industrial Info Compare
    Thread Type
    Industrial Info Compare
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    126 Products

    Environmental-Monitoring Modules for Development Boards

    Keep equipment running and working conditions safe—these modules add air quality tracker capabilities to your development board. Each module gathers data on air conditions, ranging from temperature and humidity to carbon dioxide or volatile organic compound (VOC) levels. These modules easily connect to boards and other components with Qwiic cords or by soldering.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Modules with Temperature, Humidity, and Air Quality Sensor
    Image of Product. Front orientation. -10° C to 60° C. Environmental-Monitoring Modules for Development Boards .
    Modules with a temperature, humidity, and air quality sensor help you make sure the air is healthy in your facility. They directly measure the amount of carbon dioxide in the air.
    Output Data
    Resolution,
    bit
    Freq.,
    Hz
    Measures
    Temp. Range,
    ° C
    RH
    Carbon Dioxide Concentration
    Measured, ppm
    Input Voltage,
    V DC
    I2C
    Address
    Connection
    Method
    No. of Qwiic
    Connections
    Lg.
    Wd.
    Each
    I²C Communication Protocol—Qwiic Connection
    160.2Temperature, Relative Humidity, Carbon Dioxide Level-10 to 600% to 100%0 to 40,0002.4 to 5.50x62Solder21"1"7126N11000000
     
    Modules with Temperature, Humidity, and Barometer Sensor
    Image of Product. Front orientation. -40° C to 85° C. Environmental-Monitoring Modules for Development Boards .
    Modules with a temperature, humidity, and barometer sensor are often used as part of an automated system that runs equipment based on the weather. For instance, you can use them in a system that will turn on a humidifier if humidity dips below a certain level.
    Measures
    Temp. Range,
    ° C
    RH
    Barometric Pressure,
    in. Hg
    Input Voltage,
    V DC
    I2C
    Address
    Connection
    Method
    No. of Qwiic
    Connections
    Lg.
    Wd.
    Each
    I²C Communication Protocol—Qwiic Connection
    Temperature, Relative Humidity, Barometric Pressure-40 to 850% to 100%8.9 to 32.51.71 to 3.60x76
    0x77
    Solder21"1"7126N12000000
     
    Modules with Temperature, Humidity, Air Quality, and Barometer Sensor
    Image of Product. Front orientation. Development Board Sensor Modules. Environmental-Monitoring Modules for Development Boards , Air Quality Sensor.
    Modules with a temperature, humidity, air quality, and barometer sensor give you the most comprehensive picture of air conditions in your facility. They directly measure the amount of VOCs and give you an estimated measurement of carbon dioxide based on VOC levels. They monitor air quality using Germany’s Air Quality Index (AQI).
    Measures
    Temp. Range,
    ° C
    RH
    Equiv. Carbon Dioxide
    Concentration Measured, ppm
    Total Volatile
    Organic Compound, ppb
    Barometric Pressure,
    in. Hg
    Input Voltage,
    V DC
    I2C Address
    Connection
    Method
    No. of Qwiic
    Connections
    Lg.
    Wd.
    Each
    I²C Communication Protocol—Qwiic Connection
    Temperature, Relative Humidity, Equivalent Carbon Dioxide, Total Volatile Organic Compound Concentration, Air Quality Index, Barometric Pressure0 to 6520% to 80%400 to 650,0000 to 65,0008.9 to 32.51.2 to 3.60x52
    0x53
    0x76
    0x77
    Solder21"1"7126N14000000
     

    Wireless Thermocouple Transmitters for Liquids and Gases

    Monitor your system’s temperatures directly from your smart device. These battery-powered transmitters send real-time measurements to smartphones and tablets via Bluetooth, so you can easily confirm your processes are functioning properly. Good for route-based monitoring and preventative maintenance, they record measurements on your smart device and send alerts if equipment requires your attention. Use them to maintain a safe distance from your process or to stay out of a dirty environment. Install the app to set your parameters, choose how often you’d like to receive data, and monitor temperatures from up to 300 ft. away. Rated IP65, they’re protected against dust and washdowns.
    Turn your transmitter into a portable monitoring system by adding a quick coupling (not included). This lets you make fast, temporary connections to various equipment in different locations.
    Threaded Mount—17-4 PH Stainless Steel Probe
    Image of ProductInUse. Front orientation. Thermocouples. Wireless Thermocouple Transmitters for Liquids and Gases , Threaded Mount.
    Threaded-mount transmitters have probes to measure temperatures within pipes and tanks, producing more accurate readings than strap-mount transmitters.
    Probe
    Probe Connection
    Temp. Range,
    ° F
    Lg.
    Dia.
    Accuracy
    Response
    Time, sec.
    Pipe
    Size
    Thread
    Size
    Thread
    Type
    Gender
    Wireless
    Range, ft.
    Ht.
    Wd.
    Batteries
    Included
    Enclosure
    Rating
    Mfr. (Series)
    Each
    Bluetooth Connection
    -40 to 23013/32"1/4"±3%17/16"-20
    UNF
    Male3002 3/4"1 7/8"YesIP65
    Parker (Sensonode Blue)7128N110000000
    -40 to 23013/32"1/4"±3%11/4
    NPT
    Male3002 11/16"1 7/8"YesIP65
    Parker (Sensonode Blue)7128N12000000
    -40 to 2303 3/8"1/4"±3%17/16"-20
    UNF
    Male3002 3/4"1 7/8"YesIP65
    Parker (Sensonode Blue)7128N13000000
    -40 to 2303 3/8"1/4"±3%11/4
    NPT
    Male3002 11/16"1 7/8"YesIP65
    Parker (Sensonode Blue)7128N14000000
     
    Strap Mount
    Image of ProductInUse. Front orientation. Thermocouples. Wireless Thermocouple Transmitters for Liquids and Gases , Strap Mount.
    Strap-mount transmitters can be installed almost anywhere with the included cable tie, so they’re good for equipment that might not have a threaded port available. However, because they mount externally, they are less accurate than threaded-mount transmitters.
    Temp. Range,
    ° F
    Accuracy
    Response
    Time, sec.
    Wireless
    Range, ft.
    Ht.
    Wd.
    Batteries
    Included
    Enclosure
    Rating
    Mfr. (Series)
    Each
    Bluetooth Connection
    -40 to 257±5%13002 5/16"2 7/16"YesIP65
    Parker (Sensonode Blue)7128N150000000
     

    Vibration Meters

    Image of System. Meter with Probe (Sold Separately). Front orientation. Vibration Meters. Vibration Meters.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. LCD Display. Vibration Meters.

    Meter with Probe (Sold

    Separately)

    LCD

    Display

    In addition to vibration, these meters measure acceleration, frequency, speed, displacement, and temperature. Use them to gauge the health of your bearings and machines. Onscreen analytics allow you to instantly check the condition of your equipment. These meters store up to 3,500 readings in memory, and you can transfer them to your computer with a USB cord (not included) to track trends.
    Cannot Be Sold To—Import regulations restrict sales to the listed areas.
    Measures
    Vibration Freq.
    Range, vpm
    Accel. Range,
    g
    Freq. Range,
    Hz
    Speed Range,
    in/sec
    Displacement
    Range, mil
    Temp. Range,
    ° F
    Accuracy
    Max. Reading
    Display Time, min.
    Probe
    Lg.
    Batteries
    Included
    Container
    Type
    Digital Display
    Type
    Cannot Be
    Sold To
    Each
    Vibration, Acceleration, Frequency, Displacement, Speed, Temperature600 to 60,0000.01 to 5010 to 1,0000.06 to 3071 to 4,8890 to 390±5%31/64"YesCaseLCDCanada8721T2000000000
    Accessories and Replacements for Vibration Meters

    Remote-Reading Temperature, Relative Humidity, and Dew Point Paper-Chart Data Recorders with Audio/Visual Alarm

    Image of Product. Front orientation. Data Recorders. Remote-Reading Temperature, Relative Humidity, and Dew Point Paper-Chart Data Recorders with Audio/Visual Alarm.
    Remotely record temperature, humidity, and dew point up to 10 feet from the display and set the alarm to sound and flash the display if temperature readings rise above or fall below a set range. This recorder has a remote probe on a 10-ft. cable and a display that can be set to show current temperature, minimum/maximum temperature, or relative humidity and calculated dew point.
    RH
    Dew
    Point
    For Chart
    Dia.
    For Recording
    Time
    Temp.
    Accuracy
    Range
    Accuracy
    Range
    Accuracy
    Voltage,
    V AC
    Ht.
    Wd.
    Dp.
    Batteries
    Included
    Fasteners
    Included
    Each
    8"24 hr., 7 day±1.8° F/±1° C0% to 95%±2%32° F to 120° F/0° C to 50° C±3.6° F/±2° C12010 1/8"9 3/8"2 3/4"YesNo38755K450000000
    Accessories and Replacements for Data Recorders

    Steam Pressure Gauges

    Designed for use with boilers, these gauges have a dual scale that displays pressure in psi and feet of H₂O and displays temperature in °F/°C.
    Painted Steel Case with Brass Connection—Dual Scale (Pounds per Square Inch, Feet of Water, Fahrenheit/Celsius Scale)
    Image of Product. Front orientation. Pressure Gauges. Steam Pressure Gauges, Dual Scale, Bottom Connection.
    Image of Product. Front orientation. Pressure Gauges. Steam Pressure Gauges, Dual Scale, Center-Back Connection.
    Image of Product. Bottom Connection. Front orientation. Contains Annotated. Steam Pressure Gauges, Bottom Connection.
    Image of Product. Center-Back Connection. Front orientation. Contains Annotated. Steam Pressure Gauges, Center-Back Connection.

    Bottom

    Connection

    Center-Back

    Connection

    Bottom

    Connection

    Center-Back

    Connection

    Temp. Range
    Bottom
    Connection
    Center-Back
    Connection
    Dial
    Dia.
    Pipe
    Size
    Case
    Color
    Display
    Environment,
    ° F
    Process,
    ° F
    For Use
    With
    Accuracy
    Stem
    Lg.
    Shoulder
    Lg.
    Choose a Pressure Range
    Each
    Each
    Any-Angle Mount
     
    NPT Male
    2 1/2"1/4
    Black70° F to 320° F/20° C to 160° C-40 to 14070 to 320Steam
    Water
    ±2% Full Scale (Grade B)1"0 to 75 psi/0 to 170 ft. H₂O———04013K25000000
    2 1/2"1/4
    Black70° F to 320° F/20° C to 160° C-40 to 14070 to 320Steam
    Water
    ±2% Full Scale (Grade B)1"2"0 to 75 psi/0 to 170 ft. H₂O———04013K2600000
    2 1/2"1/4
    Black70° F to 320° F/20° C to 160° C-40 to 14070 to 320Steam
    Water
    ±2% Full Scale (Grade B)1 1/2"2"0 to 75 psi/0 to 170 ft. H₂O———04013K2700000
    3 1/4"1/2
    Black70° F to 320° F/20° C to 160° C-40 to 14070 to 320Steam
    Water
    ±2% Full Scale (Grade B)2"0 to 100 psi/0 to 230 ft. H₂O, 0 to 200 psi/0 to 460 ft. H₂O4013K610000004013K6200000
     

    Temperature and Humidity Transmitters

    Image of Product. Front orientation. Temperature and Humidity Transmitters. Temperature and Humidity Transmitters.
    Image of Specification. A-Code, 4-Pole Male. Front orientation. Temperature and Humidity Transmitters. Temperature and Humidity Transmitters.

    A-Code,

    4-Pole

    Male

    These sensors measure temperature and humidity, then send that information to your PLC or controller to regulate heating and cooling equipment, alarms, and data recorders. Choose a sensor that works with your digital IO-Link or analog 4-20 mA system. Clip it to a DIN rail or mount it to a surface, and use the micro M12 plug to connect the sensor to your controller. These sensors are often installed in enclosures.
    Sensors meet American, Canadian, and European safety standards. Rated IP20, they’re designed so fingers can’t reach the electrical parts inside and get shocked. They also meet UL 94 V-0, so if they catch fire, they’ll self-extinguish within 10 seconds and won’t spread the fire by dripping.
    Temperature
    Relative
    Humidity
    Range
    Tolerance
    Range
    Tolerance
    Control Communication
    Protocol
    Output Analog
    Signal
    Voltage,
    V DC
    Ht.
    Wd.
    Dp.
    Electrical
    Connection
    For DIN
    Rail Ht., mm
    Mounting Fasteners
    Included
    Enclosure
    Rating
    Certification
    Each
    -40° F to 140° F
    -40° C to 60° C
    -1.8° F to 1.8° F
    -1° C to 1° C
    0% to 100%-4% to 4%4 mA to 20 mA245 1/2"1 1/2"1 1/2"M1235NoIP20
    CE Marked, UL Recognized Component, VDE Certified, C-UL Recognized Component
    7106N110000000
    -40° F to 175° F
    -40° C to 80° C
    -0.54° F to 0.54° F
    -0.3° C to 0.3° C
    0% to 100%-3% to 3%IO-Link245 1/2"1 1/2"1 1/2"M1235NoIP20
    CE Marked, UL Recognized Component, VDE Certified, C-UL Recognized Component
    7106N12000000
     

    Remote-Reading Temperature and Pressure Data Recorders

    Image of Product. Front orientation. Data Recorders. Remote-Reading Temperature and Pressure Data Recorders.
    Monitor temperature and pressure in hard-to-access system components with this data recorder that has remote sensors that track and store readings for upload to a PC.
    Recording
    Interval
    Batteries
    Pressure
    Range, psi
    Accuracy
    Min.,
    sec.
    Max.,
    hr.
    Temp. Range
    Temp.
    Accuracy
    Ht.
    Wd.
    Dp.
    Size
    No.
    Required
    Included
    Each
    Plastic Housing
    0 to 500±3 psi118-40° F to 150° F/-40° C to 65° C±1° F/±0.5° C2 1/2"3"1 3/32"9V1No3440K440000000
     
    Software

    Flow, Pressure, and Temperature Transmitters for Gases

    Image of Product. Front orientation. Flow Transmitters. Flow, Pressure, and Temperature Transmitters for Gases.
    Measure and transmit flow rate, pressure, and temperature of industrial gases, such as air, argon, CO2, and nitrogen, flowing through your system. These transmitters are ideal for applications where temperature and pressure can fluctuate. To calculate flow rate, they generate a small amount of heat, then measure the cooling effect your gas has on it. Also known as transducers, these transmitters convert measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs). As flow, temperature, and pressure increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them directly inline with your system. They measure correctly no matter their mounting orientation.
    A digital display makes it easy to read measurements and adjust settings based on your gas. These transmitters have two configurable outputs, and each output can only be wired for one measurement (flow rate, pressure, or temperature). Outputs configured as digital pulse send flow data using spikes of voltage that match the input voltage of the transmitter. One of the outputs can be wired for IO-Link, so you can change settings and receive error messages remotely from your PLC or computer. You’ll need an IO Link controller (not included) to connect to your interface.
    These transmitters are calibrated with air but still measure accurately when used with other gases.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    scfm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch/Pulse Output—4-Pole M12 Connection Plug
     
    304 Stainless Steel Body with 304 Stainless Steel Fitting
    Thermal1/2 NPT Male0.15 to 4411 13/16"±6%230 psi @ 70° F14 to 140Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4384N11000000000
    Thermal1 NPT Male0.4 to 13218 3/4"±6%230 psi @ 70° F14 to 140Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4384N1200000000
     

    Wi-Fi Enabled Water Detectors

    Image of Product. Detector. Top orientation. Water Detectors. Wi-Fi Enabled Water Detectors.
    Image of Product. Detector (Bottom). Bottom orientation. Contains Annotated. Water Detectors. Wi-Fi Enabled Water Detectors.

    Detector

    Detector (Bottom)

    Keep an eye on leaks, overflow, and temperature changes near your equipment, even when you’re offsite. These detectors connect to your Wi-Fi to send alerts about moisture, temperature, and humidity to your smartphone or tablet. Place them near tanks and tubs to watch for overflow, or near sump pumps and pipe lines to monitor temperatures and prevent frozen pipes. When water touches one of the sensors on the detector, a buzzer also goes off, alerting anyone nearby. Rated IP44, these detectors are protected from objects larger than 1mm, such as wires, and from water splashing in any direction.
    Download an app onto your smart device to program temperature and humidity ranges and set up alerts. You can also create reports that show changes in temperature and humidity over time.
    To extend the area they monitor, these detectors come with a detachable cable sensor that senses moisture along its entire surface. Swap in replacement cable sensors for worn sensors, or link several together to wrap around large equipment or trace the path of a pipe. Extend them up to 500 feet from detectors.
    Volume (Sound)
    @ Distance
    Sound
    Pattern
    Wd.
    Ht.
    Dp.
    Cord Lg.,
    ft.
    Material
    Batteries
    Included
    Sensor
    Location
    Operating System Compatibility
    Includes
    Each
    100 dBA @ 1 ft.Continuous3"2"1 1/16"5PlasticYesBottomAndroid 9.0 or Later, iOS 14.0 or LaterDetachable Cable Sensor, Mounting Screws6840N14000000
    Replacement Sensors

    Flow and Temperature Transmitters

    Image of Product. Back orientation. Flow Transmitters. Flow and Temperature Transmitters, Variable Area Flow Measurement.

    Variable Area Flow

    Measurement

    Image of Product. Back orientation. Flow Transmitters. Flow and Temperature Transmitters, Vortex Flow Measurement.

    Vortex Flow

    Measurement

    Send flow rate and temperature measurements simultaneously to a programmable logic controller (PLC), data logger, or other receiving device. Used to monitor status or control equipment, these transmitters, also known as transducers, convert measurements to an electrical signal that is interpreted by receiving devices. As flow or temperature increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them inline with your pipe system. They’ll measure flow correctly in any mounting orientation.
    A digital display makes it easy to view readings and adjust settings at the source. To change settings and receive error messages remotely from your PLC or computer, program one of the outputs to use IO Link. You’ll need an IO Link controller (not included) to connect to your interface.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Variable Area Flow Measurement—Variable-area transmitters determine the flow rate by tracking where the liquid pushes the piston. They have two configurable outputs. One can be wired as an analog output or a digital switch. The other one can be wired as a digital switch, digital pulse output, or IO Link. Pulse outputs send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send. These transmitters are calibrated with water, glycol solutions, and coolants but can be recalibrated in the field for other liquids.
    Vortex Flow Measurement—Vortex transmitters determine the flow rate by measuring the size of the vortex created as liquid flows through them. They don’t have any moving parts that can break or get stuck. Use them only with liquids that are at least 95% water. They have one analog output for flow and another for temperature. The output for temperature can also be wired for IO Link.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gph
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch/Pulse Output—4-Pole M12 Connection Plug
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Variable Area3/4 NPT Female5 to 2405 9/16"±5%580 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N110000000
    Variable Area3/4 NPT Female7 to 3605 9/16"±5%580 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N12000000
    Variable Area3/4 NPT Female10 to 6005 9/16"±5%580 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N13000000
    Variable Area1 NPT Female30 to 1,6205 3/4"±5%362 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N14000000
    Variable Area1 1/2 NPT Female60 to 3,0006 3/16"±5%362 psi @ 70° F14 to 212Fluoroelastomer
    18 to 30Any AngleYesIP65, IP67
    4401N15000000
     
    Two 4-20 mA Analog Transmitter Outputs—4-Pole M12 Connection Plugs
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Vortex1/2 NPT Female16 to 3174 11/16"±2%172 psi @ 70° F14 to 190Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4401N16000000
    Vortex1/2 NPT Female32 to 6344 11/16"±2%172 psi @ 70° F14 to 190Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4401N17000000
    Vortex3/4 NPT Female80 to 1,5855 15/32"±2%172 psi @ 70° F14 to 190Fluoroelastomer
    18 to 30Any AngleNoIP65, IP67
    4401N18000000
     

    Wireless Temperature and Humidity Transmitters

    Image of ProductInUse. Front orientation. Temperature and Humidity Transmitters. Wireless Temperature and Humidity Transmitters.
    Use smartphones and tablets to monitor humidity and temperature within your system or facility. Connect these battery-powered transmitters to your smart device via Bluetooth, and receive data to ensure workplace conditions are suitable for processes, inventory, or personnel. Good for preventative maintenance and route-based monitoring, these transmitters let you choose how frequently you receive the data, and they’ll notify your device when humidity and temperature levels go outside of your thresholds. Download the app, set your parameters, and collect data from up to 300 ft. away. Rated IP65, they are protected against dust and washdowns.
    Turn your transmitter into a portable monitoring system by attaching a quick coupling (not included). This allows fast, temporary connections for on-the-go measurements in different locations.
    Temperature
    Relative
    Humidity
    Connection
    Type
    Range,
    ° F
    Accuracy
    Range
    Accuracy
    Response
    Time, sec.
    Pipe
    Size
    Thread
    Type
    Gender
    Wireless
    Range, ft.
    Ht.
    Wd.
    Batteries
    Included
    Enclosure
    Rating
    Manufacture (Series)
    Each
    Bluetooth Connection
    14 to 185±1° F0% to 100%±5%101/4
    NPT
    Male3002 11/16"1 7/8"YesIP65
    Parker (Sensonode Blue)7129N110000000
     

    Fluke Test Lead Sensors

    Image of Product. Front orientation. Test Lead Sensors. Fluke Test Lead Sensors, Model Number 80BK-A.
    Image of Product. Front orientation. Test Lead Sensors. Fluke Test Lead Sensors, Model Number 80TK.

    Model Number 80BK-A

    Model Number 80TK

    Take temperature readings with a Fluke multimeter.
    Model Number 80BK-A—Fluke 80BK-A is a temperature probe and works with Fluke multimeters that measure temperature. It has 4 mm standard banana jack connection ends that attach to Fluke test leads that have 4 mm banana plugs.
    Model Number 80TK—Fluke 80TK is a thermocouple converter that adapts a Fluke multimeter without a temperature function to a thermometer using the included temperature probe. It has 4 mm standard banana plug connection ends that attach to 4 mm banana jacks on Fluke multimeters.
    Mfr. Model
    No.
    For Fluke Model No.
    Temp. Range,
    ° F
    AC Voltage,
    V AC
    DC Voltage,
    V DC
    Test End
    Component
    Connection End
    Cord
    Lg.
    Test End Insulation
    Material
    Each
    80BK-A28 II, 87V, 116, 179, 233, 287, 289-40 to 500Needle TipSheathed Standard Banana Jack39"PTFE
    7093K13000000
    80TK27 II, 28 II, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 789-40 to 5002460Needle TipSheathed Standard Banana Plug39"PTFE
    7093K51000000

    Airflow/Temperature Meters

    These versatile meters display airflow and one other measurement simultaneously. They’re also known as anemometers or vane meters. They can show airflow measurements on multiple scales, such as fpm, mph, and knots.
    Fan
    Image of Product. Front orientation. Airflow Meters. Airflow/Temperature Meters, Fan.
    4" Diameter Blade—Meters with a 4” blade diameter give you more accurate readings on large HVAC ducts than meters with smaller blades.
    Overall
    Airflow Speed
    RH
    Temperature
    Range
    Dew Point
    Range, ° F
    Display
    Type
    Ht.
    Wd.
    Dp.
    Blade
    Dia.
    Batteries
    Included
    Includes
    Each
    Measures Airflow and Temperature
    40 to 5,900 fpm
    0.2 to 30 m/s
    0° to 140° F
    -20° to 60° C
    Digital10 1/2"4 1/4"2"4"YesCarrying Case1410K1020000000
     
    Measures Airflow, Temperature, Relative Humidity, and Dew Point
    40 to 5,900 fpm
    0.2 to 30 m/s
    1% to 99%0° to 140° F
    -20° to 60° C
    32 to 122Digital10 1/2"4 1/4"2"4"YesCarrying Case1410K103000000
     
    Fan—Foldable
    Image of Product. Front orientation. Airflow Meters. Airflow/Temperature Meters, Fan—Foldable.
    Foldable fan meters are small enough to fit in your pocket when closed, then extend to 9” when unfolded.
    Airflow Meters
    Replacement
    Batteries
    Overall
    Airflow Speed
    RH
    Temperature
    Range
    Dew Point
    Range, ° F
    Display
    Type
    Ht.
    Wd.
    Dp.
    Blade
    Dia.
    Batteries
    Included
    Includes
    Each
    Pkg.
    Qty.
    Pkg.
    Measures Airflow and Temperature
    100 to 5,500 fpm
    1.1 to 60 mph
    1 to 50 kn
    0.5 to 20 m/s
    1.8 to 100 kph
    0° to 122° F
    -18° to 50° C
    Digital5 1/4" to 9"2 3/4"3/4"1"YesLanyard1410K14000000017701K3400000
     
    Measures Airflow, Temperature, Relative Humidity, and Dew Point
    100 to 5,500 fpm
    1.1 to 60 mph
    1 to 50 kn
    0.5 to 20 m/s
    1.8 to 100 kph
    10% to 95%0° to 122° F
    -18° to 50° C
    32 to 122Digital5 1/4" to 9"2 3/4"3/4"1"YesLanyard1410K1500000017701K340000
     
    Fan—Compass, Foldable
    Image of Product. Front orientation. Airflow Meters. Airflow/Temperature Meters, Fan Meter, Foldable.
    Foldable fan meters are small enough to fit in your pocket when closed, then extend to 9” when unfolded.
    Airflow Meters
    Replacement
    Batteries
    Overall
    Airflow Speed
    RH
    Temperature
    Range
    Dew Point
    Range, ° F
    Display
    Type
    Ht.
    Wd.
    Dp.
    Blade
    Dia.
    Batteries
    Included
    Includes
    Each
    Pkg.
    Qty.
    Pkg.
    Measures Airflow, Temperature, Relative Humidity, and Dew Point
    60 to 3,900 fpm
    0.5 to 40 mph
    0.4 to 30 kn
    1.1 to 20 m/s
    0.8 to 70 kph
    1% to 99%5° to 120° F
    -15° to 50° C
    -4 to 122Digital5 1/2" to 9"1 3/4"1"1"YesLanyard1410K101000000017701K3400000
     

    Remote-Reading Airflow/Temperature Meters

    With a probe on a cord, these meters access hard-to-reach places in duct. They display airflow and temperature simultaneously and can show airflow measurements on multiple scales, such as fpm, mph, and knots. Also known as anemometers.
    Fan
    Image of Product. Front orientation. Airflow Meters. Remote-Reading Airflow/Temperature Meters, Fan.
    Fan meters are also known as vane meters. Those with a built-in surface temperature thermometer also measure the temperature of hard-to-reach surfaces.
    3.5 mm Audio Connection—Meters with a 3.5 mm audio data connection can transmit data through a USB connection using a USB adapter cord (sold separately, except for Style C).
    Standard SD Card Connection—Meters with an SD card data connection store timestamped readings on an SD card in Excel format, for easy datalogging and PC transfer.
    Overall
    Airflow Speed
    Temperature
    Range
    Display
    Type
    Max. Air Volume,
    ft³/min
    Ht.
    Wd.
    Dp.
    Probe Cable
    Lg., ft.
    Data Connection
    Batteries
    Included
    Includes
    Each
    Measures Airflow and Temperature
    60 to 6,900 fpm
    0.7 to 78.2 mph
    0.6 to 68 kn
    0.4 to 35 m/s
    1 to 126 kph
    32° to 158° F
    0° to 70° C
    Digital7 3/16"2 7/8"1 7/8"3Standard SD CardYesCarrying Case4120K1040000000
     
    Measures Airflow, Temperature, and Air Volume
    80 to 5,906 fpm
    0.9 to 67.2 mph
    0.8 to 58.3 kn
    0.4 to 30 m/s
    1.4 to 108 kph
    14° to 140° F
    -10° to 60° C
    Digital9,9997"2 7/8"1 5/16"4YesCarrying Case4120K102000000
    100 to 6,800 fpm
    1.14 to 70 mph
    1 to 60 kn
    0.5 to 30 m/s
    1.83 to 125 kph
    32° to 175° F
    0° to 80° C
    Digital999,9007"2 15/16"1 5/16"33.5 mm AudioYesCarrying Case4120K35000000
     
    Measures Airflow, Temperature, and Air Volume, —With Calibration Certificate Traceable to NIST
    80 to 5,906 fpm
    0.9 to 67.2 mph
    0.8 to 58.3 kn
    0.4 to 30 m/s
    1.4 to 108 kph
    14° to 140° F
    -10° to 60° C
    Digital9,9997"2 7/8"1 5/16"4YesCarrying Case4120K109000000
     
    Fan—Built-In Surface Temperature Thermometer
    Image of Product. Front orientation. Contains Annotated. Airflow Meters. Remote-Reading Airflow/Temperature Meters, Fan—Built-In Surface Temperature Thermometer.
    Fan meters are also known as vane meters. Those with a built-in surface temperature thermometer also measure the temperature of hard-to-reach surfaces.
    Overall
    Airflow Speed
    Temperature
    Range
    Display
    Type
    Max. Air Volume,
    ft³/min
    Ht.
    Wd.
    Dp.
    Probe Cable
    Lg., ft.
    Batteries
    Included
    Includes
    Each
    Measures Airflow, Temperature, and Air Volume
    80 to 5,906 fpm
    0.9 to 67.2 mph
    0.8 to 58.3 kn
    0.4 to 30 m/s
    1.4 to 108 kph
    14° to 140° F
    -10° to 60° C
    Digital999,9997"2 7/8"1 5/16"4YesCarrying Case4120K1030000000
     
    Mini Fan—Fan in Probe Tip
    Image of Product. Front orientation. Airflow Meters. Remote-Reading Airflow/Temperature Meters, Mini Fan—Fan in Probe Tip.
    Mini fan meters have a fan at the end of a telescoping probe. You can also use them to measure humidity.
    3.5 mm Audio Connection—Meters with a 3.5 mm audio data connection can transmit data through a USB connection using a USB adapter cord (sold separately, except for Style C).
    Overall
    Probe
    Airflow Speed
    RH
    Temperature
    Range
    Display
    Type
    Max. Air Volume,
    ft³/min
    Ht.
    Wd.
    Dp.
    Dia.
    Cable Lg.,
    ft.
    Max. Probe
    Extension, ft.
    Data
    Connection
    Batteries
    Included
    Includes
    Each
    Measures Airflow, Temperature, Relative Humidity, and Air Volume
    100 to 3,940 fpm
    0.5 to 20 m/s
    0% to 100%-4° to 140° F
    -20° to 60° C
    Digital99,9996 11/16"3"1 11/16"23/32"333.5 mm AudioYes3 ft. Long USB Adapter Cord, Carrying Case, Data-Recording Software4120K1050000000
     
    USB Cords
    Pitot Tube
    Image of Product. Front orientation. Airflow Meters. Remote-Reading Airflow/Temperature Meters, Pitot Tube.
    Pilot tube meters measure a wider airflow range than other meters. They also measure differential pressure.
    Mini USB-B Connection—Meters with a mini-USB and micro-USB connection type transmit data to your PC through the included cable.
    Overall
    Probe
    Airflow Speed
    Temperature
    Range
    Display
    Type
    Pressure Differential
    Range, psi
    Max. Air Volume,
    ft³/min
    Ht.
    Wd.
    Dp.
    Dia.
    Cable Lg.,
    ft.
    Data
    Connection
    Batteries
    Included
    Includes
    Each
    Measures Airflow, Temperature, Air Volume, and Differential Pressure
    200 to 15,733 fpm
    2.25 to 178.66 mph
    2 to 154.6 kn
    1 to 80 m/s
    3.5 to 288 kph
    32° to 122° F
    0° to 50° C
    Digital0 to 0.7399,9998 3/16"2 7/8"1 7/8"11/32"3Mini USB-BYes3 ft. Long USB Cord, Carrying Case, Data-Recording Software, Two 3 ft. Long Pitot Tubes4120K1070000000
     
    Telescoping Tube
    Image of Product. Front orientation. Airflow Meters. Remote-Reading Airflow/Temperature Meters, Telescoping Tube.
    Telescoping tube meters are also known as hot wire meters. They have a probe that telescopes to reach into narrow openings.
    3.5 mm Audio Connection—Meters with a 3.5 mm audio data connection can transmit data through a USB connection using a USB adapter cord (sold separately, except for Style C).
    Standard SD Card Connection—Meters with an SD card data connection store timestamped readings on an SD card in Excel format, for easy datalogging and PC transfer.
    Overall
    Probe
    Airflow Speed
    Temperature
    Range
    Display
    Type
    Max. Air Volume,
    ft³/min
    Ht.
    Wd.
    Dp.
    Dia.
    Cable Lg.,
    ft.
    Max. Probe
    Extension, ft.
    Data Connection
    Batteries
    Included
    Includes
    Each
    Measures Airflow and Temperature
    40 to 3,900 fpm
    0.5 to 40 mph
    1 to 30 kn
    0.2 to 20 m/s
    0.7 to 70 kph
    32° to 122° F
    0° to 50° C
    Digital7"2 15/16"1 5/16"1/2"433.5 mm AudioYes4120K540000000
     
    Measures Airflow and Temperature—With Calibration Certificate Traceable to NIST
    40 to 3,900 fpm
    0.5 to 40 mph
    1 to 30 kn
    0.2 to 20 m/s
    0.7 to 70 kph
    32° to 122° F
    0° to 50° C
    Digital7"2 15/16"1 5/16"1/2"433.5 mm AudioYes4120K111000000
     
    Measures Airflow, Temperature, and Air Volume
    40 to 3,300 fpm
    0.5 to 30 mph
    0.39 to 30 kn
    0.2 to 10 m/s
    0.7 to 60 kph
    32° to 122° F
    0° to 50° C
    Digital1,270,0008"3"1 1/2"1/2"433.5 mm AudioYes4120K37000000
    40 to 3,940fpm
    0.5 to 45 mph
    1 to 31 kn
    0.2 to 25 m/s
    0.7 to 72 kph
    32° to 122° F
    0° to 50° C
    Digital1,907,0007 3/16"2 7/8"1 7/8"1/2"43Standard SD CardYesCarrying Case4120K106000000
     
    USB Cords
    Telescoping Tube—Gooseneck
    Image of Product. Front orientation. Airflow Meters. Remote-Reading Airflow/Temperature Meters, Telescoping Tube—Gooseneck.
    Telescoping tube meters are also known as hot wire meters. They have a probe that telescopes to reach into narrow openings.
    Micro USB-B Connection—Meters with a mini-USB and micro-USB connection type transmit data to your PC through the included cable.
    Overall
    Probe
    Airflow Speed
    Temperature
    Range
    Display
    Type
    Max. Air Volume,
    ft³/min
    Ht.
    Wd.
    Dp.
    Dia.
    Cable Lg.,
    ft.
    Max. Probe
    Extension, ft.
    Data
    Connection
    Batteries
    Included
    Includes
    Each
    Measures Airflow, Temperature, and Air Volume
    60 to 5,904 fpm
    0.7 to 67 mph
    0.6 to 58.3 kn
    0.3 to 30 m/s
    1 to 108 kph
    32° to 113° F
    0° to 45° C
    Digital999,9007 5/8"2 11/16"1 5/16"1/16"5.52 1/2Micro USB-BYes3 ft. Long USB Cord, Carrying Case, Data-Recording Software4120K1010000000
     

    High-Accuracy Flow and Temperature Transmitters

    Image of Product. Back orientation. Flow Transmitters. High-Accuracy Flow and Temperature Transmitters.
    Also known as magmeters, these transmitters use a magnetic field to measure flow rate and temperature with high accuracy. Because they use a magnetic field, they only work with conductive liquids, such as water. These transmitters, also known as transducers, convert measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs) to monitor flow or control equipment. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. As flow or temperature increases, the output signal increases. These transmitters have one analog output for flow and another for temperature. They only give accurate readings within the rated measurement range. A digital display makes it easy to view readings and adjust settings at the source. Mount these transmitters inline with your pipe system. They measure flow correctly in any mounting orientation.
    These transmitters are calibrated with water. They can only be used with liquids with a conductivity of at least 20 µS/cm.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Flow Range
    Flow Measurement
    Type
    Pipe
    Connections
    Gallons per
    Minute, gpm
    Liters per
    Minute, L/min
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    Two 4-20 mA Analog Transmitter Outputs—4-Pole M12 Connection Plugs
     
    316 Stainless Steel/Plastic/Polybutylene Body with 316 Stainless Steel Fitting
    Magnetic Induction1/2 NPT Female0.03 to 6.60.1 to 252 1/8"±2%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP67
    4397N1010000000
    Magnetic Induction3/4 NPT Female0.02 to 13.220.2 to 502 1/8"±2%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP67
    4397N102000000
    Magnetic Induction1 NPT Female0.1 to 26.40.2 to 1002 1/8"±2%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP67
    4397N103000000
    Magnetic Induction1 1/2 NPT Female1.3 to 79.35 to 3006 11/16"±0.8%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP65, IP67
    4397N10400000000
    Magnetic Induction2 NPT Female1.3 to 158.55 to 6007 1/16"±0.8%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP65, IP67
    4397N10500000000
     

    Fluke Insulation-Testing Multimeters

    Image of Product. Front orientation. Multimeters. Fluke Insulation-Testing Multimeters.
    Check insulation quality in electrical equipment such as motors and power tools. You can also take other electrical measurements with these Fluke multimeters, known for quality and durability.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Multimeters
    Multimeters with
    Calibration Certificate
    Mfr. Model
    No.
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    mA
    Max. DC Current,
    mA
    Hardware Features
    Display
    Count
    Includes
    Enclosure
    Rating
    Each
    Each
    True RMS AC Calculation
    1587 FCCAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0000.09%400400Overload Protection6,000Alligator Clips, Hard Case, Remote Probe, Temperature Probe, Test LeadsIP40
    7093K6800000007093K901000000000
     

    Remote-Reading Temperature Paper-Chart Data Recorders with Audio/Visual Alarm

    Image of Product. Front orientation. Data Recorders. Remote-Reading Temperature Paper-Chart Data Recorders with Audio/Visual Alarm.
    To alert you of temperature fluctuations, these recorders sound an alarm and flash the display when temperature rises above or falls below the programmable temperature range. They have a thermocouple type-K probe on a 4-ft. cable for taking readings in hard-to-access areas.
    Note: Thermocouple probes are not interchangeable with RTD probes.
    For Chart
    Dia.
    For Recording
    Time
    Temp. Accuracy
    Voltage,
    V AC
    Ht.
    Wd.
    Dp.
    Batteries
    Included
    Fasteners
    Included
    Each
    8"24 hr., 7 day±3.8° F/±2.1° C12010 1/8"9 3/8"2 3/4"YesNo33185K110000000
    Accessories and Replacements for Data Recorders

    Temperature and Relative Humidity Paper-Chart Data Recorders

    Image of Product. Front orientation. Data Recorders. Temperature and Relative Humidity Paper-Chart Data Recorders.
    Track ambient temperature and relative humidity over time with this recorder. Recorders come with a replaceable sensor, so no probe is needed.
    Data Recorders with Calibration Certificate Traceable to NIST—Data recorders with a NIST certificate of calibration include a calibration certificate traceable to NIST that states the recorder has passed a test for accuracy.
    RH
    For Chart
    Dia.
    For Recording
    Time
    Temp.
    Accuracy
    Range
    Accuracy
    Ht.
    Wd.
    Dp.
    Temp. Features
    Batteries
    Included
    Fasteners
    Included
    Each
    Data Recorders with Calibration Certificate Traceable to NIST
    8"24 hr., 7 day±1.8° F/±1° C0% to 95%±2%10 1/8"9 3/8"2 3/4"Audible High/Low Alarm, Min./Max. Display, Visual High/Low AlarmYesNo39025K880000000
     
    Replacement Temperature Data Recorder Pens

    Insertion-Mount Flow and Temperature Transmitters

    Image of ProductInUse. Front orientation. Flow Transmitters. Insertion-Mount Flow and Temperature Transmitters.
    Image of Product. Top orientation. Flow Transmitters. Insertion-Mount Flow and Temperature Transmitters.
    Thread mounting hardware (sold separately) into your pipe connection and insert the probe of these transmitters to measure the flow and temperature of water, oil, or air. The probe is held in place with a compression fitting on the other end of the mounting hardware. They’re often used in large-diameter pipes where it would be difficult to install a transmitter inline. To calculate the flow rate, these transmitters generate a small amount of heat, then measure the cooling effect your liquid or air has on it. They measure and output both flow and temperature, making them ideal for applications where temperature fluctuates. Also known as transducers, they convert measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs) to monitor flow or control equipment. As flow or temperature increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. They’ll measure flow correctly in any mounting orientation. These transmitters are calibrated with air, glycol solutions, oil, and water but can be recalibrated in the field for other liquids.
    Adjust settings at the source using the digital display. These transmitters have two configurable outputs. One can be wired for flow or temperature as an analog output or a digital switch. The other one can be wired for flow as a digital switch, digital pulse output, or IO Link. Pulse outputs send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send. To change settings and receive error messages remotely from your PLC or computer, you can program one of the outputs to use IO Link. You’ll need an IO Link controller (not included) to connect to your interface.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Flow Measurement
    Type
    Flow Range,
    gpm
    Probe
    Lg.
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch/Pulse Output—4-Pole M12 Connection Plug
     
    316 Stainless Steel/Polybutylene Body with 316 Stainless Steel Fitting
    Thermal0.02 to 123 15/16"7 9/16"±10%725 psi @ 212° F0 to 21218 to 30Any AngleYesIP65, IP67
    4426N1010000000
    Thermal0.02 to 127 7/8"11 1/2"±10%725 psi @ 212° F0 to 21218 to 30Any AngleYesIP65, IP67
    4426N102000000
     
    Flow Transmitter Mounting Hardware

    Quick-Export Temperature and Relative Humidity Data Recorders

    Image of Product. Front orientation. Data Recorders. Quick-Export Temperature and Relative Humidity Data Recorders.
    No cords or software required—these data recorders store readings on an included SD card in Excel format for easy transfer to a PC.
    Data Recorders with Calibration Certificate Traceable to NIST—Data recorders with a NIST certificate of calibration include a calibration certificate traceable to NIST that states the recorder has passed a test for accuracy.
    RH
    Recording
    Interval, sec.
    Digital Display
    Type
    Digit
    Ht.
    Temp. Range
    Temp. Accuracy
    Range
    Accuracy
    Min.
    Max.
    Ht.
    Wd.
    Dp.
    Batteries
    Included
    Each
    Data Recorders
    LCD1/2"32° F to 122° F/0° C to 50° C±1.5° F/±0.8° C10% to 90%±4%56005 3/16"3 1/16"1 5/16"Yes1255N10000000
     
    Data Recorders with Calibration Certificate Traceable to NIST
    LCD1/2"32° F to 122° F/0° C to 50° C±1.5° F/±0.8° C10% to 90%±4%56005 3/16"3 1/16"1 5/16"Yes1255N2000000
     

    Indoor Environmental Meters

    Image of Product. Front orientation. Airflow Meters. Indoor Environmental Meters.
    Measure airflow, light, humidity, and temperature with a single, pocket-sized tool. These meters have built-in sensors that can detect multiple environmental factors in your plant or office. This helps you maintain safety compliance and track energy efficiency. A data hold function lets you freeze a measurement on the screen, giving you time to write it down. Additionally, they have the memory to store your high and low measurements. These meters are also known as hygro-thermo-anemometers.
    They’re CE marked as compliant with European health, safety, and environmental standards.
    Fan
    Light
    Measurement Range
    Overall
    Airflow Speed
    For Light
    Tech.
    Footcandles,
    fc
    Lux, lx
    RH
    Temperature
    Range
    Display
    Type
    Ht.
    Wd.
    Dp.
    Blade
    Dia.
    Batteries
    Included
    Certification
    Each
    Measures Airflow, Temperature, Light, and Relative Humidity
    80 to 5,905 fpm
    0.4 to 25 mm/s
    1.45 to 105 kph
    0.95 to 65 mph
    0.85 to 55 kn
    Halogen0 to 1,8550 to 15,00095%35° to 120° FLCD6"2 1/4"1 1/4"1"YesCE Marked
    7598N110000000
     
    Thermocouple Probes for Light Meters

    Handheld Machine-Monitoring Sensors

    Image of ProductInUse. Sensor Shown with App. Front orientation. Vibration Monitors. Handheld Machine-Monitoring Sensors.
    Image of ProductInUse. Measure Speed, Acceleration, and Temperature. Front orientation. Vibration Monitors. Handheld Machine-Monitoring Sensors.
    Image of Product. Sensor. Front orientation. Vibration Monitors. Handheld Machine-Monitoring Sensors.

    Sensor Shown with App

    Measure

    Speed,

    Acceleration,

    and

    Temperature

    Sensor

    Monitor the health of pumps, engines, and other rotating equipment from your wireless device. These battery-powered sensors measure speed, acceleration, and temperature to help identify potential problems related to balance, alignment, and lubrication. Good for daily maintenance checks, they're battery powered and magnetic, so you can stick them on a machine, take a reading, and move to the next machine. They send readings using Bluetooth, which you can review in the field or offsite.
    Install the app on your device and create profiles for multiple pieces of equipment—once created, you won’t have to enter information each time you want to do a maintenance check. Based on your machine profiles, the app will set default alarm thresholds. It will also recommend courses of action.
    For the Manufacturer User Manual, click on a part number and select Product Detail.
    Measures
    Freq. Range,
    Hz
    Speed Range,
    in/sec
    Enveloping
    Accel. Range, gE
    Operating System Compatibility
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Batteries
    Included
    Battery Charger
    Included
    Enclosure
    Rating
    Certification
    Each
    Acceleration, Speed, Temperature1 to 10,0000 to 2.170 to 20Android 11.0 or Later, iOS 16.0 or Later5 1/4"1 3/4"1 3/4"-5 to 140YesYesIP65
    CE Marked
    6161N114000000000
    Replacements for Vibration Monitors

    Compact Temperature Paper-Chart Data Recorders

    Image of Product. Front orientation. Data Recorders. Compact Temperature Paper-Chart Data Recorders.
    About half the size of standard temperature data recorders, these are often used to monitor temperature inside refrigerators, incubators, storage compartments, and other small spaces. They have a built-in sensor, so no probe is needed.
    For Chart
    Dia.
    Temp. Range,
    ° F
    For Recording
    Time, day
    Temp.
    Accuracy
    Ht.
    Wd.
    Dp.
    Batteries
    Included
    Mounting Hole
    Dia. (No. of)
    Fasteners
    Included
    Each
    4"-22 to 1227±2%5 3/16"5 3/16"2 3/8"Yes25/64" (2)No38395K430000000
    4"0 to 1007±2%5 3/16"5 3/16"2 3/8"Yes25/64" (2)No38395K42000000
    Data Recorder Charts

    Remote-Reading Temperature Paper-Chart Data Recorders

    Image of Product. Front orientation. Data Recorders. Remote-Reading Temperature Paper-Chart Data Recorders.
    Record temperature in hard-to-access areas. These recorders have a remote thermocouple type-J probe on a 15-ft. cable. They include 60 assorted charts with a variety of recording times and temperature ranges.
    Note: Thermocouple probes are not interchangeable with RTD probes.
    Batteries
    Measurement
    Unit
    For Chart
    Dia.
    For Recording Time
    Includes
    Voltage,
    V AC
    Ht.
    Wd.
    Dp.
    Certification
    Size
    No.
    Required
    Included
    Mounting Hole
    Dia. (No. of)
    Fasteners
    Included
    Each
    Fahrenheit6"6 hr., 24 hr., 7 day2 Black Pens, 60 6" Charts1209 1/4"7 1/4"2 3/4"CE Marked
    AA8No1/2" (2)No32635K310000000
    Celsius6"6 hr., 24 hr., 7 day2 Black Pens, 60 6" Charts1209 1/4"7 1/4"2 3/4"CE Marked
    AA8No1/2" (2)No32635K21000000
    Accessories and Replacements for Data Recorders
    back to top