Filter by
Probe Material
Maximum Temperature
Hazardous Location Rating
Certification
Electrical Connection
Pipe Size
Output Voltage
Minimum Temperature
Probe Type
Application
Temperature Setting
Switch Starting Position
Electrical Phase
Maximum Switching Current @ Voltage
Export Control Classification Number (ECCN)
DFARS Specialty Metals
Hazardous Location Protection Type
Hazardous Location Threaded Temperature Switches
Probe | SPDT | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, ° F | Temp. Accuracy | No. of Actuation Points | Actuation Tolerance | No. of Circuits Controlled | Max. Switching Current @ Voltage (Electrical Phase) | Dia. | Lg. | Max. Pressure, psi | Ht. | Wd. | Dp. | Enclosure Rating | Hazardous Location Rating | Certification | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Threaded Brass Probe—1/2 NPT Male | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Adjustable Actuation Point | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 0 to 225 | ±2° F | 1 | -1% to 1% | 1 | 15 amp @ 125V AC (Single) 15 amp @ 250V AC (Single) 15 amp @ 480V AC (Single) | 9/16" | 1 7/8" | 1,897 | 10" | 5 1/8" | 5 3/16" | IP66, NEMA 4X, NEMA 7, NEMA 9 | ATEX II 2 D Ex Tb IIIC T85° C Db ATEX II 2 G Ex Db IIC T6 Gb IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IECEx Ex D IIC T6 Gb IECEx Ex Tb IIIC T85° C Db NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA | UL Listed, C-UL Listed, CE Marked | 5032K67 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 0 to 225 | ±2° F | 2 | -1% to 1% | 2 | 15 amp @ 125V AC (Single) 15 amp @ 250V AC (Single) 15 amp @ 480V AC (Single) | 9/16" | 1 7/8" | 1,784 | 10" | 5 1/8" | 5 3/16" | IP66, NEMA 4X, NEMA 7, NEMA 9 | ATEX II 2 D Ex Tb IIIC T85° C Db ATEX II 2 G Ex Db IIC T6 Gb IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IECEx Ex D IIC T6 Gb IECEx Ex Tb IIIC T85° C Db NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA | UL Listed, C-UL Listed, CE Marked | 5032K87 | 00000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hazardous Location Wall-Mount Temperature Switches
Probe | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Temp. Accuracy | No. of Actuation Points | Max. Switching Current @ Voltage (Electrical Phase) | Dia. | Lg. | Ht. | Wd. | Dp. | Enclosure Rating | Hazardous Location Rating | Includes | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SPDT—1 Circuit Controlled | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Threaded Stainless Steel Probe—1/2 NPT Male | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 30° F to 250° F | ±5° F | 1 | 15 amp @ 125V AC (Single) 15 amp @ 250V AC (Single) 15 amp @ 480V AC (Single) | 3/8" | 2 5/8" | 9 5/16" | 5 1/8" | 5 3/16" | IP66, NEMA 4X, NEMA 7, NEMA 9 | ATEX II 2 D Ex Tb IIIC T85° C Db ATEX II 2 G Ex Db IIC T6 Gb IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IECEx Ex D IIC T6 Gb IECEx Ex Tb IIIC T85° C Db NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA | 1/2 × 3/4 NPT Adapter Bushing | 5032K66 | 000000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SPDT—2 Circuits Controlled | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Unthreaded Stainless Steel Probe | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 30° F to 250° F | ±5° F | 2 | 15 amp @ 125V AC (Single) 15 amp @ 250V AC (Single) 15 amp @ 480V AC (Single) | 3/8" | 2 5/8" | 9 5/16" | 5 1/8" | 5 3/16" | IP66, NEMA 4X, NEMA 7, NEMA 9 | ATEX II 2 D Ex Tb IIIC T85° C Db ATEX II 2 G Ex Db IIC T6 Gb IEC Zone 1 Groups IIC, IIB, IIA IEC Zone 21 Groups IIIC, IIIB, IIIA IECEx Ex D IIC T6 Gb IECEx Ex Tb IIIC T85° C Db NEC Class I Divisions 1, 2 Groups B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 1 Groups IIB, IIA | — | 5032K86 | 00000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Remote-Sensing Hazardous Location Line-Voltage Thermostats
Overall | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage, V AC | Current, amp | Temp. Setting, ° F | Switch Designation | Electrical Connection Type | Ht. | Wd. | Dp. | Sensor Cord Lg., ft. | For Use Outdoors | Mounting Fasteners Included | Mounting Hole Dia. | Display Type | Hazardous Location Rating | Enclosure Rating | Certification | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Air Conditioners and Heaters | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dial Control | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 120 to 277 | 22 | 20 to 80 | SPDT | Hardwire | 5 7/8" | 3" | 3 1/4" | 6 | No | No | 3/8" | Analog | NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 7, NEMA 9 | CSA Certified, UL Listed | 1877K24 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Adjustable-Power Temperature Controllers for Plug-In Heaters
Plug | Socket | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Output Voltage Range, V AC | Current, amp | Input Voltage, V AC | Electrical Connection | No. of Blades | NEMA Type | End Shape | NEMA Type | End Shape | Cord Lg., ft. | Ht. | Wd. | Dp. | Enclosure Rating | Each | ||
| 36 to 120 | 10 | 120 | Straight Blade | 3 | 5-15 | Straight | 5-15 | Straight | 6 | 4 5/8" | 2 11/16" | 2" | NEMA 4X, NEMA 7 | 4550T5 | 000000 | |
Hazardous Location Line-Voltage Thermostats
Overall | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage, V AC | Current, amp | Temp. Setting, ° F | Switch Designation | Electrical Connection Type | Ht. | Wd. | Dp. | For Use Outdoors | Mounting Fasteners Included | Mounting Hole Dia. | Display Type | Hazardous Location Rating | Enclosure Rating | Certification | Cannot Be Sold To | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Air Conditioners and Heaters | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dial Control | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 24 to 277 | 22 | 50 to 90 | SPDT | Hardwire | 5 3/4" | 6 3/8" | 5 5/8" | No | No | 1/4" | Analog | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 7 | CSA Certified, UL Listed | Colorado | 1877K23 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 24 to 277 | 22 | 50 to 90 | DPDT | Hardwire | 5 3/4" | 6 3/8" | 5 5/8" | No | No | 1/4" | Analog | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | NEMA 7 | CSA Certified, UL Listed | Colorado | 1877K25 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||