McMaster-Carr logo
    Filter by
    Electrical Phase
    Application
    Number of Circuits Controlled
    Switch Designation
    Measurement Unit
    Pipe Size
    Industrial Info Snippet
    Number of Outputs
    Wire Connection
    Thermocouple Probe Type
    Actuation Point Adjustability
    Probe Diameter
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    39 Products

    Washdown Threaded Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Washdown Threaded Temperature Switches.
    Turn heating equipment on or off in washdown environments. To withstand splashing water, corrosive liquid, and dust, these switches have a housing that meets NEMA 4X. The threaded probe installs directly into tanks, pipelines, and other process components. Use the adjustment dial to set actuation points.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    2 Actuation Points—Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    SPDT
    Temp. Range,
    ° F
    Temp.
    Accuracy
    No. of Actuation
    Points
    Actuation
    Tolerance
    No. of Circuits
    Controlled
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Max. Pressure,
    psi
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Certification
    Each
    Threaded Brass Probe—1/2 NPT Male
     
    Adjustable Actuation Point
    0 to 225±2° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,8979 3/8"4"2 3/8"NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    00000000000000
    0 to 225±5° F2-1% to 1%215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,8977 3/8"5 3/32"5 1/2"NEMA 4X
    UL Listed, C-UL Listed, CE Marked, FM Approved
    0000000000000
    200 to 425±4° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,7849 3/8"4"2 3/8"NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    0000000000000
     

    Washdown Wall-Mount Temperature Switches

    Image of Product. With Threaded Copper Probe. Front orientation. Threaded. Washdown Wall-Mount Temperature Switches, SPDT—1 Circuit Controlled.
    Image of Product. With Unthreaded Stainless Steel Probe. Front orientation. Temperature Switches. Washdown Wall-Mount Temperature Switches, SPDT—2 Circuits Controlled.
    Image of Product. With Unthreaded PFA-Coated Copper Probe. Front orientation. Temperature Switches. Washdown Wall-Mount Temperature Switches, Copper Probe, Unthreaded.

    With

    Threaded

    Copper

    Probe

    With

    Unthreaded

    Stainless

    Steel Probe

    With

    Unthreaded

    PFA-Coated

    Copper Probe

    To protect these switches from splashing water, corrosive liquid, and dust, the housing meets NEMA 4X for washdown conditions. Switches turn heating equipment on or off at a specified temperature. All have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
    SPDT—SPDT (Single pole, double throw) switches can be set to turn circuits from off to on (normally open) or from on to off (normally closed). Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). The probe has 1/2 NPT male threads for installation directly into tanks, pipelines, and other process components. It comes with a bushing that adapts the thread size to 3/4 NPT male. Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    DPST—DPST (Double pole, single throw) switch turns two circuits from on to off (normally closed).
    3PST—3PST (Triple pole, single throw) switches turn three circuits from on to off (normally closed).
    Probe
    Temp. Range
    Temperature
    Accuracy
    No. of Actuation
    Points
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Wire
    Connection
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Certification
    Each
    SPDT—1 Circuit Controlled
     
    Threaded Copper Probe—1/2 NPT Male
    30° F to 250° F±3° F115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"Screw Terminal8 11/16"4"2 3/8"NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    00000000000000
    100° F to 400° F±4° F115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 1/8"Screw Terminal8 11/16"4"2 3/8"NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    0000000000000
     
    SPDT—2 Circuits Controlled
     
    Unthreaded Stainless Steel Probe
    30° F to 250° F±5° F215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"Screw Terminal6 11/16"5 5/32"5 1/2"NEMA 4X
    UL Listed, C-UL Listed, CE Marked, FM Approved
    0000000000000
    100° F to 400° F±8° F215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 1/8"Screw Terminal6 11/16"5 5/32"5 1/2"NEMA 4X
    UL Listed, C-UL Listed, CE Marked, FM Approved
    0000000000000
     
    DPST—2 Circuits Controlled
     
    Unthreaded PFA-Coated Copper Probe
    70° F to 245° F/20° C to 120° C±4° F/±2.5° C125 amp @ 120V AC (Single)
    25 amp @ 240V AC (Single)
    5/16"6 1/2"Screw Terminal5 7/8"3 1/8"5"NEMA 4X
    00000000000000
     
    3PST—3 Circuits Controlled
     
    Unthreaded PFA-Coated Copper Probe
    70° F to 245° F/20° C to 120° C±4° F/±2.5° C150 amp @ 240V AC (Single, Three)5/16"6 1/2"Screw Terminal8 1/2"8 1/2"5"NEMA 4X
    0000000000000000
    70° F to 245° F/20° C to 120° C±4° F/±2.5° C150 amp @ 480V AC (Single, Three)5/16"6 1/2"Screw Terminal8 1/2"8 1/2"5"NEMA 4X
    0000000000000000
     
    Switch Mounts

    Washdown Autotuning Temperature Controllers

    The faceplate on these controllers is sealed to meet NEMA 4X and IP66 for protection in washdown environments with splashing water, corrosive liquid, and dust. The rear case meets IP20, which prevents objects about the size of a finger from coming into contact with a live circuit.
    Because they have proportional-integral-derivative (PID) software, these controllers are ideal for turning heating equipment on and off in systems with rapid, unpredictable, and complex temperature changes. They help you achieve precise and stable temperature control with fuzzy logic that learns system behavior and automatically compensates for changes. Use the autotuning function to cycle and identify the ideal PID variables for your system to achieve the most precise control. These controllers read temperature with a highly sensitive thermocouple probe (sold separately) in critical process applications. All fit into instrument panels with DIN cutouts. Use the keypad to adjust the actuation point, reset point, and other settings.
    Controllers with Mechanical Relay Heating Output
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN

    Panel Cutout Size

    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 1/8 DIN

    Panel Cutout

    Size

    For 1/4 DIN Panel

    Cutout Size

    Mechanical relay outputs actuate circuits directly.
    SPDT—Single pole, double throw (SPDT) relays can be set to turn the circuit from off to on (normally open) or from on to off (normally closed).
    SPST-NO—Single pole, single throw (SPST) relays turn one circuit from off to on (normally open).
    Automatic Reset—Controllers with automatic reset switch off and on again automatically as the temperature fluctuates.
    Manual Reset—Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
    Mechanical Relay
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset Type
    Input Voltage
    Range, V AC
    Enclosure Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    1Heating—1 Mechanical RelayHeating—SPST-NO
    Heating— 3 amp @ 220V ACThermocoupleAutomatic100 to 240IP20, IP66, NEMA 4X
    00000000000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    Heating—SPST-NO
    Alarm—SPST-NO
    Heating—3 amp @ 250V AC
    Alarming—1 amp @ 250V AC
    Thermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    0000000000000
     
    For 1/8 DIN Panel Cutout Size–For 3 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    Heating—SPDT
    Alarm—SPST-NO
    Heating— 5 amp @ 250V AC
    Alarming— 1 amp @ 250V AC
    Thermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    0000000000000
     
    For 1/4 DIN Panel Cutout Size–For 3 3/4" Ht. × 3 3/4" Wd. Panel Cutout
    3Heating—1 Mechanical Relay
    Alarming—2 Mechanical Relays
    Heating—SPDT
    Alarm—SPST-NO
    Heating—3 amp @ 250V AC
    Alarming—1 amp @ 250V AC
    Thermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    0000000000000
     
    Accessories for Temperature Controllers
    Controllers with Solid State Relay Heating Output
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/32 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.

    For 1/32 DIN Panel

    Cutout Size

    For 1/16 DIN

    Panel Cutout Size

    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 1/8 DIN

    Panel Cutout

    Size

    For 1/4 DIN Panel

    Cutout Size

    Solid state relay outputs send a pulse signal to directly control an external solid state relay (not included). They last longer than mechanical and analog signal relays. Use them for more precise and rapid control switching than mechanical relays.
    SPST-NO—Single pole, single throw (SPST) relays turn one circuit from off to on (normally open).
    Automatic Reset—Controllers with automatic reset switch off and on again automatically as the temperature fluctuates.
    Manual Reset—Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
    Mechanical Relay
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset Type
    Input Voltage
    Range, V AC
    Enclosure Rating
    Each
    For 1/32 DIN Panel Cutout Size–For 7/8" Ht. × 1 3/4" Wd. Panel Cutout
    1Heating—1 15V DC Solid State RelayThermocoupleAutomatic100 to 240IP20, IP66, NEMA 4X
    00000000000000
     
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 12V DC Solid State Relay
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    0000000000000
     
    For 1/8 DIN Panel Cutout Size–For 3 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 12V DC Solid State Relay
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    0000000000000
     
    For 1/4 DIN Panel Cutout Size–For 3 3/4" Ht. × 3 3/4" Wd. Panel Cutout
    3Heating—1 12V DC Solid State Relay
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    0000000000000
     
    Accessories for Temperature Controllers
    Controllers with Analog Signal Heating Output
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/16 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/8 DIN Panel Cutout Size.
    Image of Product. Front orientation. Temperature Controllers. Washdown Autotuning Temperature Controllers, For 1/4 DIN Panel Cutout Size.

    For 1/16 DIN

    Panel Cutout Size

    For 1/8 DIN

    Panel Cutout

    Size

    For 1/4 DIN Panel

    Cutout Size

    Analog signal outputs send 4-20 mA current to actuate equipment on a current loop. They are typically used with SRC (silicon controlled rectifier) power controllers (not included) for some of the highest precision control.
    SPST-NO—Single pole, single throw (SPST) relays turn one circuit from off to on (normally open).
    Automatic Reset—Controllers with automatic reset switch off and on again automatically as the temperature fluctuates.
    Manual Reset—Controllers with automatic/manual reset give you the choice to have machines turn back on either automatically when the temperature fluctuates, or you can manually reset their switch. When set to manual they shut down your machine when it gets too hot to protect equipment and personnel. They won’t turn the machine back on until you reset their switch. They have a second output to actuate an alarm or another simple device.
    Mechanical Relay
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    For Probe Type
    Reset Type
    Input Voltage
    Range, V AC
    Enclosure Rating
    Each
    For 1/16 DIN Panel Cutout Size–For 1 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 4 mA to 20 mA Analog Signal
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    00000000000000
     
    For 1/8 DIN Panel Cutout Size–For 3 3/4" Ht. × 1 3/4" Wd. Panel Cutout
    3Heating—1 4 mA to 20 mA Analog Signal
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    0000000000000
     
    For 1/4 DIN Panel Cutout Size–For 3 3/4" Ht. × 3 3/4" Wd. Panel Cutout
    3Heating—1 4 mA to 20 mA Analog Signal
    Alarming—2 Mechanical Relays
    SPST-NO
    1 amp @ 250V ACThermocouple, RTDAutomatic, Manual100 to 240IP20, IP66, NEMA 4X
    0000000000000
     
    Accessories for Temperature Controllers

    Hazardous Location Threaded Temperature Switches

    Image of Product. Front orientation. Temperature Switches. Hazardous Location Threaded Temperature Switches.
    Often used in hazardous locations, such as chemical plants, refineries, and grain elevators, these switches have a housing that’s UL listed for environments with flammable gases, combustible dust, and ignitable fibers. It is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. The housing also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Install the threaded probe directly into tanks, pipelines, and other process components to turn heating equipment on or off at a specified temperature. Set actuation points with the adjustment dial.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    2 Actuation Points—Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    SPDT
    Temp. Range,
    ° F
    Temp.
    Accuracy
    No. of Actuation
    Points
    Actuation
    Tolerance
    No. of Circuits
    Controlled
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Max. Pressure,
    psi
    Ht.
    Wd.
    Dp.
    Enclosure Rating
    Hazardous Location Rating
    Certification
    Each
    Threaded Brass Probe—1/2 NPT Male
     
    Adjustable Actuation Point
    0 to 225±2° F1-1% to 1%115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,89710"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    UL Listed, C-UL Listed, CE Marked
    00000000000000
    0 to 225±2° F2-1% to 1%215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    9/16"1 7/8"1,78410"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    UL Listed, C-UL Listed, CE Marked
    000000000000000
     

    Washdown Wall-Mount Autotuning Temperature Controllers

    Image of Product. Front orientation. Temperature Controllers. Washdown Wall-Mount Autotuning Temperature Controllers.
    For protection in washdown conditions with splashing water, corrosive liquid, and dust, these controllers have a wall-mount housing that meets NEMA 4X. They’re ideal for systems with rapid, unpredictable, or complex temperature changes. They turn heating equipment on and off using a proportional-integral-derivative (PID) control algorithm to make fine adjustments, giving you the most precise and stable temperature control. All work similarly to proportional controllers but gather more variables to calculate the most effective way to return to the target temperature and avoid overshooting it. They also have fuzzy logic to learn your system's behavior and compensate as needed. Use the autotuning function to have the controller cycle and identify the ideal PID variables for your system. These controllers include a highly sensitive Type J thermocouple probe to take temperature readings in critical process applications. Since they reset automatically, they switch off and on again as the temperature fluctuates. Use the keypad to adjust the actuation point, reset point, and other settings.
    The controllers have mechanical relay outputs that actuate circuits directly. All are 3PST (triple pole, single throw) and turn three circuits from off to on (normally open). They also have two additional outputs to actuate alarms or other simple devices.
    Mechanical Relay
    Probe
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Voltage,
    V AC
    Current,
    amp
    Probe Type
    Reset
    Type
    Lg.
    Dia.
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    31 Heating Output (Mechanical Relay)
    2 Alarming Outputs
    3PST
    12030ThermocoupleAutomatic1 1/4"5/16"8 1/2"8 1/2"5"NEMA 4X
    0000000000000000
    31 Heating Output (Mechanical Relay)
    2 Alarming Outputs
    3PST
    24030ThermocoupleAutomatic1 1/4"5/16"8 1/2"8 1/2"5"NEMA 4X
    000000000000000
    31 Heating Output (Mechanical Relay)
    2 Alarming Outputs
    3PST
    24050ThermocoupleAutomatic1 1/4"5/16"8 1/2"8 1/2"5"NEMA 4X
    000000000000000
    31 Heating Output (Mechanical Relay)
    2 Alarming Outputs
    3PST
    48030ThermocoupleAutomatic1 1/4"5/16"8 1/2"8 1/2"5"NEMA 4X
    000000000000000
    31 Heating Output (Mechanical Relay)
    2 Alarming Outputs
    3PST
    48050ThermocoupleAutomatic1 1/4"5/16"8 1/2"8 1/2"5"NEMA 4X
    000000000000000

    Hazardous Location Wall-Mount Temperature Switches

    Image of Product. With Threaded Probe. Front orientation. Temperature Switches. Hazardous Location Wall-Mount Temperature Switches, SPDT—1 Circuit Controlled.
    Image of Product. With Unthreaded Probe. Front orientation. Temperature Switches. Hazardous Location Wall-Mount Temperature Switches, SPDT—2 Circuits Controlled.

    With Threaded

    Probe

    With

    Unthreaded

    Probe

    Turn heating equipment on or off in environments with flammable gases, combustible dust, and ignitable fibers, such as chemical plants, refineries, and grain elevators. The switch housing is UL listed for use in Class I, Divisions 1 and 2, Groups B, C, and D; Class II, Divisions 1 and 2, Groups E, F, and G; and Class III, Divisions 1 and 2 hazardous locations. It also meets NEMA 4X for use in washdown environments with splashing water, corrosive liquid, and dust. Switches have a probe on a cable for remote temperature readings. Set actuation points with the adjustment dial.
    1 Actuation Point—Switches with one actuation point have one SPDT (single pole, double throw) relay. The relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed). The probe has 1/2 NPT male threads for installation directly into tanks, pipelines, and other process components. It comes with a bushing that adapts the thread size to 3/4 NPT male.
    2 Actuation Points—Switches with two actuation points have two SPDT (single pole, double throw) relays. Each relay can be set to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Probe
    Temp. Range
    Temp.
    Accuracy
    No. of Actuation
    Points
    Max. Switching Current @ Voltage
    (Electrical Phase)
    Dia.
    Lg.
    Ht.
    Wd.
    Dp.
    Enclosure Rating
    Hazardous Location Rating
    Includes
    Each
    SPDT—1 Circuit Controlled
     
    Threaded Stainless Steel Probe—1/2 NPT Male
    30° F to 250° F±5° F115 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"9 5/16"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    1/2 × 3/4 NPT Adapter Bushing0000000000000000
     
    SPDT—2 Circuits Controlled
     
    Unthreaded Stainless Steel Probe
    30° F to 250° F±5° F215 amp @ 125V AC (Single)
    15 amp @ 250V AC (Single)
    15 amp @ 480V AC (Single)
    3/8"2 5/8"9 5/16"5 1/8"5 3/16"IP66, NEMA 4X, NEMA 7, NEMA 9
    ATEX II 2 D Ex Tb IIIC T85° C Db
    ATEX II 2 G Ex Db IIC T6 Gb
    IEC Zone 1 Groups IIC, IIB, IIA
    IEC Zone 21 Groups IIIC, IIIB, IIIA
    IECEx Ex D IIC T6 Gb
    IECEx Ex Tb IIIC T85° C Db
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 1 Groups IIB, IIA
    000000000000000
     
    Switch Mounts

    Adjustable-Power Temperature Controllers for Plug-In Heaters

    Image of Product. Front orientation. Contains Inset. Temperature Controllers. Adjustable-Power Temperature Controllers for Plug-In Heaters.
    Regulate the amount of power flowing to your heater with the turn of a dial. Instead of a temperature sensor or input, these controllers work like a dimmer on a light switch. To incorporate them, first plug in the temperature controller, then plug your heater into the socket on the bottom of the controller. These controllers are NEMA rated for use in hazardous, corrosive, dusty, and washdown environments.
    Plug
    Socket
    Output Voltage
    Range, V AC
    Current,
    amp
    Input Voltage,
    V AC
    Electrical
    Connection
    No. of
    Blades
    NEMA
    Type
    End
    Shape
    NEMA
    Type
    End
    Shape
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Enclosure
    Rating
    Each
    36 to 12010120Straight Blade35-15
    Straight5-15
    Straight64 5/8"2 11/16"2"NEMA 4X, NEMA 7
    000000000000

    On/Off Temperature Controllers for Plug-in Heaters

    Image of Product. Front orientation. Temperature Controllers. On/Off Temperature Controllers for Plug-in Heaters, IP66, NEMA 4X—Wall Mount.

    IP66, NEMA 4X—Wall Mount

    Switch heaters on or off when your process reaches a certain temperature. Both these controllers and your heater will be powered by the same wall outlet. Place the probe into your process, plug the controller into an outlet, and plug your heater into the socket on the back of the controller’s plug. These simple temperature controllers deliver either full power or no power. They’re best used in systems where temperatures change slowly and you don’t need precise control.
    IP66 Enclosure Rating and NEMA 4X Enclosure Rating—IP66 and NEMA 4X rated controllers seal out dirt, corrosive liquids, and water from high-pressure washdowns.
    Mechanical Relay
    Probe
    Temperature Control
    Range
    No. of
    Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset
    Type
    Dia.
    Lg.
    Cable Lg.,
    ft.
    Input Voltage,
    V AC
    Ht.
    Wd.
    Dp.
    Each
    IP66, NEMA 4X—Wall Mount
    -40° F to 212° F
    -40° C to 100° C
    1Heating—1 Mechanical RelaySPDT-NO12 amp @ 120V ACAutomatic1/4"2"61206 5/8"2 13/16"2 13/16"00000000000000
     

    Washdown On/Off Temperature Controllers

    Rated IP65 and NEMA 4X to seal out water and dust, these temperature controllers turn your equipment on and off in areas with frequent washdowns. They're the simplest type of temperature controller, so they switch your heater or other device fully on or off without a middle state when they reach a given temperature. These controllers work great as alarms and in systems that can't handle rapid switching or have slow temperature changes. However, you shouldn't use them in processes that require precise control over temperatures.
    To read temperature, these controllers use a highly sensitive thermocouple or RTD probe (not included). Their mechanical relay actuates circuits directly. All are SPDT (single pole, double throw) and can turn one circuit from off to on (normally open) or on to off (normally closed). Since these controllers reset automatically, they turn off and on again as the temperature fluctuates. Use the keypad to set the actuation point, reset point, and other settings. Mount them into instrument panel cutouts.
    These controllers have UL recognized components and are CSA certified and CE marked, so they meet American, Canadian, and European safety standards.
    For Thermocouple Probe
    Image of Product. Front orientation. Temperature Controllers. Washdown On/Off Temperature Controllers.
    Mechanical Relay
    Temperature Control
    Range
    For Thermocouple
    Probe Type
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset
    Type
    Input Voltage,
    V AC
    Enclosure
    Rating
    Each
    For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    32° F to 390° F
    0° C to 200° C
    J
    1Heating—1 Mechanical RelaySPDT
    8 amp @ 240V AC
    8 amp @ 30V DC
    Automatic120IP65, NEMA 4X
    0000000000000
    32° F to 2,190° F
    0° C to 1,200° C
    K
    1Heating—1 Mechanical RelaySPDT
    8 amp @ 240V AC
    8 amp @ 30V DC
    Automatic120IP65, NEMA 4X
    000000000000
     
    For RTD Probe
    Image of Product. Front orientation. Temperature Controllers. Washdown On/Off Temperature Controllers.
    Mechanical Relay
    Temperature Control
    Range
    For RTD Probe
    Resistance, ohm
    Total No.
    of Outputs
    Output Type
    Switch
    Designation
    Max. Switching Current
    @ Voltage
    Reset
    Type
    Input Voltage,
    V AC
    Enclosure
    Rating
    Each
    For 2 11/16" Ht. × 2 11/16" Wd. Panel Cutout
    32° F to 1,470° F
    0° C to 800° C
    1001Heating—1 Mechanical RelaySPDT
    8 amp @ 240V AC
    8 amp @ 30V DC
    Automatic120IP65, NEMA 4X
    0000000000000
     
    back to top