    Hazardous Location Threaded Thermocouple Probe Transmitters for Liquids and Gases

    Image of Product. Front orientation. Thermocouples. Hazardous Location Threaded Thermocouple Probe Transmitters for Liquids and Gases .
    Image of Attribute. Front orientation. Contains Annotated. Thermocouples. Hazardous Location Threaded Thermocouple Probe Transmitters for Liquids and Gases .
    Safely measure the temperature of liquids and gases in places where flammable gases, vapors, dust, and fibers are present. The head of these transmitters is FM approved and CSA certified for use in hazardous areas. It’s also NEMA 4X and IP68 rated, so it stands up to wet and dusty environments and even brief submersion. These transmitters convert readings to analog signals and send them to devices such as remote displays and programmable logic controllers (PLCs).
    To measure liquids, you’ll need to connect a thermowell or protective tube before immersing the probe in a tank or pipe. Otherwise, liquid will be sucked into the head through the fitting, which will damage the wiring. The probe can also be used to measure solids, such as molds and dies—it's made of stainless steel or nickel to shield against impacts. It also has a layer of magnesium oxide to protect the wiring inside the probe. For accurate readings, a spring inside the fitting pushes the probe tip forward, keeping it in constant contact with the surface you're measuring. The head has a removable cap for easy access to sensor connections.
    These thermocouples are manufactured to conform to ASTM E230 for accuracy. Accuracy is how far off the reported value is from the actual temperature.
    Probe
    Probe
    Connection
    Conduit
    Connection
    Lg.
    Dia.
    Response
    Time, sec.
    Temp. Range,
    ° F
    Accuracy @ Temperature
    Overall
    Lg.
    Sensor
    Type
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Output Current
    Range, mA
    Voltage
    Range, V DC
    Enclosure
    Rating
    Hazardous Location Rating
    Each
    Type J Thermocouple
     
    316 Stainless Steel Probe
    2 1/2"1/4"50 to 500Not Rated Below 32° F
    ±4° F Between 32° F to 500° F
    8 1/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N1130000000
    4"1/4"50 to 500Not Rated Below 32° F
    ±4° F Between 32° F to 500° F
    9 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N118000000
    6"1/4"50 to 500Not Rated Below 32° F
    ±4° F Between 32° F to 500° F
    11 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N124000000
    9"1/4"50 to 500Not Rated Below 32° F
    ±4° F Between 32° F to 500° F
    14 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N129000000
    12"1/4"50 to 500Not Rated Below 32° F
    ±4° F Between 32° F to 500° F
    17 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N135000000
     
    Type K Thermocouple
     
    Nickel Probe
    2 1/2"1/4"50 to 2,150Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    8 1/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N143000000
    4"1/4"50 to 2,150Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    9 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N148000000
    6"1/4"50 to 2,150Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    11 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N154000000
    9"1/4"50 to 2,150Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    14 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N159000000
     
    316 Stainless Steel Probe
    12"1/4"50 to 2,150Not Rated Below 32° F
    ±4° F Between 32° F to 533° F
    ±0.75% Above 533° F
    17 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N165000000
     
    Type T Thermocouple
     
    316 Stainless Steel Probe
    2 1/2"1/4"5-328 to 100Not Rated Below 32° F
    ±1.8° F Between 32° F to 100° F
    8 1/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N167000000
    4"1/4"5-328 to 100Not Rated Below 32° F
    ±1.8° F Between 32° F to 100° F
    9 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N173000000
    6"1/4"5-328 to 100Not Rated Below 32° F
    ±1.8° F Between 32° F to 100° F
    11 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N178000000
    9"1/4"5-328 to 100Not Rated Below 32° F
    ±1.8° F Between 32° F to 100° F
    14 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N184000000
    12"1/4"5-328 to 100Not Rated Below 32° F
    ±1.8° F Between 32° F to 100° F
    17 5/8"Ungrounded1/2
    NPT
    Male3/4
    NPT
    Female4 to 208 to 35IP68, NEMA 4X
    NEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    4635N189000000
     