Filter by
Electrical Connection
Maximum Temperature
Probe Length
Thermocouple Sensor Connection
Sensor Type
Cable Material
Probe Connection
Thermometer Type
Component
Measurement Unit
Accuracy @ Temperature
Thermometer Features
Export Control Classification Number (ECCN)
DFARS Specialty Metals
About Temperature Sensors
Choose between RTDs and thermocouples based on your application's maximum temperature, duration, and environment.
Thermocouple Probes for Air and Surfaces
Probes with Cable
Probe | Cable | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | Dia. | Response Time, sec. | Max. Temp., ° F | Accuracy @ Temperature | Sensor Type | Style | Lg., ft. | Material | Max. Temp., ° F | Each | |||
Type J | |||||||||||||
Flat-Pin Mini Thermocouple Connector | |||||||||||||
| 1/8" | 1/8" | 7 | 400 | ±4° F Between 32° F to 400° F | Exposed | Straight | 3 | FEP | 400 | 6441T674 | 000000 | ||
| 1/8" | 1/8" | 7 | 400 | ±4° F Between 32° F to 400° F | Exposed | Straight | 15 | FEP | 400 | 6441T824 | 00000 | ||
Round-Pin Thermocouple Connector | |||||||||||||
| 1/8" | 1/8" | 0.25 | 900 | ±4° F Between 32° F to 533° F ±0.75% Above 533° F | Exposed | Straight | 3 | Fiberglass | 900 | 6441T11 | 00000 | ||
| 1/8" | 1/8" | 0.25 | 900 | ±4° F Between 32° F to 533° F ±0.75% Above 533° F | Exposed | Straight | 9 | Fiberglass | 900 | 6441T12 | 00000 | ||
| 1/8" | 1/8" | 0.25 | 900 | ±4° F Between 32° F to 533° F ±0.75% Above 533° F | Exposed | Straight | 16 | Fiberglass | 900 | 6441T13 | 00000 | ||
Type K | |||||||||||||
Round-Pin Thermocouple Connector | |||||||||||||
| 1/8" | 1/8" | 0.25 | 900 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | Exposed | Straight | 3 | Fiberglass | 900 | 6441T14 | 00000 | ||
| 1/8" | 1/8" | 0.25 | 900 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | Exposed | Straight | 9 | Fiberglass | 900 | 6441T15 | 00000 | ||
| 1/8" | 1/8" | 0.25 | 900 | Not Rated Below 32° F ±4° F Between 32° F to 533° F ±0.75% Above 533° F | Exposed | Straight | 16 | Fiberglass | 900 | 6441T16 | 00000 | ||
Type T | |||||||||||||
Round-Pin Thermocouple Connector | |||||||||||||
| 1/8" | 1/8" | 0.25 | 700 | Not Rated Below 32° F ±1.8° F Between 32° F to 240° F ±0.75% Above 240° F | Exposed | Straight | 3 | Fiberglass | 900 | 6441T17 | 00000 | ||
| 1/8" | 1/8" | 0.25 | 700 | Not Rated Below 32° F ±1.8° F Between 32° F to 240° F ±0.75% Above 240° F | Exposed | Straight | 9 | Fiberglass | 900 | 6441T18 | 00000 | ||
| 1/8" | 1/8" | 0.25 | 700 | Not Rated Below 32° F ±1.8° F Between 32° F to 240° F ±0.75% Above 240° F | Exposed | Straight | 16 | Fiberglass | 900 | 6441T19 | 00000 | ||
Data-Logging Handheld Thermometers
![]() | ![]() | ![]() | ![]() |
2 Probe Inputs | 3 Probe Inputs | 4 Probe Inputs | 12 Probe Inputs |
Thermometers | Replacement Probes | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Probe | ||||||||||||||||
No. of Probe Inputs | Temp. Range | Resolution, ° C | Accuracy | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Thermometer Features | Certification | Batteries Included | Each | Each | ||||
For Use With Air, Gas, and Surfaces | ||||||||||||||||
Thermometers with Carrying Case, Protective Holster, RS-232 Port, and Windows-Compatible Software and Cable | ||||||||||||||||
| 2 | -22° F to 572° F/-30° C to 300° C | 0.1/0.1 | ±1.75° F/±0.90° C | 1.5 | 3 | 1/8" | 3/16" | Automatic Shutoff, Backlit Display, Built-In Stand, Min./Max. Memory, Real-Time Clock | CE Marked | Yes | 9281T44 | 0000000 | 9281T21 | 000000 | ||
Thermometers with SD Memory Card and RS-232 Port | ||||||||||||||||
| 3 | -40° F to 482° F/-40° C to 250° C | 0.1/0.1 | ±12.86° F/±7° C | 1 | 3 | 1/8" | 3/16" | Backlit Display, Built-In Stand, Real-Time Clock | CE Marked | Yes | 9281T51 | 000000 | 9281T21 | 00000 | ||
Thermometers with SD Memory Card, Carrying Case, and RS-232 Port | ||||||||||||||||
| 4 | -40° F to 392° F/-40° C to 200° C | 0.1/0.1 | ±5.8° F/±4.4° C | 1 | 3 | 1/8" | 3/16" | Automatic Shutoff, Backlit Display, Built-In Stand, Min./Max. Memory, Real-Time Clock | CE Marked | Yes | 9281T52 | 000000 | 9281T21 | 00000 | ||
Thermometers with SD Memory Card and Carrying Case | ||||||||||||||||
| 12 | -40° F to 482° F/-40° C to 250° C | 0.1/0.1 | ±1.8° F/±1° C | 1 | 3 | 1/8" | 3/16" | Automatic Shutoff, Backlit Display, Data Logging Capabilities | CE Marked | Yes | 9281T54 | 00000000 | 9281T21 | 00000 | ||