McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    19 Products

    Thermoelectric Coolers

    Image of System. Cooler Shown with Extension Bracket Installed. Front orientation. ZoomedIn view. Contains Border. Thermoelectric Coolers.

    Cooler Shown with Extension

    Bracket Installed

    Image of Product. Front orientation. Thermoelectric Coolers.
    Image of Product. Front orientation. Thermoelectric Cooler Extension Brackets.
    Image of Product. Front orientation. Thermoelectric Cooler Drain Kits.

    Extension

    Brackets

    Drain Kits

    Also known as Peltier coolers, these coolers use electrical current to transfer heat away from your enclosure while sealing out contaminants. They cool the enclosure to below the ambient temperature. The solid-state thermoelectric components require no maintenance and take up less space than an air conditioner or heat exchanger.
    Rated IP66 and NEMA 4X, these coolers withstand weather, washdowns, and corrosive environments. They meet American and European safety standards.
    Thermostat Not Included—Coolers without a thermostat run continuously when powered. Add a thermostat, timer, or switch to turn them on and off.
    Extension Brackets—An extension bracket holds the cooler away from the enclosure wall for more space inside the enclosure.
    Drain Kits—Add a drain kit to remove moisture when condensation is likely, such as in humid environments and enclosures exposed to rapid temperature changes. The included hose directs water away from electrical components.
    Coolers
    Extension
    Brackets
    Drain Kits
    Overall
    For
    Opening
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Wattage,
    W
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Environment
    Mounting Fasteners
    Included
    Each
    Each
    Each
    Thermostat Not Included
     
    12V DC—Terminal Block
    10010302.94 5/16"6 1/8"5"3 9/16"4 13/16"Corrosive, Dusty, Outdoor, Washdown, WetYes3836N1100000003836N29100000003836N230000000
     
    24V DC—Terminal Block
    17010502.58 1/8"6 1/8"5 5/16"6 11/16"4 3/4"Corrosive, Dusty, Outdoor, Washdown, WetYes3836N120000003836N2920000003836N23000000
    340251004.97 7/8"12"5 3/8"6 5/16"10 1/4"Corrosive, Dusty, Outdoor, Washdown, WetYes3836N13000000003836N293000003836N25000000
    510351507.515 3/4"7 1/8"6 11/16"14 5/8"6 1/8"Corrosive, Dusty, Outdoor, Washdown, WetYes3836N15000000003836N2950000003836N24000000
    6807020011.615 3/4"7 1/8"6 11/16"14 5/8"6 1/8"Corrosive, Dusty, Outdoor, Washdown, WetYes3836N16000000003836N2950000003836N24000000
     
    48V DC—Terminal Block
    850702509.315 3/4"7 1/8"6 11/16"14 5/8"6 1/8"Corrosive, Dusty, Outdoor, Washdown, WetYes3836N17000000003836N2950000003836N24000000
     
    Adjustable Thermostat Included (68° F to 122° F)
     
    120V AC to 230V AC, Single Phase, 50 Hz/60 Hz—Terminal Block
    2,730280800838 1/4"20 1/4"8 5/16"36 5/16"18 5/16"Corrosive, Dusty, Outdoor, Washdown, WetYes3836N220000000003836N370000003836N28000000
     
    120V AC, Single Phase, 60 Hz—Terminal Block
    510351801.519 3/4"13 1/8"7 1/8"18 5/8"11 15/16"Corrosive, Dusty, Outdoor, Washdown, WetYes3836N181000000003836N350000003836N25000000
     
    230V AC, Single Phase, 50 Hz/60 Hz—Terminal Block
    510351800.819 3/4"13 1/8"7 1/8"18 5/8"11 15/16"Corrosive, Dusty, Outdoor, Washdown, WetYes3836N182000000003836N350000003836N25000000
     
    back to top