About Safety Ratings for Electrical Testing
More
Surface-Mount Motor Voltage Monitors

Protect electric motors from phase loss, phase reversal, overvoltage, undervoltage, and voltage imbalance. Also known as voltage-monitoring relays, these monitors cut power to a motor when a fault occurs.
For technical drawings and 3-D models, click on a part number.
Trip Time, sec. | Switching | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage Range | No. of Terminals | Control Power, W | Voltage Imbalance Adjustment | Automatic Reset | Delayed Automatic Reset | Current, A | Voltage | Ht. | Wd. | Specifications Met | Each | |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
Three Phase | ||||||||||||
190-480V AC | 7 | 6 | 2%-8% | 1-30 | 1-500 | 10 | 240V AC | 3.5" | 2.08" | UL Listed | 0000000 | 0000000 |
475-600V AC | 7 | 6 | 2%-8% | 1-30 | 1-500 | 10 | 240V AC | 3.5" | 2.08" | UL Listed | 0000000 | 000000 |
DIN-Rail Mount Motor Voltage Monitors

Mount these monitors to 35 mm DIN rail. They protect electric motors from phase loss, phase reversal, overvoltage, undervoltage, and voltage imbalance. Also known as voltage-monitoring relays, they cut power to a motor when a fault occurs.
For technical drawings and 3-D models, click on a part number.
Switching | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage Range | No. of Terminals | Control Power, W | Voltage Imbalance Adjustment | Trip Time, sec. | Reset Type | Current, A | Voltage | Horsepower @ Voltage | Ht. | Wd. | Specifications Met | Each | |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
Three Phase | |||||||||||||
200-480V AC | 9 | 5 | 2%-10% | 1-30 | Automatic | 10 | 240V AC | 1/3 hp @ 240 V AC | 3" | 2" | UL Listed, C-UL Listed | 0000000 | 0000000 |
Socket-Mount Motor Voltage Monitors

Plug these monitors into relay sockets for fast installation and replacement. They protect electric motors from phase loss, phase reversal, overvoltage, undervoltage, and voltage imbalance. Also known as voltage-monitoring relays, they cut power to a motor when a fault occurs.
Relay sockets (sold separately) mount to 35 mm DIN rail or flat surfaces.
Voltage Monitors | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching | Relay Sockets | |||||||||||||
Input Voltage Range | No. of Terminals | Control Power, W | Voltage Imbalance Adjustment | Trip Time, sec. | Reset Type | Current, A | Voltage | Ht. | Wd. | Specifications Met | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||
Three Phase | ||||||||||||||
200-480V AC | 8 | 5 | 2%-10% | 0.25-30 | Automatic | 10 | 240V AC | 2.4" | 1.8" | UL Recognized Component, CSA Certified | 0000000 | 0000000 | 0000000 | 00000 |
Motor Phase Sequence Testers

Incorrect motor rotation can be caused by a miswired connection from your motor to a three-phase electrical system. Use this tester to check the phase rotation (clockwise or counter-clockwise) of the motor and the electrical system to confirm proper wiring.
Test Leads | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Measures | AC Voltage | Frequency, Hz | Display Type | Safety Rating | Includes | No. of | Lg. | Batteries Required | Batteries Included | Each | |
Open Phases, Three-Phase Rotation | 40-600 | 2-400 | Light Indicator | CAT III, 600V | Alligator Clips, Carrying Case, Test Leads | 3 | 50" | Yes | Yes | 000000 | 0000000 |