About Timer Relays
More
Timer Relays
Turn machinery, such as paint and conveyor lines, on and off after a set period of time. These timer relays plug into relay sockets (sold separately) for fast installation and replacement.
Relay sockets mount on 35 mm DIN rail (also known as DIN 3) or flat surfaces.
For technical drawings and 3-D models, click on a part number.
Timer Relays | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | Switching Current | Relay Sockets | |||||||||||
Number of Terminals | Input Voltage | Control Current, mA | No. of | Overall | @ 240V AC | @ 24V DC | Max. Switching Voltage | hp @ Switching Voltage | Timing Adjustment Style | Each | Each | ||
Delayed Start (Delay-on-Make) | |||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
8 | 24V AC | 135 | 5 | 0.05 sec.-999 min. | 10A | __ | 240V AC | __ | Push Button | 000000 | 0000000 | 0000000 | 00000 |
8 | 120V AC | 27 | 5 | 0.05 sec.-999 min. | 10A | __ | 240V AC | __ | Push Button | 000000 | 000000 | 0000000 | 0000 |
8 | 240V AC | 14 | 5 | 0.05 sec.-999 min. | 10A | __ | 240V AC | __ | Push Button | 000000 | 000000 | 0000000 | 0000 |
8 | 24V AC, 24V DC | 83 | 1 | 0.1 sec.-10 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 24V AC, 24V DC | 83 | 1 | 0.6 sec.-60 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.05 sec.-1 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.1 min.-10 min. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.1 sec.-10 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.3 sec.-30 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.6 min.-60 min. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.6 sec.-60 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 1.8 sec.-180 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 3 sec.-300 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 170 | 1 | 0.1 sec.-10 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 170 | 1 | 0.6 sec.-60 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 271 | 5 | 0.05 sec.-999 min. | 10A | __ | 240V AC | __ | Push Button | 000000 | 000000 | 0000000 | 0000 |
8 | 24V DC | 135 | 5 | 0.05 sec.-999 min. | 10A | __ | 240V AC | __ | Push Button | 000000 | 000000 | 0000000 | 0000 |
Delayed Off | |||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
8 | 24V AC, 24V DC | 100 | 8 | 0.05 sec.-1,800 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 20 | 8 | 0.05 sec.-1,800 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
Interval | |||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
8 | 24V AC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 120V AC | 27 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 240V AC | 14 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.05 sec.-5 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.1 min.-10 min. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.6 min.-60 min. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.6 sec.-60 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 271 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 24V DC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
Switch-On (Single-Shot) | |||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
8 | 24V AC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 120V AC | 27 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 240V AC | 14 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.1 sec.-10 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.6 sec.-60 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 271 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 24V DC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
Delayed Switch-Off (Delay-on-Break) | |||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
8 | 24V AC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC | 1/3 hp @ 120 V AC, 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 120V AC | 27 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC | 1/3 hp @ 120 V AC, 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 240V AC | 14 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC | 1/3 hp @ 120 V AC, 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 271 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC | 1/3 hp @ 120 V AC, 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 24V DC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC | 1/3 hp @ 120 V AC, 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
11 | 24V AC, 24V DC | 83 | 1 | 0.1 sec.-10 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 00000 |
11 | 24V AC, 24V DC | 83 | 1 | 0.6 min.-60 min. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 00000 |
11 | 24V AC, 24V DC | 83 | 1 | 0.6 sec.-60 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC, 120V DC | 17 | 1 | 0.05 sec.-5 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC, 120V DC | 17 | 1 | 0.1 min.-10 min. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC, 120V DC | 17 | 1 | 0.1 sec.-10 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC, 120V DC | 17 | 1 | 0.3 sec.-30 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC, 120V DC | 17 | 1 | 0.6 min.-60 min. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC, 120V DC | 17 | 1 | 0.6 sec.-60 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC, 120V DC | 17 | 1 | 1.2 sec.-120 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 000000 | 00000 | 0000000 | 00000 |
11 | 120V AC, 120V DC | 17 | 1 | 1.8 sec.-180 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 00000 |
11 | 120V AC, 120V DC | 17 | 1 | 3 sec.-300 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 00000 |
Repeat Cycle | |||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
8 | 24V AC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 120V AC | 27 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 240V AC | 14 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 24V AC, 24V DC | 83 | 1 | 0.1 sec.-10 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 000000 | 0000000 | 0000 |
8 | 24V AC, 24V DC | 83 | 1 | 0.6 sec.-60 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 000000 | 0000000 | 0000 |
8 | 24V AC, 24V DC | 83 | 1 | 1.8 sec.-180 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 000000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.05 sec.-5 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 000000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.1 min.-10 min. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 000000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.1 sec.-10 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 000000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.3 min.-30 min. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 000000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 0.6 sec.-60 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 000000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 1.8 sec.-180 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 000000 | 0000000 | 0000 |
8 | 120V AC, 120V DC | 17 | 1 | 3 sec.-300 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 000000 | 0000000 | 0000 |
8 | 12V DC | 170 | 1 | 1.8 sec.-180 sec. | 10A | 8A | 240V AC/30V DC | 1/3 hp @ 240 V AC | Knob | 0000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 271 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 24V DC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
Solid State Versa-Mount Multifunction Timer Relays
Install these relays in a panel cutout or plug them into a relay socket. Unlike mechanical relays, these solid state relays have no moving parts, so they require less maintenance and last longer, are quieter, and switch faster. They give you a variety of timing functions in one relay.
Single-circuit relays give you additional flexibility—they have two types of delayed switch-off (delay-on-break) functions and two types of signal on/off delay functions.
Relay sockets (sold separately) mount to
Mounting brackets (sold separately) are required to mount relays into a panel cutout.
Timer Relays | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | Relay Sockets | ||||||||||||
No. of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ 240V AC | Ht. | Wd. | Dp. | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
11 | 24V AC, 48V AC, 120V AC, 240V AC, 12V DC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 17 | Delayed Start (Delay-on-Make) Interval Switch-On (Single-Shot) Delayed Switch-Off (Delay-on-Break) Repeat Cycle | 7 | 0.1 sec.-999 hrs. | 3A | 1.9" | 1.9" | 2.7" | 0000000 | 0000000 | 0000000 | 000000 |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
8 | 120V AC, 240V AC, 110V DC, 120V DC | 13 | Delayed Start (Delay-on-Make) Interval Switch-On (Single-Shot) Repeat Cycle | 4 | 0.05 sec.-300 hrs. | 5A | 1.9" | 1.9" | 2.3" | 00000000 | 000000 | 0000000 | 0000 |
Mounting Hole | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Material | Mounting Location | No. of | Ctr.-to-Ctr. | Dia. | Mounting Fasteners Included | Screw Size | Ht. | Wd. | Each | |
Polycarbonate | Panel | 2 | 3" | 5mm | Yes | M5 | 2.28" | 1.89" | 0000000 | 000000 |
Multifunction Timer Relays
Get a variety of timing functions in a single relay. All relays plug into relay sockets (sold separately) for fast installation and replacement.
Relay socket/panel mount relays require a mounting bracket (sold separately) to mount in a panel cutout.
Relay sockets mount to 35 mm DIN rail (also known as DIN 3 rail) or can be mounted to a flat surface.
Timer Relays | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | Relay Sockets | |||||||||||||
Number of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ 240V AC | Max. Switching Voltage | Ht. | Wd. | Dp. | Each | Each | ||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||||
Relay Socket Mounting Location | ||||||||||||||
11 | 24V AC | 83 | Delayed Start (Delay-on-Make) Interval Switch-On (Single-Shot) Delayed Switch-Off (Delay-on-Break) Repeat Cycle | 5 | 0.05 sec.-999 min. | 10A | 240V AC | 2.4" | 1.8" | 3.7" | 0000000 | 0000000 | 0000000 | 000000 |
11 | 120V AC | 17 | Delayed Start (Delay-on-Make) Interval Switch-On (Single-Shot) Delayed Switch-Off (Delay-on-Break) Repeat Cycle | 5 | 0.05 sec.-999 min. | 10A | 240V AC | 2.4" | 1.8" | 3.7" | 0000000 | 000000 | 0000000 | 00000 |
11 | 240V AC | 8 | Delayed Start (Delay-on-Make) Interval Switch-On (Single-Shot) Delayed Switch-Off (Delay-on-Break) Repeat Cycle | 5 | 0.05 sec.-999 min. | 10A | 240V AC | 2.4" | 1.8" | 3.7" | 0000000 | 000000 | 0000000 | 00000 |
11 | 12V DC | 167 | Delayed Start (Delay-on-Make) Interval Switch-On (Single-Shot) Delayed Switch-Off (Delay-on-Break) Repeat Cycle | 5 | 0.05 sec.-999 min. | 10A | 240V AC | 2.4" | 1.8" | 3.7" | 0000000 | 000000 | 0000000 | 00000 |
11 | 24V DC | 83 | Delayed Start (Delay-on-Make) Interval Switch-On (Single-Shot) Delayed Switch-Off (Delay-on-Break) Repeat Cycle | 5 | 0.05 sec.-999 min. | 10A | 240V AC | 2.4" | 1.8" | 3.7" | 0000000 | 000000 | 0000000 | 00000 |
Relay Socket/Panel Mounting Location | ||||||||||||||
11 | 24V AC, 48V AC, 120V AC, 240V AC, 24V DC, 48V DC, 60V DC, 120V DC, 240V DC | 104 | Delayed Start (Delay-on-Make) Interval Switch-On (Single-Shot) Delayed Switch-Off (Delay-on-Break) Repeat Cycle | 6 | 0.05 sec.-999 hrs. | 10A | 240V AC | 1.9" | 1.9" | 2.8" | 000000 | 000000 | 0000000 | 00000 |
Mounting Hole | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Material | Mounting Location | No. of | Ctr.-to-Ctr. | Dia. | Mounting Fasteners Included | Screw Size | Ht. | Wd. | Each | |
Polycarbonate | Panel | 2 | 3" | 5mm | Yes | M5 | 2.28" | 1.89" | 0000000 | 000000 |
Solid State Versa-Mount Timer Relays
Mount these timer relays in a panel cutout or plug them into a relay socket for quick installation. Capable of fast switching, they are solid state and have no moving parts, so they require less maintenance, last longer, and are quieter than mechanical relays.
Relay sockets (sold separately) mount to 35 mm DIN rail (also known as DIN 3 rail) or can be mounted to a flat surface.
Mounting brackets (sold separately) are required to mount the relay into a panel.
Timer Relays | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | Relay Sockets | |||||||||||
Number of Terminals | Input Voltage | Control Current, mA | No. of | Overall | Switching Current @ 240V AC | Ht. | Wd. | Dp. | Each | Each | ||
Delayed Off | ||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||
8 | 120V AC | 2 | 4 | 0.05 sec.-12 sec. | 5A | 1.9" | 1.9" | 2.74" | 00000000 | 0000000 | 0000000 | 00000 |
8 | 120V AC | 2 | 4 | 3 sec.-12 min. | 5A | 1.9" | 1.9" | 2.74" | 00000000 | 000000 | 0000000 | 0000 |
Repeat Cycle | ||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||
8 | 120V AC, 240V AC, 110V DC, 120V DC | 100 | 4 | 0.05 sec.-300 hrs. | 5A | 1.9" | 1.9" | 3.3" | 00000000 | 000000 | 0000000 | 0000 |
Mounting Hole | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Material | Mounting Location | No. of | Ctr.-to-Ctr. | Dia. | Mounting Fasteners Included | Screw Size | Ht. | Wd. | Each | |
Polycarbonate | Panel | 2 | 3" | 5mm | Yes | M5 | 2.28" | 1.89" | 0000000 | 000000 |