McMaster-Carr logo
    Filter by
    Power Source
    Timing Functions
    System of Measurement
    Number of Displays
    Mounting Location
    Timer Resolution
    Minimum Temperature
    Maximum Number of Events
    Maximum Alarm Duration
    Maximum Timer Duration
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Case Color
    Electrical Connection
    Frequency
    Battery Size
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    27 Products
    About Timers
    industrial info icon

    Choose a timer with the right mode for your task, whether you’re counting up, counting down, or using split‑timing to combine multiple event times.

    Digital Timers

    Image of Product. Front orientation. Timers. Digital Timers, Style L.

    Style L

    Memory Function—Timers with a memory function automatically return the display to the last programmed time. Good for timing repetitive intervals.
    IP65 Enclosure Rating—IP65-rated timers protect against dust and low-pressure washdowns. They also resist impacts up to 4 ft.
    Case
    Style
    Timing Functions
    Max. No.
    of Events
    Max. Timer
    Duration, hr.
    Max. Alarm
    Duration, min.
    Timer Resolution,
    sec.
    Ht.
    Wd.
    Dp.
    Material
    Color
    Batteries
    Included
    Features
    Enclosure
    Rating
    Each
    LCount Up
    Count Down
    124515 1/4"7 3/4"1"PlasticBlackYesAlarm
    Built-In Stand
    Memory Function
    IP65
    12595T23000000
     

    Preventative Maintenance and Inspection Indicators

    Image of ProductInUse. Front orientation. Inspection Indicators. Preventative Maintenance and Inspection Indicators.
    Image of Product. Front orientation. Inspection Indicators. Preventative Maintenance and Inspection Indicators.
    Mount these indicators to your equipment, and their bright LED will catch your attention when it’s time for maintenance or inspection. They’re commonly used to keep track of maintenance on production lines and HVAC systems, or paired with inspection tags on fire extinguishers and eye wash stations.
    When first set, these indicators flash a dark green and then a light green color every two minutes. As a scheduled inspection approaches, they flash a yellow light every 10 seconds. And when an inspection is past due, they blink red every two seconds. Reset indicators to start the countdown again. They meet IP65, so they seal out dust and low-pressure washdowns.
    Timing
    Cycle, day
    Resettable
    Dia.
    Ht.
    Thk.
    Batteries
    Included
    Mounting Fasteners
    Included
    Enclosure
    Rating
    Each
    Screw On, Hanging Mount, Tie On
    7Yes2 1/2"3 5/8"7/8"YesYesIP65
    3545N1000000
    30Yes2 1/2"3 5/8"7/8"YesYesIP65
    3545N200000
    180Yes2 1/2"3 5/8"7/8"YesYesIP65
    3545N400000
    365Yes2 1/2"3 5/8"7/8"YesYesIP65
    3545N500000
     

    Switch-Contact-Actuated Hour Meters

    Image of Product. Front orientation. Hour Meters. Switch-Contact-Actuated Hour Meters, Screw On.

    Screw On

    No need for a separate power source—these hour meters are powered by internal batteries that last more than 10 years. Often used where power sources aren’t easily accessible, they work well in remote monitoring systems, industrial equipment, and machinery. Wire the hour meter to a relay or switch on your machine so it can receive signals when the machine is running. The total number of hours is shown on the display. Press a button on the meter to reset the time to zero or connect it to a switch or button to reset it from a distance.
    IP65 Enclosure Rating, NEMA 4X Enclosure Rating, and NEMA 12 Enclosure Rating—Screw on hour meters are IP65, NEMA 4X, and NEMA 12 rated, so they’re protected from dust, water, and splashing oil and coolant.
    UL Recognized Component, C-UL Recognized Component, and CE Marked—These meters are UL recognized, C-UL recognized, and CE marked, so they meet American, Canadian, and European safety standards.
    For Panel
    Cutout
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    Wd.
    Ht.
    Ht.
    Wd.
    Dp.
    Features
    Enclosure Rating
    Certification
    Each
    Screw On
     
    Screw-Terminal Wire Connection
    YesUp and Down81.8"0.9"1"1.9"2.1"Battery-Powered Display, Manual Reset Button, Remote ResetIP65, NEMA 4X, NEMA 12
    UL Recognized Component, C-UL Recognized Component, CE Marked
    17015T12000000
     

    Panel-Mount Electrically Actuated Hour Meters

    Image of Product. Front orientation. Hour Meters. Panel-Mount Electrically Actuated Hour Meters, Screw On, Style G.

    Screw On

    Style G

    Display running time on a machine so you can schedule preventative maintenance.
    Not Resettable—Non-resettable meters prevent tampering and accidental loss of data.
    NEMA 4X Enclosure Rating—Meters that are rated NEMA 4X are protected from dust and washdowns and can be used outdoors.
    Overall
    Style
    Resettable
    Counting
    Direction
    No. of
    Digits
    For Panel
    Cutout Dia.
    Dp.
    Dia.
    Operating
    Voltage
    Enclosure
    Rating
    Each
    Screw On
     
    0.25" Quick-Disconnect Terminals
    GNoUp62"1.3"2.8"24V ACIP65, NEMA 4X
    1672T85000000
    GNoUp62"1.3"2.8"120V ACIP65, NEMA 4X
    1672T8400000
    GNoUp62"1.3"2.8"230V ACIP65, NEMA 4X
    1672T8900000
     

    IO-Link I/O Modules

    Image of System. Components Sold Separately. Front orientation. Contains Annotated. I/O Modules.

    Components Sold Separately

    Create a system of sensors and actuators that you can remotely update, view measurements from, and receive error messages in real time. IO-Link systems minimize downtime by locating issues such as cut cables or dirty sensors quickly. They send only digital signals to your PLC, regardless of whether your sensors and actuators send digital or analog signals. Because these systems send digital signals, they’re more reliable and less prone to data error and signal loss than analog signals. It also means you don't have to use expensive shielded cables since they resist EMI.
    When retrofitting an existing system, you'll need to make sure your PLC can incorporate IO-Link. Check with your PLC manufacturer—most have hardware that allows you to upgrade your PLC to run IO-Link.
    Note: Sockets may have extra holes on their face that are not used.
    Expansion Modules
    Image of Product. Front orientation. I/O Modules. Expansion Modules.
    Expansion modules increase the number of inputs and outputs in your IO-Link system, so you can add more sensors and actuators to your network. Connect multiple devices to each expansion module using M12 connectors, without needing to wire your devices inside a control cabinet. They transmit signals from multiple devices with a single cord. Expansion modules are optional, but when used, they must connect to a controller. Mount them on your equipment to save space in your control cabinet.
    IP65 Enclosure Rating—IP65 rated components can be rinsed.
    IP67 Enclosure Rating—IP67 rated components can be temporarily submerged in water.
    IP69K Enclosure Rating—IP69K rated components hold up to high-pressure and high-temperature washdowns.
    Enclosure Rating—IP rated components block out dust and withstand some water, so they do not require an enclosure. Ports that are unused must be capped to maintain their rating.
    Input
    Output
    Expansion Module
    Type
    Communication
    Protocol
    No. of Device
    Ports
    Total No. of
    M12 Connections
    Type
    Digital
    Signal
    Voltage,
    V DC
    No.
    of
    Type
    Digital
    Signal
    Current,
    amp
    No.
    of
    Operating
    Voltage, V DC
    Certification
    Each
    Surface Mount
     
    IP65, IP67
    InputIO-Link67DigitalPNP16 to 301218 to 30UL Listed, C-UL Listed, CE Marked
    7603N110000000
    InputIO-Link1011DigitalPNP16 to 302018 to 30UL Listed, C-UL Listed, CE Marked
    7603N12000000
    Input, OutputIO-Link810DigitalPNP18 to 3016DigitalPNP3.61618 to 30CE Marked
    7603N15000000
    OutputIO-Link68DigitalPNP3.61218 to 30UL Listed, C-UL Listed, CE Marked
    7603N13000000
    OutputIO-Link1012DigitalPNP3.62018 to 30UL Listed, C-UL Listed, CE Marked
    7603N14000000
     
    IP65, IP67, IP69K
    InputIO-Link67DigitalPNP16 to 301218 to 30UL Listed, C-UL Listed, CE Marked
    7603N16000000
    InputIO-Link1011DigitalPNP16 to 302018 to 30UL Listed, C-UL Listed, CE Marked
    7603N17000000
    Input, OutputIO-Link810DigitalPNP18 to 3016DigitalPNP3.61618 to 30CE Marked
    7603N21000000
    OutputIO-Link68DigitalPNP3.61218 to 30UL Listed, C-UL Listed, CE Marked
    7603N18000000
    OutputIO-Link1012DigitalPNP3.62018 to 30UL Listed, C-UL Listed, CE Marked
    7603N19000000
     
    Converters
    Image of Product. Front orientation. Signal Converters.
    Converters translate analog signals to digital signals, making sensors and actuators IO-Link compatible. They are required to connect analog components to controllers and modules.
    IP67 Enclosure Rating—IP67 rated components can be temporarily submerged in water.
    Input
    Output
    Signal Converter Type
    Total No. of
    M12 Connections
    Signal
    Type
    Digital
    Signal
    Analog Signal
    No.
    of
    Signal Type
    Digital
    Signal
    Analog Signal
    No.
    of
    Certification
    Each
    M12 Plug In
     
    Washdown (IP67)
    Analog to Digital2Analog0V DC to 10V DC2DigitalPNP1UL Listed, C-UL Listed, CE Marked
    7603N520000000
    Analog to Digital to Analog2Analog4 mA to 20 mA1Digital, AnalogPNP4 mA to 20 mA2UL Listed, C-UL Listed, CE Marked
    7603N51000000
    Digital to Analog2DigitalPNP1Analog0V DC to 10V DC2UL Listed, C-UL Listed, CE Marked
    7603N53000000
    Digital to Analog2DigitalPNP1Analog4 mA to 20 mA2UL Listed, C-UL Listed, CE Marked
    7603N54000000
     
    Caps
    Image of Product. Front orientation. Metric Circular Connector Caps. For Plugs.

    For Plugs

    Image of Product. Front orientation. Metric Circular Connector Caps. For Sockets.

    For Sockets

    Protective caps prevent dust and debris from harming M12 connections when they're not in use. They also help maintain IP ratings by covering unused ports.
    Stainless Steel—Stainless steel protective caps have a neoprene gasket, which helps maintain IP69K ratings.
    For
    Thread
    Size
    Location
    Material
    Temp. Range,
    ° F
    Includes
    Each
    For Plugs, For Receptacles
    M12
    ExternalAnodized Aluminum0 to 220Lanyard6897K73000000
    M12
    ExternalStainless Steel0 to 220Lanyard6897K7500000
     
    For Receptacles, For Sockets
    M12
    InternalAnodized Aluminum0 to 2206897K7400000
    M12
    InternalStainless Steel0 to 220Lanyard6897K5900000
     
    back to top