    163 Products

    Outdoor Durable Disconnect Switches

    All switches have quick-make/quick-break action to eliminate arcing and prolong switch life.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Outdoor Durable Disconnect Switches.
    Enamel-Coated Steel Housing and Powder-Coated Steel Housing—The enclosure is steel, so it withstands tougher conditions than plastic enclosures.
    Fuse Holder—Use switches with a fuse holder where overload protection is needed. When the current exceeds the rating of the fuse, it blows. This interrupts the circuit and prevents overheating, damage, and fire. When used with UL Class RK1, RK5, or T fuses, they require rejection-style fuse clips. Note: Horsepower ratings are based on time-delay fuses installed.
    Lockout—They have a lockout to secure in the off position using a padlock (not included).
    Safety Interlock—Switches with safety interlock keep the door closed when the switch is on and prevent the switch from turning on when the door is open.
    Viewing Window—Switches with a viewing window let you see the switch position without opening the enclosure.
    NEMA 3R Enclosure Rating—A raintight NEMA 3R rated enclosure protects these switches from falling liquids and light splashing.
    Switches
    Rejection-Style Fuse Clips for
    RK1 and RK5 Fuse Class
    Switching
    Current,
    amp
    Voltage
    Switch
    Designation
    Electrical Phase (hp)
    For No.
    of Wires
    For Fuse UL Class
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Mil. Spec.
    Each
    Each
    Gray Enamel-Coated Steel with Black/Red Actuator
     
    3 Circuits Controlled with Lockout, Safety Interlock, and Viewing Window
    30600V AC/600V DC3PST
    Single (10 hp @ 240V AC)
    Three (30 hp @ 600V AC)
    315"7 3/4"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K910000000———0
    60600V AC/600V DC3PST
    Single (30 hp @ 240V AC)
    Three (60 hp @ 600V AC)
    318 1/2"9 1/16"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    7499K83000000———0
     
    3 Circuits Controlled with Lockout, Safety Interlock, Fuse Holder, and Viewing Window
    30600V AC/600V DC3PST
    Three (20 hp @ 600V AC)3RK1, RK5, J, H15"7 3/4"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K760000007499K111000000
    30600V AC/600V DC3PST
    Three (20 hp @ 600V AC)4RK1, RK5, J, H15"7 3/4"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K930000007499K11100000
    60600V AC/600V DC3PST
    Three (50 hp @ 600V AC)3RK1, RK5, J, H17 1/2"10 1/2"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    Fed. Spec. W-S-8657499K680000007499K11200000
    60600V AC/600V DC3PST
    Three (50 hp @ 600V AC)4RK1, RK5, J, H18 1/2"9 1/16"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    7499K740000007499K11200000
    100600V AC/600V DC3PST
    Three (100 hp @ 600V AC)4RK1, RK5, J, H22 1/8"9 1/16"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    7499K75000000007499K11300000
    200600V AC/600V DC3PST
    Three (150 hp @ 600V AC)4RK1, RK5, J, H29"17"3/8"TabNEMA 3R
    UL Listed, CSA Certified
    7499K77000000007499K11400000
     
    Gray Powder-Coated Steel Housing with Red Actuator
     
    2 Circuits Controlled with Lockout, Safety Interlock, and Fuse Holder
    100240V AC/250V DCDPST
    Single (15 hp @ 240V AC)3RK1, RK5, K5, T, H17 1/2"11 3/16"5/16"TabNEMA 3R
    UL Listed
    7524K260000007524K41300000
     
    2 Circuits Controlled with Lockout and Fuse Holder
    30240V AC/250V DCDPST
    Single (3 hp @ 240V AC)3RK1, RK5, K5, H8 9/16"5 7/16"5/16"TabNEMA 3R
    UL Listed
    7524K24000007524K411000000
    60240V AC/250V DCDPST
    Single (10 hp @ 240V AC)3RK1, RK5, K5, H10 1/16"6 7/16"5/16"TabNEMA 3R
    UL Listed
    7524K250000007524K41200000
     
    3 Circuits Controlled with Lockout and Safety Interlock
    100240V AC/250V DC3PST
    Three (30 hp @ 240V AC)317 1/2"11 3/16"5/16"TabNEMA 3R
    UL Listed
    7524K36000000———0
     
    3 Circuits Controlled with Lockout, Safety Interlock, and Fuse Holder
    100240V AC/250V DC3PST
    Single (15 hp @ 240V AC)
    Three (30 hp @ 240V AC)
    4RK1, RK5, K5, T, H23 1/8"11 3/4"5/16"TabNEMA 3R
    UL Listed
    7524K160000007524K41300000
     
    3 Circuits Controlled with Lockout and Fuse Holder
    30240V AC/250V DC3PST
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    4RK1, RK5, K5, H8 9/16"5 7/16"5/16"TabNEMA 3R
    UL Listed
    7524K140000007524K411000000
    60240V AC/250V DC3PST
    Single (10 hp @ 240V AC)
    Three (15 hp @ 240V AC)
    4RK1, RK5, K5, H10 1/16"6 7/16"5/16"TabNEMA 3R
    UL Listed
    7524K150000007524K41200000
     
    3 Circuits Controlled with Lockout
    30240V AC/250V DC3PST
    Three (7 1/2 hp @ 240V AC)36 3/8"4 9/16"5/16"TabNEMA 3R
    UL Listed
    7524K34000000———0
    60240V AC/250V DC3PST
    Three (15 hp @ 240V AC)38 9/16"5 7/16"5/16"TabNEMA 3R
    UL Listed
    7524K35000000———0
     
    Fuse Holders

    Manual Transfer Switches

    Image of Product. Front orientation. Transfer Switches. Manual Transfer Switches, NEMA 3R.

    NEMA 3R

    If there’s a power outage, flip the toggle for each circuit on these switches to backup power. Each circuit can also be turned off completely. To prevent injury and damage to your generators, they are open transition, meaning the contacts disconnect from one power source before connecting to another. This is also known as break-before-make switching.
    Use them with a portable generator.
    NEMA 3R—NEMA 3R switches can be used outdoors since they seal out rain, snow, and sleet.
    Key Lock—Switches with a key lock prevent unauthorized changes to the switch.
    Housing
    Mounting
    Max. Power,
    W
    Switching Current
    (No. of Switches)
    Circuit Breaker Breakthrough
    Current, amp
    Electrical
    Phase
    Housing Material
    Ht.
    Wd.
    Dp.
    Generator Connection
    NEMA Type
    Generator Connection
    California Std. Style
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Features
    Certification
    Specs. Met
    Each
    NEMA 3R
     
    10 Circuits Controlled
    7,50020 amp @ 240V AC (1 DPDT)
    20 amp @ 120V AC (2 SPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel12 3/4"12"5"L14-30
    Yes51/4"Key LockUL Listed
    UL 1008, NEC Article 7024272N140000000
    12,50020 amp @ 240V AC (1 DPDT)
    20 amp @ 120V AC (2 SPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel12 3/4"12"5"CS6375Yes51/4"Key LockUL Listed
    UL 1008, NEC Article 7024272N16000000
     

    Enclosure Motor Switches

    Image of Specification. Front orientation. Contains Annotated. Enclosure Motor Switches.
    Designed to mount on an electrical enclosure, these switches control motors, lighting, and electric heat circuits. Your enclosure door will only open when the switch is turned to the off position. This ensures equipment is safely off before you open the electrical enclosure. For an extra layer of safety, use a padlock (not included) on the actuator lever to lock switches in the off position. These switches do not provide overload protection.
    Cut the shaft to fit your enclosure. Mount to a DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Housing
    Material
    Ht.
    Wd.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Wire
    Connection
    Environment
    Enclosure
    Rating
    Certification
    Each
    Maintained
     
    Lever Actuator
    3Single (2 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    25600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N110000000
    3Single (2 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    32600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N12000000
    3Single (3 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    40600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N13000000
    3Three (10 hp @ 240V AC)
    Three (20 hp @ 480V AC)
    3 Off
    3PST-NO
    63600Plastic2.4"2.4"358 1/16" to 15 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N14000000
    3Three (15 hp @ 240V AC)
    Three (30 hp @ 480V AC)
    3 Off
    3PST-NO
    80600Plastic2.4"2.4"358 1/16" to 15 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N15000000
    3Three (25 hp @ 240V AC)
    Three (50 hp @ 480V AC)
    3 Off
    3PST-NO
    125600Plastic3.5"3.5"359 1/16" to 16 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N16000000
    3Three (30 hp @ 240V AC)
    Three (50 hp @ 480V AC)
    3 Off
    3PST-NO
    175600Plastic3.5"3.5"359 1/16" to 16 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N17000000
     

    Enclosed Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Enclosed Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Enclosed Disconnect Switches.

    Power Pole

    Neutral Pole

    Cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. These switches are housed in a protective enclosure that resists denting, chipping, and cracking. Mount them to the wall when you run out of space in an electrical panel.
    Use additional switch power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Two-Circuit Switch with Lockout. Front orientation. Disconnect Switches. Enclosed Disconnect Switches, Plastic Housing, 2 Circuits Controlled, Lockout.
    Image of Product. Three-Circuit Switch. Front orientation. Disconnect Switches. Enclosed Disconnect Switches, Plastic Housing, 3 Circuits Controlled.
    Image of Product. Three-Circuit Switch with Lockout. Front orientation. Disconnect Switches. Enclosed Disconnect Switches, Plastic Housing, 3 Circuits Controlled with Lockout.

    Two-Circuit

    Switch with

    Lockout

    Three-Circuit

    Switch

    Three-Circuit

    Switch with

    Lockout

    Lockout—Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
    Photovoltaic—Photovoltaic switches can be used with photovoltaic cells which convert sunlight into electricity.
    Switching
    Current,
    amp
    Voltage
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure Rating
    Certification
    Each
    Gray Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    50600V AC3PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    8 11/16"5 7/8"5/16"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K3130000000
    63600V AC3PST
    Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (10 hp @ 240V AC)
    8 11/16"5 7/8"5/16"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K314000000
    80600V AC3PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    8 11/16"5 7/8"5/16"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K315000000
    100600V AC3PST
    Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (25 hp @ 240V AC)
    8 11/16"5 7/8"5/16"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K316000000
     
    3 Circuits Controlled
    50600V AC3PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    8 11/16"5 7/8"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K333000000
    63600V AC3PST
    Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (10 hp @ 240V AC)
    8 11/16"5 7/8"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K334000000
    80600V AC3PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    8 11/16"5 7/8"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K335000000
    100600V AC3PST
    Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (25 hp @ 240V AC)
    8 11/16"5 7/8"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K336000000
     
    Gray Plastic Housing with Gray Actuator
     
    3 Circuits Controlled with Lockout
    50600V AC3PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    8 11/16"5 7/8"5/16"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K323000000
    63600V AC3PST
    Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (10 hp @ 240V AC)
    8 11/16"5 7/8"5/16"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K324000000
    80600V AC3PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    8 11/16"5 7/8"5/16"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K325000000
    100600V AC3PST
    Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (25 hp @ 240V AC)
    8 11/16"5 7/8"5/16"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K326000000
     
    3 Circuits Controlled
    50600V AC3PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    8 11/16"5 7/8"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K343000000
    63600V AC3PST
    Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (10 hp @ 240V AC)
    8 11/16"5 7/8"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K344000000
    80600V AC3PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    8 11/16"5 7/8"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K345000000
    100600V AC3PST
    Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (25 hp @ 240V AC)
    8 11/16"5 7/8"Screw TerminalIP40
    NEMA 3
    UL Listed, C-UL Listed, CE Marked
    6759K346000000
     
    Yellow Plastic Housing with Red Actuator
     
    2 Circuits Controlled with Lockout/Photovoltaic
    20800V DCDPST
    9 13/16"6 5/16"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K72000000
    32800V DCDPST
    11"7 1/2"5/16"Screw TerminalIP66
    IP67
    NEMA 3S
    NEMA 6P
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    6759K73000000
    50800V DCDPST
    12 5/8"8 11/16"5/16"Screw TerminalIP65
    NEMA 3R
    UL Listed, C-UL Listed, CE Marked
    6759K74000000
    63650V DCDPST
    12 5/8"8 11/16"5/16"Screw TerminalIP65
    NEMA 3R
    UL Listed, C-UL Listed, CE Marked
    6759K71000000
     
    Accessories and Replacements for Disconnect Switches

    Harsh Environment Panel-Mount Disconnect Switches

    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style B. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style A. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style C. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.

    Style B

    Style A

    Style C

    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP69K Enclosure Rating—Rated IP69K, these switches withstand high-pressure, high-temperature washdowns.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Dia.
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Yellow Stainless Steel Housing with Red Actuator
     
    2 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    A20300DPST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 15/16"2 15/16"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K1120000000
     
    3 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    B406003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K511000000
    B606003PST
    Single (3 hp @ 120V AC)
    Single (7 1/2 hp @ 240V AC)
    Three (15 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K521000000
     
    4 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    A203004PST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 15/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K115000000
     
    Gray Stainless Steel Housing with Gray Actuator
     
    2 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    C20300DPST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 1/8"2 3/4"2 15/16"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K113000000
     
    3 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    B406003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K512000000
    B606003PST
    Single (3 hp @ 120V AC)
    Single (7 1/2 hp @ 240V AC)
    Three (15 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K522000000
     
    4 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    C203004PST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 1/8"2 3/4"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K116000000
     
    Labels

    Panel-Mount Compact Disconnect Switches

    Install these switches in a panel cutout. Small enough to fit in tight spaces, they handle comparable electrical loads to standard sized switches. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Panel-Mount Compact Disconnect Switches.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP65 Enclosure Rating—They’re rated IP65 for protection from washdowns.
    Switching Current @ Voltage
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Gray Plastic Housing with Black Actuator
     
    3 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC3PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K101000000
    16 amp @ 600V AC, 20 amp @ 24V DC3PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10200000
    20 amp @ 600V AC, 25 amp @ 24V DC3PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10300000
    25 amp @ 600V AC, 32 amp @ 24V DC3PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K104000000
    50 amp @ 600V AC, 50 amp @ 24V DC3PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K105000000
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K106000000
     
    4 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC4PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10700000
    16 amp @ 600V AC, 20 amp @ 24V DC4PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10800000
    20 amp @ 600V AC, 25 amp @ 24V DC4PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10900000
    25 amp @ 600V AC, 32 amp @ 24V DC4PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K111000000
    50 amp @ 600V AC, 50 amp @ 24V DC4PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K112000000
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K113000000
     
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC3PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K1100000
    16 amp @ 600V AC, 20 amp @ 24V DC3PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K1200000
    20 amp @ 600V AC, 25 amp @ 24V DC3PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K1300000
    25 amp @ 600V AC, 32 amp @ 24V DC3PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K14000000
    50 amp @ 600V AC, 50 amp @ 24V DC3PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K15000000
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K16000000
     
    4 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC4PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4100000
    16 amp @ 600V AC, 20 amp @ 24V DC4PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4200000
    20 amp @ 600V AC, 25 amp @ 24V DC4PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4300000
    25 amp @ 600V AC, 32 amp @ 24V DC4PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K44000000
    50 amp @ 600V AC, 50 amp @ 24V DC4PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K45000000
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K46000000
     

    Washdown Enclosed Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches.

    Power Pole

    Neutral Pole

    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Use additional switch power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Switch with Plastic Housing. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches, Plastic Housing.
    Image of Product. Switch with Lockout and Plastic Housing. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches, Plastic Housing, 3 Circuits Controlled with Lockout.
    Image of Product. Switch with Lockout and Stainless Steel Housing. Front orientation. Disconnect Switches. Washdown Enclosed Disconnect Switches, Stainless Steel Housing, 3 Circuits Controlled with Lockout.

    Switch with

    Plastic Housing

    Switch with

    Lockout and

    Plastic Housing

    Switch with Lockout

    and Stainless Steel

    Housing

    Lockout—Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
    IP66 Enclosure Rating—The IP66 rated housing not only shields these switches from washdowns but also makes them durable enough to be mounted outside of an electrical panel.
    Switching
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Gray Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    206003PST
    Single (1/3 hp @ 120V AC)
    Single (3/4 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    6 7/8"4 1/2"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K11000000
    406003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    6 7/8"4 1/2"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K1200000
    636003PST
    Single (3 hp @ 120V AC)
    Single (7 1/2 hp @ 240V AC)
    Three (15 hp @ 240V AC)
    11"7 1/2"3/8"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K13000000
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    11"7 1/2"3/8"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K14000000
    1006003PST
    Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (25 hp @ 240V AC)
    11"7 1/2"3/8"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K15000000
     
    3 Circuits Controlled
    256003PST
    Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    5 7/8"4 5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K33100000
    326003PST
    Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    5 7/8"4 5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K33200000
     
    Gray Plastic Housing with Gray Actuator
     
    3 Circuits Controlled with Lockout
    256003PST
    Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    5 7/8"3 7/8"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K32100000
    326003PST
    Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    5 7/8"3 7/8"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K32200000
     
    3 Circuits Controlled
    256003PST
    Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    5 7/8"4 5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K34100000
    326003PST
    Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    5 7/8"4 5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K34200000
     
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    256003PST
    Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (3 hp @ 240V AC)
    5 7/8"3 7/8"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K31100000
    326003PST
    Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    5 7/8"3 7/8"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K31200000
     
    Stainless Steel Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    206003PST
    Single (1/3 hp @ 120V AC)
    Single (1 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    7 7/8"5 15/16"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K6000000
    306003PST
    Single (1 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (5 hp @ 240V AC)
    7 7/8"5 15/16"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K61000000
    406003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    7 7/8"5 15/16"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K62000000
    606003PST
    Single (3 hp @ 120V AC)
    Single (7 1/2 hp @ 240V AC)
    Three (15 hp @ 240V AC)
    7 7/8"5 15/16"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K63000000
    806003PST
    Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (20 hp @ 240V AC)
    7 7/8"5 15/16"5/16"Screw TerminalIP66
    UL Listed, C-UL Listed, CE Marked
    6759K64000000
     
    Accessories and Replacements for Disconnect Switches

    Hazardous Location Enclosed Disconnect Switches

    Image of Product. Style A. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style A.
    Image of Product. Style B. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style B.

    Style A

    Style B

    With a housing that’s designed to contain an explosion, these switches are safe to use in areas where ignitable concentrations of flammable or combustible gas, dust, or fibers may be present. Use them to cut power and keep it isolated, so equipment won’t accidentally start up during inspection or maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style A. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style A.
    Image of Product. Style B. Front orientation. Disconnect Switches. Hazardous Location Enclosed Disconnect Switches, Powder-Coated Aluminum Housing, 3 Circuits Controlled with Lockout, Style B.

    Style A

    Style B

    Powder-Coated Aluminum Housing—Made from aluminum, these switches also resist corrosion in wet or oily areas.
    Lockout—Switches have a lockout, so you can secure them in the off position with a padlock (not included).
    Hazardous Location Rating—They meet NEC Class I Div. 1 and 2, Groups B, C, D, and Class II, Div. 1 and 2, Groups E, F, and G.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Hazardous Location Rating
    Enclosure Rating
    Certification
    Each
    Gray Powder-Coated Aluminum Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    A306003PST
    Three (30 hp @ 600V AC)8 1/16"5 3/4"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N11000000000
     
    Gray Powder-Coated Aluminum Housing with Yellow Actuator
     
    3 Circuits Controlled with Lockout
    B606003PST
    Three (40 hp @ 600V AC)13 1/16"8 1/8"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N1200000000
    B1006003PST
    Three (50 hp @ 600V AC)13 1/16"8 1/8"5/16"Screw TerminalNEC Class I Divisions 1, 2 Groups B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Zone 1 Groups IIB, IIA
    NEMA 4X
    NEMA 7
    NEMA 9
    CSA Certified, CSA-US Certified
    7857N1300000000
     

    Enclosed Compact Disconnect Switches

    Small yet mighty, these switches are about as tall and wide as an index card yet durable enough to mount directly to a wall. Don’t be fooled by their size—these switches can handle electrical loads comparable to a standard sized switch.
    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Enclosed Compact Disconnect Switches.
    Plastic Housing—Their plastic housing protects the switch and resists denting, chipping, and cracking.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP65 Enclosure Rating—Rated IP65, the housing also seals out water even in frequently washed down areas.
    Switching Current @ Voltage
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    12 amp @ 600V AC, 16 amp @ 24V DC3PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K210000000
    16 amp @ 600V AC, 20 amp @ 24V DC3PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K22000000
    20 amp @ 600V AC, 25 amp @ 24V DC3PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K23000000
    25 amp @ 600V AC, 32 amp @ 24V DC3PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K24000000
    50 amp @ 600V AC, 50 amp @ 24V DC3PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K25000000
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K26000000
     
    4 Circuits Controlled with Lockout
    12 amp @ 600V AC, 16 amp @ 24V DC4PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K34000000
    16 amp @ 600V AC, 20 amp @ 24V DC4PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K35000000
    20 amp @ 600V AC, 25 amp @ 24V DC4PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K36000000
    25 amp @ 600V AC, 32 amp @ 24V DC4PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K37000000
    50 amp @ 600V AC, 50 amp @ 24V DC4PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K38000000
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K39000000
     

    Manual Override Enclosure Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Manual Override Enclosure Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Manual Override Enclosure Disconnect Switches.
    Image of Product. Front orientation. Contains Annotated. Disconnect Switches. Manual Override Enclosure Disconnect Switches.

    Power Pole

    Neutral Pole

    Keep power running while you access your enclosure. Unlike standard enclosure disconnect switches, which shut off power as you open your enclosure, these have an override function. Engaging the override allows you to take voltage reading, troubleshoot an error code, or fine tune the speed of your line. Cut the shaft to fit your enclosure.
    Use additional switch power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    Safety Interlock—When the override is off, these work like a standard disconnect switch—a safety interlock prevents your enclosure from opening when power is on. The interlock also prevents the switch from turning on when the door is already open.
    Switching
    Current,
    amp
    Voltage,
    V AC
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Enclosure Rating
    Certification
    Each
    Black Plastic Housing with Black Actuator
     
    3 Circuits Controlled with Lockout and Safety Interlock—For 1 1/2" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N170000000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N18000000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N19000000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N21000000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N22000000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N23000000
     
    Black Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout and Safety Interlock—For 1 1/2" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N11000000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N12000000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N13000000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N14000000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N15000000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N16000000
     
    Accessories and Replacements for Disconnect Switches
    back to top