About Metal Tubing
More
About Conduit
More
Precision Stainless Steel Tubing
This tubing is made to tighter tolerances than other stainless steel tubing. It is welded with a smoothed weld bead on the inside to reduce particle buildup. Tubing connects by welding.
304 stainless steel has very good corrosion resistance.
316 stainless steel offers excellent corrosion resistance.
For technical drawings and 3-D models, click on a part number.
- Temperature Range: -420° to 600° F
- Bending Method: Tube Bender
OD | OD Tolerance | Wall Thick. | ID | Max. Pressure | Temper Rating | 1 ft. Lg. | 3 ft. Lg. | |
304 Stainless Steel—For Use With Air, Hydraulic Fluid, Natural Gas, Oil, Water | ||||||||
---|---|---|---|---|---|---|---|---|
0.25" | -0.002" to 0.004" | 0.005" | 0.24" | 3,500 psi @ 72° F | Hard | 00000000 | ||
316 Stainless Steel—For Use With Air, Hydraulic Fluid, Natural Gas, Oil, Water | ||||||||
0.25" | -0.002" to 0.004" | 0.005" | 0.24" | 3,500 psi @ 72° F | Hard | 00000000 |
Flexible Metal Conduit for Fiber Optic Cable
Protect fiber optic cable with this small-diameter conduit. Made of 304 stainless steel, it’s flexible enough to weave through tight spaces but strong enough to resist over-bending, so it won’t disrupt signals. Rated IP68, it’s dust tight and protected from prolonged submersion.
Conduit with a PVC cover is stretch resistant to protect cable from damage during installation. It also resists compression and impact for use in tight spaces that may shift over time, and resists UV light for use outdoors. This conduit does not resist oil or chemicals as well as conduit with a silicone cover.
Conduit with a silicone cover won’t absorb oil or chemicals, including the hazardous pulling lubricants commonly used in cable installation. Fiberglass braiding inside this conduit makes it stretch resistant, protecting cable while it’s being installed. The braiding limits conduit flexibility, giving it a wider bend radius than conduit with a PVC cover to provide cable with extra protection from over-bending. This conduit stays flexible at high temperatures, so it’s a common choice for guarding fiber optic cable near heat sources. It’s not as compression or impact resistant as conduit with a PVC cover.
Conduit Trade Size | ID | OD | Bend Radius | Internal Reinforcement | Color | Temperature Range, °F | Environment | Environmental Rating | Lengths, ft. | Per Ft. | |
304 Stainless Steel | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
PVC Plastic Cover | |||||||||||
1/4 | 0.24" | 0.35" | 2" | __ | Black | -10° to 190° | Dusty, Submersible | IP68 | 0000000 | 00000 | |
Silicone Rubber Cover | |||||||||||
1/4 | 0.24" | 0.35" | 3" | Fiberglass Braid | Gray | -50° to 350° | Dusty, Submersible | IP68 | 0000000 | 00000 |
Continuous-Flex Plastic Conduit
For technical drawings and 3-D models, click on a part number.
In addition to continuous-motion applications such as robotics, this conduit is suitable for high-vibration applications. Also known as mechanical protection tubing (MPT), it resists solvents, fuels, hydraulic and lubricating oils, and UV light.
Tabs on one end snap into grooves in continuous-flex plastic conduit; the other end attaches to a knockout in an outlet box or enclosure. These fittings resist solvents, fuels, hydraulic and lubricating oils, and UV light. Fittings meet IP66 for protection from dust and water jets.
Conduit Connection | Electrical Box Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Conduit OD | Gender | OD | Thread Size | Gender | Material | Color | Temperature Range, °F | Environment | Environmental Rating | Specifications Met | Each | |
Snap-In Conduit Connection × PG Threaded Electrical Box Connection | ||||||||||||
0.39" | Female | 0.91" | PG-11 | Male | Nylon | Black | -40° to 220° | Washdown | IP66 | UL Recognized Component | 00000000 | 00000 |
Tabs on one end snap into grooves in continuous-flex plastic conduit; the other end attaches to a knockout in an outlet box or enclosure. These fittings resist solvents, fuels, hydraulic and lubricating oils, and UV light. Fittings meet IP66 for protection from dust and water jets.
Conduit Connection | Electrical Box Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Conduit OD | Gender | OD | Thread Size | Gender | Material | Color | Temperature Range, °F | Environment | Environmental Rating | Specifications Met | Each | |
Snap-In Conduit Connection × PG Threaded Electrical Box Connection | ||||||||||||
0.39" | Female | 0.91" | PG-11 | Male | Nylon | Black | -40° to 220° | Washdown | IP66 | UL Recognized Component, CSA Certified, CE Marked | 00000000 | 000000 |
Liquid-Tight Sealing Grommets
Rated IP68, these grommets form liquid-tight seals around wire, cable, and cords to protect them against dust as well as submersion in a maximum of one meter of water. They’re often used in lighting cable applications. Made of rubber, all of these grommets have a flange to securely fasten them to surfaces with screws.
Grommets for outdoor use are commonly used in marine and antenna cable applications.
For technical drawings and 3-D models, click on a part number.
For OD | ID (C) | Flange Dia. (D) | Overall Ht. (E) | Temp. Range, °F | For Use Outdoors | Mounting Fasteners Included | Environmental Rating | Color | Each | |
Rubber with Black Plastic Flange | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
0.08"-0.23" | 0.24" | 1.18" | 0.67" | 20° to 120° | Yes | Yes | IP68 | Black | 00000000 | 000000 |
Rubber with Gray Plastic Flange | ||||||||||
0.08"-0.23" | 0.24" | 1.18" | 0.67" | 20° to 120° | Yes | Yes | IP68 | Black | 00000000 | 00000 |