Thermocouple Connectors




Add these connectors to thermocouple wire for easy attachment to thermometers and control panels.
Connectors with exposed screw terminals let you quickly attach wire leads without disassembling the connectors.
For technical drawings and 3-D models, click on a part number.
Material | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | No. of Connections | For Max. Wire Gauge | Max. Temperature, ° F | Color | Pin Lg. | Distance Between Pins | Body | Contact | Each | |
Flat-Pin Male Connector | ||||||||||
Screw Terminals | ||||||||||
T | 1 | 24 | 400° | Blue | 1/2" | 0.313" | Plastic | Copper | 0000000 | 00000 |
T | 1 | 24 | 800° | Red | 1/2" | 0.313" | Plastic | Copper | 0000000 | 0000 |
Flat-Pin Female Connector | ||||||||||
Screw Terminals | ||||||||||
T | 1 | 24 | 400° | Blue | __ | 0.313" | Plastic | Copper | 0000000 | 0000 |
T | 1 | 24 | 800° | Red | __ | 0.313" | Plastic | Copper | 0000000 | 0000 |
Round-Pin Male Connector | ||||||||||
Screw Terminals | ||||||||||
T | 1 | 14 | 400° | Blue | 9/16" | 0.438" | Plastic | Copper | 0000000 | 0000 |
T | 1 | 14 | 800° | Red | 9/16" | 0.438" | Plastic | Copper | 0000000 | 00000 |
Exposed Screw Terminals | ||||||||||
T | 1 | 14 | 400° | Blue | 9/16" | 0.438" | Plastic | Copper | 0000000 | 0000 |
T | 1 | 14 | 800° | Red | 9/16" | 0.438" | Plastic | Copper | 0000000 | 00000 |
T | 1 | 14 | 1000° | White | 1/2" | 0.442" | Ceramic | Copper | 0000000 | 0000 |
Round-Pin Female Connector | ||||||||||
Screw Terminals | ||||||||||
T | 1 | 14 | 400° | Blue | __ | 0.438" | Plastic | Copper | 0000000 | 0000 |
T | 1 | 14 | 800° | Red | __ | 0.438" | Plastic | Copper | 0000000 | 00000 |
Exposed Screw Terminals | ||||||||||
T | 1 | 14 | 400° | Blue | __ | 0.438" | Plastic | Copper | 0000000 | 0000 |
T | 1 | 14 | 800° | Red | __ | 0.438" | Plastic | Copper | 0000000 | 00000 |
T | 1 | 14 | 1000° | White | __ | 0.442" | Ceramic | Copper | 0000000 | 0000 |
Panel-Mount Thermocouple Connection Strips


Connect multiple thermocouple probes to an instrument panel.
For technical drawings and 3-D models, click on a part number.
For Panel Cutout | Material | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | No. of Connections | For Max. Wire Gauge | Max. Temperature, ° F | Wd. | Ht. | Color | Body | Contact | Fasteners Included | Each | |
Flat-Pin Female Connector | |||||||||||
Screw Terminals | |||||||||||
T | 2 | 24 | 400° | 1 1/4" | 1" | Blue | Plastic | Copper | Yes | 0000000 | 000000 |
T | 4 | 24 | 400° | 2 5/8" | 1" | Blue | Plastic | Copper | Yes | 0000000 | 00000 |
T | 6 | 24 | 400° | 4" | 1" | Blue | Plastic | Copper | Yes | 0000000 | 00000 |
T | 8 | 24 | 400° | 5 3/8" | 1" | Blue | Plastic | Copper | Yes | 0000000 | 00000 |
Round-Pin Female Connector | |||||||||||
Screw Terminals | |||||||||||
T | 2 | 16 | 400° | 1 5/16" | 1 1/4" | Blue | Plastic | Copper | Yes | 0000000 | 00000 |
T | 4 | 16 | 400° | 2 13/16" | 1 1/4" | Blue | Plastic | Copper | Yes | 0000000 | 00000 |
T | 6 | 16 | 400° | 4 5/16" | 1 1/4" | Blue | Plastic | Copper | Yes | 0000000 | 00000 |
T | 8 | 16 | 400° | 5 13/16" | 1 1/4" | Blue | Plastic | Copper | Yes | 0000000 | 00000 |
Panel-Mount Thermocouple Connectors


Plug thermocouple probes into a control panel.
For technical drawings and 3-D models, click on a part number.
Material | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | No. of Connections | For Max. Wire Gauge | Max. Temperature, ° F | For Panel Cutout Dia. | Color | Body | Contact | Fasteners Included | Each | |
Flat-Pin Female Connector | ||||||||||
Screw Terminals | ||||||||||
T | 1 | 20 | 400° | 7/8" | Blue | Plastic | Copper | Yes | 0000000 | 000000 |
Round-Pin Female Connector | ||||||||||
Screw Terminals | ||||||||||
T | 1 | 14 | 400° | 1 1/8" | Blue | Plastic | Copper | Yes | 0000000 | 00000 |
Thermocouple Extension Wire with Connectors





Extend the reach of your thermocouple probe—plug-in connectors on both ends of this wire speed up installation.
Stranded wire is more flexible than solid wire.
Wire | Material | ||||||||
---|---|---|---|---|---|---|---|---|---|
Thermocouple Type | Temperature Range, ° F | Lg., ft. | Gauge | Dia. | Insulation | Jacket | Max. Jacket Temperature, ° F | Each | |
Solid Wire | |||||||||
Flat-Pin Male × Flat-Pin Female Connector | |||||||||
T | -15° to 220° | 10 | 24 | 0.17" | PVC | PVC | 220° | 00000000 | 000000 |
T | -15° to 220° | 25 | 24 | 0.17" | PVC | PVC | 220° | 00000000 | 00000 |
T | -15° to 220° | 50 | 24 | 0.17" | PVC | PVC | 220° | 00000000 | 00000 |
Flat-Pin Male × Flat-Pin Male Connector | |||||||||
T | -15° to 220° | 10 | 24 | 0.17" | PVC | PVC | 220° | 0000000 | 00000 |
T | -15° to 220° | 25 | 24 | 0.17" | PVC | PVC | 220° | 0000000 | 00000 |
T | -15° to 220° | 50 | 24 | 0.17" | PVC | PVC | 220° | 0000000 | 00000 |
Round-Pin Male × Round-Pin Female Connector | |||||||||
T | -15° to 220° | 10 | 24 | 0.17" | PVC | PVC | 220° | 00000000 | 00000 |
T | -15° to 220° | 25 | 24 | 0.17" | PVC | PVC | 220° | 00000000 | 00000 |
T | -15° to 220° | 50 | 24 | 0.17" | PVC | PVC | 220° | 00000000 | 00000 |
Stranded Wire | |||||||||
Flat-Pin Male × Flat-Pin Female Connector | |||||||||
T | -30° to 220° | 5 | 28 | 0.165" | PTFE | Polyurethane | 220° | 00000000 | 00000 |
Flat-Pin Male × Flat-Pin Male Connector | |||||||||
T | -30° to 220° | 5 | 28 | 0.165" | PTFE | Polyurethane | 220° | 0000000 | 00000 |