Sensing Distance | Accuracy | Output Data Freq., Hz | Measures | Temp. Range, ° F | Input Voltage, V DC | Connection Method | Lg. | Wd. | Ht. | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 cm to 4 m | ±0.3 cm | 40 | Distance | 32 to 100 | 5 | Push In, Solder | 1 3/4" | 3/4" | 1/2" | 7132N13 | 00000 | ||
Infrared LED Modules
Output Data | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensing Distance | Sensing Distance Resolution, cm | Accuracy | Resolution, bit | Freq., Hz | Measures | Temp. Range, ° F | Input Voltage, V DC | I2C Address | Connection Method | No. of Qwiic Connections | Lg. | Wd. | Ht. | Each | |||
I²C Communication Protocol—Qwiic Connection | |||||||||||||||||
| 5 cm to 10 m | 1 | ±1 cm | 7 | 200 | Distance | 0 to 140 | 3.3 | 0x62 | Solder | 2 | 2 5/16" | 1" | 7/8" | 7132N12 | 0000000 | ||
Ultrasonic Transmitters
Straight
Sensors | Cables with Socket | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outputs | Signal Output | Output Analog Signal | Sensing Distance | Input Voltage, V DC | Control Communication Protocol | Dia., mm | Lg., mm | Housing Material | Circuit Protection | Temp. Range, ° F | Enclosure Rating | Each | Each | ||||
With 4-Pole M12 Plug-In Connection | |||||||||||||||||
Analog | |||||||||||||||||
| 1 | — | 4 mA to 20 mA | 40 mm to 300 mm | 10 to 30 | — | 18 | 61 | Stainless Steel | Overload, Reverse Polarity, Short Circuit | 0 to 155 | IP67 | 7635N15 | 0000000 | 6897K36 | 000000 | ||
| 1 | — | 4 mA to 20 mA | 80 mm to 1.2 m | 10 to 30 | — | 18 | 61 | Stainless Steel | Overload, Reverse Polarity, Short Circuit | 0 to 155 | IP67 | 7635N16 | 000000 | 6897K36 | 00000 | ||
Digital/Analog | |||||||||||||||||
| 2 | PNP | 4 mA to 20 mA | 150 mm to 1.6 m | 10 to 30 | IO-Link | 18 | 98 | Stainless Steel | Overload, Reverse Polarity, Short Circuit | 0 to 155 | IP67 | 7635N17 | 000000 | 6897K36 | 00000 | ||
| 2 | PNP | 4 mA to 20 mA | 250 mm to 3.5 m | 10 to 30 | IO-Link | 30 | 103 | Stainless Steel | Overload, Reverse Polarity, Short Circuit | 0 to 155 | IP67 | 7635N18 | 000000 | 6897K36 | 00000 | ||
90° Elbow
Sensors | Cables with Socket | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outputs | Signal Output | Output Analog Signal | Sensing Distance | Input Voltage, V DC | Dia., mm | Lg., mm | Wd., mm | Ht., mm | Housing Material | Circuit Protection | Temp. Range, ° F | Enclosure Rating | Each | Each | ||||
With 4-Pole M12 Plug-In Connection | ||||||||||||||||||
Analog | ||||||||||||||||||
| 1 | — | 4 mA to 20 mA | 100 mm to 1 m | 10 to 30 | 30 | 45 | 40 | 64 | Plastic | Overload, Reverse Polarity, Short Circuit | -40 to 155 | IP67, NEMA 6 | 6565K32 | 0000000 | 6897K36 | 000000 | ||
| 1 | — | 4 mA to 20 mA | 200 mm to 2 m | 10 to 30 | 30 | 45 | 40 | 64 | Plastic | Overload, Reverse Polarity, Short Circuit | -40 to 155 | IP67, NEMA 6 | 6565K44 | 000000 | 6897K36 | 00000 | ||
| 1 | — | 0V DC to 10V DC | 100 mm to 1 m | 10 to 30 | 30 | 45 | 40 | 64 | Plastic | Overload, Reverse Polarity, Short Circuit | -40 to 155 | IP67, NEMA 6 | 6565K92 | 000000 | 6897K36 | 00000 | ||
| 1 | — | 0V DC to 10V DC | 300 mm to 3 m | 10 to 30 | 30 | 45 | 40 | 64 | Plastic | Overload, Reverse Polarity, Short Circuit | -40 to 155 | IP67, NEMA 6 | 6565K94 | 000000 | 6897K36 | 00000 | ||
Digital/Analog | ||||||||||||||||||
| 2 | PNP | 4 mA to 20 mA | 40 mm to 300 mm | 10 to 30 | 18 | 38 | 20 | 53 | Plastic | Overload, Reverse Polarity, Short Circuit | 0 to 155 | IP67 | 7635N11 | 000000 | 6897K36 | 00000 | ||
| 2 | PNP | 4 mA to 20 mA | 80 mm to 1.2 m | 10 to 30 | 18 | 38 | 20 | 53 | Plastic | Overload, Reverse Polarity, Short Circuit | 0 to 155 | IP67 | 7635N12 | 000000 | 6897K36 | 00000 | ||
| 2 | PNP | 0V DC to 10V DC | 40 mm to 300 mm | 10 to 30 | 18 | 38 | 20 | 53 | Plastic | Overload, Reverse Polarity, Short Circuit | 0 to 155 | IP67 | 7635N13 | 000000 | 6897K36 | 00000 | ||
| 2 | PNP | 0V DC to 10V DC | 80 mm to 1.2 m | 10 to 30 | 18 | 38 | 20 | 53 | Plastic | Overload, Reverse Polarity, Short Circuit | 0 to 155 | IP67 | 7635N14 | 000000 | 6897K36 | 00000 | ||
Noncontact Liquid-Level Transmitters
Ultrasonic
Overall | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | For Liquid Level | Max. Pressure @ Temp. | Dia. | Lg. | Temp. Range, ° F | Cable Lg., ft. | Input Voltage, V DC | Electrical Connection | Enclosure Rating | Includes | Features | Each | |||
NPT Male Pipe Connection | |||||||||||||||
0-5V DC, 0-10V DC Signal | |||||||||||||||
| 1 | 0 ft. to 4 ft. | 30 psi @ 70° F | 2" | 3 1/4" | -30 to 140 | 4 | 12 to 24 | Wire Leads | NEMA 6P | USB Configuration Fob | — | 3407K23 | 0000000 | ||
4-20 mA Signal | |||||||||||||||
| 2 | 0 ft. to 19 1/2 ft. | 30 psi @ 70° F | 4 3/8" | 7" | -30 to 140 | — | 14 to 28 | Quick-Disconnect Terminal | IP68, NEMA 6P | USB Configuration Fob | Button Interface | 3407K17 | 000000 | ||
| 3 | 0 ft. to 39 ft. | 30 psi @ 70° F | 4 5/8" | 7" | -30 to 140 | — | 14 to 28 | Quick-Disconnect Terminal | IP68, NEMA 6P | USB Configuration Fob | Button Interface | 3407K18 | 00000000 | ||
4-20 mA Signal with Switch | |||||||||||||||
| 1 | 0 ft. to 4 ft. | 30 psi @ 70° F | 2" | 3 1/4" | -30 to 140 | 4 | 24 | Wire Leads | NEMA 6P | USB Configuration Fob | — | 3407K11 | 000000 | ||
| 1 | 0 ft. to 9 3/4 ft. | 30 psi @ 70° F | 3" | 4 3/4" | -30 to 140 | 4 | 24 | Wire Leads | NEMA 6P | USB Configuration Fob | — | 3407K14 | 000000 | ||
| 2 | 1 1/2" to 4 3/4 ft. | 30 psi @ 70° F | 2 3/4" | 4" | -30 to 140 | 4 | 14 to 28 | Wire Leads | IP68, NEMA 6P | USB Configuration Fob | — | 3407K15 | 000000 | ||
| 2 | 4" to 9 3/4 ft. | 30 psi @ 70° F | 2 3/4" | 4" | -30 to 140 | 4 | 14 to 28 | Wire Leads | IP68, NEMA 6P | USB Configuration Fob | — | 3407K16 | 000000 | ||
Ultrasonic Switches
Straight
Sensors | Cables with Socket | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outputs | Output Digital Signal | Sensing Distance | Input Voltage, V DC | Control Communication Protocol | Dia., mm | Lg., mm | Circuit Protection | Temp. Range, ° F | Enclosure Rating | Each | Each | ||||
Stainless Steel Housing | |||||||||||||||
With 4-Pole M12 Plug-In Connection | |||||||||||||||
| 1 | PNP | 40 mm to 300 mm | 10 to 30 | IO-Link | 18 | 61 | Overload, Reverse Polarity, Short Circuit | 0 to 155 | IP67 | 8058N13 | 0000000 | 6897K36 | 000000 | ||
| 2 | PNP | 150 mm to 1.6 m | 10 to 30 | IO-Link | 18 | 98 | Overload, Reverse Polarity, Short Circuit | 0 to 155 | IP67 | 8058N14 | 000000 | 6897K36 | 00000 | ||
| 2 | PNP | 250 mm to 3.5 m | 10 to 30 | IO-Link | 30 | 103 | Overload, Reverse Polarity, Short Circuit | 0 to 155 | IP67 | 8058N15 | 000000 | 6897K36 | 00000 | ||
90° Elbow
Sensors | Cables with Socket | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outputs | Output Digital Signal | Sensing Distance | Input Voltage, V DC | Control Communication Protocol | Dia., mm | Lg., mm | Wd., mm | Ht., mm | Circuit Protection | Temp. Range, ° F | Enclosure Rating | Each | Each | ||||
Plastic Housing | |||||||||||||||||
With 4-Pole M12 Plug-In Connection | |||||||||||||||||
| 1 | PNP | 40 mm to 300 mm | 10 to 30 | IO-Link | 18 | 38 | 20 | 53 | Overload, Reverse Polarity, Short Circuit | 0 to 155 | IP67 | 8058N11 | 0000000 | 6897K36 | 000000 | ||
| 1 | PNP | 80 mm to 1.2 m | 10 to 30 | IO-Link | 18 | 38 | 20 | 53 | Overload, Reverse Polarity, Short Circuit | 0 to 155 | IP67 | 8058N12 | 000000 | 6897K36 | 00000 | ||
| 1 | PNP/NPN | 100 mm to 1 m | 10 to 30 | — | 30 | 45 | 40 | 64 | Overload, Reverse Polarity, Short Circuit | -40 to 155 | IP67, NEMA 6 | 6565K65 | 000000 | 6897K36 | 00000 | ||
| 1 | PNP/NPN | 200 mm to 2 m | 10 to 30 | — | 30 | 45 | 40 | 64 | Overload, Reverse Polarity, Short Circuit | -40 to 155 | IP67, NEMA 6 | 6565K66 | 000000 | 6897K36 | 00000 | ||
| 1 | PNP/NPN | 300 mm to 3 m | 10 to 30 | — | 30 | 45 | 40 | 64 | Overload, Reverse Polarity, Short Circuit | -40 to 155 | IP67, NEMA 6 | 6565K95 | 000000 | 6897K36 | 00000 | ||
Ultrasonic Noncontact Level Sensor Switches for Chemicals
Pipe | Conduit | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Size | Thread Type | Gender | Sensing Distance, ft. | Max. Pressure @ Temp. | Temp. Range, ° F | Switch Starting Position | Switch Designation | Current @ Voltage | Lg. | Wd. | Electrical Connection | Enclosure Rating | Trade Size | Thread Type | Gender | Each | |||
95V AC to 250V AC Input Voltage | |||||||||||||||||||
Polycarbonate Body | |||||||||||||||||||
| 1 | NPT | Male | 0.33 to 9.8 | 30 psi @ 70° F | -5 to 140 | 1 Off or 1 On | SPDT | 0.17 amp @ 120V AC | 3 15/16" | 5 3/16" | Screw Terminal | IP65, NEMA 4X | 1/2 | NPT | Female | 3785K13 | 000000000 | ||