McMaster-Carr logo
    Filter by
    Connection Location
    System of Measurement
    Pipe Size
    Industrial Info Compare
    Scale Type
    Thread Type
    Fitting Connection
    Industrial Info Compare
    Display Type
    Accuracy Scale
    Maximum Continuous Pressure
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    76 Products
    About Pressure Gauges
    industrial info icon

    Find a gauge with the right connection material and dial type—many with traceable calibration certificates.

    Vacuum Gauges

    Use these gauges with vacuum pumps, packaging equipment, and in suction lines to measure and display vacuum.
    Painted Steel Case with Brass Connection—Single Scale (Inches of Mercury)
    Image of Product. Front orientation. Vacuum Gauges. Vacuum Gauges, Single Scale, Bottom Connection.
    Image of Product. Front orientation. Vacuum Gauges. Vacuum Gauges, Single Scale, Center-Back Connection.
    Image of Attribute. Bottom Connection. Front orientation. Vacuum Gauges, Bottom Connection.
    Image of Attribute. Center Back Connection. Front orientation. Vacuum Gauges, Center-Back Connection.

    Bottom

    Connection

    Center-Back

    Connection

    Bottom

    Connection

    Center Back

    Connection

    Gauges with a steel case are more impact resistant than gauges with an ABS case.
    Available Vacuum
    Ranges, in. Hg
    Bottom
    Connection
    Center-Back
    Connection
    Dial
    Dia.
    Pipe
    Size
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Case
    Color
    Vacuum
    Range
    Graduations
    Pressure Numeric
    Increments
    For Use
    With
    Accuracy
    Each
    Each
    NPT Male with Calibration Certificate Traceable to NIST
    1 1/2"1/8
    -40 to 150-40 to 150Black-30 to 00.55Air±2% Midscale (Grade B)4002K1380000004002K137000000
    2"1/4
    -40 to 150-40 to 150Black-30 to 00.55Air±2% Midscale (Grade B)4002K136000004002K12700000
    2 1/2"1/8
    -40 to 150-40 to 150Black-30 to 00.55Air±2% Midscale (Grade B)4002K16300000———0
    2 1/2"1/4
    -40 to 150-40 to 150Black-30 to 00.55Air±2% Midscale (Grade B)4002K128000004002K12900000
    3 1/2"1/4
    -40 to 150-40 to 150Black-30 to 00.55Air±2% Midscale (Grade B)4002K13200000———0
    4 1/2"1/4
    -40 to 150-40 to 150Black-30 to 00.55Air±2% Midscale (Grade B)4002K13300000———0
     
    Painted Steel Case with Brass Connection—Dual Scale (Inches of Mercury, Kilopascals)
    Image of Product. Front orientation. Vacuum Gauges. Vacuum Gauges, Dual Scale, Bottom Connection.
    Image of Product. Front orientation. Vacuum Gauges. Vacuum Gauges, Dual Scale, Center-Back Connection.
    Image of Attribute. Bottom Connection. Front orientation. Vacuum Gauges, Bottom Connection.
    Image of Attribute. Center Back Connection. Front orientation. Vacuum Gauges, Center-Back Connection.

    Bottom Connection

    Center-Back

    Connection

    Bottom

    Connection

    Center Back

    Connection

    Gauges with a steel case are more impact resistant than gauges with an ABS case.
    Available Vacuum Ranges
    Bottom
    Connection
    Center-Back
    Connection
    Dial
    Dia.
    Pipe
    Size
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Case
    Color
    Vacuum Range
    Graduations
    Pressure Numeric
    Increments
    For Use
    With
    Accuracy
    Each
    Each
    NPT Male with Calibration Certificate Traceable to NIST
    1 1/2"1/8
    -40 to 150-40 to 150Black-30 in. Hg to 0 in. Hg
    -100 kPa to 0 kPa
    0.5 in. Hg
    2 kPa
    5 in. Hg
    10 kPa
    Air±2% Midscale (Grade B)4002K1240000004002K125000000
    2"1/4
    -40 to 150-40 to 150Black-30 in. Hg to 0 in. Hg
    -100 kPa to 0 kPa
    0.5 in. Hg
    2 kPa
    5 in. Hg
    10 kPa
    Air±2% Midscale (Grade B)4002K142000004002K16700000
    2 1/2"1/8
    -40 to 150-40 to 150Black-30 in. Hg to 0 in. Hg
    -100 kPa to 0 kPa
    0.5 in. Hg
    2 kPa
    5 in. Hg
    10 kPa
    Air±2% Midscale (Grade B)4002K16600000———0
    2 1/2"1/4
    -40 to 150-40 to 150Black-30 in. Hg to 0 in. Hg
    -100 kPa to 0 kPa
    0.5 in. Hg
    2 kPa
    5 in. Hg
    10 kPa
    Air±2% Midscale (Grade B)4002K145000004002K14400000
    3 1/2"1/4
    -40 to 150-40 to 150Black-30 in. Hg to 0 in. Hg
    -100 kPa to 0 kPa
    0.5 in. Hg
    2 kPa
    5 in. Hg
    10 kPa
    Air±2% Midscale (Grade B)4002K14800000———0
     

    Vibration- and Corrosion-Resistant Vacuum Gauges

    Designed for harsh environments prone to vibration, these gauges pair a corrosion-resistant 304 stainless steel case with a glycerin-filled dial to reduce needle flutter. Use them with vacuum pumps, packaging equipment, and in suction lines to measure and display vacuum.
    304 Stainless Steel Case with Brass Connection—Dual Scale (Inches of Mercury, Kilopascals)
    Image of Product. Front orientation. Vacuum Gauges. Vibration- and Corrosion-Resistant Vacuum Gauges, Dual Scale, Bottom Connection.
    Image of Product. Front orientation. Vacuum Gauges. Vibration- and Corrosion-Resistant Vacuum Gauges, Dual Scale, Center-Back Connection.
    Image of Product. Front orientation. Vacuum Gauges. Vibration- and Corrosion-Resistant Vacuum Gauges, Dual Scale, Lower-Back Connection.
    Image of Attribute. Bottom Connection. Front orientation. Vibration- and Corrosion-Resistant Vacuum Gauges, Bottom Connection.
    Image of Attribute. Center Back Connection. Front orientation. Vibration- and Corrosion-Resistant Vacuum Gauges, Center-Back Connection.
    Image of Attribute. Lower Back
Connection. Front orientation. Vibration- and Corrosion-Resistant Vacuum Gauges, Lower-Back Connection.

    Bottom Connection

    Center-Back

    Connection

    Lower-Back Connection

    Bottom

    Connection

    Center Back

    Connection

    Lower

    Back Connection

    Available Vacuum Ranges
    Bottom
    Connection
    Center-Back
    Connection
    Lower-Back
    Connection
    Dial
    Dia.
    Pipe
    Size
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Liquid
    Type
    Vacuum Range
    Graduations
    Pressure Numeric
    Increments
    For Use
    With
    Accuracy
    Each
    Each
    Each
    NPT Male with Calibration Certificate Traceable to NIST
    2 1/2"1/4
    35 to 14035 to 140Glycerin-30 in. Hg to 0 in. Hg
    -100 kPa to 0 kPa
    0.5 in. Hg
    2 kPa
    5 in. Hg
    10 kPa
    Air±1% Midscale (Grade A)38545K321000000038545K3510000000———0
    4"1/4
    35 to 14035 to 140Glycerin-30 in. Hg to 0 in. Hg
    -100 kPa to 0 kPa
    0.5 in. Hg
    1 kPa
    5 in. Hg
    10 kPa
    Air±1% Full Scale (Grade 1A)38545K331000000———038545K3610000000
     

    High-Accuracy Vacuum Transmitters

    These transmitters, also known as transducers, convert vacuum to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor vacuum or control equipment. As vacuum decreases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's vacuum range and output signal. Transmitters will only provide accurate readings within the rated vacuum range.
    4 mA to 20 mA Output Current—Wire Lead Connection
    Image of Product. Front orientation. Contains Annotated. Vacuum Transmitters. High-Accuracy Vacuum Transmitters.
    These transmitters connect using two wires to send a 4 to 20 mA current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn't lose signal over long distances and isn't affected by electrical interference from other devices.
    Calibration Certificate Traceable to NIST—All come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy.
    ±0.25% Accuracy—At least four times as accurate as standard vacuum transmitters, these transmitters sense vacuum at an accuracy of ±0.25%, making them ideal for use in laboratories and in analytical testing applications.
    IP67 Enclosure Rating and NEMA 4X Enclosure Rating—IP and NEMA rated, these transmitters withstand weather, corrosion, and brief submersion. They’re CE marked, so they meet European safety standards.
    Calibration
    Certificate Traceable to NIST
    Vacuum Range,
    in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Input Voltage,
    V DC
    Ht.
    Wd.
    For Use With
    Accuracy
    Housing Material
    Connection Material
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    1/4 NPT Male Threaded Pipe Connection
    0 to 29.90159 to 301 5/16"1"Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±0.25%304 Stainless Steel
    17-4 PH Stainless Steel-40 to 255IP67, NEMA 4X
    5785N110000000
     

    Vacuum Test Gauges

    Test and calibrate transmitters, gauges, and other equipment that measures vacuum.
    Aluminum Case with Brass Connection—Dual Scale (in. of Hg, kPa)
    Image of Product. Front orientation. Vacuum Test Gauges. Bottom Connection (Flange Mount).
    Image of Product. Front orientation. Vacuum Test Gauges. Lower-Back Connection (Flange Mount).
    Image of Specification. Front orientation. Bottom Connection.
    Image of Specification. Front orientation. Lower-Back Connection.

    Bottom Connection

    (Flange Mount)

    Lower-Back Connection

    (Flange Mount)

    Bottom

    Connection

    Lower-Back

    Connection

    Bolt
    Flange
    Bottom Connection
    (Flange Mount)
    Lower-Back
    Connection (Flange Mount)
    Dial
    Dia.
    Vacuum Range
    Graduations
    Pressure Numeric
    Increments
    Pipe
    Size
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Mounting Fasteners
    Included
    Circle
    Dia.
    Hole Thread
    Size
    No. of
    Holes
    Location
    OD
    For Use
    With
    Accuracy
    Each
    Each
    NPT Male—Calibration Certificate Traceable to NIST
    4 1/2"0 in. Hg to 30 in. Hg
    -100 kPa to 0 kPa
    0.1 in. Hg
    0.5 kPa
    1 in. Hg
    5 kPa
    1/4
    -20 to 200-20 to 250No5 3/8"10-24
    3Front6 3/32"Air±0.25% Full Scale (Grade 3A)4105K3100000004105K330000000
    6"0 in. Hg to 30 in. Hg
    -100 kPa to 0 kPa
    0.1 in. Hg
    0.5 kPa
    1 in. Hg
    10 kPa
    1/4
    -20 to 200-20 to 250No7"1/4"-20
    3Front7 9/16"Air±0.25% Full Scale (Grade 3A)4105K320000004105K34000000
     

    Differential Pressure and Vacuum Gauges with Digital Display

    Gauges have a four-digit LCD display for easy reading of measurements. Commonly used to indicate clogged filters, these gauges display the difference between two pressure or vacuum measurements. They are also known as compound gauges.
    Aluminum Case with Brass Connection—(psi, kPa, in. of H₂O, in. of Hg, mbar)
    Image of Product. Front orientation. Differential Pressure and Vacuum Gauges. Differential Pressure and Vacuum Gauges with Digital Display .
    Pressure Range
    Vacuum Range,
    in. Hg
    Pressure Resolution,
    in. H₂O
    Max. Pressure
    For Tube ID
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Digit
    Ht.
    Batteries
    Included
    Features
    For Use
    With
    Accuracy
    Each
    Barbed Fitting Connection with Calibration Certificate Traceable to NIST
    0 psi to 0.723 psi
    0 psi to 10 psi
    0 kPa to 4.982 kPa
    0 in. H₂O to 20 in. H₂O
    0 mbar to 49.82 mbar
    0 to 1.4710.010.723 psi; 10 psi; 4.982 kPa; 20 in. H₂O; 49.82 mbar1/8" to 3/16"35 to 1000 to 1403/8"Yes40-Reading Memory, Overpressure AlarmAir±0.5% Full-Scale Accuracy (Not Rated)4125K610000000
    0 psi to 7.225 psi
    0 psi to 30 psi
    0 kPa to 49.82 kPa
    0 in. H₂O to 200 in. H₂O
    0 mbar to 498.2 mbar
    0 to 14.710.17.225 psi; 30 psi; 49.82 kPa; 200 in. H₂O; 498.2 mbar1/8" to 3/16"35 to 1000 to 1403/8"Yes40-Reading Memory, Overpressure AlarmAir±0.5% Full-Scale Accuracy (Not Rated)4125K63000000
    0 psi to 20 psi
    0 psi to 60 psi
    0 kPa to 137.9 kPa
    0 in. H₂O to 553 in. H₂O
    0 mbar to 1,379 mbar
    0 to 40.720.0120 psi; 60 psi; 137.9 kPa; 553 in. H₂O; 1,379 mbar1/8" to 3/16"35 to 1000 to 1403/8"Yes40-Reading Memory, Overpressure AlarmAir±0.5% Full-Scale Accuracy (Not Rated)4125K66000000
     

    High-Accuracy Pressure and Vacuum Transmitters

    With an accuracy of ±0.25%, use these transmitters in applications that require highly accurate measurement of both pressure and vacuum, such as activating vacuum pumps. All come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. They convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. As pressure increases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the pressure range and output signal of the transmitter. Transmitters will only provide accurate readings within the rated pressure range.
    Rated IP67 and NEMA 4X, these transmitters seal out dust and water from temporary submersion. All are CE marked, so they meet European safety standards.
    These transmitters connect using two wires to send a 4-20mA current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    4 mA to 20 mA Output Current Range—Wire Leads
    Image of Product. Front orientation. Contains Annotated. Pressure and Vacuum Transmitters. High-Accuracy Pressure and Vacuum Transmitters.
    Max.
    Pressure, psi
    Transmitters with Calibration
    Certificate Traceable to NIST
    Pressure
    Range, psi
    Vacuum Range,
    in. Hg
    Continuous
    Short-Term
    Input Voltage,
    V DC
    Pipe Size
    Ht.
    Wd.
    Enclosure
    Rating
    For Use With
    Accuracy
    Temp. Range,
    ° F
    Connection Material
    Each
    304 Stainless Steel Housing
    0 to 150 to 29.915309 to 301/4 NPT Male2 1/8"1"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±0.25%-40 to 25517-4 PH Stainless Steel5472N110000000
    0 to 250 to 29.925509 to 301/4 NPT Male2 1/8"1"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±0.25%-40 to 25517-4 PH Stainless Steel5472N12000000
    0 to 500 to 29.9501009 to 301/4 NPT Male2 1/8"1"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±0.25%-40 to 25517-4 PH Stainless Steel5472N13000000
    0 to 1000 to 29.91002009 to 301/4 NPT Male2 1/8"1"IP67, NEMA 4X
    Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water±0.25%-40 to 25517-4 PH Stainless Steel5472N14000000
     

    Ultra-Low Vacuum Gauges

    Accommodate applications with very low vacuum with these gauges. Use them with vacuum pumps, packaging equipment, and in suction lines to measure and display vacuum.
    Painted Steel Case with Brass Connection—Single Scale (Inches of Water)
    Image of Product. Front orientation. Vacuum Gauges. Ultra-Low Vacuum Gauges, Single Scale, Bottom Connection.
    Image of Attribute. Bottom Connection. Front orientation. Ultra-Low Vacuum Gauges, Bottom Connection.

    Bottom

    Connection

    Bottom

    Connection

    Available Vacuum
    Ranges, in. H₂O
    Bottom
    Connection
    Dial
    Dia.
    Pipe
    Size
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Case
    Color
    Vacuum
    Range
    Graduations
    Pressure Numeric
    Increments
    For Use
    With
    Accuracy
    Each
    NPT Male with Calibration Certificate Traceable to NIST
    2 1/2"1/4
    0 to 1400 to 175Black-100 to 0220Air±1.6% Full Scale (Not Rated)3843K340000000
    2 1/2"1/4
    0 to 1400 to 175Black-60 to 0110Air±1.6% Full Scale (Not Rated)3843K33000000
    2 1/2"1/4
    0 to 1400 to 175Black-30 to 00.55Air±1.6% Full Scale (Not Rated)3843K32000000
    2 1/2"1/4
    0 to 1400 to 175Black-15 to 00.23Air±1.6% Full Scale (Not Rated)3843K31000000
     
    304 Stainless Steel Case with Brass Connection—Single Scale (Inches of Water)
    Image of Product. Front orientation. Vacuum Gauges. Ultra-Low Vacuum Gauges, Single Scale, Bottom Connection.
    Image of Attribute. Bottom Connection. Front orientation. Ultra-Low Vacuum Gauges, Bottom Connection.

    Bottom

    Connection

    Bottom

    Connection

    Gauges with a 304 stainless steel case have better corrosion resistance than gauges with a steel case.
    Available Vacuum
    Ranges, in. H₂O
    Bottom
    Connection
    Dial
    Dia.
    Pipe
    Size
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Vacuum
    Range
    Graduations
    Pressure Numeric
    Increments
    For Use
    With
    Accuracy
    Each
    NPT Male with Calibration Certificate Traceable to NIST
    4"1/4
    0 to 1400 to 175-100 to 0220Air±1% Full Scale (Not Rated)3843K440000000
    4"1/4
    0 to 1400 to 175-60 to 0110Air±1% Full Scale (Not Rated)3843K43000000
    4"1/4
    0 to 1400 to 175-30 to 00.55Air±1% Full Scale (Not Rated)3843K42000000
    4"1/4
    0 to 1400 to 175-15 to 00.23Air±1% Full Scale (Not Rated)3843K41000000
     

    Differential Pressure and Vacuum Gauges

    Commonly used to indicate clogged filters, these gauges display the difference between two pressure or vacuum measurements. They are also known as compound gauges.
    Aluminum Case with Aluminum Connection—Single Scale (in. of H₂O)
    Image of Product. Front orientation. Differential Pressure and Vacuum Gauges. Differential Pressure and Vacuum Gauges.
    Pressure Range, in. H₂O
    Vacuum Range,
    in. H₂O
    Graduations,
    in. H₂O
    Pressure Numeric
    Increments, in. H₂O
    Dial
    Dia.
    Pipe
    Size
    Max. Pressure
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Features
    Includes
    For Use
    With
    Accuracy
    Each
    NPT Female with Calibration Certificate Traceable to NIST
    0 to 0.2
    0 to 15
    -0.05 to 00.010.054"1/8
    0.2 in. H₂O, 15 psi20 to 14020 to 140Two Inlets and Two OutletsPlugs for Unused PortsAir±4% Full-Scale Accuracy (Not Rated)4021K7130000000
    0 to 0.25
    0 to 15
    -0.25 to 00.010.054"1/8
    0.25 in. H₂O, 15 psi20 to 14020 to 140Two Inlets and Two OutletsPlugs for Unused PortsAir±3% Full-Scale Accuracy (Not Rated)4021K733000000
    0 to 0.5
    0 to 15
    -0.5 to 00.020.14"1/8
    0.5 in. H₂O, 15 psi20 to 14020 to 140Two Inlets and Two OutletsPlugs for Unused PortsAir±2% Full-Scale Accuracy (Not Rated)4021K734000000
    0 to 1
    0 to 15
    -1 to 00.050.254"1/8
    1 in. H₂O, 15 psi20 to 14020 to 140Two Inlets and Two OutletsPlugs for Unused PortsAir±2% Full-Scale Accuracy (Not Rated)4021K735000000
    0 to 5
    0 to 15
    -5 to 00.214"1/8
    5 in. H₂O, 15 psi20 to 14020 to 140Two Inlets and Two OutletsPlugs for Unused PortsAir±2% Full-Scale Accuracy (Not Rated)4021K736000000
    0 to 10
    0 to 15
    -10 to 00.554"1/8
    10 in. H₂O, 15 psi20 to 14020 to 140Two Inlets and Two OutletsPlugs for Unused PortsAir±2% Full-Scale Accuracy (Not Rated)4021K737000000
    0 to 15
    0 to 15
    -15 to 0154"1/8
    15 in. H₂O, 15 psi20 to 14020 to 140Two Inlets and Two OutletsPlugs for Unused PortsAir±2% Full-Scale Accuracy (Not Rated)4021K738000000
     

    Vibration- and Corrosion-Resistant Pressure and Vacuum Gauges

    Image of Product. Front orientation. Pressure and Vacuum Gauges. Vibration- and Corrosion-Resistant Pressure and Vacuum Gauges, Dual Scale, Bottom Connection.
    Image of Product. Front orientation. Pressure and Vacuum Gauges. Vibration- and Corrosion-Resistant Pressure and Vacuum Gauges, Dual Scale, Center-Back Connection.
    Image of Product. Front orientation. Pressure and Vacuum Gauges. Vibration- and Corrosion-Resistant Pressure and Vacuum Gauges, Dual Scale, Lower-Back Connection.
    Image of Attribute. Bottom Connection. Front orientation. Bottom Connection. Vibration- and Corrosion-Resistant Pressure and Vacuum Gauges.
    Image of Attribute. Center Back Connection. Front orientation. Center-Back Connection. Vibration- and Corrosion-Resistant Pressure and Vacuum Gauges.
    Image of Attribute. Lower Back
Connection. Front orientation. Lower-Back Connection. Vibration- and Corrosion-Resistant Pressure and Vacuum Gauges.

    Dual Scale,

    Bottom

    Connection

    Dual Scale,

    Center-Back

    Connection

    Dual Scale

    Lower-Back Connection

    Bottom

    Connection

    Center Back

    Connection

    Lower

    Back Connection

    Designed for harsh environments prone to vibration, these gauges pair a corrosion-resistant 304 stainless steel case with a glycerin-filled dial that reduces needle flutter. Also known as compound gauges, they measure both pressure and vacuum. Use them with pumps, filters, regulators, compressors, and in suction and process lines.
    Bottom
    Connection
    Center-Back
    Connection
    Lower-Back
    Connection
    Dial
    Dia.
    Pipe
    Size
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Lens
    Material
    Liquid
    Type
    Pressure
    Vacuum
    Graduations
    Pressure Numeric
    Increments
    For Use
    With
    Accuracy
    Each
    Each
    Each
    304 Stainless Steel Case with Brass Connection—Dual Scale (Inches of Mercury, Kilopascals, Pounds per Square Inch)
     
    NPT Male with Calibration Certificate Traceable to NIST
    2 1/2"1/4
    35 to 14035 to 140Polycarbonate
    Glycerin0 psi to 15 psi; 0 kPa to 100 kPa-100 in. Hg to 30 in. Hg, 0 in. Hg to 30 in. Hg, -100 kPa to 0 kPa1 in. Hg, 0.5 psi, 5 kPa10 in. Hg, 5 psi, 50 kPaAir, Water±1% Midscale (Grade A)38545K322000000038545K3520000000———0
    2 1/2"1/4
    35 to 14035 to 140Polycarbonate
    Glycerin0 psi to 30 psi; 0 kPa to 200 kPa-100 in. Hg to 30 in. Hg, 0 in. Hg to 30 in. Hg, -100 kPa to 0 kPa2 in. Hg, 1 psi, 5 kPa10 in. Hg, 10 psi, 50 kPaAir, Water±1% Midscale (Grade A)38545K32300000038545K353000000———0
    2 1/2"1/4
    35 to 14035 to 140Polycarbonate
    Glycerin0 psi to 60 psi; 0 kPa to 400 kPa-100 in. Hg to 30 in. Hg, 0 in. Hg to 30 in. Hg, -100 kPa to 0 kPa2 in. Hg, 2 psi, 10 kPa30 in. Hg, 20 psi, 100 kPaAir, Water±1% Midscale (Grade A)38545K32400000038545K354000000———0
    2 1/2"1/4
    35 to 14035 to 140Polycarbonate
    Glycerin0 psi to 100 psi; 0 kPa to 680 kPa-100 in. Hg to 30 in. Hg, 0 in. Hg to 30 in. Hg, -100 kPa to 0 kPa2 psi, 5 in. Hg, 10 kPa30 in. Hg, 20 psi, 200 kPaAir, Water±1% Midscale (Grade A)38545K32500000038545K355000000———0
    2 1/2"1/4
    35 to 14035 to 140Polycarbonate
    Glycerin0 psi to 160 psi; 0 kPa to 1,100 kPa-100 in. Hg to 30 in. Hg, 0 in. Hg to 30 in. Hg, -100 kPa to 0 kPa10 in. Hg, 5 psi, 20 kPa30 in. Hg, 40 psi, 200 kPaAir, Water±1% Midscale (Grade A)38545K32600000038545K356000000———0
    2 1/2"1/4
    35 to 14035 to 140Polycarbonate
    Glycerin0 psi to 200 psi; 0 kPa to 1,350 kPa-100 in. Hg to 30 in. Hg, 0 in. Hg to 30 in. Hg, -100 kPa to 0 kPa10 in. Hg, 5 psi, 50 kPa30 in. Hg, 50 psi, 200 kPaAir, Water±1% Midscale (Grade A)38545K32700000038545K357000000———0
    2 1/2"1/4
    35 to 14035 to 140Polycarbonate
    Glycerin0 psi to 300 psi; 0 kPa to 2,050 kPa-100 in. Hg to 30 in. Hg, 0 in. Hg to 30 in. Hg, -100 kPa to 0 kPa10 in. Hg, 5 psi, 50 kPa30 in. Hg, 50 psi, 500 kPaAir, Water±1% Midscale (Grade A)38545K32800000038545K358000000———0
    4"1/4
    35 to 14035 to 140Polycarbonate
    Glycerin0 psi to 15 psi; 0 kPa to 100 kPa-100 in. Hg to 30 in. Hg, 0 in. Hg to 30 in. Hg, -100 kPa to 0 kPa1 in. Hg, 0.5 psi, 2 kPa5 in. Hg, 3 psi, 20 kPaAir, Water±1% Full Scale (Grade 1A)38545K332000000———038545K3620000000
    4"1/4
    35 to 14035 to 140Polycarbonate
    Glycerin0 psi to 30 psi; 0 kPa to 205 kPa-100 in. Hg to 30 in. Hg, 0 in. Hg to 30 in. Hg, -100 kPa to 0 kPa1 in. Hg, 0.5 psi, 5 kPa10 in. Hg, 5 psi, 50 kPaAir, Water±1% Full Scale (Grade 1A)38545K333000000———038545K363000000
    4"1/4
    35 to 14035 to 140Polycarbonate
    Glycerin0 psi to 60 psi; 0 kPa to 410 kPa-100 in. Hg to 30 in. Hg, 0 in. Hg to 30 in. Hg, -100 kPa to 0 kPa2 in. Hg, 2 psi, 10 kPa10 in. Hg, 10 psi, 100 kPaAir, Water±1% Full Scale (Grade 1A)38545K334000000———038545K364000000
    4"1/4
    35 to 14035 to 140Polycarbonate
    Glycerin0 psi to 100 psi; 0 kPa to 680 kPa-100 in. Hg to 30 in. Hg, 0 in. Hg to 30 in. Hg, -100 kPa to 0 kPa2 psi, 5 in. Hg, 10 kPa10 psi, 30 in. Hg, 100 kPaAir, Water±1% Full Scale (Grade 1A)38545K335000000———038545K365000000
    4"1/4
    35 to 14035 to 140Polycarbonate
    Glycerin0 psi to 160 psi; 0 kPa to 1,100 kPa-100 in. Hg to 30 in. Hg, 0 in. Hg to 30 in. Hg, -100 kPa to 0 kPa5 in. Hg, 5 psi, 20 kPa30 in. Hg, 20 psi, 100 kPaAir, Water±1% Full Scale (Grade 1A)38545K336000000———038545K366000000
    4"1/4
    35 to 14035 to 140Polycarbonate
    Glycerin0 psi to 200 psi; 0 kPa to 1,360 kPa-100 in. Hg to 30 in. Hg, 0 in. Hg to 30 in. Hg, -100 kPa to 0 kPa5 in. Hg, 5 psi, 20 kPa30 in. Hg, 20 psi, 200 kPaAir, Water±1% Full Scale (Grade 1A)38545K337000000———038545K367000000
    4"1/4
    35 to 14035 to 140Polycarbonate
    Glycerin0 psi to 300 psi; 0 kPa to 2,050 kPa-100 in. Hg to 30 in. Hg, 0 in. Hg to 30 in. Hg, -100 kPa to 0 kPa10 in. Hg, 5 psi, 50 kPa30 in. Hg, 50 psi, 500 kPaAir, Water±1% Full Scale (Grade 1A)38545K338000000———038545K368000000
     
    back to top