McMaster-Carr logo
    Filter by
    Operates On
    Pipe Size
    Industrial Info Compare
    Set Point Adjustability
    Thread Type
    Industrial Info Compare
    Wire Connection
    Switch Starting Position
    Industrial Info Compare
    Approximate Difference Between Set Point and Reset Point
    Electrical Connection
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    56 Products

    Economy Vacuum Switches

    Image of Product. Top orientation. Vacuum Switches. Economy Vacuum Switches.
    Choose these switches when you need reliable switching but not high accuracy. When they reach a set vacuum, they turn equipment on and off, signal automatic controls, or trigger alarms. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed). All meet American and European safety standards since they're UL recognized components and CE marked.
    Pressure Set
    Point, in. Hg
    Approx. Difference Between Set
    Point and Reset Point, in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current
    @ Voltage
    Process Temp.
    Range, ° F
    Connection Material
    For Use With
    Each
    Spade-Terminal
     
    1/8 NPT Male Pipe Connection
    2.7 to 28.2300±5%5 amp @ 250V AC-30 to 185Chrome-Plated Zinc AlloyAir, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Oxygen, Water8128N120000000
     

    Fixed Setpoint Vacuum Switches

    Image of Product. Front orientation. Vacuum Switches. Fixed Setpoint Vacuum Switches.
    Prevent changes to the set vacuum that powers equipment, activates controls, or signals alarms. The setpoint on these switches isn't adjustable. They’re single pole, double throw (SPDT) and can either turn one circuit from off to on (normally open) or on to off (normally closed).
    NEMA 4 Enclosure Rating—NEMA 4 rated, they seal out dirt, oil, and water from washdowns. All meet American, Canadian, and European safety standards since they’re UL and C-UL recognized components and CE marked.
    NEMA 13 Enclosure Rating—NEMA 13 rated, they seal out dirt, oil, and water from washdowns. All meet American, Canadian, and European safety standards since they’re UL and C-UL recognized components and CE marked.
    Pressure Set
    Point, in. Hg
    Approx. Reset
    Point, in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Quick-Disconnect-Terminal
     
    1/4 NPT Male Pipe Connection
    2817250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N25000000
    2616250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N2400000
    2415250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N2300000
    2214250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N2200000
    2012250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N2100000
    1811250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1900000
    1610250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1800000
    149250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1700000
    128250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1600000
    106250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1500000
    85250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1400000
    63250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1300000
    42250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1200000
    21250750±2%10 amp @ 125V AC
    10 amp @ 250V AC
    5 amp @ 30V DC
    -20 to 220BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 4, NEMA 13
    8198N1100000
     

    Dual-Setpoint Electronic Vacuum Switches for Compressed Air

    Image of Product. Front orientation. Vacuum Switches. Dual-Setpoint Electronic Vacuum Switches for Compressed Air.
    Trigger two different processes in vacuum applications by sending signals to a programmable logic controller (PLC) when these switches reach one of their two set vacuums. Designed specifically for air systems, they can turn on a vacuum pump if the vacuum is too low or a valve if the vacuum is too high. Or use them to signal an alarm before switching off a pump. Check the vacuum on the display and change your setpoint, reset point, scaling, and other settings using the buttons.
    Adjustable—An adjustable reset means you can control the amount of pressure change before the switch resets. This pressure difference is commonly referred to as deadband and differential. Choose anywhere within the setpoint range for your reset point.
    IP65 Enclosure Rating—Rated IP65, these switches seal out dust and water from light rinses. They meet American, Canadian, and European safety standards since they’re UL and C-UL recognized components as well as CE marked.
    Pressure Set
    Point, in. Hg
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Output Digital
    Signal
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Wire-Lead
     
    1/8 NPT Male Pipe Connection
    0 to 30Adjustable14.672PNP±0.2%35 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, Hydraulic Fluid, Inert Gas, Nitrogen, WaterIP65
    8054N110000000
     
    Square Panel-Mount Brackets

    Vacuum Switches

    The traditional vacuum switch. When these switches reach a set vacuum, they power equipment, signal controls, or trigger alarms. They’re larger and easier to wire than our compact vacuum switches. All are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Vacuum Switches
    Image of Product. Front orientation. Contains Annotated. Vacuum Switches. Vacuum Switches.
    NEMA 1 Enclosure Rating—NEMA rated, they protect against some corrosion but shouldn’t be used outdoors. They all meet safety standards.
    Pressure Set
    Point, in. Hg
    Approx. Difference Between Set
    Point and Reset Point, in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection Material
    For Use With
    Enclosure
    Rating
    Each
    Screw-Terminal
     
    1/2 NPT Male Pipe Connection
    3 to 29114.730±2%3 amp @ 480V AC
    10 amp @ 125V AC
    10 amp @ 250V AC
    -20 to 165Nickel-Plated AluminumAir, Hydraulic Fluid, Nitrogen, Oil, WaterNEMA 1
    40925K910000000
     
    Vacuum Switches with Cover
    Image of Specification. Front orientation. Contains Annotated. Vacuum Switches. Vacuum Switches, Vacuum Switches with Cover.
    Switches with a cover protect against impact and keep dust off the switch.
    NEMA 1 Enclosure Rating—NEMA rated, they protect against some corrosion but shouldn’t be used outdoors. They all meet safety standards.
    Pressure Set
    Point, in. Hg
    Approx. Difference Between Set
    Point and Reset Point, in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Screw-Terminal
     
    1/4 NPT Male Pipe Connection
    0 to 302050±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    0 to 200AluminumAir, Hydraulic Fluid (Petroleum Based)NEMA 1
    4779K110000000
     

    Electronic Vacuum Switches for Compressed Air

    Image of Product. Front orientation. Vacuum Switches. Electronic Vacuum Switches for Compressed Air.
    Specifically made for air systems, these switches send signals to your programmable logic controller (PLC) to trigger processes when they reach a set vacuum. Use them to turn equipment on or off, activate automated controls, or signal alarms. Check the vacuum on the display and change your setpoint, reset point, scaling, and other settings using the buttons. All switches meet at least one American, Canadian, or European safety standard.
    Vacuum Switches with 1 Configurable Output—Switches with configurable outputs give you flexibility to choose between PNP, NPN, or IO Link. When using IO Link, you can remotely control and monitor your vacuum from your PLC or PC when you connect an IO Link controller (not included).
    Adjustable—An adjustable reset point means you can control the amount of vacuum change before the switch resets, also known as deadband or differential. Choose anywhere within the setpoint range for your reset point.
    IP65 Enclosure Rating—IP65 rated switches protect against dust and light rinses.
    Digital
    Output
    Configurable
    Digital Output
    Pressure Set
    Point, in. Hg
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    No.
    of
    Signal
    Type
    Signal
    Type
    Control Communication
    Protocol
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Vacuum Switches
     
    Wire Leads—1/8 NPT Male Pipe Connection
    0 to 30Adjustable14.71PNP±0.2%25 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, NitrogenIP40
    8023N11000000
     
    Vacuum Switches with 1 Configurable Output
     
    Wire Leads—1/8 NPT Male Pipe Connection
    0 to 30Adjustable14.7PNP, NPNIO-Link±0.2%35 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, NitrogenIP65
    8023N12000000
     
    Square Panel-Mount Brackets

    Pressure and Vacuum Switches

    Image of Product. Front orientation. Pressure and Vacuum Switches. Pressure and Vacuum Switches.
    Because these switches work with both positive and negative (vacuum) pressures, you can use them in applications that span both. For example, these switches can turn on a light when they reach the setpoint to indicate which pressure is flowing. They’re also often used to trigger automated controls and activate alarms. These switches are single pole, double throw (SPDT) and can either turn one circuit from off to on or from on to off.
    NEMA 4X and IP66 rated, they’re dust tight and protected from washdowns and corrosion. All are UL and C-UL listed, CSA and CSA-US certified, and CE marked, so they meet U.S., Canadian, and European safety standards.
    Set Point
    Pressure,
    psi
    Vacuum,
    in. Hg
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Screw-Terminal Wire Connection
     
    1/4 NPT Female
    0 to 150 to 301.515250±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    3871N110000000
    0 to 300 to 302.2530250±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    3871N12000000
    0 to 600 to 30460250±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 250V DC
    20 to 300316 Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterIP66, NEMA 4X
    3871N13000000
     

    Adjustable-Reset Vacuum Switches

    Control the amount of vacuum change between when these switches activate and deactivate by adjusting when they reset. Also known as adjustable deadband and differential switches, you can set the reset point anywhere within the setpoint range. Use them to power equipment, signal controls, or trigger alarms when they reach the set vacuum. They’re single pole, double throw (SPDT) and can either turn one circuit from off to on (normally open) or on to off (normally closed). All meet safety standards.
    All protect against some corrosion.
    Vacuum Switches
    Image of Product. Front orientation. Vacuum Switches. Adjustable-Reset Vacuum Switches.
    NEMA 4X Enclosure Rating—NEMA 4X rated switches can be used in dirty and wet areas exposed to washdowns. They also stand up to weather and have increased protection against corrosion, similar to 304 stainless steel.
    IP66 Enclosure Rating—IP66 rated switches can be used in dirty and wet areas exposed to washdowns.
    Pressure Set
    Point, in. Hg
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection Material
    For Use With
    Enclosure
    Rating
    Each
    Screw-Terminal
     
    1/4 NPT Female Pipe Connection
    6 to 24Adjustable11.7250±1%10 amp @ 125V AC
    10 amp @ 250V AC
    250 mA @ 250V AC
    500 mA @ 125V DC
    20 to 300316L Stainless SteelAir, Diesel Fuel, Gasoline, Hydraulic Fluid, WaterNEMA 4X, IP66
    8015N110000000
     
    Vacuum Switches with On/Off Indicator
    Image of Product. Front orientation. Contains Annotated. Vacuum Switches. Adjustable-Reset Vacuum Switches, Vacuum Switches with On/Off Indicator.
    Switches with an on/off indicator let you monitor the equipment it’s controlling even when it’s out of sight.
    NEMA 1 Enclosure Rating—NEMA 1 rated switches should only be used indoors.
    Pressure Set
    Point, in. Hg
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Screw-Terminal
     
    1/4 NPT Male Pipe Connection
    0 to 30Adjustable14.714.7±1%15 amp @ 120V AC
    15 amp @ 240V AC
    15 amp @ 480V AC
    35 to 180BrassAir, Diesel Fuel, Hydraulic Fluid, WaterNEMA 1
    4941K51000000000
     

    Compact Vacuum Switches

    Image of Product. Wire-Lead. Front orientation. Contains Annotated. Wire-Lead. Compact Vacuum Switches.
    Image of Product. DIN A Connection. Front orientation. Contains Annotated. DIN A Connection. Compact Vacuum Switches.

    Wire-Lead

    DIN A

    Connection

    Often built into pumps and hydraulic systems with limited space, these compact switches power equipment, activate controls, and signal alarms when they reach a set vacuum. Quickly adjust their setpoint by twisting the external ring. All are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed). UL listed or a UL recognized component, these switches meet American safety standards.
    NEMA 1 Enclosure Rating—NEMA 1 rated switches protect against some corrosion, but they shouldn’t be used outdoors.
    NEMA 4 Enclosure Rating—NEMA 4 rated switches protect against corrosion and seal out dust and water from washdowns and the weather.
    IP65 Enclosure Rating—IP65 rated switches stand up to dust and light rinses.
    Pressure Set
    Point, in. Hg
    Approx. Difference Between Set
    Point and Reset Point, in. Hg
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current
    @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Wire-Lead
     
    1/4 NPT Male Pipe Connection
    6 to 28414.730±2%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 165BrassAir, Hydraulic Fluid, Oil, WaterNEMA 1
    3806N110000000
    6 to 28414.730±2%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 165BrassAir, Hydraulic Fluid, Oil, WaterNEMA 4
    46995K34000000
     
    DIN A Connection
     
    1/4 NPT Male Pipe Connection
    6 to 28414.730±2%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 165BrassAir, Hydraulic Fluid, Oil, WaterIP65
    3806N12000000
     

    Electronic Pressure and Vacuum Switches for Compressed Air

    Image of Product. Front orientation. Pressure and Vacuum Switches. Electronic Pressure and Vacuum Switches for Compressed Air.
    Designed specifically for air systems, these switches send signals to your programmable logic controller (PLC) to activate controls or alarms when your system reaches a set pressure or vacuum. All meet at least one American, Canadian, or European safety standard.
    Monitor pressure, setpoint, and reset point on the digital display. Use the display’s buttons to change your settings. These switches have an adjustable reset point (also called adjustable deadband or differential), so you can control the amount of pressure or vacuum change before the switch resets. Choose anywhere within the setpoint range for your reset point.
    1 Configurable Output—Switches with 1 configurable output give you flexibility to choose between PNP, NPN, or IO-Link. When using IO-Link, you can remotely control and monitor your vacuum from your PLC or PC when you connect an IO-Link controller (not included).
    IP65 Enclosure Rating—IP65 rated switches protect from dust and light rinsing.
    Set Point
    Pressure,
    psi
    Vacuum,
    in. Hg
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Switches (PNP)
     
    Wire Leads—1/8 NPT Male
    0 to 14 1/20 to 29Adjustable14.572±0.2%25 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, Inert Gas, NitrogenIP40
    3875N11000000
     
    Switches with 1 Configurable Output (PNP, NPN, IO-Link)
     
    Wire Leads—1/8 NPT Male
    0 to 14 1/20 to 29Adjustable14.572±0.2%35 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, Inert Gas, NitrogenIP65
    3875N1200000
     
    Square Panel-Mount Brackets

    Pressure and Vacuum Transmitters with Digital Display

    Monitor and control vacuum pumps, air compressors, and hydraulics while viewing readings and warnings on the display. These transmitters, also called transducers, have two outputs, so you can program them to work as a transmitter, a switch, or both. When they reach their setpoint, they send electrical signals to your programmable logic controller (PLC) to trigger actions in your system. Adjust their reset point anywhere within the setpoint range. To change settings and receive error messages remotely from your PLC or computer, program one of the outputs to use IO Link. You need an IO-Link controller (not included) to connect to your interface.
    Buttons on the display let you change your setpoint, measuring range, and other settings. To quickly tell the status of your process, you can program the color of the display to red and green. LEDs on the corners also notify you of your output’s switching status. Rotate the head to view the display from the best angle.
    You must calibrate your PLC in order for it to interpret signals from these transmitters. As pressure increases, the output signal from the transmitter will increase. These transmitters only give accurate readings within the rated pressure or vacuum range.
    All have an M12 plug to connect to M12 Connectors. When using both switching outputs and an IO-Link controller, they require four wires to connect. For their 4-20mA analog output, they need two wires to connect. View switch wiring diagrams by selecting a part number and clicking Product Detail.
    To withstand wet environments, these transmitters have a 316L stainless steel connection and are IP rated. Their IP ratings also mean they’re dust tight and stand up to spraying water and brief submersion. UL and C-UL listed as well as CE marked, they meet strict American, Canadian, and European safety standards.
    4 mA to 20 mA Output Signal—4-Pole M12 Plug-In Connection
    Image of Product. Front orientation. Contains Annotated. Pressure and Vacuum Transmitters. Pressure and Vacuum Transmitters with Digital Display.
    Max.
    Pressure, psi
    Configurable Analog
    Transmitter/Digital Switch Output
    Configurable
    Digital Switch Output
    Pressure Range,
    psi
    Vacuum Range,
    in. Hg
    Continuous
    Short-Term
    Input Voltage,
    V DC
    Ht.
    Wd.
    No.
    Of
    Analog
    Signal
    Digital
    Signal
    No.
    Of
    Digital
    Signal
    Measurement Unit
    For Use With
    Accuracy
    Temp. Range,
    ° F
    Connection Material
    Each
    Glass-Filled Polyester Plastic Housing
     
    1/4 NPT Female
    0 to 14.50 to 29.514514518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPInches of Mercury, Inches of Water, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N140000000
    0 to 1450 to 29.71,0851,08518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N15000000
    0 to 362.50 to 29.52,1752,17518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N16000000
     
    1/4 NPT Male
    0 to 14.50 to 29.514514518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPInches of Mercury, Inches of Water, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N11000000
    0 to 1450 to 29.71,0851,08518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N12000000
    0 to 3600 to 29.52,1752,17518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N13000000
     
    1/4 BSPP Female
    0 to 7.30 to 14.814514518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPInches of Water, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N23000000
    0 to 14.50 to 1.414514518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPInches of Water, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N22000000
    0 to 14.50 to 29.514514518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPInches of Mercury, Inches of Water, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N21000000
    0 to 870 to 29.560060018 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N17000000
    0 to 1450 to 29.71,0851,08518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N18000000
    0 to 3600 to 29.52,1752,17518 to 303 9/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N19000000
     
    1/4 BSPP Male
    0 to 7.30 to 14.814514518 to 303 11/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N27000000
    0 to 14.50 to 1.414514518 to 303 11/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N28000000
    0 to 14.50 to 29.514514518 to 303 11/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPInches of Mercury, Inches of Water, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N29000000
    0 to 870 to 29.560060018 to 303 11/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N24000000
    0 to 1450 to 29.71,0851,08518 to 303 11/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N25000000
    0 to 3600 to 29.514514518 to 303 11/16"1 3/8"14 mA to 20 mANPN, PNP1NPN, PNPBar, Megapascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water±1%-10 to 175316L Stainless Steel4075N26000000
     

    Pressure and Vacuum Transmitters for Compressed Air

    Image of Product. Front orientation. Pressure and Vacuum Transmitters. Pressure and Vacuum Transmitters for Compressed Air.
    Specifically made for compressed air and gas systems, these transmitters remotely monitor pressure and vacuum. Also known as transducers, they convert both pressure and vacuum into an electrical signal that can be interpreted by receiving devices, such as remote displays, and motor speed controls. They also have two digital PNP switch outputs that you can connect to your programmable logic controller (PLC) to activate automated controls or alarms when a set pressure or vacuum is reached. Change settings with the buttons on the digital display.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure or vacuum range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure or vacuum range.
    UL and C-UL recognized components, CSA certified, and CE marked, they meet American, Canadian, and European safety standards.
    Wire Leads
    4 mA to 20 mA Output Signal—Transmitters with 4 to 20 mA output signal connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Signal is not lost over long distances and isn’t affected by electrical interference from other devices.
    1V DC to 5V DC Output Signal—Transmitters with 1 to 5V DC output signal connect using three wires. Two wires connect to the power supply, and a separate wire sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
    Analog
    Transmitter Output
    Digital
    Switch Output
    Max.
    Pressure, psi
    Setpoint
    Range
    Analog Signal
    No.
    Of
    Digital
    Signal
    No.
    of
    Pressure Range,
    psi
    Vacuum Range,
    in. Hg
    Continuous
    Short-Term
    Pressure,
    psi
    Vacuum,
    in. Hg
    Input Voltage,
    V DC
    Ht.
    Wd.
    Enclosure
    Rating
    For Use With
    Accuracy
    Connection
    Material
    Temp. Range,
    ° F
    Each
    Polybutylene Housing
     
    1/8 Male NPT Pipe Threaded Fitting Connection
    4 mA to 20 mA1PNP20 to 14.50 to 2914.5720 to 14 1/20 to 2912 to 241 13/16"1 13/16"IP40
    Air, Argon, Nitrogen±2%Nickel-Plated Brass25 to 1204263N13000000
    1V DC to 5V DC1PNP20 to 14.50 to 2914.5720 to 14 1/20 to 2912 to 241 13/16"1 13/16"IP40
    Air, Argon, Nitrogen±2%Nickel-Plated Brass25 to 1204263N1100000
     
    1/4" OD Tube Push-to-Connect Fitting Connection
    4 mA to 20 mA1PNP20 to 14.50 to 2914.5720 to 14 1/20 to 2912 to 241 13/16"1 13/16"IP40
    Air, Argon, Nitrogen±2%Nickel-Plated Brass25 to 1204263N1400000
    1V DC to 5V DC1PNP20 to 14.50 to 2914.5720 to 14 1/20 to 2912 to 241 13/16"1 13/16"IP40
    Air, Argon, Nitrogen±2%Nickel-Plated Brass25 to 1204263N1200000
     
    Square Panel-Mount Brackets

    Sanitary Pressure and Vacuum Switches

    Image of Product. Front orientation. Pressure Switches. Sanitary Pressure and Vacuum Switches.
    When these 3-A certified switches reach a set pressure or vacuum, they trigger controls and alarms in food-processing, pharmaceutical, and biotech lines. They have a sleeve to shield internal parts from water and contaminants. Their surfaces are polished and their seams are continuously welded, so cleaning is easy and there’s little room for bacteria to grow. Made of 316 stainless steel, these switches stand up to harsh cleaners and sanitizers without rusting. Rated IP67 and NEMA 6, they’re dust tight and protected from washdowns and temporary submersion.
    They connect using the same quick-clamp fittings (also known as tri-clamp fittings) that are common in sanitary lines, because they’re easy to take apart for cleaning. This end has a diaphragm that protects from corrosion and covers threads to keep them clean. The diaphragm is filled with 99.5% pure USP food-grade glycerin, reducing the risk of contamination if the diaphragm fails. The serial number is laser etched on the diaphragm to reduce crevices.
    Twist the adjustable setpoint ring to make quick changes. These switches are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
    All have a material certificate with a traceable lot number and a calibration certificate traceable to NIST.
    Setpoint
    Pressure,
    psi
    Vacuum,
    in. Hg
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    Wire Lead Connection
     
    For 1 1/2" OD Quick Clamp Tube
    0 to 150 to 303151,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless SteelArgon, Beverage, Diesel Fuel, Food, Gasoline, Hydraulic Fluid, Inert Gas, Natural Gas, Nitrogen, Oil, Oxygen, WaterIP67, NEMA 6
    UL Listed
    8834N2010000000
     
    For 2" OD Quick Clamp Tube
    0 to 150 to 303151,000±2%3 amp @ 28V DC
    5 amp @ 125V AC
    5 amp @ 250V AC
    -40 to 212316 Stainless SteelArgon, Beverage, Diesel Fuel, Food, Gasoline, Hydraulic Fluid, Inert Gas, Natural Gas, Nitrogen, Oil, Oxygen, WaterIP67, NEMA 6
    UL Listed
    8834N206000000
     

    Dual-Setpoint Electronic Pressure and Vacuum Switches for Compressed Air

    Image of Product. Front orientation. Pressure and Vacuum Switches. Dual-Setpoint Electronic Pressure and Vacuum Switches for Compressed Air.
    With two setpoints, these switches trigger different actions in your air system by sending signals to a programmable logic controller (PLC) when they reach one of their set pressures or vacuums. For example, they can activate one light when a system is pressurized and another when it’s under vacuum. They have an adjustable reset, so you can control the amount of pressure change before the switch resets. This pressure difference is also called deadband or differential. Choose a reset point anywhere within the setpoint range.
    Easily monitor your pressure or vacuum setpoint on the digital display. Use its buttons to adjust the settings and setpoint.
    These switches are rated IP65 to seal out dust and water from light rinses. They’re CE marked, UL and C-UL recognized components, and CSA certified to meet American, Canadian, and European safety standards.
    Set Point
    Pressure,
    psi
    Vacuum,
    in. Hg
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Output Digital
    Signal
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    Wire Lead Connection
     
    1/8 NPT Male
    0 to 14 1/20 to 29Adjustable14.572PNP±0.2%35 mA @ 24V DC25 to 120Nickel-Plated BrassAir, Argon, Inert Gas, NitrogenIP65
    3878N110000000
     