    About Proximity Sensors
    industrial info icon

    Compare sensing types, mounting styles, wiring options, and input and output requirements to choose the right proximity sensor for your application.

    Valve Position Sensors

    Image of ProductInUse. Front orientation. Contains Annotated. Proximity Sensors. Valve Position Sensors.
    Image of Product. With Flat Face. Front orientation. Flat Face. Valve Position Sensors.

    With Flat Face

    Image of Product. With Curved Face. Front orientation. Curved Face. Valve Position Sensors.

    With Curved Face

    Image of Specification. 4-Pole M12 Plug. Front orientation. Proximity Sensors. Valve Position Sensors.

    4-Pole

    M12

    Plug

    These sensors detect when a valve is open or closed, supporting flow and temperature control within your system. Secure the sensor to your valve actuator’s mounting holes, and attach an activator (sold separately) to the actuator's shaft. As the actuator opens and closes the valve, the activator rotates until its targets align with the sensor's two inductive sensors. Once they’re aligned, your system will know that the valve is either open or closed—offering reliable feedback on your valve’s position. Connect these sensors to programmable logic controllers (PLCs) to support automated processes. They meet various national and international safety standards, and they’re rated IP67 to protect against dust, washdowns, and temporary submersion.
    To view wiring diagrams, select a part number and click Product Detail.
    Curved Face—Sensors with a curved face minimize pinch points between the sensor and activator, making them good for manually-controlled valves.
    Plug In—Sensors with a 4-pole M12 plug connect to cables with a socket (sold separately), so you can quickly connect and disconnect them.
    Switch Starting
    Position
    Switching
    Freq., Hz
    Max. Sensing
    Distance, mm
    Output Digital
    Signal
    Electrical
    Connection Type
    Input Voltage,
    V DC
    Current
    Output, mA
    No. of Wire
    Leads
    Lg.,
    mm
    Circuit
    Protection
    Cable Lead
    Lg., ft.
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    Flat Face
     
    With 4-Pole M12 Connection
    2 Off
    5003PNPPlug In10 to 3010036Reverse Polarity-10 to 155IP67
    7122N160000000
     
    With Wire Lead Connection
    2 Off
    5003PNPHardwire10 to 30100436Reverse Polarity16-10 to 155IP67
    7122N18000000
     
    With Spring-Clamp Terminal Connection
    2 Off
    5003PNP10 to 3010078Reverse Polarity-10 to 155IP67
    7122N19000000
     
    Curved Face
     
    With 4-Pole M12 Connection
    2 Off
    5003PNPPlug In10 to 3020035Reverse Polarity-10 to 155IP67
    7122N11000000
    2 Off
    1,0004PNPPlug In10 to 3020042Reverse Polarity-10 to 155IP67
    7122N12000000
     
    With Wire Lead Connection
    2 Off
    1,0004PNPHardwire10 to 30200442Reverse Polarity6 1/2-10 to 155IP67
    7122N14000000
     
    With Screw Terminal Connection
    2 Off
    1,0004PNP10 to 3020064Reverse Polarity-10 to 155IP67
    7122N15000000
     
    Accessories for Sensors

    Hazardous Location Valve Position Sensors

    Image of ProductInUse. Front orientation. Contains Annotated. Proximity Sensors. Hazardous Location Valve Position Sensors.
    Image of Product. With Flat Face. Front orientation. Flat Face. Hazardous Location Valve Position Sensors.

    With Flat Face

    Image of Product. With Curved Face. Front orientation. Curved Face. Hazardous Location Valve Position Sensors.

    With Curved Face

    Image of Specification. 4-Pole M12 Plug. Front orientation. Proximity Sensors. Hazardous Location Valve Position Sensors.

    4-Pole

    M12

    Plug

    Support flow and temperature control in your system with these intrinsically safe sensors, which sense when a valve is open or closed in volatile areas. Often used in chemical plants and oil and gas facilities, they are ATEX and IECEx internationally certified to protect against explosion where flammable gases and combustible dust are present.
    Mount the sensor to your valve actuator, and affix a corresponding activator (sold separately) onto your actuator’s shaft. As the valve opens and closes, the activator rotates until its targets align with the two inductive sensors. Once they’re aligned, your system will know that the valve is either open or closed—providing reliable feedback on your valve’s position. These sensors have a 4-pole M12 plug to connect to NAMUR cables (sold separately), letting you quickly connect and disconnect the sensor from your equipment. Connect them to programmable logic controllers (PLCs) to support automated processes. Sensors meet various national and international safety standards, and they’re rated IP67 to protect against dust, washdowns, and temporary submersion.
    To view wiring diagrams, select a part number and click Product Detail.
    Curved Face—Sensors with a curved face minimize pinch points between the sensor and activator, making them good for manually-controlled valves.
    Switch Starting
    Position
    Switching
    Freq., kHz
    Max. Sensing
    Distance, mm
    Output Digital
    Signal
    Electrical
    Connection Type
    Input Voltage,
    V DC
    Current
    Output, mA
    Lg.,
    mm
    Circuit Protection
    Temp. Range,
    ° F
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    Flat Face
     
    With 4-Pole M12 Connection
    2 On
    33NAMURPlug In8 to 8.51036Reverse Polarity
    Short Circuit
    -10 to 210ATEX II 1 D Ex Ia IIIC T135° C Da; ATEX II 1 G Ex Ia IIC T6...T1 Ga; ATEX II 2 G Ex Ia IIC T6...T1 Gb; ATEX II 3 G Ex Ia IIC T6...T1 Gc; IEC Zone 0 Groups IIC, IIB, IIA; IEC Zone 2 Groups IIC, IIB, IIA; IEC Zone 20 Groups IIIC, IIIB, IIIA; IECEx Ex Ia I Mb; IECEx Ex Ia IIC T6...T1 Ga; IECEx Ex Ia IIC T6...T1 Gb; IECEx Ex Ia IIIC T135° C DaIP67
    7114N120000000
     
    Curved Face
     
    With 4-Pole M12 Connection
    2 On
    1.53NAMURPlug In8 to 8.51042Reverse Polarity
    Short Circuit
    -10 to 210ATEX II 1 D Ex Ia IIIC T135° C Da; ATEX II 1 G Ex Ia IIC T6...T1 Ga; ATEX II 2 G Ex Ia IIC T6...T1 Gb; ATEX II 3 G Ex Ia IIC T6...T1 Gc; IEC Zone 0 Groups IIC, IIB, IIA; IEC Zone 2 Groups IIC, IIB, IIA; IEC Zone 20 Groups IIIC, IIIB, IIIA; IECEx Ex Ia I Mb; IECEx Ex Ia IIC T6...T1 Ga; IECEx Ex Ia IIC T6...T1 Gb; IECEx Ex Ia IIIC T135° C DaIP67
    7114N11000000
     
    Accessories for Sensors

    Energy-Saving Compressed Air Drain Valves

    Image of Product. Electric—0.2 gpm Discharge Capacity. Front orientation. Electric. Energy-Saving Compressed Air Drain Valves, 0.2 gpm Discharge Capacity.
    Image of Product. Electric—2.9 gpm Discharge Capacity. Front orientation. Electric. Energy-Saving Compressed Air Drain Valves, 2.9 gpm Discharge Capacity.

    Electric—0.2 gpm

    Discharge Capacity

    Electric—2.9 gpm

    Discharge Capacity

    Save energy by minimizing the loss of compressed air. Unlike other drain valves, these only open when they're full. They close before the reservoir is completely empty, so no air escapes from the system. Install them at low points in your air line after separators, dryers, filters, and aftercoolers.
    Electric—Electric valves have a sensor. When condensate inside the valve rises to the level of the sensor, the valve opens to drain. Valves detect when they’re blocked—they automatically open and close to attempt to remove the blockage and sound an alarm if they’re still blocked.
    Contact for Remote Signaling Device—Drain valves with a contact for remote signaling device can be wired to activate a remote alarm if blocked.
    Inlet
    Outlet
    Overall
    Pipe
    Size
    Thread
    Type
    Gender
    Connection
    For Tube
    ID
    Pipe
    Size
    Thread
    Type
    Gender
    Discharge
    Cap., gpm
    Max. Pressure,
    psi
    Ht.
    Wd.
    Dp.
    Max. Temp.,
    ° F
    Features
    Each
    Aluminum Housing
     
    Electric, 120V AC—Hardwire
    1/2
    NPT
    FemaleBarbed
    1/4"Male0.22302 7/8"4 7/8"3 5/8"120Alarm6773K460000000
     
    Electric, 120V AC—3-Blade Plug
    1/2
    NPT
    FemaleBarbed
    3/8"1/4
    NPT
    Male2.92304 1/2"3 3/8"7"120Alarm, Contact for Remote Signaling Device6773K21000000
     