    17 Products

    Slow-Start Air-Exhaust Valves for Norgren Modular Compressed Air Filter/Regulator/Lubricators (FRLs)

    Image of Product. Front orientation. Air-Exhaust Valves. Slow-Start Air-Exhaust Valves for Norgren Modular Compressed Air Filter/Regulator/Lubricators (FRLs).
    Also known as Monday-morning valves, these valves slowly introduce pressure to reduce surge damage during start-up. When the solenoid is shut off, the valve cuts air to your equipment by exhausting downstream pressure. To ensure compatibility, the valve series number should match the series number on your Norgren components.
    Pipe Size
    Valve
    Overall
    Mfr.
    Series
    Inlet
    Outlet
    Exhaust
    Type
    Position
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Voltage,
    V DC
    Wd.
    Ht.
    Dp.
    Each
    NPT Female Inlet, Outlet, and Exhaust
     
    Series No. 74
    P74F3/8
    3/8
    3/8
    PoppetFail Closed40 scfm @ 100 psi1500 to 125242 7/8"8 3/8"3 1/4"00000000000000
    P74F1/2
    1/2
    1/2
    PoppetFail Closed40 scfm @ 100 psi1500 to 125242 7/8"8 3/8"3 1/4"0000000000000
    P74F3/4
    3/4
    3/4
    PoppetFail Closed40 scfm @ 100 psi1500 to 125242 7/8"8 3/8"3 1/4"0000000000000
     

    Slow-Start Air-Exhaust Valves for SMC Modular Compressed Air Filter/Regulator/Lubricators (FRLs)

    Image of Product. Front orientation. Air-Exhaust Valves. Slow-Start Air-Exhaust Valves for SMC Modular Compressed Air Filter/Regulator/Lubricators (FRLs).
    Also known as Monday-morning valves, these valves slowly introduce pressure to reduce surge damage during start-up. When the solenoid is shut off, the valve cuts air to your equipment by exhausting downstream pressure. To ensure compatibility, the valve series number should match the series number on your SMC components.
    Pipe Size
    Valve
    Overall
    120V AC
    24V DC
    Mfr.
    Series
    Inlet
    Outlet
    Exhaust
    Type
    Position
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Wd.
    Ht.
    Dp.
    Each
    Each
    NPT Female Inlet, Outlet, and Exhaust
     
    Series No. 50
    AVL50003/4
    3/4
    3/4
    SpoolFail Closed250 scfm @ 100 psi14532 to 1405 1/8"7 3/4"2 15/16"0000000000000000000000000000
    AVL50001
    1
    1
    SpoolFail Closed270 scfm @ 100 psi14532 to 1405 1/8"7 3/4"2 15/16"00000000000000000000000000
     

    Slow-Start Air-Exhaust Valves for Wilkerson Modular Compressed Air Filter/Regulator/Lubricators (FRLs)

    Image of Product. Front orientation. Air-Exhaust Valves. Slow-Start Air-Exhaust Valves for Wilkerson Modular Compressed Air Filter/Regulator/Lubricators (FRLs).
    Also known as Monday-morning valves, these valves slowly introduce pressure to reduce surge damage during start-up. When the solenoid is shut off, the valve cuts air to your equipment by exhausting downstream pressure. To ensure compatibility, the valve series number should match the series number on your Wilkerson components.
    Pipe Size
    Valve
    Overall
    120V AC
    24V DC
    Mfr.
    Series
    Inlet
    Outlet
    Exhaust
    Type
    Position
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Wd.
    Ht.
    Dp.
    Each
    Each
    NPT Female Inlet, Outlet, and Exhaust
     
    Series No. 18
    E181/4
    1/4
    3/8
    PoppetFail Closed80 scfm @ 100 psi15032 to 1502 3/4"7 3/8"2 3/8"0000000000000000000000000000
    E183/8
    3/8
    3/8
    PoppetFail Closed90 scfm @ 100 psi15032 to 1502 3/4"7 3/8"2 3/8"00000000000000000000000000
    E181/2
    1/2
    3/8
    PoppetFail Closed95 scfm @ 100 psi15032 to 1502 3/4"7 3/8"2 3/8"00000000000000000000000000
     
    Series No. 28
    E283/8
    3/8
    3/8
    SpoolFail Closed196 scfm @ 100 psi15032 to 1503"7 3/8"2 7/8"———00000000000000
    E281/2
    1/2
    3/8
    SpoolFail Closed210 scfm @ 100 psi15032 to 1503"7 3/8"2 7/8"———00000000000000
    E283/4
    3/4
    3/8
    SpoolFail Closed230 scfm @ 100 psi15032 to 1503"7 3/8"2 7/8"00000000000000000000000000
     
    back to top